Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of High-Temperature SiPM Noise

Introduction • Background: Silicon photomultipliers (SiPMs) are compact, low-power, and high-efficiency detectors that are increasingly used in radiation detection applications like medical imaging and nuclear safeguards. The have advantages of PMTs because they are smaller, operate at lower voltages, and offer high photon detection efficiency. • Challenges: SiPMs suffer from increased dark count rate (DCR) and optical crosstalk (OCT), which degrades performance. • Purpose of study: This study compares the Advansid ASD-NUV3S-P-40, Broadcom AFBR-S4K33C0147L, and Onsemi MicroFJ-30035-TSVTR under four different temperatures to compare their performance in harsh environments.

Fritchie, Jacob↗

Two-tooth bosonic quantum comb for temporal-correlation sensing

We introduce a two-tooth bosonic quantum comb that captures the sequential interactions between a thermal absorber and a long-lived coherent probe. The comb provides a causal, multi-time description of coherence transport, tracking how the probe records both instantaneous fluctuations and their temporal correlations. Using a process-tensor formulation, we derive closed form expressions showing that interference between the two interaction windows generates a non-monotonic memory response that reflects a fundamental competition between the absorbers thermal population and its dynamical correlations. By sweeping the temporal separation between the interaction windows, the probe directly samples the absorbers population correlator, enabling bosonic noise spectroscopy that discriminates Markovian temperature noise from slow or spectrally structured fluctuations. The approach is readily compatible with circuit-QED platforms and offers a general method for probing fluctuating bosonic environments.

Zhu, Shaojiang [Fermilab]↗

ADMX Axion Dark Matter Bounds around 3.3 μ eV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability

We report the results of a QCD axion dark matter search with discovery ability for Dine-Fischler-Srednicki-Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultralow noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 μ eV , assuming a standard halo model with a local energy density of 0.45 G e V / cm 3 made up 100% of axions. Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accounting for uncertainty sources in pyrometric measurements: Variables affecting Surface Temperature measurements using the LLNL Streak Spectrometers

Here we present a detailed analysis of the error sensitivities of the LLNL temperature analysis package used in analyzing streak spectrometer data. These sensitivities include noise, temperature, wavelength, emissivity, missing bands, and missing data points. The analysis package was tested for its ability to accurately reconstruct randomly generated noisy data and found to perform within specifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

W-band system-on-chip electron cyclotron emission imaging system on DIII-D

Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shot-noise-induced lower temperature limit of the nonneutral plasma parallel temperature diagnostic

Abstract We develop a new algorithm to estimate the temperature of a nonneutral plasma in a Penning-Malmberg trap. The algorithm analyzes data obtained by slowly lowering a voltage that confines one end of the plasma and collecting escaping charges, and is a maximum likelihood estimator based on a physically-motivated model of the escape protocol presented in (Beck in Measurement of the magnetic and temperature dependence of the electron-electron anisotropic temperature relaxation rate. PhD thesis, 1990). Significantly, our algorithm may be used on single-count data, allowing for improved fits with low numbers of escaping electrons. This is important for low-temperature plasmas such as those used in antihydrogen trapping. We perform a Monte Carlo simulation of our algorithm, and assess its robustness to intrinsic shot noise and external noise. The assumptions in this paper allow for a lower bound for measurable plasma temperatures of approximately $3\,\mathrm{K}$ 3 K for plasmas of length $1\,\mathrm{cm}$ 1 cm , with approximately 100 particle counts needed for an accuracy of $\pm 10 \%$ ± 10 % .

Zhong, Adrianne (ORCID:0000000162618736)↗

Temperature Dependence of Low‐Frequency Noise Characteristics of NiO x /β‐Ga 2 O 3 p–n Heterojunction Diodes

Temperature dependence of the low-frequency electronic noise in NiO x /β-Ga 2 O 3 p–n heterojunction diodes is reported. The noise spectral density is of the 1/f-type near room temperature but shows signatures of Lorentzian components at elevated temperatures and at higher current levels (f is the frequency). It is observed that there is an intriguing non-monotonic dependence of the noise on temperature near T = 380 K. The Raman spectroscopy of the device structure suggests material changes, which results in reduced noise above this temperature. The normalized noise spectral density in such diodes is determined to be on the order of 10 −14 cm 2 Hz −1 (f = 10 Hz) at 0.1 A cm −2 current density. In terms of the noise level, NiO x /β-Ga 2 O 3 p–n diodes perform excellently for new technology and occupy an intermediate position among devices of various designs implemented with different ultra-wide-bandgap semiconductors. The obtained results are important for understanding the electronic properties of NiO x /β-Ga 2 O 3 heterojunctions and contribute to the development of noise spectroscopy as the quality assessment tool for new electronic materials and device technologies.

