Search NASASearch

SEARCH · Search NASA

Results for “thermometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SnSe 2 thermal conductivity from optothermal Raman and Stokes/anti-Stokes thermometry

The optothermal Raman method is useful in determining the in-plane thermal conductivity of two-dimensional (2D) materials that are either suspended or supported on a substrate. We compare this method with the Stokes/anti-Stokes scattering thermometry method, which can play a role in both calibration of Raman peak positions as well as extraction of the local phonon temperature. This work demonstrates that the Stokes/anti-Stokes intensity ratio plays an important role in determining the in-plane thermal conductivity of 2D tin diselenide (SnSe 2 ) dry-transferred onto a polished copper (Cu) substrate. The statistically-averaged thermal conductivity of the 108 ± 24 nm-thick SnSe 2 yielded 5.4 ± 3.5 Wm −1 K −1 for the optothermal Raman method, and 2.40 ± 0.81 Wm −1 K −1 for the Stokes/anti-Stokes thermometry method, indicating that the Stokes/anti-Stokes thermometry method to calculate the thermal conductivity of a material can simultaneously increase both precision and accuracy. The uncertainty value was also lowered by a factor of 1.9 from the traditional optothermal Raman method to the Stokes/anti-Stokes thermometry method. The low in-plane thermal conductivity of 2D SnSe 2 , 1.3–2.9 times lower than bulk, is useful for applications in thermal and electrical energy conversion and thermoelectric devices.

2D materials

Nonseeded linewise temperature measurements by resonantly ionized photoemission thermometry in a Mach 4 Ludwieg tube

A one-dimensional (1D) thermometry using oxygen-tagging resonantly ionized photoelectron thermometry (O 2 RIPT) was employed to investigate thermal gradients within a Mach 4 Ludwieg tube. The Ludwieg tube is pulsed with a test duration of approximately 100 ms, providing a cold supersonic flow at Mach 4 ideal for studying aerothermal effects. This study focused on measuring freestream temperatures, capturing shock-induced heating behind a detached bow shock from a blunt cylinder, and resolving sharp temperature variations across a bow shock generated by a cylinder. The O 2 RIPT technique produced strong emission signals extending approximately 4 cm long, demonstrating its capability for precise temperature measurements in high-speed wind tunnel environments. The results confirm that O 2 RIPT is well-suited for applications in large-scale aerodynamic testing facilities, particularly in regions with strong compression effects, enabling the resolution of sharp thermal gradients. This method presents a promising solution for thermometry in dynamic flow conditions relevant to various experimental ground-test facilities.

McCord, Walker (ORCID:0000000179747550)

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]

Single-Shot Rotational Raman Thermometry for Turbulent Flames Using a Low-Resolution Bandwidth Technique

An alternative optical thermometry technique that utilizes the low-resolution (order 10(exp 1)/cm) pure-rotational spontaneous Raman scattering of air is developed to aid single-shot multiscalar measurements in turbulent combustion studies. Temperature measurements are realized by correlating the measured envelope bandwidth of the pure-rotational manifold of the N2/O2 spectrum with a theoretical prediction of a species-weighted bandwidth. By coupling this thermometry technique with conventional vibrational Raman scattering for species determination, we demonstrate quantitative spatially resolved, single-shot measurements of the temperature and fuel/oxidizer concentrations in a high-pressure turbulent Cf4-air flame. Our technique provides not only an effective means of validating other temperature measurement methods, but also serves as a secondary thermometry technique in cases where the anti-Stokes vibrational N2 Raman signals are too low for a conventional vibrational temperature analysis.

Kojima, Jun

Understanding Radiation Thermometry

This document is a two-part course on the theory and practice of radiation thermometry. Radiation thermometry is the technique for determining the temperature of a surface or a volume by measuring the electromagnetic radiation it emits. This course covers the theory and practice of radiative thermometry and emphasizes the modern application of the field using commercially available electronic detectors and optical components. The course covers the historical development of the field, the fundamental physics of radiative surfaces, along with modern measurement methods and equipment.

