Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal striping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High–Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next–generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds–averaged Navier–Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

97 MATHEMATICS AND COMPUTING↗

Requirements Description of DASSH-F

This report reviews the modeling and simulation capabilities of Argonne National Laboratory’s DASSH code that is used in present reactor analysis activities. These capabilities will be used to establish the set of verification tasks necessary to verify DASSH for use on commercial projects. A similar approach was taken for the PERSENT, REBUS and DIF3D software packages. The DASSH program is a thermal analysis code designed to rapidly allow a reactor design engineer to obtain flow rates requirements that satisfy peak temperature constraints in the domain. DASSH is a follow-on development to the SE2-ANL software and SUPERENERGY-2 software that it is based upon. DASSH was designed to account for both neutron and gamma heating and is inherently connected to the GAMSOR part of the ARC suite of fast reactor analysis software. SE2-ANL is a developed piece of software from the 1980s while DASSH is a modern implementation with notable improvements in geometry handling. The most important upgrade of DASSH relative to SE2-ANL is that it can analyze multiple time points in a single run where SE2-ANL can only treat a single time point. This allows the user to understand the impact of and search the flow distribution for the entire operational period of a reactor design considering pressure drop, peak coolant and fuel temperatures, and thermal striping. DASSH has three input paths that have to be verified. The first input path builds the geometry and power distribution based upon the DIF3D model but ignores the gamma heating aspects of the problem. The second input path also builds the geometry from the DIF3D model but it takes the neutron and gamma heating distributions from GAMSOR. The third input path is to take the geometry and power distribution directly from user input (i.e. not coupled to DIF3D or GAMSOR). DASSH also has many built in correlations for material properties along with a user defined specification of the fuel, structure, and coolant properties. There are correlations for flow split, mixing, pressure drop, and heat transfer coefficients (subchannel rather than a direct methodology). In total, verification of DASSH will require an extensive testing to cover all possible user features of the software.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Potential capabilities of Reynolds stress turbulence model in the COMMIX-RSM code

A Reynolds stress turbulence model has been implemented in the COMMIX code, together with transport equations describing turbulent heat fluxes, variance of temperature fluctuations, and dissipation of turbulence kinetic energy. The model has been verified partially by simulating homogeneous turbulent shear flow, and stable and unstable stratified shear flows with strong buoyancy-suppressing or enhancing turbulence. This article outlines the model, explains the verifications performed thus far, and discusses potential applications of the COMMIX-RSM code in several domains, including, but not limited to, analysis of thermal striping in engineering systems, simulation of turbulence in combustors, and predictions of bubbly and particulate flows.

Chang, F. C.↗

CIRS-lite, a Fourier Transform Spectrometer for Low-Cost Planetary Missions

Passive spectroscopic remote sensing of planetary atmospheres and surfaces in the thermal infrared is a powerful tool for obtaining information about surface and atmospheric temperatures, composition, and dynamics (via the thermal wind equation). Due to its broad spectral coverage, the Fourier transform spectrometer (FTS) is particularly suited to the exploration and discovery of molecular species. NASA's Goddard Space Flight Center (GSFC) developed the CIRS (Composite Infrared Spectrometer) FTS for the NASA/ESA Cassini mission to the Saturnian system. CIRS observes Saturn, Titan, icy moons such as Enceladus, and the rings in thermal self-emission over the spectral range of 7 to 1000 ell11. CIRS has given us important new insights into stratospheric composition and jets on Jupiter and Saturn, the cryo-geyser and thermal stripes on Enceladus, and the winter polar vortex on Titan. CIRS has a mass of 43 kg, contrasted with the earlier GSFC FTS, pre-Voyager IRIS (14 kg). Future low-cost planetary missions will have very tight constraints on science payload mass, thus we must endeavor to return to IRIS-level mass while maintaining CIRS-level science capabilities ("do more with less"). CIRS-lite achieves this by pursuing: a) more sensitive infrared detectors (high Tc superconductor) to enable smaller optics. b) changed long wavelength limit from 1000 to 300 microns to reduce diffraction by smaller optics. c) CVD (chemical vapor deposition) diamond beam-splitter for broad spectral coverage. d) single FTS architecture instead of a dual FTS architecture. e) novel materials, such as single crystal silicon for the input telescope primary.

