Search NASA⌕ Search

SEARCH · Search NASA

Results for “systole”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship

OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

Non-NASA Center↗

Systolic array processing of the sequential decoding algorithm

A systolic array processing technique is applied to implementing the stack algorithm form of the sequential decoding algorithm. It is shown that sorting, a key function in the stack algorithm, can be efficiently realized by a special type of systolic arrays known as systolic priority queues. Compared to the stack-bucket algorithm, this approach is shown to have the advantages that the decoding always moves along the optimal path, that it has a fast and constant decoding speed and that its simple and regular hardware architecture is suitable for VLSI implementation. Three types of systolic priority queues are discussed: random access scheme, shift register scheme and ripple register scheme. The property of the entries stored in the systolic priority queue is also investigated. The results are applicable to many other basic sorting type problems.

Chang, C. Y.↗

On some equivalent configurations of systolic arrays

A systematic approach is presented for designing systolic arrays and their equivalent configurations for certain general classes of recursively formulated algorithms. A new method is also introduced to reduce the input bandwidth and storage requirements of the systolic arrays through the study of dependence among the input data. Many well known systolic arrays can be rederived and also many new systolic arrays can be discovered by this approach.

Chang, C. Y.↗

On realizations of least-squares estimation and Kalman filtering by systolic arrays

Least-squares (LS) estimation is a basic operation in many signal processing problems. Given y = Ax + v, where A is a m x n coefficient matrix, y is a m x 1 observation vector, and v is a m x 1 zero mean white noise vector, a simple least-squares solution is finding the estimated vector x which minimizes the norm of /Ax-y/. It is well known that for an ill-conditioned matrix A, solving least-squares problems by orthogonal triangular (QR) decomposition and back substitution has robust numerical properties under finite word length effect since 2-norm is preserved. Many fast algorithms have been proposed and applied to systolic arrays. Gentleman-Kung (1981) first presented the trianglular systolic array for a basic Givens reduction. McWhirter (1983) used this array structure to find the least-squares estimation errors. Then by geometric approach, several different systolic array realizations of the recursive least-squares estimation algorithms of Lee et al (1981) were derived by Kalson-Yao (1985). Basic QR decomposition algorithms are considered in this paper and it is found that under a one-row time updating situation, the Householder transformation degenerates to a simple Givens reduction. Next, an improved least-squares estimation algorithm is derived by considering a modified version of fast Givens reduction. From this approach, the basic relationship between Givens reduction and Modified-Gram-Schmidt transformation can easily be understood. This improved algorithm also has simpler computational and inter-cell connection complexities while compared with other known least-squares algorithms and is more realistic for systolic array implementation.

Chen, M. J.↗

Recursive least squares estimation and Kalman filtering by systolic arrays

One of the most promising new directions for high-throughput-rate problems is that based on systolic arrays. In this paper, using the matrix-decomposition approach, a systolic Kalman filter is formulated as a modified square-root information filter consisting of a whitening filter followed by a simple least-squares operation based on the systolic QR algorithm. By proper skewing of the input data, a fully pipelined time and measurement update systolic Kalman filter can be achieved with O(n squared) processing cells, resulting in a system throughput rate of O (n).

Chen, M. J.↗

Doppler-derived myocardial systolic strain rate is a strong index of left ventricular contractility

BACKGROUND: Myocardial fiber strain is directly related to left ventricular (LV) contractility. Strain rate can be estimated as the spatial derivative of velocities (dV/ds) obtained by tissue Doppler echocardiography (TDE). The purposes of the study were (1) to determine whether TDE-derived strain rate may be used as a noninvasive, quantitative index of contractility and (2) to compare the relative accuracy of systolic strain rate against TDE velocities alone. METHODS AND RESULTS: TDE color M-mode images of the interventricular septum were recorded from the apical 4-chamber view in 7 closed-chest anesthetized mongrel dogs during 5 different inotropic stages. Simultaneous LV volume and pressure were obtained with a combined conductance-high-fidelity pressure catheter. Peak elastance (Emax) was determined as the slope of end-systolic pressure-volume relationships during caval occlusion and was used as the gold standard of LV contractility. Peak systolic TDE myocardial velocities (Sm) and peak (epsilon'(p)) and mean (epsilon'(m)) strain rates obtained at the basal septum were compared against Emax by linear regression. Emax as well as TDE systolic indices increased during inotropic stimulation with dobutamine and decreased with the infusion of esmolol. A stronger association was found between Emax and epsilon'(p) (r=0.94, P<0.01, y=0.29x+0.46) and epsilon'(m) (r=0.88, P<0.01) than for Sm (r=0.75, P<0.01). CONCLUSIONS: TDE-derived epsilon'(p) and epsilon'(m) are strong noninvasive indices of LV contractility. These indices appear to be more reliable than S(m), perhaps by eliminating translational artifact.

