Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing methodology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hardware-in-the-Loop Test Bed and Test Methodology for Microgrid Controller Evaluation

Increasing penetration levels of distributed energy resources are making the deployment of microgrids more feasible. Controllers that operate such microgrids are key to realizing the objectives of the microgrid owner or operator and there is a need to evaluate microgrid controller performance prior to field deployment. This paper describes a controller hardware-in-the-loop and power hardware-in-the-loop microgrid controller test bed that was designed and constructed to evaluate the capabilities of a microgrid controller for a proposed campus microgrid. This paper also presents a test methodology to evaluate microgrid controller functionality, and it describes how the controller was assessed through the application of different test scenarios. Results from the testing are presented to provide insight into the capabilities of the test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Test Methodology for Determining Space-Readiness of Xilinx SRAM-Based FPGA Designs

Using reconfigurable, static random-access memory (SRAM) based field-programmable gate arrays (FPGAs) for space-based computation has been an exciting area of research for the past decade. Since both the circuit and the circuit's state is stored in radiation-tolerant memory, both could be alterd by the harsh space radiation environment. Both the circuit and the circuit's state can be prote cted by triple-moduler redundancy (TMR), but applying TMR to FPGA user designs is often an error-prone process. Faulty application of TMR could cause the FPGA user circuit to output incorrect data. This paper will describe a three-tiered methodology for testing FPGA user designs for space-readiness. We will describe the standard approach to testing FPGA user designs using a particle accelerator, as well as two methods using fault injection and a modeling tool. While accelerator testing is the current 'gold standard' for pre-launch testing, we believe the use of fault injection and modeling tools allows for easy, cheap and uniform access for discovering errors early in the design process.

97 MATHEMATICS AND COMPUTING↗

Poster - 44: Development and implementation of a comprehensive end-to-end testing methodology for linac-based frameless SRS QA using a modified commercial stereotactic anthropomorphic phantom

Purpose: An end-to-end testing methodology was designed to evaluate the overall SRS treatment fidelity, incorporating all steps in the linac-based frameless radiosurgery treatment delivery process. The study details our commissioning experience of the Steev (CIRS, Norfolk, VA) stereotactic anthropomorphic head phantom including modification, test design, and baseline measurements. Methods: Repeated MR and CT scans were performed with interchanging inserts. MR-CT fusion accuracy was evaluated and the insert spatial coincidence was verified on CT. Five non-coplanar arcs delivered a prescription dose to a 15 mm spherical CTV with 2 mm PTV margin. Following setup, CBCT-based shifts were applied as per protocol. Sequential measurements were performed by interchanging inserts without disturbing the setup. Spatial and dosimetric accuracy was assessed by a combination of CBCT hidden target, radiochromic film, and ion chamber measurements. To facilitate film registration, the film insert was modified in-house by etching marks. Results: MR fusion error and insert spatial coincidences were within 0.3 mm. Both CBCT and film measurements showed spatial displacements of 1.0 mm in similar directions. Both coronal and sagittal films reported 2.3 % higher target dose relative to the treatment plan. The corrected ion chamber measurement was similarly greater by 1.0 %. The 3 %/2 mm gamma pass rate was 99% for both films Conclusions: A comprehensive end-to-end testing methodology was implemented for our SRS QA program. The Steev phantom enabled realistic evaluation of the entire treatment process. Overall spatial and dosimetric accuracy of the delivery were 1 mm and 3 % respectively.

60 APPLIED LIFE SCIENCES↗

Antimicrobial properties of nanostructured surfaces – demonstrating the need for a standard testing methodology

Bioinspired nanostructured materials that exhibit antimicrobial properties are being synthesized and tested at increasing rates for use in healthcare, manufacturing processes, and diagnostics. Although progress has been made in improving and understanding their bactericidal activity, arguably, the biggest problem currently in the field is the lack of a standard testing methodology that allows for optimal characterization and better comparison of emerging nanostructures. In this work, we examine two forms of nanostructured silicon that vary in their ability to kill certain bacterial species due to different physical mechanisms and derive guidelines for the comparative testing. We perform a comprehensive evaluation of methodologies used extensively in the field (e.g., colony counting and live dead analysis) and the novel application of high-throughput flow cytometry. The data reveal how the techniques are complementary but not always directly equivalent or correlative. Therefore, comparison of results obtained using different methodologies on different materials can be grossly misleading. We report significant variations in bactericidal efficiencies depending on experimental environments (medium type, etc.) and methodologies employed. In addition, we demonstrate how cytometry is yet another powerful complementary tool that can aid the mechanistic understanding of antimicrobial activities of rough surfaces. Besides standardization for comparison, ultimately, evaluation methods need to consider anticipated applications. Then and only then can the true potential (or limitation) of a novel material be determined for its suitability for advancement in a particular field of use.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Test methodology for validation of multi-frequency models of renewable energy generators using small-signal perturbations

