Nuclear microreactors and thermal integration with hydrogen generation processes
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
The Integrated Thermal Energy Storage and Brayton cycle Equipment Demonstration (Integrated TESTBED) project seeks to retire commercial-scale risks associated with the design, integration,and operation of a supercritical carbon dioxide (sCO2) power cycle and concentrating solar power (CSP) thermal energy storage (TES) system. This requires an understanding of commercial-scale collector system transient impacts on the TES system, the dynamics of heat exchange from theTES to the power cycle, and the control and operation of the power cycle to accommodate various dispatch strategies. In order to retire these risks, Heliogen has proposed to construct a 5 MWe CSP demonstration facility based on directly heated particle and sCO2 technology. The receivers, primary heat exchanger, and power cycle will be deployed at a full commercial scale based on Heliogen’s modular plant architecture to ensure actual system integration risks are validated during design, construction, and operation. This work summarizes the design basis for the Integrated TESTBED project demonstration facility including a design target for capacity factor to support test operations, hours of storage, particle silo arrangement, centrifugal article receivers, a diffusion bonded particle-sCO2 heat exchanger, and a 5 MWe (net) integrally geared sCO2 recompression Brayton cycle.
The energy optimization modeling work described here was performed to determine efficiency improvements that could be achieved for existing coal-fired power plants to retrofit a partial CO 2 capture from the post-combustion flue gas for carbon sequestration through thermal integration. The work presented includes optimization of the mono-ethanol amine (MEA)-based post-combustion CO 2 capture to reduce energy requirements that could be achieved at existing power plants by thermal integration of the steam turbine cycle, boiler, CO 2 compression train and post-combustion CO 2 capture process to offset efficiency and capacity losses that would be incurred by retrofit or implementation of post-combustion CO 2 capture. Furthermore, partial CO 2 capture, involving treatment of less than 100% of the flue gas leaving the plant and modular design of the CO 2 scrubbing system, was also investigated. Thermal integration of the steam turbine cycle with boiler and CO 2 compression train improved cycle and plant performance and offset, in part, the negative effects of post-combustion CO 2 capture. The best-analyzed integration options improved gross power output by 5% and net unit efficiency by 1.57%, relative to the conventional MEA process. Operating with 40% CO 2 capture increased gross power output by 11.6–14% (depending on the MEA thermal integration option), relative to the conventional MEA integration and 90% CO 2 capture. The improvement in net unit performance is larger compared to the improvement in turbine cycle performance because of the CO 2 compression work, which is also reduced by partial CO 2 capture.
Heat pump integrated thermal energy storage is analyzed for demand response in grid-interactive buildings. We have reviewed various configurations presented in the literature, in both active and passive storage, and analyzed the reported demand impact, energy savings, and cost savings.
The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.
A heat pipe integrated thermal battery system has been constructed to investigate a high-temperature latent heat thermal energy storage technology that takes advantage of near isothermal operation of latent heat storage and heat pipes to potentially enable high-energy isothermal heat storage. A dynamic model constructed in Modelica has been validated, showing errors between 2.5 °C–39.7 °C across 10-h to 47-h simulations against experiment results, showing good prediction capability of experiment output, especially against phase change time. Model calibrations showing vessel heat-up capability of 3 kW and heat pipes combining to provide 600 W each during experiment operation validate experiment circumstances including reduced material loading and reduced power capability. The experiment configuration uses an Al-Mg-Zn eutectic metal as the storage material, heated via heat tape wrapped around the vessel and guide tubes to bring the system to operation range (>400 °C) and to simulate charging heat exchange, respectively, with heat rejection occurring through the surfaces of the material and facilitated via guide tubes with less insulation wrapping. The model is available in the open-source repository HYBRID on Github.
