Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermocouples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High Temperature Irradiation Resistant Thermocouple Drift Model Application to Commercial Thermocouples

The Advance Sensors and Instrumentation fiscal year report on the direct application of the HTIR-TC drift model on other commercial thermocouples. The Type N and K thermocouples are useful in irradiation environments up to 1100°C (or 1290°C for short bursts and/or single use), but over temperature and high fluence can cause the TCs to drift. The HTIR-TC drift model predicts the end use environment of temperature and irradiation and the total time scale to show the amount of drift a thermocouple will undergo. The model predicts that HTIR-TCs at full temperature range and fluence of 10^21 N/cm^2 will exhibit a drift of under -1%. The type N and K TCs will see a drift of -0.5% at the same fluence, but temperatures below 1100°C. Above this temperature the Type N and K TCs quickly de-calibrate and will give erroneous temperatures measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-temperature, irradiation-resistant thermocouple, coaxial thermocouple, and related methods

A coaxial thermocouple includes a wire, an insulation layer surrounding the wire, a sheath surrounding the insulation layer, and an electrical junction formed between the wire and the sheath and at one longitudinal end of the coaxial thermocouple, the electrical junction including a swaged end with an outer diameter of the sheath reducing in diameter along a longitudinal length of the coaxial thermocouple until the sheath contacts the wire within the insulation layer. The wire includes a first material and the sheath includes a second material where the first material includes one of molybdenum (Mo) or niobium (Nb) and the second material includes the other of molybdenum (Mo) or niobium (Nb).

Skifton, Richard S.↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of Thermocouple Performance in the Advanced Gas Reactor Experiment AGR-5/6/7 During Irradiation in the Advanced Test Reactor

The Advanced Gas Reactor -5/6/7 (AGR-5/6/7) experiment was the fourth and final experiment in the AGR experiment series and completed irradiation in July 2020. It serves as the formal fuel qualification test for the TRISO fuels under development by the US Department of Energy. This experiment was designed to irradiate fuel particles at temperatures ranging from 800°C ? 1500°C. The high end of the range created unique challenges for thermocouple-based temperature measurements. Commercially available high-temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C) suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. A special low neutron cross-section thermocouple system based on molybdenum/niobium thermoelements called High Temperature Irradiation Resistant thermocouple (HTIR-TC) has been under development at INL since circa 2004. Several examples of this thermocouple type were incorporated into regions of the test operating above 1200°C. For regions in the test operating in the 1000°C ? 1200°C range, high-performance versions of Type N thermocouples recently developed at Cambridge University were installed. Standard Type N thermocouples were used in regions of the test operating below 1000°C. A total of 54 thermocouples were incorporated into the test. A report of the performance of this large heterogenous set of thermocouples over the first third of the irradiation was previously provided (ANIMMA 2019). This follow-on paper discusses results from the balance of the experiment (Feb 2019 - July 2020). Special attention is focused on potential drift of thermocouples operating in the higher temperature regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of Thermocouple Performance in the Advanced Gas Reactor Experiment AGR-5/6/7 During Irradiation in the Advanced Test Reactor

This is a conference presentation ppt file. The following abstract is for the entire conference paper - which will later be the subject of a PRS artifact The Advanced Gas Reactor -5/6/7 (AGR-5/6/7) experiment was the fourth and final experiment in the AGR experiment series and completed irradiation in July 2020. It serves as the formal fuel qualification test for the TRISO fuels under development by the US Department of Energy. This experiment was designed to irradiate fuel particles at temperatures ranging from 800°C ? 1500°C. The high end of the range created unique challenges for thermocouple-based temperature measurements. Commercially available high-temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C) suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. A special low neutron cross-section thermocouple system based on molybdenum/niobium thermoelements called High Temperature Irradiation Resistant thermocouple (HTIR-TC) has been under development at INL since circa 2004. Several examples of this thermocouple type were incorporated into regions of the test operating above 1200°C. For regions in the test operating in the 1000°C ? 1200°C range, high-performance versions of Type N thermocouples recently developed at Cambridge University were installed. Standard Type N thermocouples were used in regions of the test operating below 1000°C. A total of 54 thermocouples were incorporated into the test. A report of the performance of this large heterogenous set of thermocouples over the first third of the irradiation was previously provided (ANIMMA 2019). This follow-on paper discusses results from the balance of the experiment (Feb 2019 - July 2020). Special attention is focused on potential drift of thermocouples operating in the higher temperature regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Test Results of Thermocouples Used in the TRISO-Fuel Irradiation Experiment AGR-5/6/7

High-temperature gas reactor irradiation experiments create unique challenges for thermocouple-based temperature measurements. High-temperature industrial thermocouples suffer rapid decalibration due to transmutation of the thermoelements from neutron absorption. For lower-temperature applications, Type K and Type N thermocouples are affected by neutron irradiation only to a limited extent. But until recently, the use of these nickel-based thermocouples was limited when the temperature exceeded 1050°C due to drift related to phenomena other than nuclear irradiation. Certain portions of the AGR-5/6/7 experiment experienced temperatures higher than any of the previous AGR tests, up to 1500°C. Recognizing the limitations of existing thermometry to measure such high temperatures, the sponsor of the AGR-5/6/7 test supported a development and testing program for thermocouples capable of low-drift operation at temperatures above 1100°C. This program included additional development of high-temperature irradiation-resistant thermocouples based on molybdenum/niobium thermoelements, which have been studied at Idaho National Laboratory since circa 2004. A step change in accuracy and long-term stability of this thermocouple type was achieved as part of the AGR-5/6/7 thermometry development program. Additionally, long-term testing (7000+ h) at 1250°C of Type N thermocouples utilizing a customized sheath developed at the University of Cambridge has been completed with excellent low-drift results. The results of this testing as well as testing of the improved high-temperature irradiation-resistant design are reported herein. Both the improved high-temperature irradiation-resistant and the Cambridge Type N thermocouple types were incorporated into the AGR-5/6/7 test, which began irradiation in February 2018 and was completed in July 2020. Finally, a summary of the performance of the thermocouples incorporated into the AGR-5/6/7 test is included herein.

In-pile instrumentation↗

Non-intrusive temperature measurements in the vicinity of a thermocouple using synchrotron x-ray fluorescence

A highly spatially resolved synchrotron x-ray fluorescence (XRF) thermometry technique has been used to map temperature fields around a 125 mu m type R thermocouple immersed in a stoichiometric premixed methane flame. The high spatial resolution of the XRF technique allowed temperatures to be measured close to the thermocouple and the impact of the thermocouple on the flame to be assessed. This paper discusses some of the nontrivial challenges of these measurements including the recovery of spectral features from the krypton fluorescent agent that are overlapped by those from the thermocouple metals at locations near the bead surface. The calculated temperatures from 1D premixed flame simulations are in excellent agreement with measurements along the centerline. The results show that the 125 mu m thermocouple induces minimal disturbances to the gas flow and any catalytic effects originating from the bare wires are also inconsequential. Here, the methodology has advanced to a stage where it enables comparisons between the gas temperature in the vicinity of the thermocouple and the actual thermocouple reading.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

Advanced Multiphysics Code Coupling for Cladding Surface Thermocouples During Two-Phase Heat Transfer from Nuclear Fuel

Transient testing of nuclear fuel involves the evaluation of fuel performance under off-normal and accident conditions and is essential for proving design performance. Instrumentation included in such experiments commonly includes thermocouples attached to the outer surface of the cladding to provide temperature measurements throughout the transient. However, the presence of thermocouples on the cladding surface can alter the local heat transfer characteristics with the surrounding coolant. These localized effects can influence the temperature of the nearby cladding surface and introduce uncertainties in interpreting the thermocouple data. Understanding the impact of thermocouples attached to the outer surface of the cladding is crucial for accurate data interpretation as well as its effect on the thermomechanical behavior of the cladding. This paper presents a novel methodology for simulating the impact of outer cladding thermocouples during transient testing of nuclear fuels. The simulation framework leverages the thermal-hydraulic capabilities of RELAP5-3D coupled to the BISON fuel performance code through the RELAPCouplingApp interface. The methodology is compared against Accident Tolerant Fuel Reactivity Initiated Accident-1-E experiment performed at Idaho National Laboratory. The results reveal approximately 100°C difference between thermocouple-altered temperature and virgin cladding surface. The model overpredicts surface rewet time due to conservative correlations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Boride-based Ceramic Super-high Temperature Thermocouples in Harsh Environments (Final Scientific/Technical Report)

