Search NASASearch

SEARCH · Search NASA

Results for “thermal loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal loading effects on chalk hydromechanical behavior for nuclear waste disposal

Safe disposal of heat-generating nuclear waste depends on host rock stability under thermal, hydrological, and mechanical stresses. This study investigates the effect of thermal loading on mechanical behavior of the shallowly buried Ghareb formation chalk through triaxial and hydrostatic constant strain rate and creep tests at temperatures up to 100 ˚C and effective pressures up to 20.7 MPa. Experimental results show that thermal loading reduces the elastic moduli of chalk by 50–75%, and a transition occurs above 60 ˚C where creep rates increase rapidly. Water saturation nearly doubles the thermally induced strain compared to dry conditions and strongly decreases material rigidity. Thermal loading also leads to significant pore pressure increases under undrained conditions and leads to reductions in the apparent permeability during drained conditions. Laboratory experimental data were used to parameterize and develop a preliminary constitutive model for predicting future deformation during repository operations in the Ghareb. The strongly coupled effects – mechanical weakening, fluid pressure fluctuations, and permeability modification – demonstrate that elevated repository temperatures will have a pronounced effect on the near field Ghareb behavior during waste disposal operations. The findings indicate that the coupled interactions must be considered in predictive models and repository design to ensure long-term nuclear waste isolation and safety.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY

Acceptance criteria for in situ surveillance of MSR materials based on thermally-loaded mechanical test articles

This report describes practices and acceptance test procedures for designing, running, and maintaining a material surveillance program in a future operating molten salt reactor. The programs described here rely on test data from passively actuated mechanical test articles inserted into critical regions of the reactor and periodically removed for out-of-reactor testing. The report defines definite acceptance procedures, based on the results of these tests, to determine whether a component can continue to operate accounting for the accumulation of environmentally-assisted mechanical damage in the component materials to date, and extrapolated out through the next inspection period. Additionally, the report describes work on a software tool implementing many of the surveillance methods and procedures described here and progress on simplified methods for inferring damage accumulation in the test articles, based on out-of-reactor thermal cycling, that do not rely on sophisticated numerical analysis.

36 MATERIALS SCIENCE

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

FENIX: Towards a Fully Integrated Multiphysics Framework for Plasma Facing Component Modeling

Computational tools have a crucial role to play in accelerating the deployment of fusion as a clean, reliable, abundant, and sustainable energy source. Multiphysics, high-fidelity simulation capabilities can help model, study, and predict intricate interactions between materials performance, plasma exposure, neutron irradiation, and engineering processes. As such, they can assist in the resolution of scientific and engineering challenges underpinning design, construction, and commission of fusion power plants. To address these needs, ongoing efforts are leveraging the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework and delivering new computational tools for the fusion community. These tools inherit crucial attributes from MOOSE. They are open-source, modular, integrated with nuclear industry-standard software quality assurance processes, and enable multiphysics, multi-fidelity, fully integrated, zero- to three-dimensional, and massively parallel simulations. After a short overview of these capabilities, we will present the development of Fusion ENergy Integrated multiphys-X (FENIX), a MOOSE-based application designed to enable plasma facing component design and performance evaluation. Throughout their lifetime, plasma facing components are exposed to extreme thermal loads, repeated thermal shocks, and irradiation by plasma ions, neutral particles, and high-energy neutrons. Consequently, designing a plasma facing component with acceptable lifetime degradation is extremely challenging. FENIX aims to model the multiphysics environment in which plasma facing components evolve to accelerate their design studies. To that end, FENIX couples existing MOOSE capabilities such as heat transfer, thermomechanics, and thermal hydraulics, with tritium transport via the MOOSE-based Tritium Migration Analysis Program, Version 8 (TMAP8), with neutronics via the MOOSE-based high-fidelity neutron-photon transport and fluid dynamics code Cardinal, and finally with Particle-in-Cell plasma simulation capabilities being developed in this project. In this study, we present the current FENIX capabilities and preliminary results of its application to model the Tritium Plasma Experiment set up at Idaho National Laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Demand response of loads having thermal reserves

Systems and methods are described herein that improve grid performance by smoothing demand using thermal reserves. The smoothed demand can reduce peak loads as well as the ramp rate of demand that will otherwise require the use of inefficient, expensive generation sources. These improvements are tied to the selective switching on or off electrical loads that are coupled to thermal reserves, effectively using the thermal reserves as an energy storage mechanism. Historical data of past usage can be used to create load model and ensure that effects on customer comfort are minimized while still accomplishing the beneficial effects for the overall grid, which enables grid owners to both reduce their operational cost by avoiding expensive generation and improve system reliability by achieving more predictable power demand.

