Search NASASearch

SEARCH · Search NASA

Results for “thermo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Thermo‐Flow‐Mechanics‐Fracture Model Coupling a Phase‐Field Interface Approach and Thermo‐Fluid‐Structure Interaction

This work proposes a novel approach for coupling non-isothermal fluid dynamics with fracture mechanics to capture thermal effects within fluid-filled fractures accurately. This method addresses critical aspects of calculating fracture width in enhanced geothermal systems, where the temperature effects of fractures are crucial. The proposed algorithm features an iterative coupling between an interface-capturing phase-field fracture method and interface-tracking thermo-fluid-structure interaction using arbitrary Lagrangian–Eulerian coordinates. We use a phase-field approach to represent fractures and reconstruct the geometry to frame a thermo-fluid-structure interaction problem, resulting in pressure and temperature fields that drive fracture propagation. We developed a novel phase-field interface model accounting for thermal effects, enabling the coupling of quantities specific to the fluid-filled fracture with the phase-field model through the interface between the fracture and the intact solid domain. We provide several numerical examples to demonstrate the capabilities of the proposed algorithm. In particular, we analyze mesh convergence of our phase-field interface model, investigate the effects of temperature on crack width and volume in a static regime, and highlight the method's potential for modeling slowly propagating fractures.

fracture

Global and regional perspectives on optimizing thermo-responsive dynamic windows for energy-efficient buildings

Architectural thermo-responsive dynamic windows offer an autonomous solution for solar heat regulation, thereby reducing building energy consumption. Previous work has emphasized the significance of thermo-responsive windows in hot climates due to their role in solar heat control and subsequent energy conservation; conversely, our study provides a different perspective. Through a global-scale analysis, we explore over 100 material samples and execute more than 2.8 million simulations across over two thousand global locations. World heatmap results, derived from well-trained artificial neural network models, reveal that thermo-responsive windows are especially useful in climates where buildings demand both heating and cooling energy, whereas thermo-responsive windows with optimal transition temperatures show no dynamic features in most of low-latitude tropical regions. Additionally, this study provides a practical guideline and an open-source mapping tool to optimize the intrinsic properties of thermo-responsive materials and evaluate their energy performance for sustainable buildings at various geographical scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

MURR LEU structural and thermal hydraulics analyses: Part II – Impacts of irradiation thermo-mechanical behavior on thermal hydraulics safety analyses

A series of structural analyses have been performed to support the conversion of the University of Missouri Research Reactor (MURR) from the use of highly enriched uranium (HEU; ≥20 wt% U-235) to low-enriched uranium (LEU; <20 wt% U-235) fuel. The irradiation thermo-mechanical analysis evaluated the effects of fuel swelling, irradiation creep, thermal expansion, as well as thermal resistance from the oxide layer growth for the MURR LEU element in prototypic thermal and irradiation conditions as presented in Part I of this article. Overall, this irradiation thermo-mechanical analysis predicts smaller gap thickness reductions in previously limiting regions, and larger reductions in the middle of the outermost end channels where power density is not typically a maximum. Due to substantial differences between the channel gap reductions assumed for the previous safety analyses and those predicted by the irradiation thermo-mechanical analysis, a need to evaluate their impact on the thermal hydraulics safety analyses arose. This article presents the results from the steady-state safety analysis for normal operation as well as the two most limiting accident scenarios. The calculation models were revised in order to account for the spatial and temporal variation of the channel gap thicknesses. The results show that sufficient safety margins are still maintained for normal operation as well as during the postulated accident transients. This work provides a methodology of incorporating the irradiation thermo-mechanical behavior of plate-type fuel into the thermal hydraulics safety analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Commissioning of the Liquid Nitrogen Thermo-Siphon System for NASA-JSC Chamber-A

