Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal dynamic model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal dynamic modeling study

Some thermal dynamic requirements associated with the space shuttle vehicle are reviewed. Pertinent scaling laws are discussed and recommendations are offered regarding the need for conducting reduced-scale dynamic tests of major components at elevated temperatures. Items considered are the development and interpretation of thermal dynamic structural scaling laws, the identification of major related problem areas and a presentation of viable model fabrication, instrumentation, and test procedures.

Ojalvo, I. U.↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building thermal dynamics modeling with deep transfer learning using a large residential smart thermostat dataset

Understanding thermal dynamics and obtaining the computational model of residential buildings enable its scaled application in energy retrofits, control optimization and decarbonization. In this paper, we present a deep learning approach to model building thermal dynamics with smart thermostat data collected from residential buildings, with the goal to investigate model generalizability. In the first stage, we developed and compared different Deep Learning architectures including Convolutional Neural Networks (CNN), Long Short-Term Memory (LSTM) models and CNN-LSTM to predict indoor air temperature in a multi-step time horizon. In the second stage, we implemented a Transfer Learning (TL) process, which aims to improve the prediction performance on a new set of buildings (targets), exploiting the knowledge of related or similar buildings (sources). Different TL strategies and source model identification methods were investigated. The study showed that the CNN-LSTM performed the best among the architectures compared, with an average Mean Absolute Error (MAE) of 0.26 °C for one-hour-ahead (twelve 5-min future steps) predictions. Furthermore, the results showed that freezing the LSTM layer and fine-tuning the other layers of the CNN-LSTM achieved the best performance among four TL strategies, which further improved the performance with respect to a machine learning approach by 10%, and proving the effectiveness and generalizability of the proposed approach. A comparison of three different source model identification methods showed that randomly selecting source models constrained by similar building characteristics can provide good TL performance while retaining simplicity comparing with other quantitative source identification methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification of aggregate building thermal dynamic model and unmeasured internal heat load from data

This paper is on the problem of simultaneously identifying the parameters of an aggregate thermal dynamic model of a multi-zone building and unknown disturbances from input-output data. An aggregate model is a single-zone equivalent of a multi-zone building, and is useful for many purposes, including model based control of large heating, ventilation and air conditioning (HVAC) equipment that delivers thermal energy to the entire building. A key challenge in identification is the presence of unknown disturbance since it is not measurable but non-negligible.We first present a principled method to aggregate a multizone building model into a single zone model. We then provide a method to identify thermal parameters and the unknown disturbance for this aggregate (single-zone) model. Finally, we test our proposed identification algorithm to data generated from a virtual building. A key insight provided by the aggregation method allows us to recognize under what conditions the estimation of the disturbance signal will be necessarily poor and uncertain.

Guo, Zhong↗

Thermal-dynamic modeling study

Study provides basic information for designing models and conducting thermal-dynamic structural tests. Factors considered are development and interpretation of thermal-dynamic structural scaling laws; identification of major problem areas; and presentation of model fabrication, instrumentation, and test procedures.

Ojalvo, I. U.↗

Aggregation and data driven identification of building thermal dynamic model and unmeasured disturbance

An aggregate model is a single-zone equivalent of a multi-zone building, and is useful for many purposes, including model based control of large heating, ventilation and air conditioning (HVAC) equipment. This paper deals with the problem of simultaneously identifying an aggregate thermal dynamic model and unknown disturbances from input–output data of multi-zone buildings. The unknown disturbance is a key challenge since it is not measurable but non-negligible. In this paper, we first present a principled method to aggregate a multi-zone building model into a single zone model, and show the aggregation is not as trivial as it has been assumed in the prior art. We then provide a method to identify the parameters of the model and the unknown disturbance for this aggregate (single-zone) model. Finally, we test our proposed identification algorithm to data collected from a multi-zone building testbed in Oak Ridge National Laboratory. A key insight provided by the aggregation method allows us to recognize under what conditions the estimation of the disturbance signal will be necessarily poor and uncertain, even in the case of a specially designed test in which the disturbances affecting each zone are known (as the case of our experimental testbed). This insight is used to provide a heuristic that can be used to assess when the identification results are likely to have high or low accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Dimensional Dynamical Models of Thermal Convection

