Search NASA⌕ Search

SEARCH · Search NASA

Results for “tensile testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Brittle fracture in a 50Mo-50Re alloy during slow strain rate tensile testing

Tensile tests were conducted on 50 wt% Mo-50 wt% Re alloys, in fully-recrystallized and recovery heat-treated conditions respectively, at a very low strain rate of 10 -6 s -1 and room temperature in air. It was found that both these alloys exhibited predominantly cleavage fracture with significant intergranular secondary cracking, compared to the predominantly ductile fracture found in the alloys at a higher strain rate. Cracks were often initiated at grain boundary triple junctions at the low strain rate. Electron back scatter diffraction (EBSD) measurements revealed significantly high misorientation gradients at grain boundaries, especially in the vicinity of some grain boundary triple junctions in the deformed alloys. Transmission electron microscopic (TEM) results verified the existence of significant misorientation taking place at grain boundaries in these alloys. Furthermore, wtress-assisted dynamic embrittlement, possibly due to trace interstitials, was the possible cause for the occurrence of brittle fracture in the 50Mo-50Re alloys at the low strain rate.

36 MATERIALS SCIENCE↗

Tensile Testing of Generation II FeCrAl Tubing

FeCrAl tubing is being developed as an improved accident tolerant cladding material for light water reactor fuels. A very promising generation FeCrAl alloy, C26M, is not being produced in long tubing for future reactor testing. In this report, the results of two FeCrAl tubes are presented. Tubes from two different heats of C26M are tested. Tensile tests were conducted in air at room temperature, 300 °C, and 600 °C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer

A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.

47 OTHER INSTRUMENTATION↗

Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer

A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.

42 ENGINEERING↗

Beam current effect as a potential challenge in SEM-EBSD in situ tensile testing

Highlights: • In situ SEM-EBSD tensile tests were conducted using 304L steels with 8 and 10.4% Ni. • KAM and GROD evolution, twinning, and phase instability were investigated. • Phase transformation in 8% Ni-steel was sensitive to the electron beam current. In situ mechanical tensile tests coupled with electron backscatter diffraction (EBSD) analysis were conducted using specimens of two 304L steels with ~8 and 10.4% Ni content, respectively. Twinning was observed in steel with 10.4% Ni content, whereas steel with 8% Ni content demonstrated martensitic transformation. Testing showed that the kinetics of martensitic transformation in steel with 8% Ni content was influenced by the electron beam current used during EBSD scans. Continuous scanning using 32 nA nominal beam current led to suppression of the phase instability in the near-surface layer, but acceptable comparable-to-the-bulk results were obtained using 8 nA beam current. The exact mechanism of the beam current role is unclear, but it appears to be neutral regarding Kernel Average Misorientation behavior and deformation-induced twinning.

36 MATERIALS SCIENCE↗

Testing Tensile and Shear Epoxy Strength at Cryogenic Temperatures

This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass.

multilayer insulation↗

Testing Tensile and Shear Epoxy Strength at Cryogenic Temperatures

This paper covers cryogenic, tensile testing and research completed on a number of epoxies used in cryogenic applications. Epoxies are used in many different applications; however, this research focused on the use of epoxy used to bond MLI standoffs to cryogenic storage tanks and the loads imparted to the tank through the MLI. To conduct testing, samples were made from bare stainless steel, aluminum and primed aluminum. Testing involved slowly cooling test samples with liquid nitrogen then applying gradually increasing tensile loads to the epoxy. The testing evaluated the strength and durability of epoxies at cryogenic temperatures and serves as a base for future testing. The results of the tests showed that some epoxies withstood the harsh conditions while others failed. The two epoxies yielding the best results were Masterbond EP29LPSP and Scotch Weld 2216. For all metal surfaces tested, both epoxies had zero failures for up to 11.81 kg of mass..

epoxy↗

Strength, Hardening, and Failure Observed by In Situ TEM Tensile Testing: Strength, Hardening, and Failure Observed by In Situ TEM Tensile Testing

