Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal response functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

G-Function Library for Modeling Vertical Bore Ground Heat Exchanger

This library contains g-functions (thermal response functions) for standard, regularly spaced vertical borehole ground heat exchangers. In total, it contains 34, 321 configurations. To permit interpolation, each configuration has g-functions for heights of 24, 48, 96, 192, and 384 m. All the g-functions were calculated with burial depths of 2m, and borehole diameters of 15 to 17.5 cm, depending on height. In configurations with uniform spacing, the spacing between the boreholes is set to 5m, though it can be scaled to other horizontal spacings.

15 GEOTHERMAL ENERGY↗

Open library of g-functions for 34,321 configurations

Thermal response functions, known as g-functions, are commonly used in ground heat exchanger design tools and whole building energy simulation programs to simulate the ground heat exchanger performance. Calculation of g-functions can be quite computationally time-consuming, particularly as the number of boreholes gets large. However, once the g-function is computed, the actual simulation time can be quite short, particularly if a hybrid time-step (Cullin and Spitler 2011) approach is used. Because of this, pre-computed g-function libraries are commonly used in design tools and building simulation tools. This paper describes development of a new, publicly available library containing g-functions for 34,321 borehole field configurations; for each configuration, gfunctions are provided for 5 depths to allow interpolation between different borehole-to-height ratios. The available configurations include configurations in standard shapes: lines, rectangles, open rectangles, L-shapes, and U-shapes. It also includes new configurations: C-shapes, lopsided-U-shapes, and zoned rectangles, which are rectangular configurations with different interior and perimeter spacing of the boreholes.

Spitler, Jeffery↗

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

Thermal weights for semiclassical vibrational response functions

Semiclassical approximations to response functions can allow the calculation of linear and nonlinear spectroscopic observables from classical dynamics. Evaluating a canonical response function requires the related tasks of determining thermal weights for initial states and computing the dynamics of these states. A class of approximations for vibrational response functions employs classical trajectories at quantized values of action variables and represents the effects of the radiation-matter interaction by discontinuous transitions. Here, we evaluate choices for a thermal weight function which are consistent with this dynamical approximation. Weight functions associated with different semiclassical approximations are compared, and two forms are constructed which yield the correct linear response function for a harmonic potential at any temperature and are also correct for anharmonic potentials in the classical mechanical limit of high temperature. Approximations to the vibrational linear response function with quantized classical trajectories and proposed thermal weight functions are assessed for ensembles of one-dimensional anharmonic oscillators. This approach is shown to perform well for an anharmonic potential that is not locally harmonic over a temperature range encompassing the quantum limit of a two-level system and the limit of classical dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polymer functionalized graphene oxide and thermally responsive ion permeable membranes made therefrom

Thermally responsive materials, porous membranes comprising the thermally responsive materials, and batteries incorporating the porous membranes as thermally responsive separation membranes are provided. Also provided are methods of making the thermally responsive materials. The thermally responsive materials comprise upper critical solution temperature (UCST) polymers covalently bound to a support substrate.

Kung, Harold H.↗

Electron thermalization and relaxation in laser-heated nickel by few-femtosecond core-level transient absorption spectroscopy

Direct measurements of photoexcited carrier dynamics in nickel are made using few-femtosecond extreme ultraviolet (XUV) transient absorption spectroscopy at the nickel M 2,3 edge. It is observed that the core-level absorption line shape of photoexcited nickel can be described by a Gaussian broadening (σ) and a red shift (ω s ) of the ground-state absorption spectrum. Theory predicts and the experimental results verify that after initial rapid carrier thermalization, the electron temperature increase (ΔT ) is linearly proportional to the Gaussian broadening factor σ, providing quantitative real-time tracking of the relaxation of the electron temperature. Measurements reveal an electron cooling time for 50 nm thick polycrystalline nickel films of 640 ± 80 fs. With hot thermalized carriers, the spectral red shift exhibits a power-law relationship with the change in electron temperature of ω s ∝ ΔT 1.5 . Rapid electron thermalization via carrier-carrier scattering accompanies and follows the nominal 4-fs photoexcitation pulse until the carriers reach a quasithermal equilibrium. Entwined with a <6 fs instrument response function, carrier thermalization times ranging from 34 fs to 13 fs are estimated from experimental data acquired at different pump fluences and it is observed that the electron thermalization time decreases with increasing pump fluence. Here, the study provides an initial example of measuring electron temperature and thermalization in metals in real time with XUV light, and it lays a foundation for further investigation of photoinduced phase transitions and carrier transport in metals with core-level absorption spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical Actuation via Homeomorphic Transformations of Topological Solitons within Polymer Coatings

Abstract Topological solitons are currently under investigation for their exotic properties, especially in nonlinear physics, optics, and material sciences. However, challenges of robust generation and limited stability over time have hindered their practical uses. To address this issue, an approach is developed to form structured arrays of solitons in films of polymerizable liquid crystals. Their complex molecular architecture is preserved by in situ photopolymerization forming a stable liquid crystal network. Most excitingly, their properties are advanced to include responsiveness functions. When thermally actuated, these topological solitons mediate the reconfiguration of surface topographies. Complex shape changes occur depending on the intrinsic complex spatial distribution of the director, which may even lead to full shape inversion and topographical changes as high as ≈40% of the initial thickness. Conversely, the shape changes provide information on the initial director profile, which is consistent with the mathematical model. The soliton‐containing polymer coatings are applicable in multiple domains, ranging from tunable optics to haptics, and from shape‐coupled sensing systems to temperature‐coupled heat management.

36 MATERIALS SCIENCE↗

Dispersion in a thermal plasma including arbitrary degeneracy and quantum recoil

The longitudinal response function for a thermal electron gas is calculated including two quantum effects exactly, degeneracy, and the quantum recoil. The Fermi-Dirac distribution is expanded in powers of a parameter that is small in the nondegenerate limit and the response function is evaluated in terms of the conventional plasma dispersion function to arbitrary order in this parameter. The infinite sum is performed in terms of polylogarithms in the long-wavelength and quasistatic limits, giving results that apply for arbitrary degeneracy. The results are applied to the dispersion relations for Langmuir waves and to screening, reproducing known results in the nondegenerate and completely degenerate limits, and generalizing them to arbitrary degeneracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal responses of dissolved organic matter under global change

The diversity of intrinsic traits of different organic matter molecules makes it challenging to predict how they, and therefore the global carbon cycle, will respond to climate change. Here we develop an indicator of compositional-level environmental response for dissolved organic matter to quantify the aggregated response of individual molecules that positively and negatively associate with warming. We apply the indicator to assess the thermal response of sediment dissolved organic matter in 480 aquatic microcosms along nutrient gradients on three Eurasian mountainsides. Organic molecules consistently respond to temperature change within and across contrasting climate zones. At a compositional level, dissolved organic matter in warmer sites has a stronger thermal response and shows functional reorganization towards molecules with lower thermodynamic favorability for microbial decomposition. The thermal response is more sensitive to warming at higher nutrients, with increased sensitivity of up to 22% for each additional 1 mg L -1 of nitrogen loading. The utility of the thermal response indicator is further confirmed by laboratory experiments and reveals its positive links to greenhouse gas emissions.

54 ENVIRONMENTAL SCIENCES↗

Thermal Density Functional Theory: Time-Dependent Linear Response and Approximate Functionals from the Fluctuation-Dissipation Theorem

We present that the van Leeuwen proof of linear-response time-dependent density functional theory (TDDFT) is generalized to thermal ensembles. This allows generalization to finite temperatures of the Gross-Kohn relation, the exchange-correlation kernel of TDDFT, and fluctuation dissipation theorem for DFT. Finally, this produces a natural method for generating new thermal exchange-correlation approximations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parallelized Quadrupole Simulations of Thermographic Responses of Composites