Providing trustworthy and accurate multi-frequency (or harmonic) models for renewable energy generators (REG) is an ongoing challenge for harmonic studies. There have been effective attempts to propose and design a test device to validate the harmonic models, mainly based on shunt current perturbations. However, using additional devices for perturbations is costly for converter-based test sites. This paper provides the test specifications to extend the application of the grid emulators for voltage perturbations and appropriate harmonic model validation. Besides, the effects of the sequence couplings, initial emissions, and power set-points on the test results have been overlooked in the literature. Considering these effects, this paper proposes a generic test methodology to obtain more accurate models in the sequence domain. The experimental verification of the proposed methodology is demonstrated using a 7 MVA grid emulator for testing of a 2 MVA photo-voltaic converter and a 2 MVA Type 3 wind turbine. This way, the test challenges, specifications, and recommendations are presented using the MW-scale experiments on different REGs. Furthermore, the effects of sequence couplings and initial emissions on the calculation results are investigated and compared. The proposed methodology is applicable for harmonic model validation as well as empirical modelling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of hydrogen sensor performance are being developed. Various commercial sensor platforms (e.g., thermal conductivity, catalytic and metal semiconductor) were used to demonstrate the advantages and issues with the flow through methodology.

14 SOLAR ENERGY↗

Survival analysis of colorectal cancer patients with tumor recurrence using global score test methodology

Colorectal cancer is the third and the second most common cancer worldwide in men and women respectively, and the second in Malaysia for both genders. Surgery, chemotherapy and radiotherapy are among the options available for treatment of patients with colorectal cancer. In clinical trials, the main purpose is often to compare efficacy between experimental and control treatments. Treatment comparisons often involve several responses or endpoints, and this situation complicates the analysis. In the case of colorectal cancer, sets of responses concerned with survival times include: times from tumor removal until the first, the second and the third tumor recurrences, and time to death. For a patient, the time to recurrence is correlated to the overall survival. In this study, global score test methodology is used in combining the univariate score statistics for comparing treatments with respect to each survival endpoint into a single statistic. The data of tumor recurrence and overall survival of colorectal cancer patients are taken from a Malaysian hospital. The results are found to be similar to those computed using the established Wei, Lin and Weissfeld method. Key factors such as ethnic, gender, age and stage at diagnose are also reported.

60 APPLIED LIFE SCIENCES↗

Progress Report on Modified Burst Testing and Alternative Test Methodologies

Performance of accident-tolerant fuel candidates must be assessed during the pellet-cladding mechanical interaction (PCMI) phase of a design-basis reactivity-initiated accident (RIA). Therefore, in this report, we describe Fiscal Year (FY) 2019 research activities on the development of separate-effects testing for ATF cladding candidate iron-chromium-aluminum (FeCrAl) tube specimens under loading conditions comparable to the PCMI. The first section of this report provides modified-burst test (MBT) results of unirradiated FeCrAl tubes at various pressurization-rates and an RIA-relevant temperature (275°C). The failure strain of FeCrAl was observed and calculated using a high-speed digital-image correlation (DIC) technique developed recently under the Department of Energy (DOE)’s Advanced Fuel Campaign (AFC). To overcome the complexities of performing MBT in a hot-cell environment on irradiated samples, a “plane-strain tension” (PST) test was proposed as an alternative methodology for PCMI testing. The relevance of the PST test as an alternative to MBT for irradiated specimens was explicated using the data available in the literature. The design of hot-cell compatible PST fixtures and a specific holder for PST hot-cell specimen machining were developed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancing the Benefit of the Chemical Mixture Methodology: A Report on Methodology Testing and Potential Approaches for Improving Performance

Extensive testing shows that the current version of the Chemical Mixture Methodology (CMM) is meeting its intended mission to provide conservative estimates of the health effects from exposure to airborne chemical mixtures. However, the current version of the CMM could benefit from several enhancements that are designed to improve its application of Health Code Numbers (HCNs) and employ weighting factors to reduce over conservatism.

chemical mixture methodology↗

Survey Corrosion Testing Methodologies for Additively Manufactured Materials – PNNL

The Advanced Materials and Manufacturing Technology (AMMT) Program intends to develop cross-cutting technologies in support of a broad range of nuclear reactor technologies, and to maintain U.S. leadership in materials and manufacturing technologies for nuclear energy applications. The overarching vision of the AMMT Program is to accelerate the development, qualification, demonstration, and deployment of advanced materials and manufacturing technologies to enable reliable and economical nuclear energy.

36 MATERIALS SCIENCE↗