Search NASA⌕ Search

SEARCH · Search NASA

Results for “tensile properties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Elevated temperature mechanical properties and residual tensile properties of two cast superalloys and several nickel-base oxide dispersion strengthened alloys

The elevated temperature tensile, stress-rupture and creep properties and residual tensile properties after creep straining have been determined for two cast superalloys and several wrought Ni-16Cr-4Al-yttria oxide dispersion strengthened (ODS) alloys. The creep behavior of the ODS alloys is similar to that of previously studied ODS nickel alloys. In general, the longitudinal direction is stronger than the long transverse direction, and creep is at least partially due to a diffusional creep mechanism as dispersoid-free zones were observed after creep-rupture testing. The tensile properties of the nickel-base superalloy B-1900 and cobalt-base superalloy MAR-M509 are not degraded by prior elevated temperature creep straining (at least up to 1 pct) between 1144 and 1366 K. On the other hand, the room temperature tensile properties of ODS nickel-base alloys can be reduced by prior creep strains of 0.5 pct or less between 1144 and 1477 K, with the long transverse direction being more susceptible to degradation than the longitudinal direction.

Whittenberger, J. D.↗

Space environmental effects on graphite-epoxy compressive properties and epoxy tensile properties

This study characterizes the effects of electron radiation and temperature on a graphite-epoxy composite material. Compressive properties of the T300/934 material system were obtained at -250 F (-157 C), room temperature, and 250 F (121 C). Tensile specimens of the Fiberite 934 epoxy resin were fabricated and tested at room temperature and 250 F (121 C). Testing was conducted in the baseline (nonirradiated) and irradiated conditions. The radiation exposure was designed to simulate 30 year, worst-case exposure in geosynchronous Earth orbit. Mechanical properties tended to degrade at elevated temperature and improve at cryogenic temperature. Irradiation generally degraded properties at all temperatures.

Fox, Derek J.↗

Effects of Long-Term Thermal Exposure on Commercially Pure Titanium Grade 2 Elevated-Temperature Tensile Properties

Elevated-temperature tensile testing of commercially pure titanium (CP Ti) Grade 2 was conducted for as-received commercially produced sheet and following thermal exposure at 550 and 650 K (531 and 711 F) for times up to 5000 h. The tensile testing revealed some statistical differences between the 11 thermal treatments, but most thermal treatments were statistically equivalent. Previous data from room temperature tensile testing was combined with the new data to allow regression and development of mathematical models relating tensile properties to temperature and thermal exposure. The results indicate that thermal exposure temperature has a very small effect, whereas the thermal exposure duration has no statistically significant effects on the tensile properties. These results indicate that CP Ti Grade 2 will be thermally stable and suitable for long-duration space missions.

Ellis, David L.↗

Exploring biofiber properties and their influence on biocomposite tensile properties

Biofibers serve as effective reinforcements for neat polylactic acid (PLA) in biocomposites, offering an attractive opportunity to decarbonize the manufacturing sector of the United States by displacing fossil-based reinforcement fibers such as carbon fibers. Also, biofiber production can stimulate economic growth in rural economies, fueling sustainable development. PLA resins are commonly compounded with biofibers to create biocomposites suitable for additive manufacturing. PLA-biofiber composites often exhibit better overall material properties than neat (pure) PLA, but the associations between biofiber properties and the material properties of their biocomposites remain largely unexplored. Hence, this research delves into a comprehensive exploration of diverse biofibers, scrutinizing their physical and chemical attributes, including size, shape, ash content and biochemical composition. The study meticulously analyzes the flow properties of each biofiber and elucidates the ultimate tensile strengths and Young's modulus of corresponding biocomposite samples. Noteworthy correlations between biofiber and biocomposite tensile properties are uncovered, shedding light on critical interrelationships. The study introduces an approach employing regression models to predict the ultimate tensile strength and Young's modulus of biocomposites. These models, validated with a cross-validation technique, exhibit remarkable predictive accuracy, particularly in estimating ultimate tensile strength. © 2024 Oak Ridge National Laboratory managed by UT-Battelle, LLC and The Author(s). Polymer International published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.

36 MATERIALS SCIENCE↗

Comparison of Elevated Temperature Tensile Properties and Fatigue Behavior of Two Variants of a Woven SiC/SiC Composite

Tensile properties (elastic modulus, proportional limit strength, in-plane tensile strength, and strain at failure) of two variants of a woven SiC/SiC composite, manufactured during two separate time periods (9/99 and 1/01), were determined at 1038 and 1204 C by conducting tensile tests on specimens machined from plates. Continuous cycling fatigue tests (R = 0.05) and 20 cpm) were also conducted at the same two temperatures on specimens from both composites. In this study, average tensile properties, 95% confidence intervals associated with the tensile properties, and geometric mean fatigue lives of both composite materials are compared. The observed similarities and differences in the tensile properties are highlighted and an attempt is made to understand the relationship, if any, between the tensile properties and the fatigue behaviors of the two woven composites.

