SEARCH · Search NASA
Results for “thermal compressor”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Hydrodynamic considerations and design concepts for optimal thermal compressors
Not Available
Experimental investigation of a compact thermal compressor for an ammonia-water absorption heat pump
Not Available
Improved heat switch for gas sorption compressor
Thermal conductivities of the charcoal bed and the copper matrix for the gas adsorption compressor were measured by the concentric-cylinder method. The presence of the copper matrix in the charcoal bed enhanced the bed conductance by at least an order of magnitude. Thermal capacities of the adsorbent cell and the heat leaks to two compressor designs were measured by the transient method. The new gas adsorption compressor had a heat switch that could transfer eight times more heat than the previous one. The cycle time for the new prototype compressor is also improved by a factor of eight to within the minute range.
A data driven control strategy for optimal and flexible operation of absorption systems; Stratégie de régulation fondée sur les données pour un fonctionnement optimal et flexible des systèmes à absorption
A novel control strategy for vapor absorption systems with experimental validation is presented. Statistical methods are used to integrate a detailed thermodynamic model and system-specific characteristics into a model based control algorithm. This allows for continuously optimized operation as well as fast response to variations in operating conditions. Autonomous controller performance was tested experimentally for response to changes in heat sink and evaporator temperatures. Continuous turndown with fast response to capacity demand changes, in contrast to suboptimal on/off control, was demonstrated. The thermal compressor concept was employed to develop the variable speed thermal compressor module, with aspects specific to absorption heat pumps, also facilitating cross-applicability of vapor compression system control strategies. Our results of this study enable further development and optimization of absorption systems for a wide range of applications.
Grid Adaptive Harmonic Adsorption Recuperative Power and Cooling System
We introduce a new non-condensing thermodynamic cycle that uses the chemical adsorption affinity of new nanostructured porous materials in a thermal compressor that eliminates the evaporator, condenser, and high pressure pump in the standard ORC to produce 40% more power from the same temperature heat source and can switch modes to cooling if required. This CCHP system is driven by low-grade heat (T<150 oC) and can operate in ambient temperatures over 40 oC. There is great interest in extracting economic benefit from the vast quantity of low and mid-grade heat rejected to the environment from primary energy conversion sources. In the U.S., this amounts to approximately 59 quads of wasted thermal energy. Geothermal resources at temperatures between 100 and 200 °C represent an additional very large (100 GWth) and widely geographically dispersed resource. Solar PV panels convert the majority of the incident solar radiation to heat as well. The principal reason why these thermal resources are not more fully exploited is cost. Low grade heat sources have modest exergy that can be turned into useful work. This means that standard power generation equipment, heat exchangers, expanders, pumps, etc. are significantly larger for the amount of power generated and efficiency of standard thermodynamic cycles such as the Rankine cycle are inherently low, less than 10% typically. The resulting high capital and operating costs relative to the amount of revenue that can be generated from power sales is rarely very economically attractive, especially today with low costs for natural gas. Hence there is a pressing need for new concepts that can dramatically bend the cost curve of power production from low grade heat sources. In this presentation, we describe a new non-condensing thermal compression cycle that offers potential for transformational improvements in cost and efficiency as compared with standard ORC systems. Although the thermal compressor described herein can be used for cooling, the focus here will be power generation.
Thermal pump-compressor for space use Patent
Thermal pump-compressor for converting solar energy
Integrated Heat Switch/Oxide Sorption Compressor
Thermally-driven, nonmechanical compressor uses container filled with compressed praseodymium cerium oxide powder (PrCeOx) to provide high-pressure flow of oxygen gas for driving closed-cycle Joule-Thomson-expansion refrigeration unit. Integrated heat switch/oxide sorption compressor has no moving parts except check valves, which control flow of oxygen gas between compressor and closed-cycle Joule-Thomson refrigeration system. Oxygen expelled from sorbent at high pressure by evacuating heat-switch gap and turning on heater.
Better Gas-Gap Thermal Switches For Sorption Compressors
Gas-gap thermal switches associated with sorption compressors of some heat pumps and cryogenic systems designed for higher performance, according to proposal, by introducing controlled turbulent flows into gas gaps. Utilizes convection in turbulent flow to transfer heat at greater rate. Design takes advantage of flow of working fluid. Working fluid also serve as heat transfer medium in gas gap.
Computer program for analysis of split-Stirling-cycle cryogenic coolers
A computer program for predicting the detailed thermodynamic performance of split-Stirling-cycle refrigerators has been developed. The mathematical model includes the refrigerator cold head, free-displacer/regenerator, gas transfer line, and provision for modeling a mechanical or thermal compressor. To allow for dynamic processes (such as aerodynamic friction and heat transfer) temperature, pressure, and mass flow rate are varied by sub-dividing the refrigerator into an appropriate number of fluid and structural control volumes. Of special importance to modeling of cryogenic coolers is the inclusion of real gas properties, and allowance for variation of thermo-physical properties such as thermal conductivities, specific heats and viscosities, with temperature and/or pressure. The resulting model, therefore, comprehensively simulates the split-cycle cooler both spatially and temporally by reflecting the effects of dynamic processes and real material properties.