We present in situ transmission electron microscope tensile tests on focused ion beam fabricated single and multiple slip oriented Cu tensile samples with thicknesses in the range of 100–200 nm. Both crystal orientations fail by localized shear. While failure occurs after a few percent plastic strain and limited hardening in the single slip case, the multiple slip samples exhibit extended homogenous deformation and necking due to the activation of multiple dislocation sources in conjunction with significant hardening. The hardening behavior at 1% plastic strain is even more pronounced compared to compression samples of the same orientation due to the absence of sample taper and the interface to the compression platen. Moreover, we show for the first time that the strain rate sensitivity of such FIB prepared samples is an order of magnitude higher than that of bulk Cu.

36 MATERIALS SCIENCE↗

In-situ tensile testing of single-crystal molybdenum-alloy fibers with various dislocation densities in a scanning electron microscope

In-situ tensile tests have been performed in a dual beam focused ion beam and scanning electron microscope on as-grown and prestrained single-crystal molybdenum-alloy (Mo-alloy) fibers. The fibers had approximately square cross sections with submicron edge lengths and gauge lengths in the range of 9–41 μm. In contrast to previously observed yield strengths near the theoretical strength of 10 GPa in compression tests of ~1–3-μm long pillars made from similar Mo-alloy single crystals, a wide scatter of yield strengths between 1 and 10 GPa was observed in the as-grown fibers tested in tension. Deformation was dominated by inhomogeneous plastic events, sometimes including the formation of Lüders bands. In contrast, highly prestrained fibers exhibited stable plastic flow, significantly lower yield strengths of ~1 GPa, and stress–strain behavior very similar to that in compression. A simple, statistical model incorporating the measured dislocation densities is developed to explain why the tension and compression results for the as-grown fibers are different.

36 MATERIALS SCIENCE↗

An in situ tensile test apparatus for polymers in high pressure hydrogen

Degradation of material properties by high-pressure hydrogen is an important factor in determining the safety and reliability of materials used in high-pressure hydrogen storage and delivery. Hydrogen damage mechanisms have a time dependence that is linked to hydrogen outgassing after exposure to the hydrogen atmosphere that makes ex situ measurements of mechanical properties problematic. Designing in situ measurement instruments for high-pressure hydrogen is challenging due to known hydrogen incompatibility with many metals and standard high-power motor materials like Nd. Here we detail the design and operation of a solenoid based in situ tensile tester under high-pressure hydrogen environments up to 5,000 psi. Here, modulus data from high-density polyethylene (HDPE) samples tested under high-pressure hydrogen are also reported as compared to baseline measurements taken in air.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A numerical and experimental approach to compare the effect of sample thickness in small in-situ SEM and large ex-situ tensile testing in Alloy 709

ASTM standards for tensile tests define specific sample size requirements regardless of grain size of the material. However, sample size requirements for testing should be considered in conjunction with the number of grains within its reduced cross-sectional area. This is particularly important for in-situ Scanning Electron Microscope (SEM) tensile tests, as they have to be conducted on smaller samples. In this study, a comprehensive experimental and numerical evaluation of the effect of specimen thickness (and the resulting number of grains within the cross-section) were conducted using in-situ SEM tensile test (on submillimeter thick samples) and ex-situ tensile tests (on samples of 0.68–5.9 mm thickness) and the results are compared with FEM simulations outcome. All tests were conducted at room temperature and the results are correlated to the number of grains within the thickness of specimens. The tensile test results indicated that even though the 0.2% proof stress and the tensile strength do not vary for the current range of thicknesses (with number of grains in the cross-section varying from 13 to 118), a difference in necking mechanism exists. Post tensile strength, thinner samples undergo more shear failure and diagonal localized necking whereas thicker samples experience more diffuse necking indicated by decreased area of shear failure at the edges and increased area of dimpled tensile failure at the center of the sample. Further, FEM results complement the experimental findings by showing the formation of conjugated localized shear bands on the upper and lower surface in the 0.68 mm thick sample and shear bands combining to form singular shear bands in thicker samples. These results also confirm the validity of the in-situ SEM tensile tests conducted on thinner samples as long as the required minimum number of grains exist within the cross-section.

