Design and Construction of a 1 MWth sCO2 Thermal Loop Heated by Particle-Based Concentrating Solar Power
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
An improved system for thermal management is provided. The system includes thermally anisotropic composites coupled with a thermal loop to re-direct, reduce, and shape heat flows through a building envelope, having the potential to (1) significantly reduce envelope-generated heating and cooling loads and (2) provide grid services such as decreasing peak loads and shaping energy use. In one embodiment, the thermal management system includes an anisotropic composite that consists of alternating layers of thermal insulation and thermally conductive materials that are immediately adjacent to each other, including polyisocyanurate foam boards and aluminum sheets. The thermal management system also includes a thermal loop along the long edge or the entire the perimeter of the anisotropic composite, the thermal loop having dynamically controlled or floating temperature that is maintained at lower than an outdoor ambient temperature (for cooling). An interior wall structure is inwardly adjacent to the anisotropic composite.
Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.
Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.
We compute the energy loss of heavy fermions moving in a plasma, taking into account the modification of the photon collective modes induced by collisions using a Bhatnagar-Gross–Krook collisional kernel. We include contributions from both hard and soft scatterings of the heavy fermion using a collisionally modified hard-thermal-loop resummed propagator. Using this method, one does not need to introduce a separation scale between hard- and soft-momentum exchanges. To place our calculation in context, we review other theoretical approaches to computing the collisional energy loss of fermions and discuss the systematics and results obtained in each approach compared to using a resummed propagator for both hard and soft momentum exchanges. Our final results indicate that self-consistently including the effect of collisions in the self-energies of the resummed propagator results in an increased energy loss compared to using collisionless hard-thermal-loop propagators. The effect becomes larger as the magnitude of the coupling constant and the velocity of the fermion increase. Published by the American Physical Society 2024
To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.
We compute the anisotropic electrical conductivity tensor of the inner crust of a compact star at nonzero temperature by extending a previous work on the conductivity of the outer crust. The physical scenarios, where such crust is formed, involve protoneutron stars born in supernova explosions, binary neutron star mergers, and accreting neutron stars. The temperature-density range studied covers the transition from a semidegenerate to a highly degenerate electron gas and assumes that the nuclei form a liquid, i.e., the temperature is above the melting temperature of the lattice of nuclei. The electronic transition probabilities include (i) the screening of electron-ion interaction in the hard-thermal-loop approximation for the QED plasma, (ii) the correlations of the ionic component in a one-component plasma, and (iii) finite nuclear size effects. The conductivity tensor is obtained from the Boltzmann kinetic equation in relaxation time approximation accounting for the anisotropy introduced by a magnetic field. The sensitivity of the results towards the matter composition of the inner crust is explored by using several compositions of the inner crust, which were obtained using different nuclear interactions and methods of solving the many-body problem. The standard deviations of relaxation time and components of the conductivity tensor from the average are below ≤25% except close to crust-core transition, where nonspherical nuclear structures are expected. Finally, our results can be used in dissipative magnetohydrodynamics simulations of warm compact stars.
This article surveys our present understanding of the internal structure of the fully developed quark-gluon plasma at temperatures outside the crossover region. The theoretical part of the review covers perturbative and nonperturbative approaches to quark-gluon plasma structure, in particular, hard-thermal loop effective theory, lattice QCD and the functional renormalization group. The phenomenological part of the review scrutinizes the information that has been derived from bulk observables and hard probes in relativistic heavy ion collisions in terms of how it informs our knowledge about the structure of the quark-gluon plasma. The final section lists possible avenues for future progress.
The Closed-Loop Geothermal Working Group and the National Renewable Energy Laboratory (NREL) have studied the performance of disc-shaped and linear thermal enhancements (conductive material introduced around a wellbore) in closed-loop geothermal systems. COMSOL models were developed to investigate the increase in heat production in systems with thermal enhancements compared to those without, across a range of scenarios. This dataset includes two example COMSOL models, a summary of the simulation results, and a link to an accompanying paper. Studied are idealized versions of two thermal enhancement designs: (1) existing or newly created fractures surrounding the wellbore, filled with highly conductive material, and (2) a 'fishbone structure,' where short wellbores are drilled radially outward from the main wellbore and filled with highly conductive material.
We investigated the impact of disc-shaped and linear thermal enhancements on performance of closed-loop geothermal systems using steady-state and transient COMSOL numerical simulations. Thermal enhancements refer to thermally conductive material introduced in the rocks surrounding a wellbore to compensate for the relatively low rock thermal conductivity and increase heat extraction. Materials proposed include composite cements with thermally conductive additives such as metals or graphite to obtain overall cement thermal conductivities of 10 to 100x the rock thermal conductivity. Our simulation approach was modeling a subsegment (e.g., 100 m long) of a wellbore with idealized (e.g., perfect disc-shaped) thermal enhancements, and we report results as relative increase in heat extraction with respect to systems without thermal enhancements. We did not evaluate technical feasibility or cost of installing thermal enhancements. Simulations indicate that for 5-mm thick disc-shaped thermal enhancements with 5-m radius, repeated every 1 m along the wellbore and with thermal conductivity of 100x the rock thermal conductivity, the thermal output increases roughly 20% with respect to a closed-loop system without thermal enhancements. For fishbone structure thermal enhancements, we estimate a roughly 7% increase in thermal output for 5-m long radially outward pipes with half the radius of the main wellbore, repeated every 2.5 m, with thermal conductivity of 100x the rock thermal conductivity.
