Search NASA⌕ Search

SEARCH · Search NASA

Results for “tank floor welding fabrication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Operational Parameter Database for Molten Salt Thermal Energy Storage Tank Modeling

The second generation of concentrated solar power (CSP) plants is characterized by the use of a central receiver (either cavity or external), two molten nitrate salt tanks (60 wt.% NaNO 3 and 40 wt.% KNO 3 ), and a steam Rankine power-generation cycle connected through a primary heat exchanger. Molten salt thermal energy storage (TES) tanks have been widely deployed in commercial CSP plants worldwide and have been essential for increasing plant dispatchability and capacity factor, while also reducing the levelized cost of electricity (LCOE). These systems enable energy storage at the gigawatt-hour scale, typically providing 6 to 17 hours of storage duration. Despite being a commercial technology, the multiple failures observed after only a few months or years of operation in plants around the world demonstrate the technology's relative infancy and highlight the need for further research to improve its reliability. The National Laboratory of the Rockies (NLR), in collaboration with industry partners and academic and research institutions, has been leading multiple projects funded by the U.S. Department of Energy (DOE). These projects focus on addressing molten salt tank failures by improving tank design and welding fabrication practices, evaluating new alloys and weld fillers, and providing guidelines for tank commissioning and safe operation. In particular, this report presents modeling results on the effect of key tank operation parameters during 60 minutes of operation, including the mass flow rate and temperature of the salt inflow, tank salt inventory temperature, and inventory level for a representative molten salt tank design. These results form a database of tank operation behaviors that captures the effects of each specific parameter during charging, charging/discharging, and discharging processes.

14 SOLAR ENERGY↗

Modeling of Stress Distribution in Molten Salt Thermal Energy Storage Tanks for In-Service Central Receiver Power Plants

Failures in molten nitrate salts thermal energy storage tanks (TES) have been occurring in several concentrating solar power (CSP) plants around the world after a few months or years of operation. These failures are mainly related to a combination of high stress, corrosion, large deformation, and thermal cycling. Most of these failures are a consequence of the infancy of this technology; technical standards for design, fabrication, implementation, and operation of molten salt tanks operating at temperatures up to 565 degrees Celsius do not exist and most of current in-service tanks have been designed using the recommendations from the American Petroleum Institute (API) 650 and the American Society of Mechanical Engineers ASME section II standards, which are applicable for TES tanks operating at lower temperatures. We have developed a 3-dimensional model of a representative molten salt hot tank design that uses typical CSP plant operation conditions and allows determining the temperature and stress distribution in the tank. The model also considers the initial floor residual stresses and distortion after its welding fabrication. We have identified critical thermal gradients in the tank floor and shell and locations in the tank where the stresses are high and could become susceptible points for failure.

concentrating solar power↗

Demonstration of How Manufacturing Innovations Challenge Conventional Structural Design

For almost 100 years, commercial aircraft have been fabricated using riveted aluminum alloy structures. Aside from refining aircraft designs for better aerodynamic efficiency, improving alloy compositions, and automating assembly steps, fuselage construction remains largely unchanged today. The intent of the lightweight metallic fuselage prototype undertaken in NASA’s Advanced Air Transport Technology project was to demonstrate innovative forming and joining processes that advance the design paradigm, i.e. achieve high-rate manufacturing and reduce assembly time/costs. Over the past decade, researchers at NASA Langley Research Center have evaluated the potential to modify the flow forming process to produce near-net shaped cylinders, integrally stiffened along the cylinder axis, for space launch vehicles. The production of integral stiffeners in a formed aluminum cylinder, the size of the Space Shuttle external tank, replaced machined thick plate and welding steps to eliminate > 500,000 pounds of machining chips and ~ 0.5 miles of welds. The flow forming method, called the Integrally Stiffened Cylinder (ISC) process, was successfully demonstrated up to the 10-foot diameter scale, which laid the groundwork for the current investigation of metallic fuselage structures. Using the ISC process as the basis for the re-design of a metallic fuselage eliminates hundreds of thousands of holes and rivets, while significantly reducing assembly time and crack initiation sites in the integral structure. However, the ISC process is not currently configured to fabricate circumferential ring frames for carrying fuselage internal pressure loads. Consequently, a trade study was performed to assess existing and advanced manufacturing processes, including additive manufacturing, forming, and welding. The approach with the lowest barriers to success, while simultaneously improving manufacturing time and cost, was to use formed ring frame segments attached to the ISC via Refill Friction Stir Spot Welding (RFSSW). The RFSSW process is five times faster than drilling, reaming, and riveting and provides similar mechanical performance. Finishing the fuselage structure with conventional windows, floor beams, and floor panels can then be accomplished using incumbent assembly methods, thereby maximizing reuse of existing infrastructure for aircraft construction. Structural analyses were performed to assess and optimize the geometric variables of integrated skin and stiffener configurations. A cost benefit and manufacturing rate analysis was also performed to compare against the current state-of-the-art for single aisle transport class aircraft. The resulting structure offers a weight reduction that rivals current graphite-epoxy composite fuselage structures. The projected manufacturing rate is close to double current metallic fuselages and six times faster than current composite manufacturing practices. The damage tolerance properties of a monocoque fuselage structure have yet to be assessed, but past integral airframe structural work has exploited geometric features to blunt or turn cracks. This concept offers promise that integrated structures can meet stringent aircraft durability specifications. An important benefit is that such aluminum fuselage structures may be inspected and repaired using established practices and existing expertise. Finally, pursuit of advanced manufacturing processes for future aluminum fuselages minimizes waste and the structure is 100% recyclable at the end-of-life for maximum sustainability.

aluminum↗