Using Test Configuration Transmissibility Functions to Limit Shock Responses
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The poster presentation prepared for the IOTA (Integrable Optics Test Accelerator) Pre-Bake Test Development project consists of introducing the background of the project, the work completed, and the new test configurations available with the newly designed assembly. It explains the scale of the projects, both within the IOTA ring assembly and test assembly, and describes the purpose in baking or incrementing and holding exterior heat on the beampipe to reduce impurities in the vacuum. The originally designed test, Configuration One, uses RCA scans on the interior of the pipe, increments and holds heat for a set amount of time, and is scanned again to check for water evaporation. Configuration Two begins with the same test for Configuration One but has a second cross section of beampipe separated by a gate valve. After configuration one is complete, the gate valve opens, and after a period of cooling the other side is heated, molecular movement is scanned and observed.
As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.
As part of the U.S. Department of Energy's EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High power charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. EVSE characterization was conducted over a wide range of DC output current and DC voltage charging for nominal and off-nominal test conditions. Test plans and procedures were developed and refined to define the test configurations and requirements, measurement parameters, and test procedures used throughout NextGen Profiles testing.
Device durability remains a significant challenge in photoelectrochemical (PEC) water splitting under ambient conditions. Yet, a lack of understanding of the test configuration and applied bias effects continue to hinder progress. In this study, we differentiate two-electrode (2E) and three-electrode (3E) configurations for evaluating PEC material durability, focusing particularly on their impacts on photoabsorber solid-state operating conditions. Our results underscore the fallacy of inferring 2E device stability from durability measurements performed solely in 3E configurations. Unmeasured and often misunderstood total circuit bias in 3E tests moderates material degradation, leading to the overestimation of photoelectrode stability compared to short-circuit operation. We demonstrate how the photoabsorber's operating voltage critically governs charge separation, surface stability, and degradation mechanisms during PEC operation. With these findings, we propose a standardized framework for conducting more reliable 3E durability experiments that simulate unassisted performance to help accelerate the development of robust, stable materials for solar-driven water splitting.
This work investigates the potential induced degradation-polarization (PID-p) of bifacial passivated emitter and rear contact (PERC) modules installed in the field at the Florida Solar Energy Center. 22 modules were stressed over 1 year under various voltage (-1500V, -3500, +1500V) and mounting configurations (close to ground, 2 meters from ground, close to roof). The positively stressed modules were anticipated to have experiences PID-p on their front side. However, no degradation was observed, as the light-induced recovery effect effectively counteracted the degradation. The negatively stressed modules experienced Pmax drops during 2 weeks before stabilizing at 5-6% loss. I-V and EL characteristics suggest a PID-p degradation on the rear side. Lower degradation rates are observed with lower voltage and when the mounting configuration allows more albedo light on the rear side to compensate for the degradation. PID-p is observed to stabilize at similar level for the voltage and mounting configuration tested with slightly lower Pmax in winter. EL imaging reveals that cells are not degrading at the same rate across a module. Some cells get darker and then brighter which corresponds to the silicon/passivation interface going through depletion and then inversion when enough positive charges are accumulated. After full light-recovery, the modules were tested again along with 22 brand-new ones to assess the impact of the module history. Results confirmed the trends observed in the first year with PID-p occurring at voltage as low as -600V and recovered modules degrading faster than brand-new ones.
Here, the spout-bed fluidization behavior of nonspherical, 140 μm SiC feedstock was quantified via particle image velocimetry for varying gas distributor geometries. A bench-scale, room-temperature fluidization setup was assembled to model a 50 mm fluidized bed chemical vapor deposition (FB-CVD) system, and fluidized bed motion was captured using a high-speed camera. Modular tips with varying inlet geometries were 3D printed and tested on the bench-scale rig using identical feedstock and gas flow rates in the range of 3.0–9.0 L/min. Fluidization behavior was quantified by extracting parameters of the bed velocity, frequency, dead time, and other measurements, which were ranked for each inlet geometry configuration tested. The results from this work demonstrate that changing the path of inlet gas flow can significantly change the hydrodynamics within a spout-fluidized bed under identical feedstock, loading, and flow rate conditions, potentially enabling experimental control of particle fluidization behavior for a given condition. Moreover, composite rankings of fluidization behavior for unique distributor geometries hold potential to guide the design of FB-CVD experiments for various engineering and scientific applications.
