Black Drum Fish Teeth: Built for Crushing Mollusk Shells
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
An experimental test facility is used to measure the rotordynamic coefficients of teeth-on-rotor and teeth-on-stator labyrinth gas seals. Direct damping coefficients are presented for these seals for the first time. The results are presented for the two seal configurations at identical operating conditions, and show that, in a rotordynamic sense, the teeth-on-stator seal is more stable than the teeth-on-rotor seal, for inlet tangential velocity in the direction of rotation.
An experimental test facility is used to measure the rotordynamic coefficients of teeth-on-rotor and teeth-on-stator labyrinth gas seals. Direct damping coefficients are presented for these seals for the first time. The results are presented for the two seal configurations at identical operating conditions, and show that, in a rotordynamic sense, the teeth-on-stator seal is more stable than the teeth-on-rotor seal, for inlet tangential velocity in the direction of rotation.
Quantifying the chemical composition of fast-growing hard tissues in the environment can shed valuable information in terms of understanding ecosystems both prehistoric and current. Changes in chemical composition can be correlated with environmental conditions and can provide information about the organism's life. Sharks can lose 0.1 to 1.1 teeth/day, depending on species, which offers a unique opportunity to record environmental changes over a short duration of time. Shark teeth contain a biomineral phase that is made up of fluorapatite [Ca 5 (PO 4 ) 3 F], and the F distribution within the tooth can be correlated to tooth hardness. Typically, this is determined by bulk acid digestion, energy-dispersive X-ray spectroscopy (EDS), or wavelength-dispersive spectroscopy. Here we present laser-induced breakdown spectroscopy (LIBS) as an alternative and faster approach for determining F distribution within shark teeth. Using a two-volume laser ablation chamber (TwoVol3) with innovative embedded collection optics for LIBS, shark teeth were investigated from sand tiger (Carcharias Taurus), tiger (Galeocerdo Cuvier), and hammerhead sharks (Sphyrnidae). Fluorine distribution was mapped using the CaF 603 nm band (CaF, Β 2 Σ + → X 2 Σ + ) and quantified using apatite reference materials. In addition, F measurements were cross referenced with EDS analyses to validate the findings. Distributions of F (603 nm), Na (589 nm), and H (656 nm) within the tooth correlate well with the expected biomineral composition and expected tooth hardness. This rapid methodology could transform the current means of determining F distribution, particularly when large sample specimens (350 mm 2 , presented here) and large quantities of specimens are of interest.
Abstract Chiton articulatus is a species of mollusk living in the tropical Pacific intertidal rocky shores of Mexico. This species feeds on solid waste organic sources, including hard crustose algae that grow on rocky substrates, by grazing on them with its radula, a flexible chitinous membrane lined with mineralized major lateral teeth. In this study, the composition, morphology, and resulting mechanics of the mature teeth of this species, which have yet to be examined, are revealed. The results show the presence of multiphasic mature teeth, each consisting of aligned hard magnetite nanoparticles on the leading edge of the tooth underneath which are magnetite lamellae, followed by goethite, lepidocrocite, and eventually hydroxyapatite near the trailing edge. This multiregional structure demonstrates a gradation in hardness as well as different microstructural features integrated with tough interfaces. The combination of these microstructural and phase arrangements results in an abrasion‐resistant tough structure with a self‐sharpening ability. The results of this work will help contribute to developing new bioinspired designs while also helping to understand the evolution and feeding habits of these intriguing invertebrates.
Biological organisms naturally synthesize complex, hierarchical, multifunctional materials through mineralization processes at ambient conditions and under physiological pH. One such example is the ultrahard and wear-resistant radular teeth found in mollusks, which are used to scape against the rock to feed on algae. Herein, the biologically controlled structural development of the hard, outer magnetite-containing shell of the chitin teeth is revealed. Specifically, the formation of a series of mesocrystalline iron oxide phases, templated by chitin-binding proteins, is identified. The initial domains, consisting of ferrihydrite mesocrystals with a spherulite-like morphology, undergo a solid-state phase transformation to form magnetite while maintaining mesocrystallinity, likely via a shear-induced solid-state reaction, without any noticeable architectural changes. Subsequent growth via Ostwald ripening leads to nearly single-crystalline rod-like elements. In addition, an interpenetrating organic matrix is identified that, at early stages of tooth development, potentially contains iron-binding proteins that guide the self-assembly of the mesocrystalline mineral and influence the preferred orientation of the later-formed magnetite nanorods, which ultimately determines the mechanical behavior of the mature chiton teeth.
This is the Final Technical Report for the TEETH project. The TEETH concept couples high-temperature solar-thermochemical water splitting (TCWS) with electrochemical H 2 pumping through a proton conducting membrane (PCM) and capitalizes on the benefits of the individual technologies to synergistically providing new benefits. That is, TEETH is a coupled thermochemical/electrochemical process to produce H 2 from steam using solar energy. This approach is thermodynamically equivalent to other hybrid electrolytic processes but is unique in that the equilibrium of the reaction is driven forward by close coupling an electrically driven proton-conducting-membrane to the H 2 -producing reoxidation step. The process uniquely provides and benefits from the necessary H 2 /steam separation and, also unlike other hybrid processes, benefits thermodynamically from the use of readily generated high pressure steam. The concept also satisfies the objectives of previous concepts: 1) decreasing the reduction enthalpy (the reduction temperature), of the working metal-oxide (MO); 2) eliminating the need for a windowed receiver; and 3) widening the scope of material candidates, while also obviating the need for electrical connections to the working MO and avoiding the use of aqueous electrolytes and hydrated redox species (there is no liquid phase), without increasing mechanical complexity.