Thermography has been shown to be a viable technique for inspection of composites. Model inversion of the thermography data requires a fast method for performing the forward problem. Viable numerical methods for the thermal response forward problem are finite element, finite difference and the quadrupole method. Normally both the finite element and finite difference methods solve for the thermal response in the time domain which limits one’s ability to increase the speed of the simulation by parallelization. In contrast, the quadrupole method solves for the Laplace transform of the thermal response. One of the features of the Laplace transform methodology is the solution at any discrete time is independent of the solution at all other times. Therefore, it is easy to separate into a set of independent calculations with each of the times of interest being performed in parallel. Additionally, the numeric inversion of the Laplace transform typically involves numerically solving for the Laplace transform at multiple Laplace frequencies. Each of those solutions are also independent of solutions at other frequencies and can be calculated in parallel. By parallelization of this method, it is possible to perform the simulations of three-dimensional configurations in seconds. When the input stimulus for thermal response is a delta function heat flux (a reasonable approximation for flash heating), the thermal response is smooth. For this case, it is possible to accurately estimate the thermal response at any time within a given time interval from a set of simulations separated by exponentially increasing time steps. From these simulations, it is possible to accurately interpolate to find the response at intermediate times by a spline interpolation of the logarithm of time versus logarithm of temperature. The thermal response with exponential time stepping is shown to produce values for the thermal response which are within 1% of values within the time interval. The simulations are compared to finite element simulations of the same inspection configurations. The simulations are also compared to the thermographic measurements on composites where shape and depth of the delaminations are obtained from other inspection methods.

Thermography↗

Parallelized Quadrupole Simulations of Thermographic Responses of Composites

Thermography has been shown to be a viable technique for inspection of composites. Model inversion of the thermography data requires a fast method for performing the forward problem. Viable numerical methods for the thermal response forward problem are finite element, finite difference and the quadrupole method. Normally both the finite element and finite difference methods solve for the thermal response in the time domain which limits one’s ability to increase the speed of the simulation by parallelization. In contrast, the quadrupole method solves for the Laplace transform of the thermal response. One of the features of the Laplace transform methodology is the solution at any discrete time is independent of the solution at all other times. Therefore, it is easy to separate into a set of independent calculations with each of the times of interest being performed in parallel. Additionally, the numeric inversion of the Laplace transform typically involves numerically solving for the Laplace transform at multiple Laplace frequencies. Each of those solutions are also independent of solutions at other frequencies and can be calculated in parallel. By parallelization of this method, it is possible to perform the simulations of three-dimensional configurations in seconds. When the input stimulus for thermal response is a delta function heat flux (a reasonable approximation for flash heating), the thermal response is smooth. For this case, it is possible to accurately estimate the thermal response at any time within a given time interval from a set of simulations separated by exponentially increasing time steps. From these simulations, it is possible to accurately interpolate to find the response at intermediate times by a spline interpolation of the logarithm of time versus logarithm of temperature. The thermal response with exponential time stepping is shown to produce values for the thermal response which are within 1% of values within the time interval. The simulations are compared to finite element simulations of the same inspection configurations. The simulations are also compared to the thermographic measurements on composites where shape and depth of the delaminations are obtained from other inspection methods.

Thermography↗

Fatigue-induced Reversible/Irreversible Structural-transformation Study of a Ni-based Superalloy Using Combined In-situ Neutron-Diffraction and Thermal Approaches

Cyclic loading and the subsequent fatigue damage have been investigated with the in-situ neutron-diffraction and thermal characterization for a single-phase, polycrystal nickel-based alloy. The lattice-strain evolution is compared with the bulk parameters, such as the applied stress and the thermal response as a function of the fatigue cycles. The in-situ neutron-diffraction and thermal-evolution results identify the development of the five fatigue-damage stages. Fatigue damage is observed with bulk hardening, softening, and eventual saturation evident in both the diffraction patterns and the thermal-evolution features. An increase in the dislocation density and the formation of the patterned-dislocation structure are responsible for hardening within the early cycles. With further cyclic loading, the rearrangements of the dislocations result in the cyclic softening. The transition to saturation cycles is characterized by the anisotropy of the lattice strain evolution. The nonmonotonic thermal response and the irreversible anisotropy of the lattice-strain evolution are observed in the final saturation fatigue cycles. The fatigue-damage microstructure and dislocation-substructure evolution are studied with diffraction-profile analyses and complemented by the transmission-electron microscopy. The fluctuations of the differential dislocation density and size of the patterned substructure along with the in-situ thermal measurements reveal a second-order-kind structural transition and indicate the development of the irreversible fatigue-induced microstructure.

