Bayesian identification of system parameters
System parameters identification from short-term signal observations, using Bayesian approach
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
System parameters identification from short-term signal observations, using Bayesian approach
Gradient search procedures application for nonlinear system unknown parameters identification from system dynamic response observations
In the analysis of vibrations of continuous elastic systems, one often encounters complicated transcendental equations with roots directly related to the system's natural frequencies. Typically, these equations contain system parameters whose values must be specified before a numerical solution can be obtained. The present paper presents a method whereby the fundamental frequency can be obtained in analytical form to any desired degree of accuracy. The method is based upon truncation of rapidly converging series involving inverse powers of the system natural frequencies. A straightforward method to developing these series and summing them in closed form is presented. It is demonstrated how Computer Algebra can be exploited to perform the intricate analytical procedures which otherwise would render the technique difficult to apply in practice. We illustrate the method by developing two analytical approximations to the fundamental frequency of a vibrating cantilever carrying a rigid tip body. The results are compared to the numerical solution of the exact (transcendental) frequency equation over a range of system parameters.
Distributed parameter systems stability as internal and input-output property, describing Liapunov functionals construction
Distributed parameter systems under load disturbances regulatory control by feedforward feedback and state measures
Distributed parameter systems with transfer function as ratio of output and input multiple transforms, deriving open and closed loop stability criteria
Distributed parameter systems described by parabolic differential equations in Hilbert space, discussing existence of optimal control based on quadratic cost criteria
Distributed Parameter Systems (DPS), such as systems described by partial differential equations, require infinite-dimensional state space descriptions to correctly model their dynamical behavior. However, any adaptive control algorithm must be finite-dimensional in order to be implemented via on-line digital computers. Finite-dimensional adaptive control of linear DPS requires stability analysis of nonlinear, time-varying, infinite-dimensional systems. The structure of nonadaptive finite-dimensional control of linear DPS is summarized as it relates to the existence of limiting systems for adaptive control. Two candidate schemes for finite-dimensional adaptive control of DPS are described and critical issues in infinite-dimensional stability analysis are discussed, in particular, the invariance principle, center manifold theory, and relationships between input-output and internal stability.
An electrospinning system using a spinneret and a counter electrode is first operated for a fixed amount of time at known system and operational parameters to generate a fiber mat having a measured fiber mat width associated therewith. Next, acceleration of the fiberizable material at the spinneret is modeled to determine values of mass, drag, and surface tension associated with the fiberizable material at the spinneret output. The model is then applied in an inversion process to generate predicted values of an electric charge at the spinneret output and an electric field between the spinneret and electrode required to fabricate a selected fiber mat design. The electric charge and electric field are indicative of design values for system and operational parameters needed to fabricate the selected fiber mat design.
Neutron polarization analysis has been carried out in order to clarify the magnetic structures of multiple order parameter f-electron system NdB 4 . We confirmed the noncollinear “all-in all-out” structure (Γ 4 ) of the in-plane moment, which is in good agreement with our previous neutron powder diffraction study. We found that the magnetic moment along the c-axis m c showed diagonally antiferromagnetic structure (Γ 10 ), inconsistent with previously reported “vortex” structure (Γ 2 ). The microscopic mixture of these two structures with → q 0 =(0,0,0) appears in phase II and remains stable in phases III and IV, where an incommensurate modulation coexists. The unusual magnetic ordering is phenomenologically understood via Landau theory with the primary order parameter Γ 4 coupled with higher-order secondary order parameter Γ 10 . The magnetic moments were estimated to be 1.8 ± 0.2 and 0.2 ± 0.05μ B at T = 7.5K for Γ 4 and Γ 10 , respectively. We also found a long-period incommensurate modulation of the → q 1 =(0,0,1/2) antiferromagnetic structure of mc with the propagation → q s1 =(0.14,0.14,0.1) and → q s2 =(0.2,0,0.1) in phase III and IV, respectively. The amplitude of sinusoidal modulation was about m c =1.0 ± 0.2μ B at T=1.5 K. The local (0,0,1/2) structure consists of in-plane ferromagnetic and out-of-plane antiferromagnetic coupling of m c , opposite to the coexisting Γ 10 . The mc of Γ 10 is significantly enhanced up to 0.6μ B at T=1.5 K, which is accompanied by the incommensurate modulations. As a result, the Landau phenomenological approach indicates that the higher-order magnetic and/or multipole interactions based on the pseudoquartet f-electron state play important roles.