1/f noise↗

Seismic Ambient Noise Analyses Reveal Changing Temperature and Water Signals to 10s of Meters Depth in the Critical Zone

The critical zone sustains terrestrial life, but we have few tools to explore it efficiently beyond the first few meters of the subsurface. Using analyses of high-frequency ambient seismic noise from densely spaced seismometers deployed in the forested Shale Hills subcatchment of the Susquehanna Shale Hills Critical Zone Observatory (SSHCZO), we show that temporal changes in seismic velocities at depths from ~1 m to tens of m can be detected. Furthermore, these changes are driven by variations at the land surface. The Moving-Window Cross-Spectral (MWCS) method was employed to measure seismic-velocity changes in coda waves at hourly resolution in 10 different frequency bands. We observed a diurnal signal, a seasonal signal, and a meteorological-event-based signal. These signals were compared to time-series measurements of precipitation, well water levels, soil moisture, soil temperature, air temperature, latent heat flux, and air pressure in the heavily instrumented catchment. Most of the velocity changes can be explained by variations in temperature that result in thermoelastic strains that propagate to depth. But some double minima in seismic velocity time-series observed after large rain events were attributed in part to the effects of water infiltration. These results show that high-frequency ambient noise data may in some locations be used to detect changes in the critical zone from ~1 to ~100 m or greater depth with hourly resolution. But interpretation of such data requires multiple environmental data sets to deconvolve the complex interrelationships among thermoelastic and hydrological effects in the subsurface critical zone.

54 ENVIRONMENTAL SCIENCES↗

Low-Frequency Electronic Noise in Quasi-2D van der Waals Antiferromagnetic Semiconductor FePS 3 —Signatures of Phase Transitions

Here, low-frequency current fluctuations, i.e., noise, in the quasi-2D van der Waals antiferromagnetic semiconductor FePS 3 with the electronic bandgap of 1.5 eV is investigated. The electrical and noise characteristics of the p-type, highly resistive, thin films of FePS 3 are measured at different temperatures. The noise spectral density is of the 1/f-type over most of the examined temperature range but reveals well-defined Lorentzian bulges, and increases strongly near the Néel temperature T N =118 K (f is the frequency). Intriguingly, the noise spectral density attains its minimum at temperature T≈200 K, which is attributed to an interplay of two opposite trends in noise scaling—one for semiconductors and another for materials with the phase transitions. The Lorentzian corner frequencies reveal unusual dependence on temperature and bias voltage, suggesting that their origin is different from the generation—recombination noise in conventional semiconductors. The obtained results are important for proposed applications of antiferromagnetic semiconductors in spintronic devices. They also attest to the power of the noise spectroscopy for monitoring various phase transitions.

36 MATERIALS SCIENCE↗

Performance Test of Mini LVDT - ELVIS

The Institute for Energy (IFE) Technology has been a pioneer in the development of Linear Variable Differential Transformers (LVDTs) for in-pile testing, deploying over 2,200 units in various reactor environments with less than a 10% failure rate after five years of operation. This report focuses on the performance testing of IFE’s Mini LVDT, a compact sensor ideal for material test reactor experiments. The Mini LVDT, with a limited range of +/- 1.5 mm, offers excellent performance comparable to larger LVDTs, making it valuable in space-constrained applications. The development of an Enhanced Linear Variable Intrinsic Sensor (ELVIS) with internal temperature monitoring capabilities represents a significant advancement, addressing the critical need for real-time, accurate measurements in high-radiation and high-temperature environments. Two ELVIS prototypes were evaluated in terms of both temperature and displacement, showcasing promising results, though challenges with noise during temperature measurements were identified. This report summarizes the rigorous testing performed at Idaho National Laboratory (INL) and highlights the potential applications of Mini LVDTs and ELVIS in nuclear and other high-precision industries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low-frequency noise characteristics of GaN vertical PIN diodes—Effects of design, current, and temperature

We report low-frequency noise characteristics of vertical GaN PIN diodes, focusing on the effects of the diode design, current, and temperature. The as-grown and regrown diodes, with and without surface treatment, have been studied. The noise in most of the GaN devices had a characteristic 1/f spectrum at high and moderate currents, while some devices revealed generation-recombination bulges at low currents (f is the frequency). The predominant trend of the noise spectral density, S I , dependence on the current was S I ~ I. All tested GaN PIN diodes had rather low normalized noise spectral densities of 10 –18 –10 –16 cm 2 /Hz (f = 10 Hz) at the current density J = 1 A/cm 2 at room temperature. The noise temperature dependences at different currents revealed peaks at T = 375–400 K. Temperature, current, and frequency dependences of noise suggest that the noise mechanism is of the recombination origin. Here, we argue that the noise measurements at low currents can be used to efficiently assess the quality of GaN PIN diodes.

36 MATERIALS SCIENCE↗