An electromotive force (emf) can be generated along a temperature gradient between the cold end and hot end of a thermoelectric material, termed the Seebeck effect. Based on the Seebeck effect, metallic alloys have been extensively employed to detect temperatures for centuries, named thermocouples. However, commercially available thermocouple alloys suffer from limitations, such as oxidation, chemical degradation, and poor long-term stability under high-temperature harsh environments. This DOE-funded project aimed to develop high-temperature, chemically tolerant thermocouples suitable for operation in extreme environments relevant to semiconducting thermoelectric materials. The research focused on boride-based semiconducting thermoelectric compounds as candidates for next-generation thermocouples with enhanced oxidation resistance, chemical stability, and thermal robustness under conditions representative of charcoal-fired electricity facilities. During the funded years, boride materials were synthesized using an arc-plasma technique under ambient air and argon atmospheres, enabling scalable and cost-effective production compared with conventional boride fabrication methods. The synthesized borides were processed into nanostructured powders, followed by consolidation into dense bulk materials using a spark plasma sintering (SPS) bottom-up approach. Comprehensive characterization was performed, including microstructural analysis, electrical transport measurements, and optical and thermal property evaluation. Both p-type and n-type boride electric legs were fabricated and integrated into boride-based thermocouples. The thermal and irradiation stabilities of the boride nanomaterials and bulk thermoelectric materials were systematically evaluated to assess suitability for long-term operation in harsh environments. Additionally, 12 students were broadly hands-on trained spanning the full research workflow, including word processing and technical editing (e.g., LATEX for manuscript and poster preparation), data collection and analysis (using Python and related libraries and hardware interfaces), sample preparation (including arc-plasma synthesis and spark plasma sintering), and advanced characterization techniques (such as X-ray diffraction, UV–vis spectroscopy, electron microscopy, differential thermal analysis (DTA), and Seebeck coefficient measurements, etc). Overall, this project demonstrated the feasibility of boride-based thermoelectric materials as durable high-temperature thermocouples, providing a promising pathway toward robust temperature sensing technologies aligned with DOE energy infrastructure and extreme-environment monitoring needs.

20 FOSSIL-FUELED POWER PLANTS↗

Sensitivity study on the fin effect of thermocouple mounted on the heated surface under film boiling condition

In the reactivity-initiated accident (RIA) scenario, right after the power burst with the occurrence of departure from nucleate boiling (DNB), the cladding temperature quickly reaches its maximum and is maintained in a steady film boiling regime. Then, under limited heat transfer performance of film boiling, the local cooling effect by the thermocouple wire may not be neglected. A computational model is developed to estimate the local cooling effect of the thermocouple wire mounted on the cladding surface under film boiling condition. The model predicts the temperature profile along the cladding surface as physically expected and is verified against the benchmark problem. Sensitivity studies reveal the significant effects of the thickness of vapor film layer and the diameter of thermocouple on the temperature drop near the thermocouple, for they increase the heat transfer area to the liquid water region. The impact of film boiling heat transfer coefficient, however, is not significant, as the primary heat transfer mechanism near the thermocouple is the heat conduction to the wire. Future study will include the contribution of radiative heat transfer between the cladding surface and the vapor film layer, as well as a transient power history which represents an actual RIA scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Embedding thermocouples in SS316 with laser powder bed fusion

Recent advances in manufacturing technologies have enabled the fabrication of complex geometries for a wide range of applications, including the energy, aerospace, and civil sectors. The ability to integrate sensors at critical locations within these complex components during the manufacturing process could benefit process monitoring and control by reducing reliance on models to relate surface measurements to internal phenomena. This study investigated embedding thermocouples in a SS316 matrix using laser powder bed fusion. Under optimal processing conditions, embedded thermocouples were characterized post-building, finding good bonding to the matrix with no melt pool penetration to the sensing elements. Futher, the embedded thermocouple performed similarly to an identical non-embedded thermocouple during thermal testing to 500 °C with only a slight difference in response time, which was attributed to the differences in mass and the associated thermal time constants.

image analysis↗

Thermocouple assembly

Disclosed is a thermocouple assembly having a resilient mount; a buffer having a first side and a second side, with the buffer first side connecting with the resilient mount; an insulator having a first side and a second side, with the insulator first side connecting with the buffer second side; and a thermocouple having a first side and a second side, the thermocouple first side connecting with the insulator second side, and the thermocouple second side being configured to be in thermal contact with an object to be measured.