36 MATERIALS SCIENCE↗

Swab Tensile Testing and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, unless otherwise noted. The FormLabs-USF and FormLabs-Northwell were printed at LLNL using FormLabs Surgical Grade V1 Resin on a Form 3B Printer. Results Summary: All FormLabs design and treatment variations (e.g. autoclaving and “aging”) had higher tensile strength compared commercial swabs. Autoclaving degraded the tensile strength. “Aging” after autoclaving improved the tensile strength. “Aging” without autoclaving degraded the tensile strength. No differences were observed in tensile strength with different autoclaving protocols. No significant differences were observed in tensile strength for different batches.

59 BASIC BIOLOGICAL SCIENCES↗

A novel indirect tensile test method to measure the biaxial tensile strength of concretes and other quasibrittle materials

A novel indirect tensile test method, the biaxial flexure test (BFT) method, has been developed to measure the biaxial tensile strength of concretes. The classical modulus of rupture (MOR) test has been generalized to three dimensions. In this method, we use a circular plate as the new test specimen. This plate is supported by an annular ring. We apply an external load to this specimen through a circular edge. The centers of the specimen, the loading device and the support are identical. The biaxial tensile strength measured by this new method is about 19% greater than the uniaxial tensile strength obtained from the classical modulus of rupture test as reported by other researchers. However, at the same time, we also found that the stochastic deviation of the biaxial tensile strength is about 63% greater than the uniaxial strength.

36 MATERIALS SCIENCE↗

Swab Tensile Testing Results and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the “Aged” swabs. For the “Aged” swabs, the tensile tests were performed 7 days after the Autoclave pre -treatment. All swabs were provided by HP.

36 MATERIALS SCIENCE↗

Swab Tensile Testing Results and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the Injection Molded samples. For the Injection Molded samples, the tensile tests were performed within 24 hours of the completion of the Autoclave pre-treatment. The FormLabs-USF and FormLabs-Northwell were printed at LLNL using FormLabs Surgical Grade V1 Resin on a Form 3B Printer. All other samples were provided by HP.

36 MATERIALS SCIENCE↗

Mechanical properties of neutron irradiated F82H using micro-tensile testing

Room temperature micro-tensile tests were successfully performed on F82H specimens neutron-irradiated at 573 K up to 5 dpa and unirradiated using a focused ion beam (FIB) device. Dimensions of the gauge section for micro-tensile specimens were about 10 µm (length) × 1 µm2 (area). These specimens were fabricated in a FIB device. The tensile properties obtained on specimens of micrometer size qualitatively agreed with results from millimeter size specimens. Using this micro-tensile testing technique is considered to become very useful data in combining the micro-tensile data on ion irradiated F82H with data on neutron irradiated material. This method overcomes the limitation on obtaining mechanical property on ion irradiated specimens to only micro-indentation testing.

Ando, Masami↗

Size Effect Studies on Tensile Tests for Hot Stamping Steel

Tensile tests have been widely used to determine basic mechanical properties of materials. However, the properties measured may be related to geometrical factors of the tested samples especially for high-strength steels; this makes the properties’ definitions and comparisons difficult. In this study, a series of tensile tests of ultra-high-strength hot-stamped steel were performed; the geometric shapes and sizes as well as the cutting direction were modified. The results demonstrate that the hot-stamped parts were isotropic and the cutting direction had no effect; the measured strengths were practically unrelated to the specimen geometries, including both size and shape. The elongations were slightly related to sample sizes within the studied range but highly depended on the sample shape, represented by the coefficient K. Such phenomena were analyzed and discussed based on microstructural observations and fracture morphologies. Moreover, two widely used elongation conversion equations, the Oliver formula and Barba’s law, were introduced to verify their applicability, and a new interpolating function was developed and compared.

36 MATERIALS SCIENCE↗