Search NASASearch

SEARCH · Search NASA

Results for “systemic risk”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hydrogen Transportation and Distributed Energy Systems Risk Assessment for Airport Facilities (CRADA 555) (Final Report)

Portland International Airport (PDX), Oregon, operated by the Port of Portland (Port) is exploring the possibility of operating a fleet of 28 fuel cell electric buses and developing a distributed energy system to support airport operations during various operating modes including large-scale power outages. This study investigates the compatibility of these two missions, which will be key to resilience management at PDX. This study also investigated the risks associated with deploying a hydrogen system that could support bus operations and be utilized during an emergency to ensure continued operation of the airport. This will be a key innovation for the deployment of hydrogen systems at airports. Utilizing the unique benefits of hydrogen infrastructure for multiple roles will aid adopters in justifying new projects and serve to demonstrate the versatility of hydrogen as an energy-carrier to a wider market.

08 HYDROGEN

Natural Hazard Forecast Alert Grid Risk System

Weather events cause most power outages. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Idaho National Laboratory had a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response program to develop a grid alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios using MASTERRI (Modeling And Simulation for Targeted Reliability and Resilience Improvement). For high-risk events, the application can then send alert links to subscribed electric distribution utility operations staff to allow them to see and evaluate the scenarios and the impact in a web based interactive map tool. This proof of concept application used data from utilities and organizations, such as the international regulatory body North American Electric Reliability Corporation, which have complied historical failure data of elements that comprise the U.S. electric grid. Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates were calculated for different component types given the alert type, severity, and location. Historic weather-related grid element failures were correlated with historic weather events from the Integrated Public Alert & Warning System. These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. Working with an industry collaborator, actual grid models and data were used for demonstration cases. This report outlines the work performed for this project.

24 - POWER TRANSMISSION AND DISTRIBUTION

Application of Banking Scoring and Rating for Coherent Risk Measures in Electricity Systems ABSCORES

This project developed a framework for asset and system risk management that can be incorporated into current electricity system operations to improve economic efficiency and establish an Electric Assets Risk Bureau. We leveraged scoring and ratings from banking and financial institutions alongside current optimization methods in dispatching power systems to help system operators and electricity markets schedule resources. This approach is based on the observation that there are major discrepancies between the power scheduled by a system operator and the actual power generated/consumed. These discrepancies—exacerbated by unplanned contingencies (e.g., natural disasters)—are caused by multiple factors, including the different financial, environmental and risk preferences of power producers, consumers, and aggregators. We developed a framework that counteracts two failures in electricity system operations: imperfect information and missing markets for products. The technical approach included five tasks. Tasks 1 and 2 supported the development of risk scores at the asset level with historical data collected for this project. Tasks 3, 4, and 5 incorporated scoring into decision-making at the system level. The proposed effort achieved PERFORM's Program Objectives because the proposed outputs and algorithms do not exist in the electricity industry and are an innovative approach to managing risk. Since the acknowledged need to better assess and act upon risk profiles for grid assets has not been met by the industry, this project will also impact ARPA-E's Mission Areas, including improving energy efficiency and giving the U.S. a technological lead in advanced energy technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY

System-Level Integration of Modular Language Models for Real-Time Risk Assessment in Third-Party Risk Management Systems

Large enterprises typically rely on dedicated teams to govern and implement security measures throughout their supply chains, ensuring compliance with enterprise security procedures. There is a significant reliance on Third-Party Risk Management (TPRM) platforms, which often require complete, highly structured information from potential vendors. The review and compliance assurance processes are time- and labor intensive, often requiring several rounds of review between the supply chain security risk management teams, business users, and potential vendors, leading to delays in the supply chain processing and consumer experience. Significant challenges in the risk management paradigm include handling unstructured data in various formats and providing real-time feedback to users to reduce the required review time. This paper presents a novel solution to these challenges. A modular multi-step system architecture is proposed using advances in language processing, specifically for unstructured responses and provides real-time feedback (i.e., 3 seconds) so that users can improve their responses before the TPSRM team review. This novel system architecture will increase information accuracy and significantly reduce time and labor during the review process.

99 - GENERAL AND MISCELLANEOUS

System Safety Risk Analysis Models (SSRAM)

This presentation provides a high level overview of the System Safety Risk Analysis (SSRAM) methodology and motivation.

Clark, Andrew Jordan [Sandia National Laboratories

Probabilistic physics of failure approach to fusion systems & Risk-efficiency optimization of nuclear co-generation [Slides]

An overview of the progress made towards two separate summer internship projects: a probabilistic physics of failure approach to fusion systems and a risk efficiency optimization of nuclear co-generation. Original version summarized the progress through end of June, and the revision version summarizes the progress through the entire internship to August 1st.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available.

08 HYDROGEN

​​Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities​

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available. To characterize the seismic hazard, we considered the initiating event frequency of a Cascadia Subduction Zone earthquake event based on data from the literature. Seismic stressors that translate to the site from an earthquake event are expressed as peak ground acceleration. Site disturbance is characterized as a function of soil conditions, represented by different shear wave velocity values, which affect how seismic waves propagate and impact structures. Pipe fragility curves as a function of seismic capacity were used to correlate ground acceleration and failure probability. These fragility characteristics were combined with site-specific soil conditions to calculate the probability of pipe rupture during a seismic event. It should be noted that multiple simultaneous failures due to an earthquake event as a common cause are not considered. Some epistemic uncertainties such as self-exciting shocks, aftershocks, and the time variant nature of the ground motion are not considered either.