Kalluri, Sreeramesh↗

Structural and High-Temperature Tensile Properties of Special Pitch-Coke Graphites

The room-temperature structural properties and the tensile properties up to 5000 F (275O C) were determined for ten grades of specially prepared petroleum-coke coal-tar-pitch graphites which were graphitized at 5430 F (3000 C). One impregnation with coal-tar pitch increased the bulk density from 1.41 to 1.57 g/cm3 and the maximum strength at 4500 F (2500 C) from 4000 to 5700 psi. None of the processing parameters studied had a marked effect on the closed porosity or the X-ray structure or the per cent graphitization. The coarse-particle filler resulted in the lowest coefficient of thermal expansion and the fine-particle filler in the highest coefficient. A marked improvement in uniformity of tensile strength was observed. A standard-deviation analysis gave a one-sigma value of approximately 150 psi for one of these special grades and values of 340-420 psi for three commercial grades.

GRAPHITE↗

Effect of Thermal Exposure on the Tensile Properties of Aluminum Alloys for Elevated Temperature Service

Tensile properties were evaluated for four aluminum alloys that are candidates for airframe applications on high speed transport aircraft. These alloys included the Al-Cu-Mg-Ag alloys C415 and C416 and the Al-Cu-Li-Mg-Ag alloys RX818 and ML377. The Al-Cu-Mg alloys CM001, which was used on the Concorde SST, and 1143, which was modified from the alloy used on the TU144 Russian supersonic aircraft, were tested for comparison. The alloys were subjected to thermal exposure at 200 F, 225 F and 275 F for times up to 30,000 hours. Tensile tests were performed on thermally-exposed and as-received material at -65 F, room temperature, 200 F, 225 F and 275 F. All four candidate alloys showed significant tensile property improvements over CM001 and 1143. Room temperature yield strengths of the candidate alloys were at least 20% greater than for CM001 and 1143, for both the as-received and thermally-exposed conditions. The strength levels of alloy RX818 were the highest of all materials investigated, and were 5-10% higher than for ML377, C415 and C416 for the as-received condition and after 5,000 hours thermal exposure. RX818 was removed from this study after 5,000 hours exposure due to poor fracture toughness performance observed in a parallel study. After 30,000 hours exposure at 200 F and 225 F, the alloys C415, C416 and ML377 showed minor decreases in yield strength, tensile strength and elongation when compared to the as-received properties. Reductions in tensile strength from the as-received values were up to 25% for alloys C415, C416 and ML377 after 15,000 hours exposure at 275 F.

Edahl, Robert A., Jr.↗

High-temperature tensile properties of fiber reinforced reaction bonded silicon nitride

Measurements of tensile properties of unidirectional silicon carbide fiber-reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens were carried out in air at 25, 1300, and 1500 C, using a new testing technique and a specially designed gripping system that minimizes bending moment and assures that failure always occurred in the gage section. The material was found to display metallike stress-strain behavior at all temperatures tested, and a noncatastrophic failure beyond the matrix fracture. The tensile properties were found to be temperature dependent, with the values of the ultimate tensile strength decreasing with temperature, from 543 MPa at 25 C to 169 at 1500 C.

Jablonski, David A.↗

Off-axis tensile properties and fracture in a unidirectional graphite/polyimide composite (Celion 6000/PMR 15)

Tensile properties of unidirectional Celion 6000 graphite/PMR 15 polyimide composites prepared by hot molding and cold molding processes were measured at room temperature and 316 C, the upper use temperature of the polyimide resin, at both 45 and 90 deg to the fiber axis. The resulting fractures were characterized by scanning electron microscopy and materialographic techniques. Variation in tensile properties with processing history occurred in the elastic modulus and strain to failure for specimens loaded at 90 deg at 316 C, and in the fracture stress, and hence the in-plane shear stress, for those loaded at 45 deg at room temperature. Significant plastic deformation was observed in the 45 deg orientation at 316 C for material produced by both processing methods. In general, fracture occurred by both failure within the matrix and at the fiber-matrix interface; the degree of interfacial failure increased with temperature. Secondary cracking below the primary fracture surface was also observed.

Harper, J.↗

Dataset of tensile properties for sub-sized specimens of nuclear structural materials

Mechanical testing with sub-sized specimens plays an important role in the nuclear industry, facilitating tests in confined experimental spaces with lower irradiation levels and accelerating the qualification of new materials. The reduced size of specimens results in different material behavior at the microscale, mesoscale, and macroscale, in comparison to standard-sized specimens, which is referred to as the “specimen size effect.” Although analytical models have been proposed to correlate the properties of sub-sized specimens to standard-sized specimens, these models lack broad applicability across different materials and testing conditions. The objective of this study is to create the first large public dataset of tensile properties for sub-sized specimens used in nuclear structural materials. We performed an extensive literature review of relevant publications and extracted over 1,000 tensile testing records comprising 55 columns including material type and composition, manufacturing information, irradiation conditions, specimen dimensions, and tensile properties. The dataset can serve as a valuable resource to investigate the specimen size effect and develop computational methods to correlate the tensile properties of sub-sized specimens.

36 MATERIALS SCIENCE↗

The effect of strain rate and temperature on the tensile properties of NiAl

Tensile testing of cast and extruded binary NiAl was performed from 300 to 900 K at strain rates of 0.00014 to 0.14/s. The brittle-to-ductile transition temperature (BDTT) was dependent on strain rate, with a three-order-of-magnitude increase in strain rate resulting in approximately a 200-K increase in transition temperature. Regardless of strain rate, at temperatures just above the BDTT the fracture strength increased significantly and the fracture morphology changed from mostly intergranular to predominantly transgranular. It was also determined that the mechanism responsible for the brittle-to-ductile transition in NiAl had an apparent activation energy of approximately 118 kJ/mol. These results support the argument that the mechanism for the brittle-to-ductile transition in NiAl is associated with the onset of thermally activated deformation process. This process is probably dislocation climb controlled by short circuit diffusion.

Noebe, R. D.↗

Effect of copper-rich regions on tensile properties of VPPA weldments of 2219-T87 aluminum

This study examines the relations between tensile properties and microstructural features of variable polarity plasma arc (VPPA) weldments of 2219-T87 aluminum. Crack initiation and weld failure of transverse tensile specimens of single and multipass weldments were studied. The specimens fractured on the rising portion of the stress-strain curve prior to necking, signifying that an increase in strength would accompany an increase in ductility. Of particular interest is a shallow, typically 0.001-0.003-in. (0.03-0.08-mm) deep, copper-rich region located in the crown and root corners of the weld. This region is a primary source of crack initiation and growth, due to its brittle nature and highly strained location. The brittle regions were removed by electropolishing and machining to determine their effect on weld tensile properties. The removal increased the ductility of the weld specimens, and in the case of single pass welds, actually increased the load carrying capacity. Local strain measurements and metallographic and chemical analyses are presented.

Hartman, J. A.↗

Tensile properties of the neutron irradiated HT-9 ACO-3 duct

HT-9, a ferritic-Martensitic steel, has attracted significant interest as a structural and cladding material for a variety of high dose nuclear component applications. This study examines the tensile properties of a HT-9 fuel assembly duct from the fast flux test facility, FFTF. The duct, from the Advanced Core Oxide-3 (ACO-3) irradiation test, was subjected to fast neutron irradiation exposure ranging from 3 dpa above the core top to nearly 155 dpa near the core mid-plane, spanning a temperature range from 382 °C at the lower end to 504 °C at the top. Due to the combination of thermal and neutron flux gradients along the core height. This yields a variety of irradiation damage processes which depend on core location. Tensile properties of specimens extracted at different positions along the height of the irradiated duct were measured at 25 °C, 200 °C and near their in-core irradiation temperature. The results show temperature has a greater impact than dose on post-irradiation strength and ductility. Two irradiation temperature regimes were determined, below irradiation temperatures of 420 °C irradiation hardening increases as irradiation temperature decreases, and above that temperature relatively minor changes are observed in tensile properties. These results are discussed in terms of expected microstructural changes, indicating that dislocation content is a strong contributor in these findings.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tensile properties of SiC/aluminum filamentary composites - Thermal degradation effects

Aluminium metal matrix composites with a low cost fiber, e.g. SiC, provide for an attractive combination of high elastic modulus and longitudinal strengths coupled with a low density. SiC (volume fraction 0.55)-aluminum (6061) systems have been studied in order to optimize fiber composite strength and processing parameters. A comparison of two SiC/aluminum composites produced by AVCO and DWA is provided. Fiber properties are shown to alter composite tensile properties and fracture morphology. The room temperature tensile strengths appear to be insensitive to thermal exposures at 500 C up to 150 h. The elastic modulus of the composites also appears to be stable up to 400 C, however variations in the loss modulus are apparent. The fracture morphology reflects the quality of the interfacial bond, fiber strengths and fiber processing.

Skinner, A.↗

Effect of Electron Beam Irradiation on the Tensile Properties of Carbon Nanotubes Sheets and Yarns

Carbon nanotube sheets and yarns were irradiated using electron beam (e-beam) energy to determine the effect of irradiation dose on the tensile properties. Results showed that a slight change in tensile strength occurred after irradiating as-received CNT sheets for 20 minutes, and a slight decrease in tensile strength as the irradiation time approached 90 minutes. On the other hand, the addition of small molecules to the CNT sheet surface had a greater effect on the tensile properties of e-beam irradiated CNT sheets. Some functionalized CNT sheets displayed up to a 57% increase in tensile strength following 90 minutes of e-beam exposure. In addition, as-received CNT yarns showed a significant increase in tensile strength as the irradiation time increased.

Williams, Tiffany S.↗