Surrogate testing platforms provide a means to develop a target aspect of a larger system. Some systems target single aspects while others are more wholistic. ViBRANT (Visual Benign Reactor as Analog for Nuclear Testing) aims to be a wholistic system by representing the primary reactor behaviors through an accessible LED driven reactor core, photodiodes, thermocouples, and high-performance software interfaces being developed to the standards required for actual microreactor deployment such as MARVEL. With the ability to drive control drums enabled with full reactor capability (e.g. speed/angle/torque capability/limits for operation and clutch/spring scram capability), drive ViBRANT’s high fidelity 36 pin hexagon core to represent phenomena via LEDs, and capture the analog response of distributed photodiodes/thermocouples, this paper will show the system’s ability to operate in a closed-loop fashion and do well at matching reactor power/temperature distribution in an accessible reactor surrogate environment.
Explore the source record for details and available documents.
Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.
Abstract Adequate stewardship of geothermal resources requires accurate forecasting of long-term thermal performance. In enhanced geothermal systems and other fracture-dominated reservoirs, predictive models commonly assume constant-aperture fractures, although spatial variations in aperture can greatly affect reservoir permeability, fluid flow distribution, and heat transport. Whereas previous authors have investigated the effects of theoretical random aperture distributions on thermal performance, here we further explore the influence of permeability heterogeneity considering field-constrained aperture distributions from a meso-scale field site in northern New York, USA. Using numerical models of coupled fluid flow and heat transport, we conduct thermal–hydraulic simulations for a hypothetical reservoir consisting of a relatively impervious porous matrix and a single, horizontal fracture. Our results indicate that in highly channelized fields, most well design configurations and operating conditions result in extreme rates of thermal drawdown (e.g., 50% drop in production well temperatures in under 2 years). However, some other scenarios that account for the risks of short-circuiting can potentially enhance heat extraction when mass flow rate is not excessively high, and the direction of geothermal extraction is not aligned with the most permeable features in the reservoir. Through a parametric approach, we illustrate that well separation distance and relative positioning play a major role in the long-term performance of highly channelized fields, and both can be used to help mitigate premature thermal breakthrough.
A refrigerator is an essential appliance for both commercial and residential applications. Thermal (Cold) energy storage can effectively reduce the carbon emission from refrigerators. This preliminary study investigated the demand flexibility of a domestic refrigerator using thermal (cold) energy storage through dynamic modeling and controls. The models include both fresh and frozen compartments, a vapor compression cycle loop, and thermal storage panels. Results show that thermal energy storage can effectively achieve temperature control of the compartments within the 4-hour time window. The load reduction and cost savings (46.3%) were achieved through the TES using TOU rates.
Flexible plant operations and generation (FPOG) offer nuclear power plants (NPPs) the chance to leverage alternative, non-electric revenue streams while ensuring their continued role as reliable, clean, and constant sources of baseload electrical power. The excess thermal energy generated from NPPs during periods of low electricity demand can be channeled as raw materials to numerous industrial processes via a thermal power dispatch (TPD) system. Hydrogen production via high-temperature steam electrolysis (HTSE) is an optimal use case based on technical and economic feasibility. Researchers at Idaho National Laboratory (INL) have conducted previous works that developed and implemented TPD system models within the GSE Solutions Generic Pressurized Water Reactor (GPWR) simulator to support human-in-the-loop (HITL) scenario-based evaluations. The first part of this report documents modifications made to the GPWR TPD model and HMI from the previous iteration in line with a new Sargent and Lundy (S&L) TPD design with an automatic control system. The was done in collaboration with Westinghouse using their three-loop pressurizer water reactor (W3LPWR) simulator which contains an industrial grade automatic control system for the TPD. This was installed in the Human Systems Simulation Laboratory (HSSL) at INL. The second part of the report documents findings from an all-hands-on-deck integration and verification workshop that was conducted in the HSSL over several days. The research team comprised INL human factors and TPD experts, a nuclear engineer from GSE Solutions who implemented the revised TPD model for GPWR, the human-machine interface (HMI) prototyping and human factors team from the University of Idaho, and personnel with operations experience with pressurized water reactors. The workshop provided time and expertise to conduct the final activities to bring the operations, HMI, and simulator into a functional state. The goals of the integration and verification workshop were: 1. to install the revised GPWR TPD model into the HSSL 2. verify the TPD HMI prototype was functional 3. integrate the HTSE Simulink model to GPWR. 3. Issues were identified for resolution, but overall the workshop accomplished its goal to integrated and verify the majority of the intended functional. Future work will resolve the identified issues and use the integrated simulation to support an evaluation and demonstration in the next fiscal year.
Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.
Refrigerated display cases that are used to store and exhibit food products in supermarkets and retail spaces consume a significant portion of the buildings’ total electricity. Importantly, the refrigeration-related energy cost and demand charges are greatly affected by the time-of-use electricity pricing and demand rates, which are at their maximum during peak hours, typically when refrigeration energy consumption is also high. Using energy storage to shift the refrigeration load from peak to off-peak hours can greatly reduce the operational costs in the supermarket. This study demonstrates a phase change material-based thermal energy storage (TES) system, specifically designed in stackable units, that can be integrated with an open vertical refrigerated display case. We perform numerical and experimental characterization that includes finite-difference modeling for the TES, prototype fabrication, and laboratory evaluation, followed by a preliminary system-level analysis to predict the impact of TES on the refrigerated case performance, energy use, and energy cost. The results show that the dedicated latent TES for refrigerated cases can provide a specific energy of 50.4 Wh/kg and a specific power of 15.5 W/kg. The TES can be charged during 12 h of the off-peak period and discharged at various rates during 4 to 6 h of the peak period, thereby shifting the refrigeration load from the peak to the off-peak period. Consequently, annual cost savings up to 19% can be achieved, depending on the thermal load, the summer/winter peak electricity pricing, and the transition temperature of the phase change material used.