Non-NASA Center↗

Chronic N(G)-nitro-L-arginine methyl ester-induced hypertension : novel molecular adaptation to systolic load in absence of hypertrophy

BACKGROUND: Chronic N(G)-nitro-L-arginine methyl ester (L-NAME), which inhibits nitric oxide synthesis, causes hypertension and would therefore be expected to induce robust cardiac hypertrophy. However, L-NAME has negative metabolic effects on protein synthesis that suppress the increase in left ventricular (LV) mass in response to sustained pressure overload. In the present study, we used L-NAME-induced hypertension to test the hypothesis that adaptation to pressure overload occurs even when hypertrophy is suppressed. METHODS AND RESULTS: Male rats received L-NAME (50 mg. kg(-1). d(-1)) or no drug for 6 weeks. Rats with L-NAME-induced hypertension had levels of systolic wall stress similar to those of rats with aortic stenosis (85+/-19 versus 92+/-16 kdyne/cm). Rats with aortic stenosis developed a nearly 2-fold increase in LV mass compared with controls. In contrast, in the L-NAME rats, no increase in LV mass (1. 00+/-0.03 versus 1.04+/-0.04 g) or hypertrophy of isolated myocytes occurred (3586+/-129 versus 3756+/-135 microm(2)) compared with controls. Nevertheless, chronic pressure overload was not accompanied by the development of heart failure. LV systolic performance was maintained by mechanisms of concentric remodeling (decrease of in vivo LV chamber dimension relative to wall thickness) and augmented myocardial calcium-dependent contractile reserve associated with preserved expression of alpha- and beta-myosin heavy chain isoforms and sarcoplasmic reticulum Ca(2+) ATPase (SERCA-2). CONCLUSIONS: When the expected compensatory hypertrophic response is suppressed during L-NAME-induced hypertension, severe chronic pressure overload is associated with a successful adaptation to maintain systolic performance; this adaptation depends on both LV remodeling and enhanced contractility in response to calcium.

Non-NASA Center↗

Systolic multipliers for finite fields GF(2 exp m)

Two systolic architectures are developed for performing the product-sum computation AB + C in the finite field GF(2 exp m) of 2 exp m elements, where A, B, and C are arbitrary elements of GF(2 exp m). The first multiplier is a serial-in, serial-out one-dimensional systolic array, while the second multiplier is a parallel-in, parallel-out two-dimensional systolic array. The first multiplier requires a smaller number of basic cells than the second multiplier. The second multiplier needs less average time per computation than the first multiplier, if a number of computations are performed consecutively. To perform single computations both multipliers require the same computational time. In both cases the architectures are simple and regular and possess the properties of concurrency and modularity. As a consequence, they are well suited for use in VLSI systems.

Yeh, C.-S.↗

Results in least-square estimation algorithms with systolic array architectures

It is proposed that the derivation of least-square algorithms for systolic array processing is best accomplished via a geometrical approach. This approach generates a set of vector equations from which a large number of new and previously known systolic arrays can be obtained in a unified manner. The paper presents and qualitatively describes these vector equations and shows how one such systolic array follows.

Kalson, S.↗

Systolic array processing of the Viterbi algorithm

Results on efficient forms of decoding convolutional codes based on the Viterbi algorithm by using systolic arrays are presented. Various properties of convolutional codes are discussed. A technique called strongly connected trellis decoding is introduced to increase the efficient utilization of all the systolic array processors. Issues dealing with the composite branch metric generation, survivor updating, overall system architecture, throughput rate, and computational overhead ratio also investigated. The scheme is applicable to both hard and soft decoding of any rate b/n convolutional code. It is shown that as the length of the code becomes large, the systolic Viterbi decoder maintains a regular and general interconnection structure as well as moderate throughput rate gain over the sequential Viterbi decoder.