The design of a gear mesh is treated with the objective of minimizing the gear size for a given gear ratio, pinion torque, pressure angle, and allowable tooth lengths. Tooth strengths considered include scoring, pitting fatigue, and bending fatigue. Kinematic involute interference is avoided. The design variation on standard spur gear teeth called the long and short addendum system, is considered. In this system the mesh center distance and pressure angle are maintained as is the ability to manufacture the teeth with standard tooling. However, the pinion and gear tooth proportions are altered in order to obtain fewer teeth numbers for the same ratio as standard gears without kinematic involute interference. The effect of this nonstandard gearing geometry with on tooth strengths and gear mesh size are studied. For a 2:1 gearing ratio, the optimal nonstandard gear design is compared with the optimal standard gear design.
Contact stresses in meshing spur gear teeth are examined. The analysis is based upon an incremental finite element procedure that simultaneously determines the stresses in the contact region between the meshing teeth. The teeth themselves are modeled by two dimensional plain strain elements. Friction effects are included, with the friction forces assumed to obey Coulomb's law. The analysis assumes that the displacements are small and that the tooth materials are linearly elastic. The analysis procedure is validated by comparing its results with those for the classical two contacting semicylinders obtained from the Hertz method. Agreement is excellent.
Internal spur gear teeth are normally stronger than pinion teeth of the same pitch and face width since external teeth are smaller at the base. However, ring gears which are narrower have an unequal addendum or are made of a material with a lower strength than that of the meshing pinion may be loaded more critically in bending. In this study, a model for the bending strength of an internal gear tooth as a function of the applied load pressure angle is presented which is based on the inscribed Lewis constant strength parabolic beam. The bending model includes a stress concentration factor and an axial compression term which are extensions of the model for an external gear tooth. The geometry of the Lewis factor determination is presented, the iteration to determine the factor is described, and the bending strength J factor is compared to that of an external gear tooth. This strength model will assist optimal design efforts for unequal addendum gears and gears of mixed materials.
Much like keeping your teeth clean, where you brush away biofilms that your dentist calls "plaque," there are various methods to clean spaceflight hardware of biological contamination, known as biological reduction processes. Different approaches clean your hardware's "teeth" in different ways and with different levels of effectiveness. We know that brushing at home with a simple toothbrush is convenient and has a different level of impact vs. getting your teeth cleaned at the dentist. In the same way, there are some approaches to biological reduction that may require simple tools or more complex implementation approaches (think about sonicating or just soaking your dentures, vs. brushing them). There are also some that are more effective for different degrees of cleanliness and still some that have materials compatibility concerns. In this article, we review known and NASA-certified approaches for biological reduction, pointing out materials compatibility concerns and areas where additional research is needed.
Much like keeping your teeth clean, where you brush away biofilms that your dentist calls plaque, there are various methods to clean spaceflight hardware of biological contamination, known as biological reduction processes. Different approaches clean your hardwares teeth in different ways and with different levels of effectiveness. We know that brushing at home with a simple toothbrush is convenient and has a different level of impact vs. getting your teeth cleaned at the dentist. In the same way, there are some approaches to biological reduction that may require simple tools or more complex implementation approaches (think about sonicating or just soaking your dentures, vs. brushing them). There are also some that are more effective for different degrees of cleanliness and still some that have materials compatibility concerns. In this article, we review known and NASA-certified approaches for biological reduction, pointing out materials compatibility concerns and areas where additional research is needed.
The meshing of beveled gears was studied by the direct and inverse approaches. Gear wheels with teeth of equal height are studied, and wheels with normally-decreasing arc teeth. Different coordinate systems are utilized to plot the determination of the rotation of the originating gear wheel and the meshing line of the gear wheel which is cut. Matrices are used to determine the equations of the originating surfaces and the unit vectors of the normals to these originating surfaces.
A procedure for computer aided design (CAD) of gear teeth is presented. It is developed for generated teeth fabricated by a hob cutter or a shaper. It provides a means for analytically and numerically determining the tooth profile, given the cutter profile. An illustrative example with involute tooth profiles is given. Application with non-standard profiles and with bevel, spiral bevel, and hypoid gears is discussed.
A computer code, FLEXM, was developed to calculate the flexibility matrices of contacting teeth for spiral bevel gears using a simplified analysis based on the elementary beam theory for the deformation of gear and shaft. The simplified theory requires a computer time at least one order of magnitude less than that needed for the complete finite element method analysis reported earlier by H. Chao, and it is much easier to apply for different gear and shaft geometries. Results were obtained for a set of spiral bevel gears. The teeth deflections due to torsion, bending moment, shearing strain and axial force were found to be in the order 10(-5), 10(-6), 10(-7), and 10(-8) respectively. Thus, the torsional deformation was the most predominant factor. In the analysis of dynamic load, response frequencies were found to be larger when the mass or moment of inertia was smaller or the stiffness was larger. The change in damping coefficient had little influence on the resonance frequency, but has a marked influence on the dynamic load at the resonant frequencies.
The restoration of the cutting edge on hob teeth may be controlled by precise positioning of the laser spot. In experiments, the microstructure after laser surfacing and quenching is analyzed by means of metallographic data.
The influence of the cutting conditions on the life of quadrilateral cutting heads in the rough cutting of conical gears with circular teeth is investigated experimentally.
Measurement of the curved surface finish on gear teeth is made by a device used in conjunction with a conventional profilometer.