Brasunas, J.↗

CIRS and CIRS-Lite as Designed for the Outer Planets: TSSM, EJSM, JUICE

Passive spectroscopic remote sensing of planetary atmospheres and surfaces in the thermal infrared is a powerful tool for obtaining information about surface and atmospheric temperatures, composition, and dynamics (via the thermal wind equation). Due to its broad spectral coverage, the Fourier transform spectrometer (FTS) is particularly suited to the exploration and discovery of molecular species. NASA Goddard's Cassini CIRS FTS has given us important new insights into stratospheric composition and jets on Jupiter and Saturn, the cryo-vo1cano and thermal stripes on Enceladus, and the polar vortex on Titan. We have designed a lightweight successor to CIRS - called CIRS-lite - with improved spectral resolution to separate blended spectral lines (such as occur with isotopes). CIRS-lite includes four key components: (1) high Tc superconductor bolometer/carbon nano-tube (CNT) absorber (approx 87K, YBCO) (2) synthetic diamond beam splitter (approx 140K) (3) moving mirror mechanism with crossed-roller bearings ( approx 110 K) (4) single crystal silicon for the input telescope primary

Brasunas, J.↗

Induced junction solar cell and method of fabrication

An induced junction solar cell is fabricated on a p-type silicon substrate by first diffusing a grid of criss-crossed current collecting n+ stripes and thermally growing a thin SiO2 film, and then, using silicon-rich chemical vapor deposition (CVD), producing a layer of SiO2 having inherent defects, such as silicon interstices, which function as deep traps for spontaneous positive charges. Ion implantation increases the stable positive charge distribution for a greater inversion layer in the p-type silicon near the surface. After etching through the oxide to parallel collecting stripes, a pattern of metal is produced consisting of a set of contact stripes over the exposed collecting stripes and a diamond shaped pattern which functions as a current collection bus. Then the reverse side is metallized.

Maserjian, J.↗

Quantifying and Characterizing Striping of Microwave Humidity Sounder with Observation and Simulation

Striping has been observed in the MetOp-A Microwave Humidity Sounder (MHS) data since its degradation in November 2018. However, accurate striping quantification and characterization remain challenging due to the large scene dynamics observed at W/G bands of MHS. Here we have developed a set of novel algorithms for striping quantification, decomposition, characterization, and simulation. Our algorithm extracts striping from the warm-load and cold-space scenes that are relatively stable. We break down the striping into two parts of thermal and 1/f noise and quantify their absolute magnitude and relative ratio. We found a significant increase in striping at 157 GHz that has more than quadrupled by October 2019 relative to its normal level. Regardless of the degradation, the ratio of thermal and 1/f noise remains the same. Our simulation reproduces all the characteristics of striping against observation. It is shown that 1/f noise generates sharp, non-periodic stripes, while thermal noise also generates stripes but with smoother band features. The latter is due to the periodic calibration that has a chopping effect. The striping percentage, defined as the ratio of 1/f to total noise, shows no dependence on the scene temperature. Striping is pronounced not only in 157 GHz but also in 89 and190 GHz with the striping percentage over 50%, while lower in183 GHz of 20%. The results provide insights for quantifying and understanding striping. Our algorithm can be applied to other radiometers and to simulate striping for evaluating its impact in data assimilation and science products.

John Xun Yang↗

On-Orbit Performance of the NOAA-21 Advanced Technology Microwave Sounder (ATMS)

The Advanced Technology Microwave Sounder (ATMS) instrument provides sounding measurements of Earth’s atmosphere to collect temperature and water vapor data for NOAA’s Joint Polar Satellite System (JPSS) program. ATMS is a total-power passive microwave radiometer with 22 channels spanning a frequency range from 22 to 183 GHz. A general description of the ATMS instrument is detailed in [1]. Three ATMS units are currently on-orbit. The Suomi National Polar-orbiting Partnership (SNPP) unit was launched in 2011 and the NOAA-20 (previously JPSS-1) unit was launch in 2017. Both SNPP and NOAA-20 ATMS units are currently operational and the data is used for numerical weather prediction (NWP) models. The NOAA-21 (formerly JPSS-2) ATMS unit was launched on November 10, 2022 from Vandenberg Space Force Base in California [2]. The ATMS instrument began generating radiance data on November 21, 2022. At the time of this abstract NOAA-21 ATMS is currently completing on-orbit commissioning and checkout activities; it is expected that the commissioning activities will be complete by the IGARSS 2023 conference. This paper will focus on the on-orbit performance of the NOAA-21 ATMS instrument based on measurements and activities from the commissioning period. Comparisons will be made to specifications and to expected performance based on pre-launch test activities. Pre-launch JPSS-2 (NOAA-21) ATMS performance is detailed in [4]. Additionally, the NOAA-21 performance will be compared to the on-orbit performance of the SNPP and NOAA-21 ATMS units. The post-launch performance of SNPP ATMS is detailed in [1][5][6][7]. The post-launch performance of NOAA-20 ATMS is detailed in [5][7][8]. On-orbit performance is evaluated through data collects from nominal mission operations as well as specific post-launch tests and spacecraft maneuvers. Nominal mission operations can be used to evaluate parameters such as instrument thermal stability, Noise Equivalent Delta Temperature (NEDT)/radiometric sensitivity, geolocation, inter-channel noise correlation, striping, and radiometric bias and stability. Shortly after instrument activation, the instrument thermal stability as measured from onboard temperature sensors is evaluated to demonstrate stable and steady-state behavior. Methods for computing NEDT are described in [9][10][11]. Passive geolocation measurements are performed using the coastline inflection point (CIP) method, described in [8][12]. The striping index, used as a metric to quantify striping, is the ratio of along-track variance to cross-track variance of the observed brightness temperature [4][8][14]. Inter-channel noise correlation has been previously reported for SNPP and NOAA-20 [1][8]. Dedicated post-launch tests and spacecraft maneuvers are utilized during the commissioning phase for further evaluation of on-orbit instrument performance. These activities provide information on the optimal space view selection, noise power spectral density (PSD), gain stability, scan bias, interference from onboard transmitters, reflector emissivity, active geolocation, and radiometric bias and stability detection methods. The optimal space view selection is used to determine which of ATMS space view sectors is preferred for minimizing contamination of the space view [1]. Point and stare testing is used to generate noise PSD and gain stability information, as described in [1][8]. Spacecraft roll and pitch maneuvers allow the ATMS to view different zones, including deep space, and the data can be used to provide information on scan biases and antenna sidelobe contamination [1][8]. The pitch maneuver can also be used to assess interference from onboard Ka-band transmitters and reflector emissivity [8]. Active geolocation is evaluated as a method for geolocation, described in [15].