Toward Polarization-Switched Molecular Pumps
Pumping of fluids is universally performed by using mechanical or thermal compressors. We demonstrate for the first time a new solid-state molecular pumping mechanism induced by switching the adsorption affinity for a gas through polarization of a chromophore under an applied electric field. Mass spectrometry was used to trace refrigerant gas (difluoromethane) uptake on a chromophore-coated capacitor under applied voltage and subsequent desorption when the voltage and electrode polarization was removed showing an exchange capacity of 0.11 mol of refrigerant per liter of chromophore. Calorimetry confirmed a reversible enthalpy change of 9 Kcal/mol in the polarization-induced sorption-desorption process. Here, the present work establishes the principle and feasibility of non-mechanical molecular pumping, which can be exploited for refrigeration, catalysis, gas separation, among many other potential applications.
Altitude-Wind-Tunnel Investigation of a 4000-Pound-Thrust Axial-Flow Turbojet Engine: Analysis of Turbine Performance - 5
Performance characteristics of the turbine of a 4000-pound-thrust axial-flow turbojet engine was determined in investigations of the complete engine in the NACA Cleveland altitude wind tunnel. Characteristics are presented as functions of the total-pressure ratio across the turbine and of turbine speed and gas flow corrected to sea-level conditions. Three turbine nozzles of different areas were used to determine the area that gave optimum performance. Inasmuch as tail-pipe nozzles of different diameters were investigated in combination with the standard turbine nozzle, the effect of varying discharge conditions on turbine operation could be observed. The investigations covered a range of pressure attitudes from 5000 to 40,000 feet. The engine was investigated over the entire operable range of speeds at each altitude. At pressure altitude of 30,000 feet, the effect on turbine operation of varying the ram pressure ration over a range from 1.10 to 1.77 was evaluated. An altitude effect was apparent when turbine pressure ratio was plotted against corrected turbine speed but it was so slight as to be negligible insofar as the turbine efficiencies were concerned. A maximum turbine efficiency of slightly more than 82 percent was obtained with the configuration using the standard turbine nozzle and the low-flow compressor. This efficiency, which is somewhat lower than the actual turbine efficiency, is uncorrected for accessories drive power, bearing friction, tail-pipe pressure drop, compressor thermal radiation, and introduction of turbine-disk cooling air into the gas stream. Changes in the ram pressure ratio had a negligible effect on the turbine efficiency.
Total Thermal Management of Battery Electric Vehicles (BEVs)
The key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10°C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor) (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.
Thermal Modeling of a Compressor for CO2 Removal in the International Space Station
Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. A thermal model of the AC-TSAC was created in COMSOL and validated by comparing the model outputs to experimental data for the heating phase of the cycle. Subsequently, several design trades and performance sensitivities were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), thermal conductivity of the adsorbent material and bed structural materials, and the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.
Thermal Modeling of a Compressor for CO2 Removal in the International Space Station
Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. A thermal model of the AC-TSAC was created in COMSOL and validated by comparing the model outputs to experimental data for the heating phase of the cycle. Subsequently, several design trades and performance sensitivities were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), thermal conductivity of the adsorbent material and bed structural materials, and the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.
UTEMPRA - Unitary Thermal Energy Management for Propulsion Range Augmentation
Key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10 degrees C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor), (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.
Transient and thermo-economic analysis of MED-MVC desalination system
An exergo-economic model is used to assess the performance of a multi-effect desalination plant integrated to a mechanical vapor compressor unit (MED-MVC) with a water production capacity of 1500 $m^3$/day. The results show that the second law efficiency ($\eta_{II}$) 2.8%. The MVC and evaporator units are responsible for about 39 and 52% of the total exergy destruction, respectively. The total water price (TWP) is 1.70 $\$/m^3$ when calculated using a simple conventional economic model and 1.63 $\$/m^3$ when calculated using an exergy-based cost model. Increasing the number of effects from 1 to 6 results in a 39% reduction in the specific power consumption (SPC), a 70% increase in $\eta_{II}$ and a 24% decrease in TWP. A dynamic model is developed to investigate the effect of fluctuations of compressor work ($\dot{W}_c$) and inlet seawater temperature ($T_{sw}$) on the plant behavior and performance. The dynamic model results show that the disturbance in $\dot{W}$ has a significant effect on the plant transient behavior and may cause the plant to cease operation while a disturbance in $T_{sw}$ has only a moderate impact. Increasing $T_{sw}$ above a certain value of the steady-state condition without proper control on the plant response could lead to evaporator dry out. In term of performance, a reduction in $\dot{W}_c$ causes a decrease in the plant production capacity and SPC, while it increases the plant performance ratio (PR). On the other hand, a reduction in the inlet $T_{sw}$ causes a reduction in the plant production capacity and PR and an increase in SPC for the same compressor work. Furthermore, a comparison between a MED-MVC system and a MED integrated to a thermal vapor compressor system (MED-TVC) reveals that the latter system is rather sensitive to the reduction in $T_{sw}$ due to the presence of the condenser unit in the MED-TVC. The response of the MED-MVC system is slower than the MED-TVC which is due to the high thermal capacity of the preheaters for the feed in the MED-MVC.
Heat transfer implications in the first MEMS fabricated thermal transiration-driven vacuum pump for gases
The success of NASA's future space missions and the development of portable, commercial instrument packages will depend greatly on miniaturized components enabled by the use of microelectromechanical systems (MEMS).