Evaluation of Second Target Station Target Streaming for the Preliminary Design of the Target Assembly
This report documents the analysis of dose rate fields from a combination of two sources stemming from the target system of the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) Second Target Station (STS). This analysis supports the target drive components’ lifetime estimates and conventional facilities’ preliminary design. The two sources detailed in this report are the radiation generated by the proton beam incident on the target and the activated cooling water in the pipes at the top of the target assembly. The analysis considers the STS target system in operational configuration, with all shielding in place. The dose rate fields are calculated in the target drive room and through the target drive room ceiling. This report calculates the thickness necessary for the target drive room’s high-density concrete ceiling to meet the 0.25 mrem/hr dose limit requirement in the high bay directly above the target drive room. In addition to sizing the target drive room ceiling, this report includes details of the dose field surrounding the target drive assembly to estimate the deposited dose in the target drive assembly components resulting from both streaming and decay of activated water. Prompt neutrons and gammas generated by the proton beam incident on the target primarily stream along the gaps between the target assembly and core vessel shielding. Because the models and analysis detailed in this report are based on the STS preliminary design, future analysis is needed to support the STS final design.