Edward Kim↗

Hawai’i Climate: Utilizing NASA Earth Observations to Assess Thermal Stress Impacts on Coastal Hawaiian Fishponds

Hawaiian fishponds (loko i’a), ancient aquaculture systems created over 1500 years ago, historically served to harvest prized native fish species. Colonization-induced changes in land management have reduced active loko i’a from over 500 to ~20, destabilizing nearshore ecosystems and diminishing native Hawaiian cultural traditions. In recent decades, efforts to restore loko i’a have intensified as part of a broader emphasis on preserving Hawaiian cultural identity. Anthropogenic-induced climate change threatens these systems, particularly through the increase in frequency and magnitude of marine heatwaves. Though largely unexplored, these events are effectively studied utilizing remote sensing via Earth observations. Leveraging this technique enables autonomous extraction of water quality parameters to inform fishpond management. This study examined seven loko i’a across the main Hawaiian Islands (Hawai’i Island, Moloka’i, Maui, O’ahu, Kaua’i). Sea surface temperature and normalized difference chlorophyll index measurements were derived in fishponds utilizing Landsat 8 Thermal Infrared Sensor Thermal Infrared Sensor and Sentinel-2 MultiSpectral Instrument between 2013 to 2023, while regional patterns in temperature and chlorophyll-a were observed via Aqua’s Moderate Resolution Imaging Spectroradiometer (2002-2021). Employing these sensors, we focused analysis around the 2015 and 2019 marine heatwaves in the Pacific. We observed a heat stress gradient across the archipelago, creating thermally sheltered and unsheltered fishponds, yet identified no notable localized relationships between temperature and chlorophyll-a. Additionally, we applied pre-determined thermal maxima for culturally significant fish species (Striped Mullet: Mugil cephalus; Milkfish: Chanos Chanos) to assess historical habitat suitability within fishponds. While the direct impacts of marine heatwaves on loko i’a ecology are unknown, temperature patterns observed in this study are cause for concern.

Raz Wachtel↗

Symmetry breaking during low-temperature domain formation in micron-sized magnetite crystals

We report the results of synchrotron Bragg Coherent x-ray Diffraction Imaging (BCDI) experiments to investigate domain formation in a micron-sized magnetite crystal undergoing the Verwey transition at low temperature. A strong splitting of the measured 311 Bragg reflection was observed in the low-temperature phase, indicating the formation of domains. BCDI revealed pronounced strain distributions, characterized by a clear layered stripe domain structure in real-space. Stripes were seen only along the [001] crystallographic direction, normal to the substrate surface direction, breaking the symmetry of the cubic high-temperature phase. It is argued that other domain directions were suppressed by the sample mounting orientation. More surprisingly, only a single domain orientation was observed, suggesting an additional symmetry-breaking influence originating from the shape of the crystal. Gaining insight into how thermal effects induce the formation of layered or striped phases offers a valuable framework for understanding the development of mesoscopic domains and strain patterns in functional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Localizing the non-thermal X-ray emission of PSR J2229+6114 from its multi-wavelength pulse profiles

