Search NASA⌕ Search

SEARCH · Search NASA

Results for “test and evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multi-Axis Resonant Plate Shock Testing Evaluation and Test Specification Development

Resonant plate testing is a shock test method that is frequently used to simulate pyroshock events in the laboratory. Recently, it was discovered that if the unit under test is installed at an off-center location, a tri-axial accelerometer would record a shock response in three directions and the resulting shock response spectra implied that the test may have qualified the component in three directions simultaneously. The purpose of this research project was to evaluate this idea of multi-axis shock testing to determine if it was truly a multi-axis shock environment and if such a test could be used as an equivalent component qualification test. A study was conducted using generic, additively manufactured components tested on a resonant plate, along with an investigation of plate motion to evaluate the component response to off- center plate excitation. The data obtained here along with the analytical simulations performed indicate that off-center resonant plate tests are actually not three-axis shock tests, but rather single axis shocks at an arbitrary angle dictated by the location of the unit under test on the plate. This conclusion is supported by the fact that only one vectored shock input is provided to the component in a resonant plate test. Thus, the output response is a coupled response of the transverse plate vibration and the rotational motion of the component on the plate. Additionally, a multi-axis shock test defined by three single axis test environments always results in a significant component over-test in one direction.

42 ENGINEERING↗

Solar Technology Test, Evaluation, and Data Collection: Cooperative Research and Development Final Report, CRADA Number CRD-08-279

Under this Agreement, NREL will work with Abengoa Solar Inc. on the testing, evaluation, and collection of data related to Abengoa Solar Inc. solar technologies and systems. This work includes, but is not limited to, testing and evaluation of solar component and system technologies, data collection and monitoring, performance evaluation, reliability testing, thermal energy storage integration, solar resource measurement and forecasting, grid impact testing, and analysis. This work will be conducted at NREL, SolarTAC (Aurora), and other field test locations.

14 SOLAR ENERGY↗

The Structural Evaluation Test Unit (SETU) Benchmark Test Results

A series of extensively instrumented tests was performed on the Structural Evaluation Test Unit in the early 1990s. The purpose of these tests was to determine the response of a minimally designed cask to impacts that were more severe than the design basis impact. This test series provides an excellent opportunity for benchmarking explicit dynamic finite element analysis programs for behaviors that may be experienced by casks during regulatory and extra-regulatory impact events. This report provides the results of the four tests that were conducted. It is meant to go along with a companion report that defines the benchmark problem and gives the locations for the instrumentation and inspection points.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Structural Evaluation Test Unit (SETU) Benchmark Problem Statement

A series of extensively instrumented tests was performed on the Structural Evaluation Test Unit in the early 1990s. The purpose of these tests was to determine the response of a minimally designed cask to impacts that were more severe than the design basis impact. This test series provides an excellent opportunity for benchmarking explicit dynamic finite element analysis programs for behaviors that may be experienced by casks during regulatory and extra-regulatory impact events. This report provides the parameters of the test unit, the locations of instrumentation, the locations of inspection points, and the parameters of the four tests that were conducted. A companion report provides the results of the tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Module Level Exposure and Evaluation Test (MLEET) for Real- world and Laboratory-based PV Modules: Common Data and Analytics for Quantitative Cross-correlation and Validation

Our objective is to develop a set of lifetime performance prediction models for PV modules. Models were developed based on common I-V, P mp datastreams from modules under outdoor (real-world) exposure and indoor (laboratory-based) accelerated exposures and temporal analytics. These common datastreams that span both indoor and outdoor exposures were supplemented with additional information such as meteorology data, climate and PV module make/model and module specifications. The predictive models were developed using a stressor/mechanism/response framework in which all data are categorized as stressor, mechanism or performance variables and are represented as time-series datastreams. We develop and validate these accelerated indoor exposures and evaluation tests and models and cross-correlate the temporal signatures of PV module degradation mechanisms in the I-V, P mp time-series between outdoor and accelerated indoor tests. The predictive test and model specify indoor and outdoor exposure and data acquisition criteria, variable selection, and temporal duration and variance.