NASA's Space Environment Simulation Laboratory's (SESL) Chamber A, located at the Johnson Space Center in Houston Texas has recently implemented major enhancements of its cryogenic and vacuum systems. The new liquid nitrogen (LN2) thermo-siphon system was successfully commissioned in August of 2012. Chamber A, which has 20 K helium cryo-panels (or shrouds ) which are shielded by 80 K nitrogen shrouds, is capable of simulating a deep space environment necessary to perform ground testing of NASA s James Webb Space Telescope (JWST). Chamber A s previous system used forced flow LN2 cooling with centrifugal pumps, requiring 200,000 liters of LN2 to cool-down and consuming 180,000 liters per day of LN2 in steady operation. The LN2 system did not have the reliability required to meet the long duration test of the JWST, and the cost estimate provided in the initial approach to NASA-JSC by the sub-contractor for refurbishment of the system to meet the reliability goals was prohibitive. At NASA-JSC's request, the JLab Cryogenics Group provided alternative options in 2007, including a thermo-siphon, or natural flow system. This system, eliminated the need for pumps and used one tenth of the original control valves, relief valves, and burst disks. After the thermo-siphon approach was selected, JLab provided technical assistance in the process design, mechanical design, component specification development and commissioning oversight, while the installation and commissioning operations of the system was overseen by the Jacobs Technology/ESC group at JSC. The preliminary commissioning data indicate lower shroud temperatures, 70,000 liters to cool-down and less than 90,000 liters per day consumed in steady operation. All of the performance capabilities have exceeded the design goals. This paper will outline the comparison between the original system and the predicted results of the selected design option, and the commissioning results of thermo-siphon system.

Homan, J.

Commissioning of the Liquid Nitrogen Thermo-Siphon System for NASA-JSC Chamber A

NASA s Space Environment Simulation Laboratory s (SESL) Chamber A, located at the Johnson Space Center in Houston Texas has recently implemented major enhancements of its cryogenic and vacuum systems. The new liquid nitrogen (LN) thermo-siphon system was successfully commissioned in August of 2012. Chamber A, which has 20 K helium cryo-panels (or shrouds ) which are shielded by 80 K nitrogen shrouds, is capable of simulating a deep space environment necessary to perform ground testing of NASA s James Webb Space Telescope (JWST). Chamber A s previous system used forced flow LN cooling with centrifugal pumps, requiring 220,000 liters of LN to cool-down and consuming 180,000 liters per day of LN in steady operation. The LN system did not have the reliability required to meet the long duration test of the JWST, and the cost estimate provided in the initial approach to NASA-JSC by the subcontractor for refurbishment of the system to meet the reliability goals was prohibitive. At NASA-JSC s request, the JLab Cryogenics Group provided alternative options in 2007, including a thermo-siphon, or natural flow system. This system, eliminated the need for pumps and used one tenth of the original control valves, relief valves, and burst disks. After the thermo-siphon approach was selected, JLab provided technical assistance in the process design, mechanical design, component specification development and commissioning oversight, while the installation and commissioning operations of the system was overseen by the Jacobs Technology/ESC group at JSC. The preliminary commissioning data indicate lower shroud temperatures, 68,000 liters to cool-down and less than 91,000 liters per day consumed in steady operation. All of the performance capabilities have exceeded the design goals. This paper will outline the comparison between the original system and the predicted results of the selected design option, and the commissioning results of thermo-siphon system.

Homan, J.

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY

Characterization of PMR-15 polyimide composition in thermo-oxidatively exposed graphite fiber composites

The contributions of individual resin components to total resin weight loss in 600 F air aged Celion 6000/PMR-15 polyimide composites were determined from the overall resin weight loss in the composite by chemically separating the PMR-15 matrix resin into its monomeric components. The individual resin components were also analyzed by spectroscopic techniques in order to elucidate curing and degradation mechanisms of the PMR-15 matrix resin. The isothermal weight loss of the individual resin components during prolonged 600 F thermo-oxidative aging of the composite was correlated to the changes observed in the Fourier Transform infrared spectra and Fourier Transform nuclear magnetic resonance spectra of the individual resin components. The correlation was used to identify the molecular site of the thermo-oxidative changes in PMR-15 polyimide matrix resin during 600 F curing the prolonged 600 F thermo-oxidative aging.

Alston, W. B.

Application of Thermo-Mechanical Measurements of Plastic Packages for Reliability Evaluation of PEMS

Thermo-mechanical analysis (TMA) is typically employed for measurements of the glass transition temperature (Tg) and coefficients of thermal expansion (CTE) in molding compounds used in plastic encapsulated microcircuits (PEMs). Application of TMA measurements directly to PEMs allows anomalies to be revealed in deformation of packages with temperature, and thus indicates possible reliability concerns related to thermo-mechanical integrity and stability of the devices. In this work, temperature dependencies of package deformation were measured in several types of PEMs that failed environmental stress testing including temperature cycling, highly accelerated stress testing (HAST) in humid environments, and bum-in (BI) testing. Comparison of thermo-mechanical characteristics of packages and molding compounds in the failed parts allowed for explanation of the observed failures. The results indicate that TMA of plastic packages might be used for quality evaluation of PEMs intended for high-reliability applications.