Magnetic geometry has a significant effect on the level of turbulent transport in fusion plasmas. Here, we model and analyse this dependence using multiple machine learning methods and a dataset of >200 000 nonlinear gyrokinetic simulations of ion-temperature-gradient turbulence in diverse non-axisymmetric geometries. The dataset is generated using a large collection of both optimised and randomly generated stellarator equilibria. At fixed gradients and other input parameters, the turbulent heat flux varies between geometries by several orders of magnitude. Trends are apparent among the configurations with particularly high or particularly low heat flux. Regression and classification techniques from machine learning are then applied to extract patterns in the dataset. Due to a symmetry of the gyrokinetic equation, the heat flux and regressions thereof should be invariant to translations of the raw features in the parallel coordinate, similar to translation invariance in computer vision applications. Multiple regression models including convolutional neural networks (CNNs) and decision trees can achieve reasonable predictive power for the heat flux in held-out test configurations, with highest accuracy for the CNNs. Using Spearman correlation, sequential feature selection and Shapley values to measure feature importance, it is consistently found that the most important geometric lever on the heat flux is the flux surface compression in regions of bad curvature. The second most important geometric feature relates to the magnitude of geodesic curvature. These two features align remarkably with surrogates that have been proposed based on theory, while the methods here allow a natural extension to more features for increased accuracy. The dataset, released with this publication, may also be used to test other proposed surrogates, and we find that many previously published proxies do correlate well with both the heat flux and stability boundary.
The aim of this study is to analyze the stability of helical Alfvén eigenmodes (HAEs) in TJ-II discharges and the stabilizing effect of the energetic particles generated by the neutral beam injector (NBI) on pressure gradient-driven modes (PGDMs). HAE and PGDM stability is studied using the linear version of the gyro-fluid code FAR3d and the continuous structure by the STELLGAP code. First, Alfvén eigenmode (AE) and PGDM activity observed in the experiments is reproduced by the simulations, identifying unstable m/n = 4/7 − 2/3 and 7/12 − 5/8 HAEs triggered around ρ = 0.66 showing a frequency of 209 and 204 kHz, respectively, as well as 5/3 PGDM. Next, a parametric study is performed with respect to the thermal ion density and iota profile in the middle-outer plasma region to verify the robustness of the simulation results with respect to the uncertainty of experimental profiles. The analysis confirms that experimental uncertainty does not cause large deviations in the simulation results, showing the destabilization of the same HAEs for all the configurations tested. The simulations also indicate the decay of the 5/3 PGDM growth rate as the energetic particle (EP) population in the plasma increases, consistent with the experiment. Stability analysis of the n = 3, 7, 11, n = 5, 9, 13, n = 6, 10, 14, and n = 8, 12 helical families is performed with respect to the NBI operational regime for different EP energies, β as well as deposition profiles. The most unstable configuration is the radially localized on-axis NBI operation (stiff EP density profile gradients nearby the magnetic axis). Using the simulation model that reproduces the observed Alfvén activity, we extend the study to analyze NBI performance within a theoretical framework. It shows that increasing NBI voltage (which raises EP energy) leads to a degradation in NBI performance for a given power (related to EP β and their density). To achieve better NBI operation, higher voltage must be balanced with lower injection power, ensuring stable AEs while keeping the same EP β.
A series of critical experiments were designed involving the use of characterized graphite elements in the new plate-type core of the IPEN/MB-01 reactor. Eleven configurations with different graphite quantities are considered, each producing distinct effects on neutron fluxes and offering opportunities to analyze varying sensitivities to k eff in the system. The analysis shows that the experiments can be performed with acceptably low k eff uncertainties considering an adequate characterization of the graphite elements to be used. The sensitivity results obtained using SCALE TSUNAMI calculations show that the experiments have a notable k eff sensitivity coefficient to graphite. In the configurations tested, the k eff sensitivity to graphite TSL is low. This experiment will be useful for criticality safety validation of applications using uranium fuel enriched to around 19.75 wt % 235 U, light water and graphite. It will also be useful to gain more insight into graphite material properties and their effect on k eff as a result of using the well-characterized graphite elements. The execution of the experiments is planned for the summer of 2025. The 11 designed configurations serve as a basis for the final design, and fewer configurations will be executed. Once executed, these critical experiments will be evaluated and submitted for publication in the International Criticality Safety Benchmark Evaluation Project Handbook, supporting the DOE/NRC Collaboration for Criticality Safety Support for Commercial-Scale HALEU for Fuel Cycles and Transportation project goal.