A low-dimensional dynamic model for transitional buoyancy-driven flow in a differentially heated tall enclosure is presented. The full governing partial differential equations with the associated boundary conditions are solved by a spectral element method for a cavity of aspect ratio A=20. Proper orthogonal decomposition is applied to the oscillatory solution at Prandtl number Pr=P tau (omega) = 0.71 and Grashof number G tau (omega) = 3.2 x 10 (exp 4) to construct empirical eigenfunctions. Using the four most energetic empirical eigenfunctions for the velocity and temperature as basis functions and applying Galerkin's method, a reduced model consisting of eight nonlinear ordinary differential equations is obtained. Close to the 'design' conditions (P tau(omega) G tau(omega)), the low-order model (LOM) predictions are in excellent agreement with the predictions of the full model. In particular, the critical Grashof number at the onset of the first temporal flow instability (Hopf bifurcation) was well as the frequency and amplitude of oscillations at supercritical conditions are in excellent agreement with the predictions of the full model. Far from the 'design' conditions, the LOM predicts the existence of multiple stable steady solutions at large values of G tau, and a unique stable steady solution at small values of G tau, and exhibits hysteretic behavior that is qualitatively similar to that observed in direct numerical simulations based on the full model.

Liakopoulos, Anthony↗

Online Learning for Commercial Buildings

There has been an increased interest in designing optimization based techniques for the control of building heating, ventilation, and air-conditioning (HVAC) systems for either improving the energy efficiency of buildings or providing ancillary services to the electric grid. The performance of such prediction-based control techniques heavily rely on the model of a building’s thermal dynamics. However, the development of high fidelity building thermal dynamic models is challenging given the presence of large uncertainties that affect thermal loads in buildings such as building envelope performance, thermal mass, internal heat gains as well as occupants' behavior. In this paper, we propose a method to identify both a resistive-capacitive parametric model, and non -parametric load uncertainties using measured input-output data. The parametric model is obtained using semi-parametric regression, whereas the non-parametric part is based on Random Forest, where regression trees are used to derive the dependency of non-parametric terms on both building operation parameters and ambient temperature. The effectiveness of the method is evaluated using experimental data collected from an office building at the Pacific Northwest National Laboratory (PNNL) campus. The proposed methodology was observed to provide improved accuracy over appropriate baseline strategies, when predicting indoor air temperatures.

Dong, Jin↗

A dynamic thermal algal growth model for pilot-scale open-channel raceways

Here this study describes the makeup of and results from a simulation consisting of a lumped thermal model integrated with a dynamic algae growth model to simulate the microalgae productivity of an open-channel raceway cultivation system. The thermal model considers the dynamic effects of weather, light absorption, convective heat transfer, radiation heat transfer, conductive heat transfer, thermal capacitance, and water control strategies. The dynamic algae growth model solves a set of ordinary differential equations consisting of growth functions dependent on incident radiation, temperature, nutrient availability, basal metabolism, and losses due to dark- and photo-respiration. Relative errors in the predicted ash-free dry weight of Nannochloropsis oceanica are 12.5%, -6.1%, and 4.4% for three separate replicates of cultivation cycles (~4.2 m 2 ) performed at AzCATI during the ATP 3 Unified Field Studies in Fall, Spring, and Summer. This research demonstrates that thermal modeling is an essential contributor to the validation of microalgae growth models.

09 BIOMASS FUELS↗

The development of an advanced generic solar dynamic heat receiver thermal model

An advanced generic solar dynamic heat receiver thermal model under development which can analyze both orbital transient and orbital average conditions is discussed. This model can be used to study advanced receiver concepts, evaluate receiver concepts under development, analyze receiver thermal characteristics under various operational conditions, and evaluate solar dynamic system thermal performances in various orbit conditions. The model and the basic considerations that led to its creation are described, and results based on a set of baseline orbit, configuration, and operational conditions are presented to demonstrate the working of the receiver model.

