Search NASASearch

SEARCH · Search NASA

Results for “thermal power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Thermal Analysis of the Advanced Modular Power Systems (AMPS) Power Electronic Modules

In an effort to transform future space power system architectures and operations, the Advanced Modular Power Systems (AMPS) project is currently developing an interface standard for power electronic modules to enable modular architectures for space power systems. Each architecture would consist of one or more modular electronic units (MEU) that would comprise of a tailored combination of modules. The standard currently comprises modules enabling switchgear, power conversion, and data interfacing. The objective of the AMPS project is to enable the modularity and interchangeability of different architectures using these standardized modules in hopes of reducing complexity and cost, increasing inherent redundancy and reliability, and minimizing power system redesign for future programs. A key enabler to these future modular architectures will be the thermal management system, which has to contend with acquiring heat from the electronics modules at the card level and then transporting that heat to the radiator of the larger system. The focus of this paper, therefore, will be the thermal design and analysis of multiple AMPS power electronics modules and the development of their thermal-vacuum test.

Modular Power Electronics

Power and Propulsion Element Steerable High Gain Antenna Lunar Transit Thermal Analysis Tracking Methodology

The Power and Propulsion Element (PPE) is an ion thruster propulsion spacecraft developed as an element of Space Reactor (SR-1) Freedom to provide propulsion, communications and power for the spacecraft. PPE was originally being developed for the use with the lunar orbiting space station Gateway as one of the first two planned elements. PPE was to be launched with the Habitation and Logistics Outpost (HALO) element in a configuration called the Co-Manifested Vehicle (CMV) that would arrive at a Near-Rectilinear Halo Orbit (NRHO) around the Moon via a lunar transit spiral trajectory phase. The PPE communication system is equipped with two Steerable High Gain Antennas (SHGA) each steered by a two-axis gimbal (TAG) mechanism. A thermal analysis was conducted during the near-Earth spiral phase of the mission using Thermal Desktop (TD). This analysis utilized multiple axis Earth tracking articulators in combination with SINDA system internal environmental heating symbols to produce accurate Earth ground station tracking communication system temperatures. This presentation provides an overview of the communication system thermal model and the analysis methodology.

Thermal Analysis

Safe, High Power / Voltage Battery Design Challenges

NASA seeks safe, high performing battery module designs that can deliver 3C discharge rates continuously, achieve 160 Wh/kg, and is passively propagation resistant to a single cell thermal runaway event. One solution is presented that uses a patented oscillating heat pipe technology for thermal management. Combined with light weight packaging and a new commercially available gas permeable vent port, all 5 preliminary safety tests results performed to date are showing ample margins.

High power

Safe, High Power/Voltage Battery Module Design Challenges

NASA seeks to demonstrate a path for achieving safe, high power, and high performing Li-ion battery designs for the purpose of establishing design guidelines for our aeronautic and spacecraft applications. Safe means passively resistant to thermal runaway propagation of any single cell catastrophic thermal runaway. High power means capable of 3C continuous discharge without overheating. High performing means achieving > 160 Wh/kg, 200 Wh/L. The biggest challenge has been balancing a high flux light weight path for cell heat dissipation during the high rate discharge that minimizes thermal gradients between cells and also protects adjacent cells from the heat load of thermal runaway cell. Our solution includes an oscillating heat pipe spine that contacts every 18650 cell in the pack and careful cell design selection to maximize the range of initial temperatures conditions where the battery can safely complete the 3C discharge.

Thermal runaway

Advanced Space Power PEM Fuel Cell Systems

A model showing mass and heat transfer in proton exchange membrane (PEM) single cells is presented. For space applications, stack operation requiring combined water and thermal management is needed. Advanced hardware designs able to combine these two techniques are available. Test results are shown for membrane materials which can operate with sufficiently fast diffusive water transport to sustain current densities of 300 ma per square centimeter. Higher power density levels are predicted to require active water removal.

PEM

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

TVAC

Feasibility of Multi-Use Ocean Thermal Energy Conversion (OTEC) Platforms

Tropical islands and coastal communities in the United States and internationally suffer from high energy costs, unreliable electrical supplies, poverty, and underemployment, which are all being exacerbated by climate change. Multi-use Ocean Thermal Energy Conversion (OTEC) systems could align with the goals and values of these underserved and remote communities as scalable platforms that can provide baseload power, freshwater, and food, as well as potentially support new industries. The cold, nutrient-rich deep seawater needed for OTEC’s power cycles has many promising byproduct applications such as seawater air conditioning (SWAC) for residential and industrial cooling, enhancing aquaculture farms (e.g., cooling and nutrients for seaweed, shellfish, finfish), producing freshwater through desalination, and generating efuels such as ammonia and hydrogen.

16 TIDAL AND WAVE POWER

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Frontier Job-Centric Telemetry Dataset

Comprehensive analysis of high-performance computing (HPC) systems requires linking workload execution to system behavior. This kind of analysis is vital for diagnosing performance issues, managing capacity, detecting anomalous workloads, and understanding how applications interact with system hardware. This job-centric telemetry dataset unifies scheduler job records with node-level measurements, enabling direct association between workloads and their corresponding power, thermal, and performance characteristics. It contains sanitized, scheduler related metadata for 152,400 individual jobs that ran on the Frontier supercomputer and ended on selected days throughout 2024 and 2025, a subpopulation of ~6.8% of the total number of allocated jobs with non-zero run time on the system over that same period. Each is linked with files that contain telemetry time series records of the power utilization and temperature behavior of its allocated nodes and their processors during the run time of the job. Where available, a portion of the job files also contain network performance time series. Jobs are sampled from select days that reflect normal levels of user activity and possess job size distributions with large numbers of leadership class jobs (>20% of Frontier nodes). Jobs in this dataset attempt to best represent successful user workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors