Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal blocking filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

In-Band Scattering and Absorption of Infrared Blocking Foam Filters for Millimeter-wave Cameras

Expanded closed-cell polymer foams are widely used as thermal infrared (IR) blocking filters in millimeter-wave cameras, particularly for Cosmic Microwave Background observations. Precise knowledge of their millimeter-wave properties is essential for optimizing sensitivity. We present broadband (150 GHz - 2 THz) transmittance spectroscopy of Styroace-II and several Zotefoam filters, fitting their spectra with a radiative transfer model incorporating dielectric absorption and Rayleigh, Mie, and higher-order scattering. For a typical 5~cm thick filter stack at 280~GHz, Styroace-II exhibits ${\sim}10\%$ scattering with absorption estimated as ${\lesssim}5\%$ by effective-medium theory, while Zotefoam HD30 offers superior performance at ${\sim}3\%$ scattering and absorption likewise bounded to ${{\lesssim}0.3\%}$. Each model component is constrained at the ${\sim}0.1\%$ transmittance level for millimeter wavelengths. We observe batch-to-batch scattering variability of up to 2 percentage points in foams with multiple tested batches. Less commonly used Zotefoam formulations (LD15 and LD24) can further reduce in-band scattering to ${<}1\%$ while maintaining negligible in-band absorption and likely comparable IR blocking due to shared polyethylene absorption features and similar cell sizes. Based on this work, a filter constructed from the best measured LD24 batch has replaced the Styroace-II filter in a Simons Observatory 220/280 GHz Small Aperture Telescope.

Thomas, Alex [Chicago U., Astron. Astrophys. Ctr.;↗

Effect of the Lignin Structure on the Physicochemical Properties of Lignin-Grafted-Poly(ε-caprolactone) and Its Application for Water/Oil Separation

Lignin-grafted poly(ε-caprolactone) copolymers (lignin-g-PCLs) have shown wide application potentials in coatings, biocomposites, and biomedical fields. However, the structural heterogeneity of lignin affecting the structures and properties of lignin-g-PCL has been scarcely investigated. In this study, kraft lignin is fractionated into four precursors, namely, F ins , F1, F2, and F3, with declining molecular weights and increased hydroxyl contents. Lignin-g-PCLs are synthesized via ring-opening polymerization of ε-caprolactone with lignin and characterized by GPC, FTIR, 1 H and 31 P NMR, DSC, TGA, and iGC. The mechanical properties, UV barrier, and enzymatic biodegradability of the lignin-g-PCLs are evaluated. Results show that lignin with a higher molecular weight and aliphatic OH favors the copolymerization, leading to lignin-g-PCLs with longer PCL arms. Moreover, lignin incorporation improves the thermal stability, hydrophobicity, and UV-blocking ability but reduces the lipase hydrolyzability of the copolymers. We also demonstrated that the lignin-g-PCL-coated filter paper could successfully separate chloroform–, petroleum ether–, and hexane–water mixtures with an efficiency up to 99.2%. The separation efficiency remains above 90% even after 15 cycles. The structural differences of copolymers derived from the fractionation showed minimal influence on the separation efficiency. This work provides new insights into lignin-based copolymerization and the versatility of lignin valorization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-destructive, in-situ evaluation of water presence using thermal contrast and cooled detector

Exemplary systems for detecting water include: a light source positioned to transmit thermal radiation through a sample; a lens assembly positioned to: receive the thermal radiation transmitted through the sample; and focus the transmitted thermal radiation onto a filter positioned between the lens assembly and a detector; and a cooling subsystem for cooling the filter and the detector to a temperature below that of the sample. The filter (1) selectively transmits first portions of the thermal radiation received from the lens assembly and characterized by a wavelength at least partially overlapping a predefined water absorption band and/or a predefined water absorption line; and (2) selectively blocks second portions of the thermal radiation received from the lens assembly and characterized by a wavelength outside the predefined water absorption band and/or the predefined water absorption line. Methods for detecting presence of water in a sample are also disclosed.

Bora, Mihail↗

Method for conducting in situ high-temperature digital image correlation with simultaneous synchrotron measurements under thermomechanical conditions

This work presents a novel method of obtaining in situ strain measurements at high temperature by simultaneous digital image correlation (DIC), which provides the total strain on the specimen surface, and synchrotron x-ray diffraction (XRD), which provides lattice strains of crystalline materials. DIC at high temperature requires specialized techniques to overcome the effects of increased blackbody radiation that would otherwise overexpose the images. The technique presented herein is unique in that it can be used with a sample enclosed in an infrared heater, remotely and simultaneously with synchrotron XRD measurements. The heater included a window for camera access, and the light of the heater lamps is used as illumination. High-temperature paint is used to apply a random speckle pattern to the sample to allow the tracking of displacements and the calculation of the DIC strains. An inexpensive blue theatrical gel filter is used to block interfering visible and infrared light at high temperatures. This technique successfully produces properly exposed images at 870 °C and is expected to perform similarly at higher temperatures. The average strains measured by DIC were validated by an analytical calculation of the theoretical strain. Simultaneous DIC and XRD strain measurements of Inconel 718 (IN718) tensile test specimens were performed under thermal and mechanical loads and evaluated. Finally, this approach uses the fact that with DIC, the total strain is measured, including plastic strain, while with XRD, only elastic strain is captured. The observed differences were discussed with respect to the effective deformation mechanisms.

47 OTHER INSTRUMENTATION↗

Sub-1K Cold-Electron Quantum Well Switching at Room Temperature

Quantum states can provide means to systematically manipulate the transport of electrons. Here, in this study, we present electron transport across quasi-bound states of two heterogeneous quantum wells (QWs), where the transport of thermally excited electrons is blocked or enabled depending on the relative positions of the two quasi-bound states, with an abrupt current onset occurring when the two QW states align. The QW switch comprises a source (Cr), QW1 (Cr 2 O 3 ), QW2 (SnO x , x < 2), a tunneling barrier (SiO 2 ), and a drain (Si), where the effective electron mass of QW1 (m* QW1 ) is selected to be larger than QW2 (m* QW2 ). The current-voltage (I-V) measurements of the fabricated devices show abrupt current onsets, with the current transition occurring within 0.25 mV, corresponding to an effective electron temperature of 0.8 K at room temperature. Since transistor power consumption is fundamentally tied to effective electron temperature, this sub-1K cold-electron QW switching holds promise for highly energy-efficient computing.

Fermi−Dirac thermal smearing↗