Chang, Chi-Yung↗

FFT Computation with Systolic Arrays, A New Architecture

The use of the Cooley-Tukey algorithm for computing the l-d FFT lends itself to a particular matrix factorization which suggests direct implementation by linearly-connected systolic arrays. Here we present a new systolic architecture that embodies this algorithm. This implementation requires a smaller number of processors and a smaller number of memory cells than other recent implementations, as well as having all the advantages of systolic arrays. For the implementation of the decimation-in-frequency case, word-serial data input allows continuous real-time operation without the need of a serial-to-parallel conversion device. No control or data stream switching is necessary. Computer simulation of this architecture was done in the context of a 1024 point DFT with a fixed point processor, and CMOS processor implementation has started.

Boriakoff, Valentin↗

Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study

OBJECTIVES: The aim of this study was to use real-time three-dimensional echocardiography (3DE) to investigate the quantitative relation between minimal left ventricular (LV) outflow tract area (A(LVOT)) and maximal LV outflow tract (LVOT) velocity in patients with hypertrophic obstructive cardiomyopathy (HCM). BACKGROUND: In patients with HCM, LVOT velocity should change inversely with minimal A(LVOT) unless LVOT obstruction reduces the pumping capacity of the ventricle. METHODS: A total of 25 patients with HCM with systolic anterior motion (SAM) of the mitral valve leaflets underwent real-time 3DE. The smallest A(LVOT) during systole was measured using anatomically oriented two-dimensional "C-planes" within the pyramidal 3DE volume. Maximal velocity across LVOT was evaluated by two-dimensional Doppler echocardiography (2DE). For comparison with 3DE A(LVOT), the SAM-septal distance was determined by 2DE. RESULTS: Real-time 3DE provided unique information about the dynamic SAM-septal relation during systole, with A(LVOT) ranging from 0.6 to 5.2 cm(2) (mean: 2.2 +/- 1.4 cm(2)). Maximal velocity (v) correlated inversely with A(LVOT) (v = 496 A(LVOT)(-0.80), r = -0.95, p < 0.001), but the exponent (-0.80) was significantly different from -1.0 (95% confidence interval: -0.67 to -0.92), indicating a significant impact of small A(LVOT) on the peak LVOT flow rate. By comparison, the best correlation between velocity and 2DE SAM-septal distance was significantly (p < 0.01) poorer at -0.83, indicating the superiority of 3DE for assessing A(LVOT). CONCLUSIONS: Three-dimensional echocardiography-measured A(LVOT) provides an assessment of HCM geometry that is superior to 2DE methods. These data indicate that the peak LVOT flow rate appears to be significantly decreased by reduced A(LVOT). Real-time 3DE is a potentially valuable clinical tool for assessing patients with HCM.

NASA Discipline Cardiopulmonary↗

Dynamically Reconfigurable Systolic Array Accelerator

A polymorphic systolic array framework has been developed that works in conjunction with an embedded microprocessor on a field-programmable gate array (FPGA), which allows for dynamic and complimentary scaling of acceleration levels of two algorithms active concurrently on the FPGA. Use is made of systolic arrays and a hardware-software co-design to obtain an efficient multi-application acceleration system. The flexible and simple framework allows hosting of a broader range of algorithms, and is extendable to more complex applications in the area of aerospace embedded systems. FPGA chips can be responsive to realtime demands for changing applications needs, but only if the electronic fabric can respond fast enough. This systolic array framework allows for rapid partial and dynamic reconfiguration of the chip in response to the real-time needs of scalability, and adaptability of executables.

Dasu, Aravind↗

Relationship between early diastolic intraventricular pressure gradients, an index of elastic recoil, and improvements in systolic and diastolic function

BACKGROUND: Early diastolic intraventricular pressure gradients (IVPGs) have been proposed to relate to left ventricular (LV) elastic recoil and early ventricular "suction." Animal studies have demonstrated relationships between IVPGs and systolic and diastolic indices during acute ischemia. However, data on the effects of improvements in LV function in humans and the relationship to IVPGs are lacking. METHODS AND RESULTS: Eight patients undergoing CABG and/or infarct exclusion surgery had a triple-sensor high-fidelity catheter placed across the mitral valve intraoperatively for simultaneous recording of left atrial (LA), basal LV, and apical LV pressures. Hemodynamic data obtained before bypass were compared with those with similar LA pressures and heart rates obtained after bypass. From each LV waveform, the time constant of LV relaxation (tau), +dP/dt(max), and -dP/dt(max) were determined. Transesophageal echocardiography was used to determined end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fractions (EF). At similar LA pressures and heart rates, IVPG increased after bypass (before bypass 1.64+/-0.79 mm Hg; after bypass 2.67+/-1.25 mm Hg; P<0.01). Significant improvements were observed in ESV, as well as in apical and basal +dP/dt(max), -dP/dt(max), and tau (each P<0.05). Overall, IVPGs correlated inversely with both ESV (IVPG=-0.027[ESV]+3.46, r=-0.64) and EDV (IVPG=-0.027[EDV]+4.30, r=-0.70). Improvements in IVPGs correlated with improvements in apical tau (Deltatau =5.93[DeltaIVPG]+4.76, r=0.91) and basal tau (Deltatau =2.41[DeltaIVPG]+5.13, r=-0.67). Relative changes in IVPGs correlated with changes in ESV (DeltaESV=-0.97[%DeltaIVPG]+23.34, r=-0.79), EDV (DeltaEDV=-1.16[%DeltaIVPG]+34.92, r=-0.84), and EF (DeltaEF=0.38[%DeltaIVPG]-8.39, r=0.85). CONCLUSIONS: Improvements in LV function also increase IVPGs. These changes in IVPGs, suggestive of increases in LV suction and elastic recoil, correlate directly with improvements in LV relaxation and ESV.

Non-NASA Center↗

Systolic and diastolic time intervals in pulsus alternans - Significance of alternating isovolumic relaxation

Systolic and diastolic time intervals in 14 cardiac patients with pulsus alternans revealed significant alternation of preinjection period (PEP), isovolumic contraction time (IVCT), left ventricular ejection time (LVET), ejection time index (ETI), PEP/LVET, and carotid dD/dt with better functional values in the strong beats. Cycle length, duration of electromechanical systole (EMS) and total diastole, i.e., isovolumic relaxation period (IRP) and diastolic filling period (DFP) occurred in 7 out of 8 patients. These diastolic intervals alternated reciprocally such that the IRP of the strong beats encroached upon the DFP of the next (weak) beats.

Spodick, D. H.↗

Circuit for detecting initial systole and dicrotic notch

Circuitry is disclosed for processing an arterial pressure waveform to produce during any one cycle a pulse corresponding to the initial systole and a pulse corresponding to the dicrotic notch. In a first channel, an electrical analog of the arterial pressure waveform is filtered and then compared to the original waveform to produce an initial systole signal. In a second channel, the analog is differentiated, filtered, and fed through a gate controlled by pulses from the first channel to produce an electrical pulse corresponding to the dicrotic notch.

Gebben, V. D.↗

Constant-load versus heart rate-targeted exercise - Responses of systolic intervals

Various systolic intervals were measured prior to and during heart rate-targeted bicycle ergometer exercise. There were striking similarities within each matched exercise set for Q-Im, isovolumetric contraction time, preejection period (PEP), and PEP/left ventricular ejection time (LVET). LVET was significantly shorter for rate-targeted exercise. It is concluded that either constant-load or rate-targeted bicycle ergometry may be used with the choice of method determined by the purpose of the protocol, and that systolic intervals (except LVET) should not be much altered owing to the method chosen.

Lance, V. Q.↗

Pre- and postflight systolic time intervals during LBNP - The second manned Skylab mission

Before and after the 59 day Skylab 3 flight, the astronauts were stressed with lower body negative pressure (LBNP), and their vectorcardiograms, pneumograms, phonocardiograms, and carotid pulse tracings were monitored together with the intervals of systole. In the immediate postflight period elevations in heart rate and blood pressure were observed in response to -50 mm Hg of LBNP. Postflight abnormalities in the systolic time intervals (STI) at rest and during stress were due to an increase in afterload and a decrease in preload. As blood volume was restored and blood pressure reduced, STI abnormalities persisted as long as one month, suggesting a possible reduction in ventricular contractility and/or a functional impairment to venous return.

Bergman, S. A., Jr.↗