In this work, we investigated non-equilibrium plasma produced by nanosecond repetitively pulsed glow discharges applied across a lean premixed methane-air flame. The flame is stationary, axisymmetric, and laminar. The discharges are applied on the symmetry axis crossing the reactant gases, flame front, and product gases, allowing phase-locked averaged measurements and comparisons with axisymmetric numerical simulations. The thermal effect and methyl radical production are quantified in the discharge in the reactant gas region. One-dimensional, two-beam, hybrid, femtosecond-picosecond, coherent anti-Stokes Raman scattering is used to acquire spatial and temporal profiles of temperature and oxygen-to-nitrogen concentration ratio. Photo-fragmentation laser-induced fluorescence is used to acquire quantitative two-dimensional profiles of methyl radicals in the discharge providing the first quantitative imaging of methyl produced ahead of a flame by plasma-induced methane dissociation. The spatial profiles of temperature and oxygen-to-nitrogen concentration ratio are in steady state, indicating that individual discharges have an insignificant heating effect. Upper and lower bounds of the produced mole fraction of methyl radicals in the plasma are obtained due to uncertainties in the collisional quenching rates of excited state methylidyne radicals in the plasma. The discharges produce a maximum of 600–1100 ppm of methyl radicals upstream of the flame front within 25 ns. This amount is similar to the predicted methyl mole fraction for the flame without plasma and thus represents a significant chemical perturbation to the reactants upstream of the flame front. The produced methyl follows an exponential decay in the first microsecond after the discharge with a decay constant of 8 µs close to the flame, and 0.8 µs further from the flame. The decay then deviates from the exponential curve and the methyl persists for tens of microseconds. The results suggest that for the tested configuration, the thermal effect of individual discharges through fast gas heating is negligible, while active chemical species are produced in large quantities in the reactant gases, upstream of the flame front.
For fiscal year (FY) 2023, the Savannah River National Laboratory (SRNL) focused on two experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of solids on the tanks’ inner sidewalls and bottoms. Differences in the conductivity between various layers of the tank (e.g., solids, liquid, etc.) could result in differences in the electrochemical potential of the tank metal at various locations. The electrochemical potential difference may result in a corrosion current between the coupled surfaces. In FY23, SRNL investigated test configurations and protocols that could evaluate the presence of a galvanic couple between the tank bottom and the tank wall.
The first set of Thermal/Epithermal eXperiments (TEX) with chlorine absorbers (TEX-Cl) were executed in Q4FY24 and are in the process of being benchmarked for the ICSBEP. TEX-Cl builds upon the TEX-HEU baseline cases that were published in the 2022 International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. TEX-HEU, like TEX-Pu, was designed to be modular to allow for the incorporation of various absorbers and reflectors to test nuclear data and application case needs. For example, TEX-HEU with hafnium (TEX-Hf) utilizes hafnium plates as both absorbers and reflectors, depending on the tested configuration. A second set of chlorine experiments, dubbed More TEX-Cl, are laid out in this report to meet the needs of TerraPower for chlorine validation for their Molten Chloride Fast Reactor (MCFR) systems. TerraPower’s Molten Chloride Reactor Experiment (MCRE) and MCFR are fast molten salt reactors that utilize sodium chloride (NaCl) salt eutectics as the fuel and coolant. The MCRE eutectic is a mixture of NaCl and uranium trichloride (UCl 3 ). An abundant need for chlorine absorption validation has been expressed by multiple members of the community, including Y-12 (whose needs were addressed with the first set of experiments), LANL (whose needs were addressed with the Chlorine Worth Study (CWS)), TerraPower, institute de radioprotection et de sûreté nucléaire (IRSN), Savannah River Nuclear Solutions (SNRS), and others. Of the members who have expressed interest in this validation, most are interested in the fast neutron energy region, where the 35 Cl(n,p) reaction is most prominent. New 35 Cl(n,p) differential cross section measurements performed by LANL at LANCSE show substantial changes to the cross sections (Figure 1) and may be validated through these experiments as some configurations are optimally sensitive to this cross section.
The purpose of this document is to define the process for validation and verification (V&V) of software used to test the thermal data acquisition equipment in the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP) as part of the testing configuration(s). This process adheres to all applicable ORNL Standards Based Management System requirements and correlates with the PTP Quality Management System and the Software Quality Assurance Plan.
The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.