Wu, Y. C.↗

Nuclear Thermal Propulsion Dynamic Modeling with Modelica

Oak Ridge National Laboratory (ORNL) is participating in the nuclear thermal propulsion (NTP) research and development effort supported by the National Aeronautics and Space Administration (NASA). This effort involves collaboration between multiple research groups, representing various government agencies and industry partners. ORNL has developed a Modelica-based modeling package for dynamic system modeling of nuclear reactors called the Transient Simulation Framework of Reconfigurable Models (TRANSFORM). While this software has been successfully demonstrated in simulations of traditional pressurized-water reactors, boiling-water reactors, liquid-metal reactors and molten-salt reactors, it has also been adapted for non-traditional use in modeling hybrid energy systems, and tritium transport. This versatility is being applied to the current NTP project, where specific modules within TRANSFORM are being developed for and applied to transient modeling of the NASA NTP design. This paper presents the current state of the ORNL-NTP model, the utility of TRANSFORM methodologies in NTP transient simulations, the ability to develop NTP-specific modules, and future work for the model.

Rader, Jordan↗

Delivery of Dynamic Thermal Energy Storage Models and Advanced Reactor Concept Models to the HYBRID Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), sodium fast reactor (SFR), compressed air energy storage (CAES), liquid air energy storage (LAES) and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed. Also detailed in this report are future development goals for the HYBRID repository including adding suites of steady-state models, economic costing information, and reduced-order models. By adding these models in addition to the physical transient models currently existing within HYBRID, HYBRID will be a fully integrable tool for FORCE users.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Physics-constrained Deep Recurrent Neural Models of Building Thermal Dynamics

We develop physics-constrained and control-oriented predictive deep learning models for the thermal dynamics of a real-world commercial office building. The proposed method is based on the systematic encoding of physics-based prior knowledge into a structured recurrent neural architecture. Specifically, our model mimics the structure of the building thermal dynamics model and leverages penalty methods to model inequality constraints. Additionally, we use constrained matrix parameterization based on the Perron-Frobenius theorem to bound the eigenvalues of the learned network weights. We interpret the stable eigenvalues as dissipativeness of the learned building thermal model. We demonstrate the effectiveness of the proposed approach on a dataset obtained from an office building with $20$ thermal zones.

Building Energy, structured neural networks↗

Dynamic Modeling of Latent Heat Thermal Battery

A dynamic thermodynamic model is constructed in Modelica for the thermal battery portion of a heat pipe integrated thermal battery and is demonstrated using a shakedown test. The model is also leveraged to inform aspects of an experiment configuration. The theory section discusses modeling assumptions of the thermal battery system, establishes how melting and fusing is calculated, and how internal convection is modeled within the thermal battery. The shakedown test uses three charge-standby-discharge-standby cycles in which the charging cycles are 10 hours in length and the discharge cycles are 8 hours. System behavior including heat loss, temperature distributions and divergences, and internal convection behavior are presented. The model is then leveraged to show how experiment design can be informed through testing the model for insulation thickness impact on heat loss, round trip efficiency calculation, and heat tracing control.

25 ENERGY STORAGE↗

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗

Integrated Computational Fluid Dynamics and Thermal Desktop Thermal Modeling for Assessment of the EMU in Support of ISS EVA 80

Following the reports of water accumulation in the Extravehicular Mobility Unit (EMU) helmet during the ISS US EVA-80, various efforts for mitigation and further understanding of this phenomenon have been undertaken with the goal of prevention and to ensure crew safety in future EVAs. In support of this goal, a combination of Thermal Desktop thermal modeling and Computational Fluid Dynamics (CFD) has been performed in order to characterize the performance of the EMU components, specifically those within the ventilation/cooling water loops. This modeling effort evaluates the dry/wet gas pressure drop and flow distribution through gas and liquid flow paths using CFD, as well as a two-phase flow assessment of condensation production and water separation/removal performance using an integrated Thermal Desktop model of important EMU ventilation loop components. The models assess this overall thermal-fluid performance in comparison with previous existing models, design points, and historical EVA data using their inputs.

Blain Ryan Lancaster↗