Sharma, Ashok K.

Effect of Water on the Thermo-Mechanical Behavior of Carbon Cloth Phenolic

The results of thermo-mechanical experiments, which were conducted previously by one of the authors, are reviewed. The strain in the direction normal to the fabric plane was measured as a function of temperature for a variety of initial moisture contents and heating rates. In this paper, the general features of the thermo-mechanical response are discussed and the effect of heating rate and initial moisture content are highlighted. The mechanical interaction between the phenolic polymer and water trapped within its free volumes as the polymer is heated to high temperatures is discussed. An equation for the internal stresses which are generated within the polymer due to trapped water is obtained from the total stress expression for a binary mixture of polymer and water. Numerical solutions for moisture diffusion in the thermo-mechanical experiments were performed and the results of these solutions are presented. The results of the moisture diffusion solutions help to explain the effects of heating rate and moisture content on the strain behavior normal to the fabric plane.

Sullivan, Roy M.

Effects of Microstructural Variability on Thermo-Mechanical Properties of a Woven Ceramic Matrix Composite

The objectives of this paper include identifying important architectural parameters that describe the SiC/SiC five-harness satin weave composite and characterizing the statistical distributions and correlations of those parameters from photomicrographs of various cross sections. In addition, realistic artificial cross sections of a 2D representative volume element (RVE) are generated reflecting the variability found in the photomicrographs, which are used to determine the effects of architectural variability on the thermo-mechanical properties. Lastly, preliminary information is obtained on the sensitivity of thermo-mechanical properties to architectural variations. Finite element analysis is used in combination with a response surface and it is shown that the present method is effective in determining the effects of architectural variability on thermo-mechanical properties.

Goldsmith, Marlana B.

Multi-Scale Thermo-Mechanical Modeling of Porous 3D Woven TPS Materials

This work summarizes the process to compute and analyze the thermal conductivity and mechanical properties of 3D woven TPS materials such as 3MDCP (3D Mid-Density Carbon-Phenolic). The PuMA [1,2] software, developed at NASA Ames, was used to characterize different 3MDCP samples from their constituents' data, averaging their thermal conductivity and elastic properties in the three main directions to obtain their effective orthotropic thermo-mechanical properties. This was performed in multiple steps: firstly, TPS samples were digitally reconstructed using micro computed tomography (µCT) and their constituents were segmented; then, the porous matrix phase was analyzed at the micro-scale and these results were used, along with the fibers’ constituents information, to model the tows at the meso-scale; finally, results from the constituents were homogenized and used to model the thermo-mechanical behavior of the unit cell at the macro-scale. Additionally, to gain a better understanding of the tows’ morphology and distribution of the carbon-phenolic blended fibers, microscopy images of the tows’ cross-section were segmented using deep learning techniques and analyzed with PuMA. This workflow can be applied to any TPS material to computationally obtain its thermo-mechanical properties, enabling more informed TPS design and manufacturing choices.

Multi-Scale

Multi-Scale Thermo-Mechanical Modeling of Porous 3D Woven TPS Materials

This work summarizes the process to compute and analyze the thermal conductivity and mechanical properties of 3D woven TPS materials such as 3MDCP (3D Mid-Density Carbon-Phenolic). The PuMA software, developed at NASA Ames, was used to characterize different 3MDCP samples from their constituents' data, averaging their thermal conductivity and elastic properties in the three main directions to obtain their effective orthotropic thermo-mechanical properties. This was performed in multiple steps: firstly, TPS samples were digitally reconstructed using micro computed tomography (µCT) and their constituents were segmented; then, the porous matrix phase was analyzed at the micro-scale and these results were used, along with the fibers’ constituents information, to model the tows at the meso-scale; finally, results from the constituents were homogenized and used to model the thermo-mechanical behavior of the unit cell at the macro-scale. Additionally, to gain a better understanding of the tows’ morphology and distribution of the carbon-phenolic blended fibers, microscopy images of the tows’ cross-section were segmented using deep learning techniques and analyzed with PuMA. This workflow can be applied to any TPS material to computationally obtain its thermo-mechanical properties, enabling more informed TPS design and manufacturing choices.