Schwarting, Nelson↗

In situ embedment of type K sheathed thermocouples with directed energy deposition

Advanced nuclear reactor systems require new technologies for heat transfer and system monitoring. Additive manufacturing (AM) offers the design flexibility to allow in-situ sensor embedment through smart manufacturing for real-time monitoring, and performance of these systems. Here, this study focuses on experiments investigating the feasibility of in-situ sensor embedment using directed energy deposition (DED). Type K thermocouples are embedded into 316L stainless steel (SS) samples using two different configurations (e.g., exposed and embedded tips) and two designs (e.g., flush to substrate) within an AM base. Embedded sensor samples are analyzed via in-situ measurements and high-temperature performance validation tests at 350ºC and 900ºC. Temperature performance results at both temperature tests show good agreement with manufacturer specifications proving that these sensors could still capture accurate temperature readings after in-situ embedment during DED processing. An additional optimization experiment was conducted on the exposed tip configuration using a surrogate thermocouple to improve tolerances and the embedment process. Results improved tolerances, lower porosity, smaller gaps between the sensor and base, and better junction contact for the sensor. Although further optimization of this embedment strategy is necessary to improve the structural stability and tolerances within the component, this research strategy provides a proof-of-feasibility for DED embedment with commercial sheathed thermocouples. This research provides early impact on embedment of sensor for multiple materials and complex geometric components..

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Design and Implementation of Surface Eroding Thermocouples for Stage-One Modular Divertor Integration at the DIII-D Tokamak

The DIII-D has upgraded its upper divertor to a modular system using copper alloy pedestals to alter the divertor geometry without changing the vessel structure. Six new graphite tiles were designed for the shape and volume rise (SVR) divertor. Here, these new SVR tiles facilitated the formation of a poloidal array of 27 surface eroding thermocouples (SETCs) in the upper divertor region. At one location, a specialized recessed SETC, paired with a standard flush SETC, was installed in one of the ceiling tiles to provide comprehensive heat flux measurements, distinguishing between charged and noncharged particle contributions. Upgrades were made to the SETC system in the small-angle slot (SAS) divertor to improve overall performance. These upgrades included optimizing the feedthrough system to double the thermocouple cable capacity and reallocating cables from the SAS area to the SVR divertor. A compact isolation amplifier system with a fixed gain of 41 was employed to improve the signal level and minimize interference. Additionally, two analog-to-analog fiber systems were implemented for transmitting thermocouple signals over a single fiber, significantly reducing both noise levels and costs. The newly installed SETCs in the SVR divertor successfully completed initial commissioning testing. The SETCs captured the in-out asymmetry in the power distribution between the inner and outer strike points and demonstrated the dependency of the heat flux profile on the outer strike point location. During divertor detachment, heat flux mitigation was noted at the outer strike point location, while significant heat flux contributions from neutral particles were measured in the SVR divertor.

Divertor↗

Multi-core high-temperature, irradiation-resistant thermocouple, and related methods

A multi-core thermocouple includes a plurality of wires, an insulation core surrounding the plurality of wires, a sheath surrounding the insulation core, and a plurality of electrical junctions. The plurality of electrical junctions may include a first electrical junction formed between a first wire of the plurality of wires and the sheath at a first axial mid-section of the multi-core thermocouple, the first electrical junction including a first swaged axial mid-section of the sheath and a second electrical junction formed between a second wire of the plurality of wires and the sheath at a second, different axial mid-section of the multi-core thermocouple, the second electrical junction including a second swaged axial mid-section of the sheath.

Skifton, Richard S.↗

Function and Operational Requirements for High-Temperature Irradiation-Resistant Thermocouples

The function and operation requirements for the high-temperature irradiation-resistant thermocouple (HTIR-TC) are set forth. A mission and product are proposed. The function and operational requirements involve temperature range, accuracy, drift, life, mechanical ruggedness, and response time. Each have a criterion set to establish a thermocouple that can withstand a typical 18-month nuclear power plant refueling cycle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