Search NASA⌕ Search

SEARCH · Search NASA

Results for “system noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Noise Optimization for MKIDs with Different Design Geometries and Material Selections

The separation and optimization of noise components is critical to microwave-kinetic inductance detector (MKID) development. We analyze the effect of several changes to the lumped-element inductor and interdigitated capacitor geometry on the noise performance of a series of MKIDs intended for millimeter-wavelength experiments. We extract the contributions from two-level system noise in the dielectric layer, the generation-recombination noise intrinsic to the superconducting thin-film, and system white noise from each detector noise power spectrum and characterize how these noise components depend on detector geometry, material, and measurement conditions such as driving power and temperature. We observe a reduction in the amplitude of two-level system noise with both an elevated sample temperature and an increased gap between the fingers within the interdigitated capacitors for both aluminum and niobium detectors. We also verify the expected reduction of the generation-recombination noise and associated quasiparticle lifetime with reduced inductor volume. This study also iterates over different materials, including aluminum, niobium, and aluminum manganese, and compares the results with an underlying physical model.

generation-recombination noise↗

Low two-level-system noise in hydrogenated amorphous silicon

At sub-Kelvin temperatures, two-level systems (TLSs) present in amorphous dielectrics source a permittivity noise, degrading the performance of a wide range of devices using superconductive resonators such as qubits or kinetic inductance detectors. We report here on measurements of TLS noise in hydrogenated amorphous silicon (a-Si:H) films deposited by plasma-enhanced chemical vapor deposition in superconductive lumped element resonators using parallel-plate capacitors. In conclusion, the TLS noise results presented in this article for two recipes of a-Si:H improve on the best results achieved in the literature by a factor >5 for a-Si:H and other amorphous dielectrics and are comparable to those observed for resonators deposited on crystalline dielectrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Tianlai dish pathfinder array: design, operation, and performance of a prototype transit radio interferometer

ABSTRACT The Tianlai Dish Pathfinder Array is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization universe as a means for measuring large-scale cosmic structure. It performs drift scans of the sky at constant declination. We describe the design, calibration, noise level, and stability of this instrument based on the analysis of about 5% of 6200 h of on-sky observations through 2019 October. Beam pattern determinations using drones and the transit of bright sources are in good agreement, and compatible with electromagnetic simulations. Combining all the baselines, we make maps around bright sources and show that the array behaves as expected. A few hundred hours of observations at different declinations have been used to study the array geometry and pointing imperfections, as well as the instrument noise behaviour. We show that the system temperature is below 80 K for most feed antennas and that noise fluctuations decrease as expected with integration time, at least up to a few hundred seconds. Analysis of long integrations, from 10 nights of observations of the North Celestial Pole (NCP), yielded visibilities with amplitudes of 20–30 mK, consistent with the expected signal from the NCP radio sky with ${\lt}10\,$ mK precision for 1 MHz × 1 min binning. Hi-pass filtering the spectra to remove smooth spectrum signal yields a residual consistent with zero signal at the $0.5\,$ mK level.

(cosmology:) large-scale structure of the Universe↗

W-band system-on-chip electron cyclotron emission imaging system on DIII-D

Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation induced non-linear oscillations in ITER baseline scenario plasmas in DIII-D

Abstract This work shows how the radiation brought about by metals or metal-equivalent radiators such as Kr and Xe produces non-linear dynamics on otherwise stationary β N flattops of DIII-D ITER Baseline Scenario demonstration discharges. The Kr and Xe gases are used to reproduce the radiative loss rates of W in present machines that operate at core temperatures much lower than the expected ITER temperature. Experiments on DIII-D with injection of Kr and Xe, as well as with sources of intrinsic metals reach the range of radiated fraction values expected in the ITER core and experience slow oscillations in temperature and radiated power. In many cases of high radiated fraction, the core temperature decreases enough for the safety factor profile to rise above the 1/1 rational surface, naturally eliminating sawteeth and occasionally producing a persistent helical core. The oscillations can be reproduced by a modified Lotka–Volterra system for temperature and radiated fraction if diffusion and noise are included, which indicates that the interplay between temperature and radiation can be the main cause of the cyclic nature of the system. A new physics based model which includes equations for temperature, density and input power can also reproduce the oscillations observed in the experiments. The present results suggest that the non-linearity of the system can be increased by the inclusion of the inherently non-linear alpha heating term, which is proportional to ∼ n e 2 T i 2 , and obtains oscillations in the model when added to an otherwise more stationary system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum criticality using a superconducting quantum processor

Quantum criticality emerges from the collective behavior of many interacting quantum particles, often at the transition between different phases of matter. It is one of the cornerstones of condensed matter physics, which we access on noisy intermediate-scale (NISQ) quantum devices by leveraging a dynamically driven phenomenon. Here we probe the critical properties of the one-dimensional quantum Ising model on a programmable superconducting quantum chip via a Kibble-Zurek process, obtain scaling laws, and estimate critical exponents despite inherent sources of errors on the hardware. In addition, we investigate how the improvement of NISQ computers (more qubits, less noise) will consolidate the computation of those universal physical properties. A one-parameter noise model captures the effect of imperfections and reproduces the experimental data. Its systematic study reveals that the noise, analogously to temperature, induces a new length scale in the system. We introduce and successfully verify modified scaling laws, directly accounting for the noise without any prior knowledge. It makes data analyses for extracting physical properties transparent to noise. By understanding how imperfect quantum hardware modifies the genuine properties of quantum states of matter, we enhance the power of NISQ processors considerably for addressing quantum criticality and potentially other phenomena and algorithms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and novel application of power over fiber for electronics in a harsh environment

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at ∼ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer optical power. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency (∼ 51%), and superior isolation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-Long Distance BOTDA Sensor System Employing Hybrid Amplification and Advanced Noise Reduction Techniques

Brillouin Optical Time Domain Analysis (BOTDA) sensor system play a pivotal role in distributed sensing, which enables precise measurements of strain and temperature across extensive fiber lengths. Nonetheless, challenges emerge as distances grow due to signal attenuation and noise interference resulting in measurement errors. This research offers a comprehensive strategy to extend the sensing range of BOTDA systems beyond 10’s of kilometers while maintaining high spatial resolutions. Such enhanced sensing is realized through the integration of distributed Raman amplification, inline amplification using erbium-doped fiber amplifiers (EDFA), and advanced noise reduction techniques. Leveraging inherent redundancy in measured data as a function of frequency and fiber distance, the non-local means (NLM) filter removes noise while preserving essential physical information. This approach proves particularly advantageous in BOTDA systems, where accurate measurement of Brillouin scattering signals is paramount for long-range sensing, while concurrently safeguarding high spatial resolutions. In summary, this research has shown a holistic exploration of extending BOTDA's distance sensing capabilities up to 150 km with spatial resolutions of 8 meters.

Bhatta, Hari↗

Spectral deconvolution without the deconvolution: Extracting temperature from x-ray Thomson scattering spectra without the source-and-instrument function

X-ray Thomson scattering (XRTS) probes the dynamic structure factor of the system, but the measured spectrum is broadened by the combined source-and-instrument function (SIF) of the setup. In order to extract properties such as temperature from an XRTS spectrum, the broadening by the SIF needs to be removed. Recent work [Dornheim et al. Nat. Commun. 13 , 7911 (2022)] has suggested that the SIF may be deconvolved using the two-sided Laplace transform. However, the extracted information can depend strongly on the shape of the input SIF, and the SIF is in practice challenging to measure accurately. Here, we propose an alternative approach: we demonstrate that considering ratios of Laplace-transformed XRTS spectra collected at different scattering angles is equivalent to performing the deconvolution, but without the need for explicit knowledge of the SIF. From these ratios, it is possible to directly extract the temperature from the scattering spectra, when the system is in thermal equilibrium. We find the method to be generally robust to spectral noise and physical differences between the spectrometers, and we explore situations in which the method breaks down. Furthermore, the fact that consistent temperatures can be extracted for systems in thermal equilibrium indicates that non-equilibrium effects could be identified by inconsistent temperatures of a few eV between the ratios of three or more scattering angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noise and thermal depinning of Wigner crystals

We examine changes in the depinning threshold and conduction noise fluctuations for driven Wigner crystals in the presence of quenched disorder. At low temperatures there is a well defined depinning threshold and a strong peak in the noise power with 1/f noise characteristics. At higher temperatures, the depinning threshold shifts to lower drives and the noise, which is also reduced in power, becomes more white in character. At lower temperatures, a washboard frequency appears when the system depins elastically or forms a moving smectic state; however, this washboard signal is strongly reduced for higher temperatures and completely disappears above the melting temperature of a system without quenched disorder. Our results are in good agreement with recent transport and noise studies for systems where electron crystal depinning is believed to arise, and also show how noise can be used to distinguish between crystal, glass, and liquid phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coupling Two Laser-Cooled Ions via a Room-Temperature Conductor

We demonstrate coupling between the motions of two independently trapped ions with a separation distance of 620 μm. Here, the ion-ion interaction is enhanced via a room-temperature electrically floating metallic wire which connects two surface traps. Tuning the motion of both ions into resonance, we show flow of energy with a coupling rate of 11 Hz. Quantum-coherent coupling is hindered by strong surface electric-field noise in our device. Our ion-wire-ion system demonstrates that room-temperature conductors can be used to mediate and tune interactions between independently trapped charges over distances beyond those achievable with free-space dipole-dipole coupling. This technology may be used to sympathetically cool or entangle remotely trapped charges and enable coupling between disparate physical systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance Evaluation of High-Temperature Ultrasonic Communication System

Ultrasonic communication is a technique that allows transmitting information through a solid material such as tubes or bars using high-frequency elastic waves. The communication channels often extend into a high-temperature range in the field of power, oil, or nuclear industry. When the temperature is taken into consideration, the ultrasonic wave propagation through the solid channel is complex and unpredictable. It is necessary to study the influence of temperature on the ultrasonic guided wave to improve ultrasonic communication. In this study, a temperature control system is assembled to adjust the temperature of a steel pipe channel ranging from room temperature to 150 degrees C. The temperature performance evaluation is conducted to estimate the signal-to-noise ratio (SNR) and bit error rate (BER) of transferring the ultrasonic signal. The work aims to develop a reliable ultrasonic communication system in a high-temperature environment. The system temperature can be maintained at 150 degrees C and the LiNbO3 transducers are used as transmitters and receivers. No power amplifier is used in the communication system. The high-temperature ultrasonic communication system (HT-UCS) is feasible at 150 degrees C and can achieve a bit rate of 10 kbps without any error.

HT-UCS↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