Computer simulation studies have been performed to understand the beam behavior and to explore intensity limitations of proton beams in the AGS Booster at higher beam intensities. During the 100 GeV polarized proton operations of RHIC Run 2024, sPHENIX operated in modes with a crossing angle at collisions in order to mitigate beam-beam effects. Three different running modes were employed: (a) sPHENIX operated with a negative (-2 mrad) crossing angle, and STAR operated with 0 mrad. Both experiments were brought into collisions at the start of the store. (b) sPHENIX was brought into collisions with 0 mrad first. Then STAR was brought into collisions after the beam-beam parameter from sPHENIX reduced to below $10 \times 10^{-3}$. (c) sPHENIX operated with a positive (+1.5 mrad) crossing angle, and STAR operated with 0 mrad. Both experiments were brought into collisions at the start of the store. The collisions with a crossing angle of up to $\pm 2$ mrad, as in running modes (a) and (c), lead to large Piwinski angle in the new sPHENIX detector, which reduces luminosity if other parameters are unchanged. There are two ways to compensate the reduction in luminosity: squeeze $\beta^{*}$ if there is sufficient dynamic aperture, or increase the injected beam intensity. The first part of polarized proton operation during RHIC Run 2024 was dedicated to increasing the intensity. Different configurations were tested with crossing angle and lattice adjustments on RHIC. At the same time, new injector configurations were developed and tested in an effort to push for both higher intensity and better quality of the beam injected into RHIC. When the beam intensity is increased, space charge is a concern particularly in the lower energy stages of acceleration, such as during the injection and the early part of the Booster cycle, which could become a dominant effect in limiting the intensity of the beam that can be delivered to RHIC.
Argonne National Laboratory’s (ANL) Mechanism Engineering Test Loop (METL) team has completed the design of a new Bearing Test Article (BTA) to test mechanical bearings for sodium fast reactor (SFR) mechanism applications. Recognition of the need for further bearing testing arose due to failure of rolling element bearings during testing of components for in-vessel fuel handling machines (FHMs) conducted at ANL in the METL facility. While the initial concept of the BTA arose from a need for bearing testing for FHM applications, the BTA design is configurable to test bearings of various sizes, types, and materials submerged in liquid sodium. Requirements for loading, shaft speed, temperature, and bearing size range were chosen based on requirements for SFR fuel handling. Modular components in the test bearing housings and shaft sleeves allow the design to accommodate a wide range of bearing sizes without modification to the larger assembly. Loading will be applied with screw jacks on the air side of the test article that will be adjusted to apply radial, thrust, or combined loading conditions. Applied force will be measured by load cells in-line with the loading mechanisms. In FY25 we have completed the design of the test article that will be fabricated and undergo testing at the METL facility. Drawing packages for the fabrication of the test article have been drafted and are being reviewed to add part tolerances and we have started ordering off-the-shelf components. The report will summarize the development of the Bearing Test Article design starting with an overview of the entire test article, then a more detailed examination of the bearing test section, loading mechanisms, test article ports and seals, and support structures, including analysis that went into significant design choices.
Additive manufacturing (AM) allows for manufacturing of complex three-dimensional geometries not typically realizable with standard manufacturing practices. The internal microstructure of AM components has a significant impact on mechanical, vibrational, and shock properties and permits richer design space when this is controllable. Due to complex interactions of internal geometry of an extrusion-based AM component, it is common practice to assume homogeneous behavior or to perform characterization testing on specific toolpath configurations. To avoid testing or material waste, it is necessary to develop a consistently accurate numerical simulation framework with relevant boundary value problems that can handle the complicated geometry of internal material microstructure present in AM components. Herein, a framework is proposed to directly create computational meshes suitable for finite element analysis (FEA) of the fine-scale features generated from extrusion-based AM tool paths to maintain a strong process–structure–property-performance linkage. This mesh can be manually or automatically analyzed using standard FEA simulations such as quasi-static preloading or modal analysis. The framework allows an in-silico assessment of a target AM geometry where fine-scale features greatly impact quantities of design interest such as in soft elastomeric lattices where toolpath infill can greatly influence the self-contact of a structure in compression, which we use as a motivating exemplar. This approach greatly reduces both time and resource waste present in traditional build and test design cycles for non-intuitive design spaces, and acts as a tool for use in the production of a key component of a digital twin, a mesh suitable for finite element analysis. In conclusion, it also further allows for the exploration of toolpath infill to optimize component properties beyond simple linear properties such as density and stiffness.