14 SOLAR ENERGY↗

SDU6 Interior Liner Testing & Evaluation

Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warping or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SDU7 Interior Liner Testing & Evaluation

The Saltstone Disposal Unit 7 (SDU7) project requested the Savannah River National Laboratory (SRNL), Materials Science & Engineering (MS&E) organization to evaluate an alternative bromobutyl liner and adhesives for potential use in SDU7 based on applicable ASTM testing standards. SRNL performed similar testing for the liner system used in SDU6. Bonded and non-bonded samples of the alternative liner (Blair Rubber Marflex™ RCHB60HT) were subjected to specific ASTM tests after immersion in two Saltstone leachate simulants, designated S1 and S2, for 1000 hours at 60 °C. Immersion exposures were performed at the Savannah River Ecology Laboratory (SREL). Post-immersion testing involved mechanical property and hardness testing of base material, lap-shear testing of bonded samples and rubber-to-concrete paver interrogation. The liner exhibited an approximate 40% drop in tensile strength and 25% drop in elongation at failure from baseline values after immersion, though final values are comparable to previous SDU6 liner values and are within liner manufacturer property ranges. Overall lap-shear strength behavior of the four adhesives showed a similar pattern, with short-term reduction and subsequent increase in peak load values. However, ranking of adhesives varied with the metric used for comparison. Two of the four adhesives tested (Normac 900 and REMA SC 4000) showed overall better behavior, collectively considering immersion performance, lap-shear data and bonded paver interrogation. Lap-shear samples bonded with the REMA adhesive showed the best combination of final retained bond strength, 6-week average bond strength and bond failure mode. Only one paver (REMA SC4000) was noted to have no defects after immersion. This document details the testing performed and provides conclusions and recommendations. The testing suggests that SDU liner performance is highly dependent upon seam integrity, which collectively depends on a combination of adhesive properties, installation workmanship and inspection/quality control.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beam test evaluation of electromagnetic calorimeter modules made from proton-damaged PbWO 4 crystals

The performance of electromagnetic calorimeter modules made of proton-irradiated PbWO 4 crystals has been studied in beam tests. The modules, similar to those used in the Endcaps of the CMS electromagnetic calorimeter (ECAL), were formed from 5×5 matrices of PbWO 4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between 2.1 × 10 13 and 1.3 × 10 14 cm –2 . These correspond to the predicted charged-hadron fluences in the ECAL Endcaps at pseudorapidity η = 2.6 after about 500 fb –1 and 3000 fb –1 respectively, corresponding to the end of the LHC and High Luminosity LHC operation periods. The irradiated crystals have a lower light transmission for wavelengths corresponding to the scintillation light, and a correspondingly reduced light output. A comparison with four crystals irradiated in situ in CMS showed no significant rate dependence of hadron-induced damage. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The latter is interpreted, through comparison with simulation, as a side-effect of the degradation in light transmission. In conclusion, the experimental results obtained can be used to estimate the long term performance of the CMS ECAL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Counter Unmanned Aerial Systems Testing: Evaluation of VIS SWIR MWIR and LWIR passive imagers.

This report contains analysis of unmanned aerial systems as imaged by visible, short-wave infrared, mid-wave infrared, and long-wave infrared passive devices. Testing was conducted at the Nevada National Security Site (NNSS) during the week of August 15, 2016. Target images in all spectral bands are shown and contrast versus background is reported. Calculations are performed to determine estimated pixels-on-target for detection and assessment levels, and the number of pixels needed to cover a hemisphere for detection or assessment at defined distances. Background clutter challenges are qualitatively discussed for different spectral bands, and low contrast scenarios are highlighted for long-wave infrared imagers.

47 OTHER INSTRUMENTATION↗