Distributed parameter feedback systems with quadratic cost criteria, obtaining optimal controls characterization
The effects of system parameters on the interface condensation rate in a laminar jet induced mixing tank are numerically studied. The physical system consists of a partially filled cylindrical tank with a slightly subcooled jet discharged from the center of the tank bottom toward the liquid-vapor interface which is at a saturation temperature corresponding to the constant tank pressure. Liquid is also withdrawn from the outer part of the tank bottom to maintain the constant liquid level. The jet velocity is selected to be low enough such that the free surface is approximately flat. The effect of vapor superheat is assumed to be negligible. Therefore, the interface condensation rate can be determined from the resulting temperature field in the liquid region alone. The nondimensional form of the steady state conservation equations are solved by a finite difference method for various system parameters including liquid height to tank diameter ratio, tank to jet diameter ratio, liquid inflow to outflow area ratio, and a heat leak parameter which characterizes the uniform wall heat flux. Detailed analyses based on the numerical solutions are performed and simplified equations are suggested for the prediction of condensation rate.
The effects of system parameters on the interface condensation rate in a laminar jet induced mixing tank are numerically studied. The physical system consists of a partially filled cylindrical tank with a slightly subcooled jet discharged from the center of the tank bottom toward the liquid-vapor interface which is at a saturation temperature corresponding to the constant tank pressure. Liquid is also withdrawn from the outer part of the tank bottom to maintain the constant liquid level. The jet velocity is selected to be low enough such that the free surface is approximately flat. The effect of vapor superheat is assumed to be negligible. Therefore, the interface condensation rate can be determined from the resulting temperature field in the liquid region alone. The nondimensional form of the steady state conservation equations are solved by a finite difference method for various system parameters including liquid height to tank diameter ratio, tank to jet diameter ratio, liquid inflow to outflow area ratio, and a heat leak parameter which characterizes the uniform wall heat flux. Detailed analyses based on the numerical solutions are performed and simplified equations are suggested for the prediction of condensation rate.
Specifically, a class of distributed parameter systems is defined using Hilbert space methods based on a partial differential equation model of a structure. In this space a simple, easy to check definition of underdamping is constructed based on the well known single degree of freedom concept of critical damping. It is then shown that if a given distributed parameter system satisfies this definition, each mode of the modal expansion of the solution is in fact an underdamped function of time. It is noted that a distributed parameter system which is underdamped is also uniformly exponentially stable. By appealing to the work of Gibson, a finite dimensional model of the system will yield satisfactory control laws. Furthermore, it is shown that the assumption of the underdamping also allows straightforward computation of rough bounds on the magnitude of the unmodeled or residual modes for a modal truncation scheme. Hence, underdamped systems are precisely that class of distributed parameter systems which are not likely to have spillover problems and which will yield convergence of finite dimensional control laws to control laws which are optimal for the full distributed parameter model of the system.
Due to the irregular nature of real waves, the power captured in a wave energy converter (WEC) system is highly variable. This is an important barrier to the effective use of WECs. To address this challenge, this study focuses on a rotational WEC power-take-off system in which high-speed and high-efficiency generators along with a torque/power smoothing inertia element can be effectively utilized. In the first phase of this study, the U.S. Department of Energy’s reference model 3 (WEC-Sim RM3; two-body point absorber), along with a slider-crank WEC, were integrated for linear to rotational conversion. Relative motion between the float and spar in RM3 was the driving force for this slider-crank WEC, which is connected to a motor/generator set through a gearbox. RM3 geometry was scaled down by 25 times to work within the limits of the physical motor/generator set used in the experimentation. Once the integration in a hardware-in-the-loop simulation environment was successfully completed, data on the peak-to-average power ratio was collected for various wave conditions including regular and irregular waves. The control algorithm designed to keep the system in resonance with waves was able to maintain relatively high speed depending on the specific gear ratio and wave period. Initial results with hardware-in-the-loop simulations reveal that gear ratio and crank radius have a strong impact on the peak-to-average power ratio. In addition, it was found that output power from the generator was maximized at a larger gear ratio, as the crank radius was increased.
Binary data system parameters sudden change detection by noisy observation based on Bayes criterion
A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.
Parameter-dependence properties are developed in the context of a linear abstract Cauchy problem governed by a parameter-dependent operator. Of particular interest are problems in which the parameter induces an unbounded perturbation of the evolution operator. Conditions are stated under which the derivative of the state with respect to the parameter possesses certain smoothness properties. These properties lead to local convergence results for a gradient-based estimation algorithm based on quasi-linearization. Numerical results concerning a delay-differential equation indicate the effect of a forcing function on parameter sensitivity.