Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal model exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Machine-learning modeling of magnetization dynamics in quasi-equilibrium and driven metallic spin systems

Here, we present a perspective on recent progress in machine-learning (ML) force-field approaches for large-scale Landau–Lifshitz–Gilbert (LLG) simulations of metallic spin systems. Building on a generalization of the Behler–Parrinello (BP) architecture originally developed for quantum molecular dynamics, we develop scalable and transferable ML models that faithfully capture the complex, environment-dependent electron-mediated exchange fields characteristic of itinerant magnets. A central ingredient of this framework is the implementation of symmetry-aware magnetic descriptors based on group-theoretical bispectrum formalisms. Leveraging these ML force fields, LLG simulations faithfully reproduce hallmark non-collinear magnetic orders—such as the 120° and tetrahedral states—on the triangular lattice, and successfully capture the complex spin textures emerging in the mixed-phase states of a square-lattice double-exchange model under thermal quench. We further discuss a generalized potential theory that extends the BP formalism to incorporate both conservative and nonconservative electronic torques, thereby enabling ML models to learn nonequilibrium exchange fields from computationally demanding microscopic approaches such as nonequilibrium Green’s-function techniques. This extension yields quantitatively accurate predictions of voltage-driven domain-wall motion and establishes a foundation for quantum-accurate, multiscale modeling of nonequilibrium spin dynamics and spintronic functionalities.

Descriptors↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Development & Experimental Validation of a Generalized Resistance-Capacitance Model for Numerical Simulation of Phase-Change Material Embedded Heat Exchangers

Latent heat thermal energy storage (LHTES) using phase change material (PCM) has attracted increased attention as a viable solution for overcoming the mismatch between energy supply and demand for renewable energy-based systems. PCM-embedded heat exchangers (PCM-HX) have the potential to significantly improve thermal performance due to high storage capacity and low temperature variation during the phase change process. Most models for simulating LHTES heat transfer use Computational Fluid Dynamics (CFD) simulations, which have high computational costs resulting from considering the complex and time-dependent physics relevant to PCM-HXs. In this paper, a Generalized Resistance Capacitance-based Model (GRCM) was developed to predict the thermal performance of arbitrary PCM-HXs in a computationally efficient manner without compromising modeling accuracy. The GRCM is exercised for three case studies: (i) verification for a single-slabbed finned PCM-HX, (ii) verification and validation for a copper foam/paraffin composite PCM-HX, and (iii) validation for a straight tube annular finned PCM-HX. The copper foam PCM-HX uses an electric heater at the top of HX, while the other two configurations utilize water as heat transfer fluid. For the single-slabbed finned PCM-HX melting case, the mean deviation in average PCM temperature predicted by the GRCM compared to the CFD model was between 0.56 – 0.73 K, with maximum temperature deviation of 2.68 K. For the HTF outlet temperature, the validation results showed that GRCM prediction matches very well with experimental data, with mean temperature deviation of 0.24 K during melting case, while for solidification case was 0.34 K. These results showcase the GRCM’s capability for accurately reproducing the thermal characteristics of PCM-HXs with considerably lower computational effort.

42 ENGINEERING↗

A careful examination of closure models in Euler–Lagrange Simulations of compressible multiphase flow in a planar shock particle curtain problem

In this work we present a comprehensive investigation of state-of-the-art closure models employed to represent interphase momentum, thermal, and work exchange between the gas and particulate phases for Euler–Lagrange (EL) simulations in shock-driven flows. A complete list of closures for the force, torque, heat transfer, and work exchange models is provided. In particular, the present work includes a stochastic closure for the particle-to-particle variation in the quasi-steady force and a deterministic closure for particle-to-particle variation in the added mass force in an EL framework. These variations arise due to the presence of neighboring particles and particle–particle interactions. To investigate the importance of each closure term, we carry out fully three-dimensional simulations for a planar shock propagating over a random bed of inert particles. The primary goal is to evaluate the role of each closure term on the gas dynamic features (such as transmitted and reflected shock locations) and particle curtain features (such as upstream and downstream curtain locations). To this end, thirteen cases are considered, with each case progressively including a closure model with the goal to identify and quantify its contribution to the simulated dynamics. We show that the volume fraction dependence of the mean force models plays an important role in generating wave-like instabilities that lead to concentration bands. In addition, fluctuations in quasi-steady and added mass forces primarily decrease the internal instabilities that tend to enhance local volume fraction variations. Particle rotation is primarily due to inter-particle collisions, is generally weak, and does not play an important role in the translational dynamics for the present configuration. Inter-phase heat transfer has a strong effect on gas phase temperature, slows down the transmitted and reflected shocks, and decreases the width of the curtain. Furthermore, the absence of a work-coupling model fails to conserve the total energy, greatly under-predicts the gas temperature which in turn affects the particle dynamics.