A thermal connection between the Microreactor AGile Non-nuclear Experimental Testbed (MAGNET) and the thermal energy distribution system (TEDS) has been a key part of the Dynamic Energy Transport and Integration Laboratory (DETAIL) plan since the development of the Integrated Energy Systems Roadmap in 2020. This connection provides an expanding demonstration capability for integrated system operations. The thermal connection between MAGNET and TEDS required the selection of a heat exchanger and valves to isolate flow. Research staff within the NEET Crosscutting Technology Development program selected equipment after receiving proposals from multiple vendors. A helical coil heat exchanger from Graham Corporation was selected for its small volume relative to its heat transfer surface area to fit in the limited space available. Triple offset butterfly valves with pneumatic actuators from Flowserve were selected to isolate and/or control flow of the hot gas through the heat exchanger. Staff from Idaho National Laboratory’s (INL) Facilities and Site Services Engineering department designed the piping and structural support. A mechanical construction firm was contracted to install the system. This report documents the design and construction of this thermal connection.
Final report for Plastic Additive, Sorbent-Coated, Thermally Integrated Contactor for CO2 Capture (PLASTIC4CO2) DE-FE-0032132. The goal of the work was to investigate at a technology readiness level of 3 (TRL 3), the proof of concept of an additively printed plastic 2-channel heat exchanger/sorbent contactor system to achieve a 15% lower levelized cost of electricity (LCOE) than a baseline liquid phase amine adsorber system for 90% and 95% capture of CO 2 from both a 7F02 2x1CC and 7HA02 2x1CC natural gas turbines.
The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.
Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.
Natural-gas-fueled solid oxide fuel cell (SOFC) systems have the potential for high-efficiency conversion of carbon to power due to the underlying electrochemical conversion process while readily facilitating carbon capture through the separation of the fuel and oxidant sources. Compressed air energy storage (CAES) technology can potentially store significant quantities of energy for later use with a high round-trip efficiency and lower cost when compared with state-of-the-art battery technology. The base load generation capability of SOFC can be coupled with CAES technology to provide a potentially flexible, low-carbon solution to meet the fluctuating electricity demands imposed by the increasing share of intermittent variable renewable energy (VRE) production. SOFC and CAES can be hybridized through thermal integration to maximize power output during periods of high electrical demand and then store power when either demand is low or renewable generation reduces power prices. The techno-economics of a low-carbon hybrid SOFC and CAES system was developed and investigated in the present study. The proposed hybrid system was found to be cost-competitive with other power-generating base-load facilities when power availability was considered. The hybrid system shows increased resilience to changes in a high VRE grid market scenario.
In this project, integral benchmarks that aim to examine thermal neutron scattering data for graphite (ideal and nuclear), light water, and molten salt FLiBe will be analyzed. In particular, the project aims to: 1) Develop the slowing-down-time experiment that was performed at the OREAL facility of ORNL as a graphite benchmarks; 2) Identify and examine a slowing-down-time experiment in light water as a potential benchmark; 3) Reexamine the molten salt MSRE-MSR-EXP-001 benchmark to explicitly capture the impact of TSL variations.
As inductive wireless power transfer reaches higher power levels; thermal management becomes essential. To address these concerns, past works have demonstrated the benefit of encapsulating coil assemblies with thermally conductive materials and integrating backside liquid cooling into coil assemblies. This work adds to these developments by considering the thermal analysis and construction of a liquid-cooled high power polyphase wireless power transfer ground assembly intended for long duration operation at high power levels, aiming towards hundreds of kW or even 1 MW.
Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.
Microalgal composition varies with cultivation strategy, and low-cost approaches often produce high-protein biomass. This presents challenges for biorefineries designed around static, lipid-rich feedstocks. In particular, hydrolysates from high-protein algae are nitrogen-rich and sugar-poor, limiting microbial conversion and reducing product yields. This study develops a sequential thermal conditioning and biological upgrading strategy to integrate high-protein hydrolysate processing within conventional lipid extraction and upgrading designs. Oxidative deconstruction was used to break down proteins into ammonium and short-chain carboxylates. Ammonium was subsequently removed to yield a nitrogen-depleted, carboxylate-rich medium suitable for microbial lipid production. Bioconversion trials with Cutaneotrichosporon oleaginosum showed lipid accumulation only from hydrolysates treated with both oxidative deconstruction and nitrogen removal, reaching 1.2 g/L lipids at 30 % intracellular content. This integrated approach enables protein-to-lipid conversion and improves flexibility to process variable algal feedstocks, advancing fuel-oriented microalgal biorefineries.
The DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program supports a full range of computational thermal fluids analysis capabilities and code developments for a broad class of light-water and advanced reactor concepts. The research and development approach under thermal fluids technical area synergistically combines three length and time scales in a hierarchal multi-scale approach. To demonstrate the feasibility and capabilities of a multi-scale thermal fluids capability using these codes, a key joint effort has been pursued to develop an integrated system-and engineering-scale thermal fluids analysis capability with the MOOSE-based codes, through integration of SAM and Pronghorn, both based on the MOOSE framework. This report summarizes the progress in developing an integrated system- and engineering-scale thermal fluids analysis capability based on SAM and Pronghorn for molten salt reactors (MSRs), which gained significant interest in recently years. Two coupling approaches were studied, i.e. separate domain or domain-segregated coupling approach and the domain-overlapping approach. A series of coupled multi-physics models have been developed for a common reference molten salt fast reactor (MSFR) concept, ranging from standalone SAM system model to integrated SAM-Pronghorn-Griffin models. Both the steady state and the transient simulations are performed to the state-of-the-art simulation capabilities of NEAMS software suite in MSFR system applications. This report also covers further development and testing of the gas transport model in SAM for MSR modeling support. The presence of noncondensable gas in MSR systems would have strong impacts on fission gas removal and transport of noble metals throughout the system. Fission products removed through the off-gas system can also impact reactivity and can act as an additional point of heat removal. To ensure that the gas transport model is adequately tested, the supported modeling capabilities and features of SAM were identified, and a suite of tests were developed to test the model for each identified feature. Validation and UQ testing were also performed for the model and demonstrated that the buoyancy term, which was originally developed using non-salt/helium gas experimental data, can capture the experimental gas bubble velocity and diameter to within experimental and code uncertainty. An existing MSRE model was also modified in this work to include the gas transport model and to demonstrate the gas model behavior for realistic conditions of interest.
This final report describes novel capabilities developed as part of DISPATCHES, Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems, for designing hybrid energy systems (HES) a.k.a. integrated energy systems (IES) in the context of a larger electricity market. Capabilities are demonstrated on a case study with fossil-based power coupled to a molten salt thermal energy storage system.
This project endeavors to design and demonstrate an integrated CSP system that meets the Department of Energy’s 6¢/kW-hr LCOE goal [1]. This design is based on the 10 MWe Supercritical Transformational Electric Power (STEP) engine specifications, but adaptable to any sCO 2 power module up to 10 MW e . The enabling technology to be tested is a new class of metal hydride based thermal energy storage materials which can store thermal energy in the hydrogen bonds between the metal hydride and hydrogen. This thermochemical energy storage solution provides a much greater energy density than sensible and latent energy storage enabling an integrated system design that closely linked the metal hydride to the power block. This allows the entire system to be mounted up tower to provide cost reductions. A novel metal hydride, capable of operating above 760 °C, was developed during the course of this project and thoroughly tested at a lab scale. The material’s hydrogen capacity, reaction enthalpy, thermal conductivity, and cyclic stability were measured. A demonstration test article was built that can store 2kWh of thermal energy and was coupled to Brayton Energy’s CO 2 loop where the performance of the metal hydride under commercial conditions was measured. An integrated model was created that uses the inputs from all the different sub-models in order to return an overall system LCOE using SAM. This project greatly advanced metal hydride based thermochemical energy storage technology and demonstrated its use. Previously there were no metal hydrides which were capable of operating at the proposed temperature limits (760°C), there is now a high temperature metal hydride with documented performance/stability and a path for low-cost production. Additionally, the metal hydride was tested at a scale >650x larger than what had previously been done in the lab. While not at commercial scale, it was an excellent demonstration of the technology and provided knowledge that can be leveraged for other applications.