Context.Pulsars are detected over the whole electromagnetic spectrum, from radio wavelengths up to very high energies, in the GeV-TeV range. While the radio emission site for young pulsars is well constrained to occur at altitudes about several percent of the light-cylinder radius andγ-ray emission is believed to be produced in the striped wind, outside the light cylinder, the non-thermal X-ray production site remains unknown. Aims.The aim of this Letter is to localize the non-thermal X-ray emission region based on a multi-wavelength pulse profile fitting for PSR J2229+6114, which stands as a particularly good candidate given its high X-ray brightness. Methods.Based on the geometry deduced from the joint radio andγ-ray pulse profiles, we fixed the magnetic axis inclination angle and the line-of-sight (LoS) inclination angle. However, we left the region of X-ray emission unlocalized, setting it somewhere between the surface and the light cylinder. We localized this region and its extension by fitting the X-ray pulse profile as observed by the NICER,NuSTAR, and RXTE telescopes in the ranges of 2–7 keV, 3–10 keV, and 9.4–22.4 keV, respectively. Results.We constrained the non-thermal X-ray emission to arise from altitudes between 0.2 r L and 0.55 r L wherer L is the light-cylinder radius. The magnetic obliquity is approximatelyα ≈ 45° −50° and the LoS inclination angle isζ ≈ 32° −48°. Conclusions.This Letter is among the first works to offer a tight constraint on the location of non-thermal X-ray emission from pulsars. We plan to apply this procedure to several other promising candidates to confirm this new result.

Astronomy & Astrophysics↗

MURR LEU structural and thermal hydraulics analyses: Part I – Preliminary irradiation thermo-mechanical behavior

The University of Missouri Research Reactor (MURR) is expected to be converted from highly enriched uranium (HEU, ≥ 20 wt% U-235) U-Al x dispersion fuel to low-enriched uranium (LEU, < 20 wt% U-235) with U-10Mo monolithic fuel. This work introduces high-fidelity irradiation thermo–mechanical (T-M) analysis of the MURR LEU focusing on changes in coolant channel gap thickness. Three-dimensional (3D) finite element (FE) models were developed to simulate the irradiation T-M behavior of the MURR LEU element with all 23 curved fuel plates, the two side plates, and the combs. It was shown that channel gap thickness changes were influenced not only by plate thickness variations due to fuel swelling and creep but also by the radial displacement of consecutive MURR LEU plates. Modeling the fuel element assembly captured side plate displacements, which were shown to reduce radial fuel plate displacements towards the convex side. The maximum local radial displacement in the element was predicted at the end of life (EOL) as 23.7 mil (602.0 µm) on the lateral centerline of plate 23 towards the convex side. The maximum stripe-averaged reduction in channel gap thickness, particularly relevant for thermal hydraulics (TH) safety analysis, was calculated as 15.9 mil (403.9 µm) in single-side heated channel 24 (the outermost channel). These results account for the thermal resistance from the oxide build-up on cladding surfaces which was shown to be up to 0.82 mil (20.8 µm) thick. It was demonstrated that accounting for oxide layer thermal resistance led to a 10 °C higher peak fuel temperature and a 4.4 mil (111.8 µm) greater maximum local radial displacement. The impact of the calculated channel gap thickness changes on the MURR LEU TH safety analysis is evaluated in Part II.

Irradiation thermo-mechanical analysis↗

Performance of an X-Ray Microcalorimeter with a 240 Micron Absorber and a 50 Micron TES Bilayer

We have been developing superconducting transition-edge sensor (TES) microcalorimeters for a variety of potential astrophysics missions, including Athena. The X-ray Integral Field Unit (X-IFU) instrument on this mission requires close-packed pixels on a 0.25 mm pitch, and high quantum efficiency between 0.2 and 12 keV. The traditional approach within our group has been to use square TES bilayers on molybdenum and gold that are between 100 and 140 microns in size, deposited on silicon nitride membranes to provide a weak thermal conductance to a 50 mK heat bath temperature. It has been shown that normal metal stripes on top of the bilayer are needed to keep the unexplained noise at a level consistent with the expected based upon estimates for the non-equilibrium non-linear Johnson noise.In this work we describe a new approach in which we use a square TES bilayer that is 50 microns in size. While the weak link effect is much stronger in this size of TES, we have found that excellent spectral performance can be achieved without the need for any normal metal strips on top of the TES. A spectral performance of 1.58 eV at 6 KeV has been achieved, the best resolution seen in any of our devices with this pixel size. The absence of normal metal stripes has led to more uniform transition shapes, and more reliable excellent spectral performance. The smaller TES size has meant that that the thermal conductance to the heat bath, determined by the perimeter length of the TES and the membrane thickness, is lower than on previous devices, and thus has a lower count rate capability. This is an advantage for low count-rate applications where the slower speed enables easier multiplexing in the read-out, thus potential higher multiplexing factors. In order to recover the higher count rate capabilities, a potential path exits using thicker silicon nitride membranes to increase the thermal conductance to the heat bath.

Miniussi, Antoine R.↗