08 HYDROGEN

Interconnected Risks in Electricity Systems: Understanding Research Challenges, Needs, and Partnerships

The U.S. federal government has a potential role in mitigating the most poorly addressed risks across electricity markets and interdependent systems. Electricity system risks stem from extreme acute shocks (e.g., cyberattacks, extreme weather, and supply chain disruptions) and chronic stressors (e.g., global economic competition, uncertainties surrounding emerging technologies, climate change, and related conflicts). These acute shocks and chronic stressors can result in dire consequences for society, underscoring the need for better information for decision makers in both public and private sectors. Best practices and a shared understanding of risk management and risk quantification must be rapidly developed and disseminated. Informed by a quantitative treatment of risk to electrical infrastructure and interdependent systems, decision makers can more prudently and efficiently prioritize mitigation initiatives to maximize benefits to government, businesses, and the public.

24 POWER TRANSMISSION AND DISTRIBUTION

Smart Inverters, Dumb Risk: Taking Control of IBR Security in the Digital Age

This presentation addresses the security challenges posed by Inverter-Based Resources (IBRs) in the modern energy landscape. The presentation highlights the vulnerabilities and risks associated with IBRs, including the potential for cyber-attacks, the impact of insecure defaults, and the systemic risks posed by supply chain dependencies. Key topics covered include: 1) The increasing digital transformation in energy systems and the associated security risks. 2) Specific vulnerabilities in IBRs, including weak passwords, hardcoded credentials, and insecure web application interfaces. 3) The implications of persistent connectivity and the strategic risks posed by foreign-manufactured components. 4) The role of regulatory frameworks, such as NERC CIP, in addressing these challenges and the limitations of current oversight. 5) Practical solutions for mitigating risks, including secure design practices, vendor risk assessments, and the importance of strong passwords and role-based access control. The presentation underscores the necessity of a comprehensive, system-of-systems approach to securing IBRs, emphasizing the need for collaboration across various stakeholders, including operators, developers, and regulators, to ensure the resilience and security of the energy grid.

24 - POWER TRANSMISSION AND DISTRIBUTION

Carbon Fiber Oxidation in 4D

The oxidation of carbon fibers at high temperatures is the primary degradation process in the thermal protection system of many hypersonic flight vehicles. Predicting the rate and the extent of oxidation is critical to ensure a safe and effective design. An oversized thermal protection system adds unnecessary mass, while an under-designed one risks system failure and mission loss. Resolving high-temperature material degradation due to oxidation has been a long-standing challenge in designing for re-entry flight environments. Using time-resolved in situ X-ray microtomography, the oxidation of carbon fibers at high temperatures is directly imaged, resolving the two limiting degradation regimes: diffusion- and reaction-limited. The ability to resolve material degradation in time at the sub-micron scale sheds light on the ablation phenomenon and enables predictions of material constitutive properties evolving in time, with profound implications on the ability to model the aerothermal response of heat shield materials in hostile environments.

ablation

Advancing Our Understanding of System Availability through the PV Fleet Performance Data Initiative

The PV Fleet Performance Data Initiative partners with photovoltaic (PV) fleet owners to collect time-series data of PV production data and publishes aggregated anonymized results of system performance metrics. With an extensive dataset drawn from over 2,200 PV systems across the United States, comprising 8.5 GW and 24,000 separate inverter data channels, this initiative aims to ensure that systemic risks in the US PV fleet are detected. The current work explores system availability, revealing a pronounced dependence on time, especially within the initial 6 months of system performance. Following this start-up period, the average system availability stabilizes. Statistical analyses illustrate a median (P5O) monthly availability of 0.991 and a dependence on system size with a negative trend in availability with increasing system size. This finding indicates that larger systems experience lower availability compared to their smaller counterparts.

inverter availability

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY

Integrating Intelligent Hydro-informatics into an effective Early Warning System for risk-informed urban flood management

The urban drainage system constantly facing flooding issues in coastal and urban areas. Robust and accurate urban flood management, particularly considering fast-moving compound floods, is crucial to minimize the impact of flood disasters in coastal cities. Till now, Ho Chi Minh City (HCMC) lacks an effective means of urban flood management because of flood risk communication among residents. Existing flood risk communication tools rely on post-disaster flood model outcomes and data. Therefore, this research proposes a real-time Early Urban Flooding Warning System (EUFWS) integrated with a user-friendly web and app interface. The backbone of this system consists of flood models developed using machine learning (ML) algorithms, combined with big data and Web-GIS visualization, with ML serving as the core for constructing the EUFWS. EUFWS offer several key advantages: they are available at all times, accessible from anywhere, and provide a real-time, multi-user working platform. Additionally, the system is flexible, allowing for the easy addition of components and services and scalable, adjusting to workload demands. EUFWS have been successfully deployed in Thu Duc City, Vietnam, as a case study and are operating effectively. EUFWS have been successfully deployed in Thu Duc City, Vietnam, as a case study and are operating effectively. Research results indicate that EUFWS supported decision-makers to be effectively risk informed and make intelligent decisions during urban flood emergencies. Finally, this underscores the significant potential of integrating ML and information technology to enhance the management of smart urban drainage systems in flood-prone cities worldwide.

54 ENVIRONMENTAL SCIENCES

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE

The hidden costs of concealing outdoor air conditioning units

The beautification of urban facades in China often includes covers for the outdoor units of air conditioners. Although these covers improve cityscapes, they reduce cooling efficiency, increase noise pollution, risk system failures and embody carbon emissions. A call urges rethinking their necessity, and presses for sustainable, efficient design to counteract extreme heat.

Wang, Wei

CyTRICS™ Assessment Report: Whole Home Battery Applications

This report examines the software supply chain security posture of mobile applications developed for consumer whole-house battery and energy-management products. While these applications are not currently integrated with critical infrastructure, their growing role in connected energy domain spaces underscores the importance of understanding the external dependencies, permission structures, and runtime behaviors that could introduce systemic risk; particularly, if adoption expands into more critical environments.

25 ENERGY STORAGE