Compressible flow↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

Xanthos-Lake Model Source Code

This repository contains the source code for Xanthos-Lake, a lake-modeling extension of the Xanthos framework that introduces a coupled lake component comprising the Xanthos-Lake Snow and Ice Model (xLSIM) and the Xanthos-Lake Water Balance Model (xLWBM). xLSIM is a basin-aware machine-learning model for lake snow, ice, and thermal conditions. It predicts monthly lake ice thickness, snow depth, snow-cover fraction, mixing-layer temperature, and lake ice fraction from meteorological forcing and lake surface-area information. It uses sequence-based deep-learning architectures, including Transformer and hybrid Long Short-Term Memory–Transformer (LSTM–Transformer) models, together with seasonal encoding, multi-lake learning, physical masking, and basin-level cryospheric and non-cryospheric classification. The training workflow uses Ray for scalable execution and includes optional Ray Tune hyperparameter optimization. Model predictions, observations, diagnostics, and feature-importance outputs are written in NetCDF. xLWBM is the water-balance component of the new lake framework. It simulates monthly lake storage, surface area, evaporation, inflow, outflow, and lake–groundwater exchange. It combines physical water-balance equations with calibrated bathymetric relationships, weir-based outlet flow, modified Penman open-water evaporation, groundwater head relaxation, Penman–Monteith snow and ice sublimation, and snow, ice, and thermal conditions supplied by xLSIM. The model calibrates lake parameters against satellite-derived surface-area data, using evaporation-based calibration where surface-area data are unavailable, and supports small, medium, and large lake classes. For large lakes, xLWBM is integrated with the managed-routing workflow so that lake storage and outflow interact directly with downstream river routing and reservoir operations. Together, xLSIM and xLWBM provide Xanthos with a coupled lake-modeling capability. xLSIM supplies the snow, ice, and thermal conditions that affect lake evaporation and snow- and ice-related water exchanges, while xLWBM translates those conditions into dynamic lake storage, surface area, evaporation, and discharge. In return, xLWBM supplies evolving lake surface area to xLSIM. This coupling enables Xanthos to represent lakes as active hydrologic components within basin-scale water-availability and routing simulations.

Machine Learning↗

A modeling study of ocean thermal energy conversion resource and potential environmental effects around Kailua-Kona, Hawaii

Ocean Thermal Energy Conversion (OTEC) offers a promising renewable energy solution through a heat exchange process using the temperature difference between warm surface seawater and cold deep seawater. Because accurate resource characterization is critical for the optimal design and implementation of OTEC systems, a high-resolution numerical model is employed to better characterize the OTEC resource at Kona, Hawaii. Our model provides detailed spatial and temporal variability of the thermal gradient, which is essential for assessing the viability and efficiency of OTEC systems. The model results reveal distinct patterns and dynamics not captured by existing observations or models (e.g., lower-resolution information). These findings highlight the importance of using high-resolution models for accurate predictions of thermal gradient variability, ultimately supporting more efficient and sustainable OTEC deployment. Additionally, the study investigates the impacts of mixed water discharge from OTEC plants that can cause shock to organisms living in the surface water and potentially destabilize the water column. Understanding these effects is vital for minimizing any potential negative environmental consequences and ensuring the long-term viability of OTEC operations. Further, our model improves OTEC resource characterization, which can lead to optimal design and deployment of OTEC systems. The analysis of OTEC water discharge impacts can accelerate the development of OTEC technologies, overcoming permitting/consenting challenges. These findings contribute to the broader adoption of high-resolution modeling in ocean energy resource characterization, particularly for OTEC applications.

30 DIRECT ENERGY CONVERSION↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE↗

H 2 O and CO 2 Sorption in Ion-Exchange Sorbents: Distinct Interactions in Amine Versus Quaternary Ammonium Materials

This article examines how water (H₂O) and carbon dioxide (CO₂) interact with two classes of ion-exchange sorbents — a primary amine sorbent and a quaternary ammonium (QA⁺) sorbent — using calorimetry, thermal gravimetric analysis, gas analysis, and molecular modeling. Here, the QA⁺ sorbent exhibits stronger binding to both H₂O and CO₂ but also shows thermal stability limitations. Mixed-gas experiments reveal that humidity strongly influences CO₂ uptake and that moisture-driven sorbent regeneration enables cyclic moisture swing CO₂ capture, with implications for low-energy CO₂ separation from dilute gas streams.

36 MATERIALS SCIENCE↗

A Novel Framework for Performance Evaluation and Design Optimization of PCM Embedded Heat Exchangers for the Built Environment

This research sheds light on the performance evaluation and design optimization of PCM-HXs for the built environment, addressing several barriers to practical issues to PCM-HX commercialization such as modeling aspects (i.e., modeling expertise and computational / time investment, etc.), manufacturing aspects (i.e., at-scale manufacturing, cost assessments, etc.) and experimental performance assessment (i.e., reliable experimental data, assessment of multiple PCM-working fluid combinations, etc.). We present a novel, comprehensive, and experimentally-validated design optimization framework for PCM-HXs capable of simulating any PCM-HX geometry with reasonable accuracy and significant computational time savings when compared to traditional CFD-based design practices. The framework was validated for a wide range of PCM-HX configurations, including a design optimization for a domestic hot water heater application where TES partially replaces electrical heating input. The resulting PCM-HXs were found to deliver 34-68% of the total daily hot water supply with only 5-10% package volume increase from the water heater, thus within U.S. DOE targets for TES systems. To identify the most promising HXs for PCM applications, first-order geometry and cost analyses were conducted based on off-the-shelf HX products. As part of this work, 9 PCM-HX prototypes were manufactured using additive and conventional manufacturing methods. Detailed economy-of-scale assessments were conducted for the most promising PCM-HXs and were found to have a good outlook for the next 5-10 years. The PCM-HX design optimization framework was validated through comprehensive in-house experimental testing using newly-developed PCM-to-fluid test facilities. In total,10 total in-house component-level experiments were conducted using these prototypes, including 9 with water and 1 with refrigerant (R410A) as the working fluid. It was found that the framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time without manual design changes, eliminating the need for time-consuming and expensive prototyping efforts as part of the design process. As part of this work, a publicly-available PCM web tool was released which includes a PCM property database (531 PCMs) and PCM-HX modeling tool to assist the design community on common PCM-HX use-cases, e.g., single/multiple flow path(s) fluid-to-PCM and air-to-fluid-to-PCM configurations (https://ceeeweb.umd.edu/pcmapp/). This work will accelerate the design and time to market for next generation PCM-HXs.

25 ENERGY STORAGE↗

Electric Motor Thermal Management

The poster reports the accomplishments of EDT-Electric Motor Thermal Management consortium project for 2024 VTO Annual Merit Review (AMR). The overall aims of the project are to support research enabling compact, reliable, low-cost, and efficient electric machines aligned with roadmap research areas; to collaborate with ORNL, Ames, and SNL to provide motor thermal analysis support, reliability evaluation, and material measurements on related motor research at national laboratories; and collaborate with university partners including Georgia Institute of Technology and University of Wisconsin Madison to support university-led motor thermal management research efforts.

ADVANCED PROPULSION SYSTEMS↗

Operational Parameter Database for Molten Salt Thermal Energy Storage Tank Modeling

The second generation of concentrated solar power (CSP) plants is characterized by the use of a central receiver (either cavity or external), two molten nitrate salt tanks (60 wt.% NaNO 3 and 40 wt.% KNO 3 ), and a steam Rankine power-generation cycle connected through a primary heat exchanger. Molten salt thermal energy storage (TES) tanks have been widely deployed in commercial CSP plants worldwide and have been essential for increasing plant dispatchability and capacity factor, while also reducing the levelized cost of electricity (LCOE). These systems enable energy storage at the gigawatt-hour scale, typically providing 6 to 17 hours of storage duration. Despite being a commercial technology, the multiple failures observed after only a few months or years of operation in plants around the world demonstrate the technology's relative infancy and highlight the need for further research to improve its reliability. The National Laboratory of the Rockies (NLR), in collaboration with industry partners and academic and research institutions, has been leading multiple projects funded by the U.S. Department of Energy (DOE). These projects focus on addressing molten salt tank failures by improving tank design and welding fabrication practices, evaluating new alloys and weld fillers, and providing guidelines for tank commissioning and safe operation. In particular, this report presents modeling results on the effect of key tank operation parameters during 60 minutes of operation, including the mass flow rate and temperature of the salt inflow, tank salt inventory temperature, and inventory level for a representative molten salt tank design. These results form a database of tank operation behaviors that captures the effects of each specific parameter during charging, charging/discharging, and discharging processes.

14 SOLAR ENERGY↗

THM: the MOOSE thermal hydraulics module

The MOOSE Thermal Hydraulics Module (THM) is designed to facilitate the development of thermal hydraulic system models. It provides the capability to assemble networks of coupled components such as pipes, junctions, valves, turbomachinery, and heat exchangers. Its library of components supports a single-phase, compressible flow model based on a variable-area formulation of the Euler equations of gas dynamics and discretized using a finite volume scheme. THM offers a flexible system for specifying closures such as friction factors or heat transfer coefficients, allowing the user to choose from built-in correlations or define their own in the input file. A control logic system can be used to control input parameters, necessary for implementing transient scenarios and mirroring real control systems in thermal hydraulic systems. THM can be coupled with other MOOSE-based applications for multiphysics calculations. This talk will give an introduction to the capabilities of THM and provide some examples of its usage and validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MOOSE Thermal-Hydraulics Module - MOOSE workshop

The MOOSE Thermal Hydraulics Module (THM) is designed to facilitate the development of thermal hydraulic system models. It provides the capability to assemble networks of coupled components such as pipes, junctions, valves, turbomachinery, and heat exchangers. Its library of components supports a single-phase, compressible flow model based on a variable-area formulation of the Euler equations of gas dynamics and discretized using a finite volume scheme. THM offers a flexible system for specifying closures such as friction factors or heat transfer coefficients, allowing the user to choose from built-in correlations or define their own in the input file. A control logic system can be used to control input parameters, necessary for implementing transient scenarios and mirroring real control systems in thermal hydraulic systems. THM can be coupled with other MOOSE-based applications for multiphysics calculations. This training will give an introduction to the capabilities of THM and provide some examples of its usage and validation.

97 - MATHEMATICS AND COMPUTING↗