Ren, Wei

Cryogenic thermal modeling of microwave high density signaling

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming the cooling power at each thermal stage. In this paper, we investigate the thermal load of SC-086/50-SCN-CN semi-rigid coaxial cable, which is commonly used for the control and readout lines of a superconducting quantum computer, as we increase the number of lines to a quantum processor. We investigate the makeup of the coaxial cables, verify the materials and dimensions, and experimentally measure the total thermal conductivity of a single cable as a function of the temperature from cryogenic to room temperature values. We also measure the cryogenic DC electrical resistance of the inner conductor as a function of temperature, allowing for the calculation of active thermal loads due to Ohmic heating. Fitting this data produces a numerical thermal conductivity function used to calculate the static heat loads due to thermal transfer within the wires resulting from a temperature gradient. The resistivity data is used to calculate active heat loads, and we use these fits in a cryogenic model of a superconducting quantum processor in a typical Bluefors XLD1000-SL dilution refrigerator, investigating how the thermal load increases with processor sizes ranging from 100 to 225 qubits. We conclude that the theoretical upper limit of the described architecture is approximately 200 qubits. However, including an engineering margin in the cooling power and the available space for microwave readout circuitry at the mixing chamber, the practical limit is approximately 140 qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID

Role of dislocations on martensitic transformation temperatures and microstructure: A molecular dynamics study

Microstructure and defects strongly affect martensitic transformations in metallic alloys. Significant progress has been made in understanding the atomic-level processes that control the role of grain boundaries and precipitates in these solid-to-solid phase transformations. Yet, the role of dislocations and their structures on martensitic transformation temperature and the resulting microstructure remains unclear. Therefore, we used large-scale molecular dynamics simulations to study the forward and reverse transformation of a martensitic material modeled after Ni63Al37 under cyclic thermal loading. The simulations reveal that dislocations in the austenite phase act as one-dimensional seeds for the martensite phase, which is present at temperatures significantly above the martensite start value. We find a reduction in the dislocation density during cyclic thermal loading, which results in the increase in martensite and austenite transition temperatures, in agreement with experiments. Importantly, we extracted a critical martensitic nuclei size for developing stable domains and found that relatively low dislocation densities are needed to grow independent martensitic variants resulting in a multi-domain structure.

Physics

Integrated Neutronics Modeling for Inertial Fusion Energy Systems: Development and Application to LD-FIRST

Lawrence Livermore National Laboratory (LLNL) is proposing a new Laser Driven Fusion Integration Research and Science Test Facility (LD-FIRST) with the goal of providing an experimental testbed for future Inertial Fusion Energy (IFE) systems. However, IFE systems require detailed and accurate multiphysics modeling to quantify material damage, thermal loading, and tritium breeding within complex chamber environments. This article presents the first step in an integrated multiphysics framework that couples meshed CAD-based geometry within Monte Carlo neutronic simulations to enable high-fidelity analysis of IFE chamber concepts, with future coupling to external codes. The neutronics workflow utilizes OpenMC and its third-party capability to use CAD-based geometries through DAGMC and tally on unstructured meshes with Libmesh to evaluate neutron transport behavior, geometric fidelity, and material performance under reactor-relevant conditions. The use of tailored tallies on unstructured meshes in this framework allows direct transfer without interpolating to CFD simulation tools. Two IFE chambers were evaluated, both conceived by LLNL: HYLIFE-II and Laser IFE (LIFE). This work produced high-fidelity conformal surface and volumetric meshes of the HYLIFE-II and LIFE chambers with mapped spatial insight into material damage, thermal loading, and tritium breeding. The HYLIFE-II model was built utilizing available resources and used as a test case to verify that the neutronics framework can handle complex geometries. The LIFE chamber CAD was provided by LLNL and was the main focus of this work. This work analyzes multiple ternary alloy breeding materials for the LIFE chamber, across different 6 Li enrichments to produce data relevant to the LD-FIRST project. This work also investigates the level of model fidelity for the LIFE chamber, and results show that inclusion of detailed first wall and coolant structures increased the predicted tritium breeding ratio (TBR) by ~30%, highlighting the sensitivity of tritium breeding and the need for a high-fidelity simulation framework for IFE chambers. These developments provide a scalable toolset for the design and optimization of next-generation IFE chambers, forming a solid foundation for future coupled multiphysics analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings

Thermal and structural analysis of a new WEST reciprocating probe head with Titanium-Zirconium-Molybdenum armour material

The Tore Supra tokamak was transformed into an X-point divertor fusion device in the frame of the WEST (W-for tungsten-Environment in Steady-state Tokamak) project, launched in support of the ITER tungsten divertor strategy. WEST began operation in 2017. A new reciprocating probe head, equipped with a Titanium-Zirconium-Molybdenum (TZM) heat shield, was recently built and operated on WEST during the C9 Campaign in early 2024. TZM was chosen as armour material for its very good mechanical properties between 700 °C and 1400 °C. This material was already extensively used for probe heads and other plasma facing components on the Alcator C-Mod tokamak. Here, this paper presents the design of the new WEST probe head. It is equipped with tungsten filaments that can be heated to emit electrons and provide a direct measurement of the plasma potential in the scrape-off layer, and it is also equipped with a pair of Langmuir probes. The probe plunges vertically into the plasma, reaches its maximum dive depth, then returns to its protected resting position in about 0.25 s. Thermal loads are calculated using as input the thermal properties of TZM and radial profiles of the heat flux measured in the past by other reciprocating probes, and scaled upwards to the expected heat loads in the WEST scrape-off layer. An analytical estimation of Electromagnetic (EM) loads will also be presented, as well as a thermal and structural analysis of the probe for 15 cycles at maximum plunge depth. The probe is observed by an infrared camera. Comparisons between the heat flux deduced by the Langmuir probe and the infrared radiance of the probe housing during plasma exposure are finally presented.