Risch Timothy K.

Understanding Radiation Thermometry

This document is a two-part course on the theory and practice of radiation thermometry. Radiation thermometry is the technique for determining the temperature of a surface or a volume by measuring the electromagnetic radiation it emits. This course covers the theory and practice of radiative thermometry and emphasizes the modern application of the field using commercially available electronic detectors and optical components. The course covers the historical development of the field, the fundamental physics of radiative surfaces, along with modern measurement methods and equipment.

Risch, Timothy K.

Nitric Oxide Laser-Induced Fluorescence Rotational Thermometry in a Hypersonic Non-Equilibrium Flow

Spatially-resolved nitric oxide (NO) planar laser-induced fluorescence (PLIF) rotational thermometry was performed on a Mach 5 non-equilibrium flow around a blunt-body specimen in the Hypersonic Materials Environmental Test System (HyMETS) arc-heat wind tunnel at the NASA Langley Research Center. Transitions within the (0,0) band in the A(exp⁡ 2)∑(sup⁡ +) - X(exp⁡ 2)Π system of NO were excited with a 10 Hz pulsed ultra-violet laser. A multi-line fitting algorithm was applied to the PLIF spectra and transitions were filtered based on an iterative method that maximizes thermometry accuracy. NO PLIF thermometry results are compared to non-equilibrium computational fluid dynamics (CFD) simulations reported in the literature. Differences between the experiment and CFD are quantified for the free-stream, post-shock, shear-layer, and expansion-fan regions of the flow. Potential sources of error, applicable to both the CFD and experiment, are discussed.

Connor C McDougall

Temperature Mapping of Air Film-Cooled Thermal Barrier Coated Surfaces Using Phosphor Thermometry

While the effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness for jet engine components are usually studied separately, their contributions to combined cooling effectiveness are interdependent and are not simply additive. Therefore, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. Phosphor thermometry offers several advantages for mapping temperatures of air film cooled surfaces. While infrared thermography has been typically applied to study air film cooling effectiveness, temperature accuracy depends on knowing surface emissivity (which may change) and correcting for effects of reflected radiation. Because decay time-based full-field phosphor thermometry is relatively immune to these effects, it can be applied advantageously to temperature mapping of air film-cooled TBC-coated surfaces. In this presentation, an overview will be given of efforts at NASA Glenn Research Center to perform temperature mapping of air film-cooled TBC-coated surfaces in a burner rig test environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and the strengths and limitations of this method for studying air film cooling effectiveness are discussed.

air film cooling

10-kHz PLIF Thermometry for a Turbulent Jet Flame using Single Burst-mode OPO

Two-color Planar laser-induced fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to285.62 nm and 285.67 nm to excite the Q2(12) and P1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.

thermometry

10-kHz PLIF Thermometry for Turbulent Jet Flame using Single Burst-mode OPO

Two-color Planar Laser-Induced Fluorescence (TC-PLIF) thermometry techniques that employ two laser systems and two cameras face challenges when implemented in practical combustion facilities because of experimental complexity and multiple laser and camera requirements, particularly for high-speed TC-PLIF. To circumvent those problems, we developed a fast, dual-wavelength switching, burst-mode OPO technology to significantly reduce the experimental complexity of high-speed TC-PLIF thermometry and simplify its implementation in harsh combustion and flow test facilities. A fast, dual-wavelength switched seed laser enabled a high-energy, high-repetition-rate burst-mode laser to generate two 10-kHz pulse trains at wavelengths of ~354.8 nm. The injection-seeded OPO efficiently converts the burst-mode laser output to 285.62 nm and 285.67 nm to excite the Q2(12) andP1(8) OH transitions. PLIF images were collected from each of the two excitation transitions with a single camera and an UV intensifier, and intensity ratios from the images were used to determine local temperatures. Ten kHz hydroxyl radical (OH) TC-PLIF for premixedCH4/Air/H2 jet flame was demonstrated.

thermometry

Solid-state thermometry via ionic–electronic coupling in two-dimensional heterostructures