36 MATERIALS SCIENCE↗

Modeling and Validation of the Thermal Response of TDI Encapsulating Foam as a function of Initial Density

TDI foams of nominal density from 10 to 45 pound per cubic foot were decomposed within a heated stainless steel container. The pressure in the container and temperatures measured by thermocouples were recorded with each test proceeding to an allowed maximum pressure before venting. Two replicate tests for each of four densities and two orientations in gravity produced very consistent pressure histories. Some thermal responses demonstrate random sudden temperature increases due to decomposition product movement. The pressurization of the container due to the generation of gaseous products is more rapid for denser foams. When heating in the inverted orientation, where gravity is in the opposite direction of the applied heat flux, the liquefied decomposition products move towards the heated plate and the pressure rises more rapidly than in the upright configuration. This effect is present at all the densities tested but becomes more pronounced as density of the foam is decreased. A thermochemical material model implemented in a transient conduction model solved with the finite element method was compared to the test data. The expected uncertainty of the model was estimated using the mean value method and importance factors for the uncertain parameters were estimated. The model that was assessed does not consider the effect of liquefaction or movement of gases. The result of the comparison is that the model uncertainty estimates do not account for the variation in orientation (no gravitational affects are in the model) and therefore the pressure predictions are not distinguishable due to orientation. Temperature predictions were generally in good agreement with the experimental data. Predictions for response locations on the outside of the can benefit from reliable estimates associated with conduction in the metal. For the lighter foams, temperatures measured on the embedded component fall well with the estimated uncertainty intervals indicating the energy transport rate through the decomposed region appears to be accurately estimated. The denser foam tests were terminated at maximum allowed pressure earlier resulting in only small responses at the component. For all densities the following statements are valid: The temperature response of the embedded component in the container depends on the effective conductivity of the foam which attempts to model energy transport through the decomposed foam and on the stainless steel specific heat. The pressure response depends on the activation energy of the reactions and the density of the foam and the foam specific heat and effective conductivity. The temperature responses of other container locations depend heavily on the boundary conditions and the stainless steel conductivity and specific heat.

36 MATERIALS SCIENCE↗

Characterization of the thermal conductivity for Advanced Toughened Uni-piece Fibrous Insulations

Advanced Toughened Uni-piece Fibrous Insulations (TUFI) is discussed in terms of their thermal response to an arc-jet air stream. A modification of the existing Ames thermal conductivity program to predict the thermal response of these functionally gradient materials is described in the paper. The modified program was used to evaluate the effect of density, surface porosity, and density gradient through the TUFI materials on the thermal response of these insulations. Predictions using a finite-difference code and calculated thermal conductivity values from the modified program were compared with in-depth temperature measurements taken from TUFI insulations during short exposures to arc-jet hypersonic air streams.

Stewart, David A.↗

OBSERVATIONAL SIGNATURES OF THE CORONAL KINK INSTABILITY WITH THERMAL CONDUCTION

It is known from numerical simulations that thermal conduction along magnetic field lines plays an important role in the evolution of the kink instability in coronal loops. This study presents the observational signatures of the kink instability in long coronal loops when parallel thermal conduction is included. The three-dimensional nonlinear magnetohydrodynamic equations are solved numerically to simulate the evolution of a coronal loop that is initially in an unstable equilibrium. The loop has length 80 Mm, width 8 Mm, and an initial maximum twist of {Phi} = 11.5{pi}, where {Phi} is a function of the radius. The initial loop parameters are obtained from a highly twisted loop observed in the Transition Region and Coronal Explorer (TRACE) 171 A wave band. Synthetic observables are generated from the data. These observables include spatial and temporal averaging to account for the resolution and exposure times of TRACE images. Parallel thermal conduction reduces the maximum local temperature by up to an order of magnitude. This means that different spectral lines are formed and different internal loop structures are visible with or without the inclusion of thermal conduction. However, the response functions sample a broad range of temperatures. The result is that the inclusion of parallel thermal conductivity does not have as large an impact on observational signatures as the order of magnitude reduction in the maximum temperature would suggest; the net effect is a blurring of internal features of the loop structure.

79 ASTRONOMY AND ASTROPHYSICS↗