Diagnostic

Validation of 3D MHD simulations of Ne/D 2 mixed shattered pellet injection in JET

Nonlinear 3D magnetohydrodynamic (MHD) modeling of shattered pellet injection (SPI) in JET tokamak plasmas is performed with the JOREK code. The study focuses on the validation of simulation result with respect to experimental observations, addressing in particular figures of merit for the efficiency of the SPI, as a technique to mitigate thermal loads by injecting radiative impurities like neon during the thermal quench (TQ) phase of disruptions. A set of JET pulses with neon/deuterium atomic mixture ratio in the shattered pellet varying from 10% to 100% provides the experimental data to be compared with. Simulations using different models for the ablation of solid fragments and the radiation of neon impurities are considered. Synthetic diagnostics are employed for a direct quantitative comparison with key JET diagnostic systems providing in particular radiation, electron temperature and density, and magnetic measurements. 3D radiation structures from MHD simulations are analyzed to estimate the toroidal asymmetry of radiation, which is difficult to measure in JET due to the presence of only two toroidally displaced multi-channel bolometry systems. JOREK simulations show that, before the TQ, the bulk of the radiation is concentrated in a toroidal region enclosing the radiating fragments that is missed by both multi-channel bolometers, suggesting a possible underestimation of the total radiation by such diagnostic systems in the pre-TQ phase. On the other hand, JOREK predicts that during the TQ the radiation becomes more toroidally symmetric, with positive implications for the heat load to plasma facing components.

JOREK

FEM Analysis of Hybrid LTS/HTS Cos-Theta Dipole Magnet

After the recent results on Bi-2212 superconductive magnets realized and tested in canted cosine-theta and solenoid designs, respectively, at Lawrence Berkeley National Laboratory (LBNL) and NHMFL, the first Bi-2212 stress-managed cosine-theta insert magnet is in the assembly phase at Fermilab. This insert will be part of the first hybrid cosine-theta magnet made of Nb3Sn outer layers within the US-MDP effort to reach 20 T bore field. This paper reports the analytical analysis of the cosine-theta Nb3Sn/Bi-2212 hybrid magnet. As an introduction, it shows the validation of the finalized HTS coils' design optimized using the ROXIE code. Subsequently, it reports the parameters, logic, and implementation method of the 2D electromagnetic and mechanical FEM analysis of the LTS/HTS hybrid magnet. Results from the ANSYS detailed model made with sub-modeling geometry are compared with the homogeneous model implemented in the past. Moreover, a Python code was implemented to simulate the current degradation due to stresses in the detail-modeled conductor areas. The current degradation is introduced in the simulation dynamics for both conductors as an iteration process during the energization load step only after applying pre-stress and thermal loads. The numerical and graphic results of the 2D cosine-theta LTS/HTS magnet cross-section will be described and analyzed.

D'Agliano, A.

A scoping study of far-SOL main-wall protection limiters for steady-state operation of compact pilot plant tokamaks

We present a novel method for handling steady-state heat fluxes incident on the main wall of pilot plant-scale magnetic fusion devices, based on the utilization of protection limiters in the far scrape-off layer (SOL). This method helps avoid large plasma-wall gaps, without excessively compromising blanket performance. We present an optimization algorithm for determining the appropriate size and scale of these protection limiters given (1) probability distributions of SOL plasma parameters and (2) assumed risk tolerance. As part of this optimization, we have developed an analytic description of parallel heat fluxes across limiter shadows, and an objective cost function (the ‘Far-SOL Marginal Cost’) to quantify the impact that different main-wall thermal management design choices have on reactor capital cost. Applying the model to a midscale fusion pilot plant concept shows that making use of far-SOL protection limiters can reduce capital costs on the order of $500 M, relative to naively increasing the plasma-wall gap. Our analysis demonstrates that the far-SOL power decay length is the highest-leverage plasma assumption for thermal loading of the first wall, and the primary cost driver for main wall thermal management. The relative cost efficiency of protection limiters increases as assumptions on the far-SOL heat flux become more pessimistic. The concepts described in this paper motivate the further development of far-SOL protection limiters as part of larger efforts to design economical core-edge-wall compatible solutions for a fusion pilot plant.

Design under uncertainty