The coupling of ionic and electronic transport in solid-state systems offers new opportunities for realizing compact, energy-efficient sensing technologies, yet practical implementations remain limited. In this article, we introduce a two-dimensional iontronic platform based on field-effect transistors that integrate monolayer MoS 2 channels with van der Waals bimetallic thiophosphates ( AB P 2 X 6 , A = Li, Cu, Ag and so on; B = In, Sc and so on; and X = S and Se) as ionic gate dielectrics to realize on-chip thermometry. Specifically, we exploit thermally activated ion migration within the gate dielectric leading to conductance modulation in the MoS 2 channel for temperature sensing. We achieve ~1–2 °C resolution, fast electronic readout and subpicojoule energy consumption in an ultracompact footprint (~1 µm 2 ). Beyond thermometry, these results establish bimetallic thiophosphates as a versatile platform for solid-state iontronics and broaden the functional design space of van der Waals heterostructures for sensing, actuation and adaptive electronics.

42 ENGINEERING

Validation of 266 nm UV Raman thermometry using the alpha-to-beta quartz transition

Ultraviolet Raman scattering is a promising diagnostic for temperature measurements relevant to dynamic compression experiments, where improved signal strength and reduced background are critical. In this work, we experimentally validate Raman thermometry at 266 nm using crystalline quartz heated through the α to β phase transition in a tube furnace. Quartz provides a useful benchmark because of its well-characterized transition temperature near 846 K at ambient pressure. Temperatures inferred from the Stokes to anti-Stokes intensity ratio are compared with thermocouple measurements and with the observed phase transition. Single-shot Raman temperatures track the thermocouple closely, with an empirical single-shot scatter of approximately ±15 K under the present conditions. Temporal averaging reduces shot-to-shot scatter and improves agreement between the Raman temperatures and thermocouple readings to within approximately 8 K, while the transition is identified within 5 K of the accepted value. Measurements are performed using the fourth harmonic of a nanosecond pulsed Nd:YAG laser at 266 nm. The shorter excitation wavelength provides enhanced Raman scattering efficiency and reduced visible background relative to conventional visible excitation. Comparison with 532 nm Raman measurements acquired in the same experimental geometry demonstrates substantially improved signal-to-noise ratio for the UV configuration. These results establish 266 nm Raman thermometry as a reliable and accurate temperature diagnostic under controlled heating conditions and provide a quantitative benchmark for future application in dynamic compression and shock physics experiments.

Chemistry - Chemical explosives

Coherence-mediated quantum thermometry in a hybrid circuit quantum electrodynamics architecture

Quantum thermometry plays a critical role in the development of low-temperature sensors and quantum information platforms. Here, in this work, we propose and analyze a hybrid circuit quantum electrodynamics architecture in which a superconducting qubit is dispersively coupled to two distinct bosonic modes: one initialized in a weak coherent state as a phase reference and information buffer and the other coupled to a thermal environment. We show that the qubit serves as a sensitive readout of the probe mode, mapping the interplay between thermal and coherent photon-number fluctuations onto measurable dephasing. This coherence-mediated mechanism enables improved sensitivity to thermal energy fluctuations in the sub-millikelvin regime through Ramsey interferometry. We derive analytic expressions for the probe coherence envelope, compute the quantum Fisher information for temperature estimation, and demonstrate numerically that the presence of a coherent reference enhances the qubit's sensitivity to small changes in thermal photon occupancy. Our results establish a coherence-enabled approach to thermometry and provide a scalable platform for future calorimetric sensing in high-energy physics and quantum metrology.