Multi-Scale

Utah FORGE 5-2615: Determination and Analysis of Thermo-poromechanical Response of Fractured Rock - 2024 Annual Workshop Presentation

This is a presentation on the Determination and Modeling-Informed Analysis of Thermo-poromechanical Response of Fractured Rock for Application to FORGE by the University of Oklahoma, presented by Ahmad Ghassemi. This video presentation discusses how to improve understanding and control of coupled thermoporomechanical (or thermo-hydro-mechanical-THM) processes in reservoir development, and to demonstrate its role in interpretations of the fracture closure pressure. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 13-15, 2024.

15 GEOTHERMAL ENERGY

A First-Principles Study of the Structural and Thermo-Mechanical Properties of Tungsten-Based Plasma-Facing Materials

Tungsten (W) and tungsten alloys are being considered as leading candidates for structural and functional materials in future fusion energy devices. The most attractive properties of tungsten for the design of magnetic and inertial fusion energy reactors are its high melting point, high thermal conductivity, low sputtering yield, and low long-term disposal radioactive footprint. Despite these relevant features, there is a lack of understanding of how the structural and mechanical properties of W-based alloys are affected by the temperature in fusion power plants. In this work, we present a study on the thermo-mechanical properties of five W-based plasma-facing materials. First-principles density functional theory (DFT) calculations are combined with the quasi-harmonic approximation (QHA) theory to investigate the electronic, structural, mechanical, and thermal properties of these W-based alloys as a function of temperature. The coefficient of thermal expansion, temperature-dependent elastic constants, and several elastic parameters, including bulk and Young’s modulus, are calculated. Our work advances the understanding of the structural and thermo-mechanical behavior of W-based materials, thus providing insights into the design and selection of candidate plasma-facing materials in fusion energy devices.

42 ENGINEERING

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

silicone intumescence

Development, validation, and verification of multi-pass thermo-mechanical welding simulations using the open-source MOOSE framework: NeT TG4 benchmark weldment

This study develops and validates a sequentially coupled thermo-mechanical welding simulation for the three-pass 316L stainless steel NeT TG4 benchmark weldment using the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) and the Nuclear Engineering Material model Library (NEML). A diffused ellipsoidal heat source was calibrated against thermocouple data and weld macrographs to accurately model the fusion zone geometry and transient thermal fields. Material hardening is represented using the Lemaitre-Chaboche mixed isotropic-kinematic hardening model, while four annealing models - no annealing, single-stage at 1050 °C and 1300 °C, and two-stage at 800 °C/1300 °C - were implemented to assess the impact of annealing models on the accuracy of the predicted welding-induced plasticity, distortions, and residual stresses. The predictions were validated against experimental measurements and benchmarked against results from commercial software, demonstrating that thermo-mechanical MOOSE welding simulations achieve comparable accuracy with enhanced computational efficiency. This work highlights the potential of using open-source finite element frameworks like MOOSE for advanced manufacturing simulations.

Ji, Wendy [Australian Nuclear Science and Technolo

Investigation of residual stress distribution in wire-arc directed energy deposited refractory molybdenum alloy utilizing numerical thermo-mechanical analysis and neutron diffraction method

Directed energy deposition (DED), a metal additive manufacturing (AM) technique, offers higher deposition rates and energy efficiency, making it suitable for fabricating components from refractory molybdenum alloys, such as molybdenum-titanium-zirconium (TZM). However, large thermal gradients and non-equilibrium thermal cycles in DED could generate high residual stress in the component, potentially deteriorating quality and performance. Thus, this study aims to investigate residual stress generation and its distribution in wire-arc DED of TZM thin-wall, utilizing thermo-mechanical analysis and high-fidelity neutron diffraction (ND) method. Two interpass temperatures (50°C and 200°C) have been considered to investigate their impact on residual stress formation. During experiments, in-situ thermal data has been recorded using thermocouples, which have been utilized for calibrating the thermal model. Thermocouple data shows a good agreement with the simulation results, having a difference of less than 10 %. Post-deposition part deformation has been observed, which is measured using a coordinate measuring machine, showing maximum values of 0.93 mm and 0.78 mm for interpass temperatures of 50°C and 200°C, respectively. Numerical predictions of distortion deviated by less than 15% from the experimental results. ND measurement and simulation results indicate that residual stress magnitude and evolution vary across the TZM deposits, revealing microstructural anisotropy in both conditions. Notably, lower interpass temperatures resulted in higher residual stresses, confirmed by experimental and simulation data. Further, this study demonstrated that an integrated experimental and thermo-mechanical analysis can potentially reveal the temperature history, part deformation, and residual stress formation in wire-arc DED TZM alloy.

36 MATERIALS SCIENCE