Zhu, Shaojiang [Fermi National Accelerator Laborat

Dual-mode fiber-optic refractive-index gas thermometry with primary anchoring and continuous temperature tracking

Extending fiber-optic refractive-index gas thermometry beyond primary-only operation, we report a dual-mode argon-filled Fabry-Perot thermometer in which the same cavity first establishes a primary temperature anchor and then performs continuous secondary-mode tracking. The primary anchor is obtained from two-pressure fringe shifts using a virial-coefficient refractivity model. During secondary operation, pressure cycling is stopped, and temperature is recovered from the monitored fringe wavelength and gas pressure using a model that includes argon refractivity, pressure-induced cavity strain, and fused-silica thermal expansion. From 310 to 1013 K, secondary-mode temperatures agreed with a reference thermocouple with 0.21 K RMSE and 0.47 K maximum error; 45-min natural furnace cooldowns were also tracked from nearby anchors with close agreement. The dual-mode method retains the empirical-calibration-free primary measurement as an in-situ reference while enabling simpler continuous tracking between anchors, addressing a practical limitation of primary-only fiberoptic refractive-index gas thermometry for hightemperature applications.

Syed, Musaddeque [Michigan State University, East

Measurement of Two-Phase Flow and Heat Transfer Parameters using Infrared Thermometry

A novel technique to measure heat transfer and liquid film thickness distributions over relatively large areas for two-phase flow and heat transfer phenomena using infrared (IR)thermometry is described. IR thermometry is an established technology that can be used to measure temperatures when optical access to the surface is available in the wavelengths of interest. In this work, a midwave IR camera (3.6-5.1 microns) is used to determine the temperature distribution within a multilayer consisting of a silicon substrate coated with a thin insulator. Since silicon is largely transparent to IR radiation, the temperature of the inner and outer walls of the multilayer can be measured by coating selected areas with a thin, IR opaque film. If the fluid used is also partially transparent to IR, the flow can be visualized and the liquid film thickness can be measured. The theoretical basis for the technique is given along with a description of the test apparatus and data reduction procedure. The technique is demonstrated by determining the heat transfer coefficient distributions produced by droplet evaporation and flow boiling heat transfer.

Kim, Tae-Hoon

In Situ Atmospheric Plume Thermometry via Carbon Monoxide Spectral Profile: Laboratory and Field Validation

For small molecules with large rotational constants, knowing the relative intensities of the ro-vibrational transitions can be used to determine the temperature within a gas plume. We demonstrate the use of carbon monoxide (CO) as an in situ spectroscopic probe of gas plume temperature by application of both laboratory and standoff Fourier transform infrared spectroscopy to monitor the CO spectral response at different temperatures. Here, the measured CO rotational contours were analyzed using a simple Boltzmann model to deduce the population distribution of the J-levels, from which the in-plume temperature is deduced. The method was vetted by comparing deduced temperatures in both static laboratory measurements of known temperatures, as well as field measurements using a simulated smokestack release. For the smokestack experiments, spectroscopically deduced temperatures were compared to readings from a series of thermocouples placed at strategically sampled distances along the plume trajectory. Both the spectroscopically-derived and thermocouple-measured temperatures revealed an expansion-induced (mixing) rapid cooling of the plume, with the infrared thermometry values displaying greater temperature values which are believed to better represent the actual plume temperatures.

Analysis of rotational structure

Characterization and thermometry of dissipatively stabilized steady states

In this work we study the properties of dissipatively stabilized steady states of noisy quantum algorithms, exploring the extent to which they can be well approximated as thermal distributions, and proposing methods to extract the effective temperature T. We study an algorithm called the relaxational quantum eigensolver (RQE), which is one of a family of algorithms that attempt to find ground states and balance error in noisy quantum devices. In RQE, we weakly couple a second register of auxiliary ‘shadow’ qubits to the primary system in Trotterized evolution, thus engineering an approximate zero-temperature bath by periodically resetting the auxiliary qubits during the algorithm’s runtime. Balancing the infinite temperature bath of random gate error, RQE returns states with an average energy equal to a constant fraction of the ground state. We probe the steady states of this algorithm for a range of base error rates, using several methods for estimating both T and deviations from thermal behavior. In particular, we both confirm that the steady states of these systems are often well-approximated by thermal distributions, and show that the same resources used for cooling can be adopted for thermometry, yielding a fairly reliable measure of the temperature. These methods could be readily implemented in near-term quantum hardware, and for stabilizing and probing Hamiltonians where simulating approximate thermal states is hard for classical computers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC