Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermostatically controlled load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Local Communication in Populations of Thermostatically Controlled Loads

Thermostatically controlled loads (TCLs) have shown great potential for demand response (DR) in electric grid operations. However, it has been commonly seen that DR events using TCLs may cause load synchronization and unwanted oscillatory effects, especially in homogeneous populations. In an attempt to mitigate the negative impacts of DR events, a decentralized method is proposed that modifies each thermostat behavior based on the activity of a small number of nearby TCLs. This feedback introduces the possibility of instability in the aggregate behavior. A stability analysis is performed on a linearized model of the aggregate system and the results of that analysis compared to simulation results. The proposed modification of thermostat behavior results in fourfold reduction in the post-DR peak while suppressing ensuing oscillations at the expense of a modest increase in compressor cycling. Further, the linearized model also provides insight into the aggregate behavior of the population.

24 POWER TRANSMISSION AND DISTRIBUTION↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

Evaluation of Equivalent Battery Model Representations for Thermostatically Controlled Loads in Commercial Buildings

Models for thermostatically controlled loads in commercial buildings often include many parameters and variables compared to residential buildings. As such, it is beneficial to use reduced-order models to represent these resources. A classic example of such a model is the Virtual Battery or Equivalent Battery Model (EBM). In this paper, the typical EBM is extended to higher-order commercial Heating, Ventilation, and Air-conditioning (HVAC) models and adapted for electric water heaters. Finally, we compare the performance of EBMs with detailed thermal models using three classic optimization problems - energy maximization, energy minimization, and power reference tracking. Our results show that the EBM-constrained and detailed thermal model-constrained problems produce similar outcomes in terms of temperature, power, and total energy consumption.

commercial buildings↗

Flexibility Estimation and Control of Thermostatically Controlled Loads with Lock Time for Regulation Service

A virtual battery model is a simple and general method to quantify aggregate flexibility from thermostatically controlled loads (TCLs), enabling grid operators to effectively coordinate a large number of flexible building loads with supplyside resources in power systems. Lockout controls are designed to avoid wear and tear resulting from short-cycling of hardware. The lock on/off time could significantly affect aggregate flexibility from TCLs to provide ancillary services and may even fail control algorithms designed without considering the lock time constraints. This paper focuses on flexibility estimation and control design for TCLs with lock time constraints to provide frequency regulation service. We first investigate the potential impacts of lock time on TCLs’ aggregate flexibility and control performance. Both control-dependent and control-independent power bounds are derived, based on either previous TCL switching operations or regulation signals. While the control-dependent method provides aggregate flexibility for a given control method, the control-independent method calculates the theoretical maximum of power bounds. Two control algorithms are proposed to better distribute flexibility over time and thereby improve signal tracking performance. The proposed methods are illustrated and validated through simulations.

Wang, Peng↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

Lian, Jianming↗

Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads

Coordinated control of electric loads can provide valuable grid services, such as frequency regulation. However, due to the nonlinear characteristics of such load ensembles, it is important to systematically analyze their behavior and establish a thorough understanding of undesirable phenomena that can potentially arise. In this paper, we analyze the frequency response of an aggregate control scheme, with the goal of exploring controller performance limits. We show that rapid switching commands can induce oscillations in the power output due to the inherent lockout mechanism of the underlying devices. Here, we demonstrate that highly detailed aggregate models are required to capture such phenomena. Such models enable deeper understanding of the control boundaries and therefore play an important role in avoiding the introduction of undesirable effects on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems and methods for randomized energy draw or supply requests

The present disclosure can provide a distributed and anonymous approach to demand response of an electricity system. The approach can conceptualize energy consumption and production of distributed-energy resources (DERs) via discrete energy packets that are coordinated by a cyber computing entity that grants or denies energy packet requests from the DERs. The approach leverages a condition of a DER, which is particularly useful for (1) thermostatically-controlled loads, (2) non-thermostatic conditionally-controlled loads, and (3) bi-directional distributed energy storage systems, among others. In a first aspect of the present approach, each DER independently requests the authority to switch on for a fixed amount of time (i.e., packet duration). The coordinator determines whether to grant or deny each request based electric grid and/or energy or power market conditions. In a second aspect, bi-directional DERs, such as distributed-energy storage systems (DESSs) are further able to request to supply energy to the grid.

Frolik, Jeff↗

Centralized and Decentralized Optimal Control of Variable Speed Heat Pumps

Utility service providers are often challenged with the synchronization of thermostatically controlled loads. Load synchronization, as a result of naturally occurring and demand-response events, has the potential to damage power distribution equipment. Because thermostatically controlled loads constitute most of the power consumed by the grid at any given time, the proper control of such devices can lead to significant energy savings and improved grid stability. The contribution of this paper is the development of an optimal control algorithm for commonly used variable speed heat pumps. By means of selective peer-to-peer communication, our control architecture allows for the regulation of home temperatures while simultaneously minimizing aggregate power consumption, and aggregate load volatility. An optimal centralized controller is also explored and compared against its decentralized counterpart.

30 DIRECT ENERGY CONVERSION↗

Robust Distribution System Load Restoration With Time-Dependent Cold Load Pickup

Service restoration is one of the critical functions to enable the future self-healing distribution system. To restore the distribution system in a timely and reliable manner, the realistic system operating conditions need to be accurately characterized. Here, two main factors that have great impacts on distribution system restoration (DSR) in practice are investigated. First, cold load pickup (CLPU), generally caused by thermostatically controlled loads (TCLs), is a common phenomenon after an outage and shaped by the outage duration. However, the time-dependent behaviors of CLPU are rarely considered in literature. In this paper, the operating state evolution of TCLs after an outage is analyzed to characterize time-dependent CLPU. And the time-dependent CLPU is analytically embedded in DSR to accurately represent the actual behaviors of the restored loads. Second, it is difficult to predict loads that fluctuate during DSR due to the lack of real-time measurement data. Accordingly, a robust DSR based on the information gap decision theory (IGDT) is proposed to address this challenge, fully considering the uncertainty of CLPU. The proposed models are tested in IEEE 13-node and 123-node test feeders. Simulation results demonstrate that the time-dependent CLPU model and the uncertainty modeling of CLPU can accurately capture the actual behaviors of loads with TCLs after an outage, which greatly improves DSR decisions in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Controlling Air Conditioners for Frequency Regulation: A Real-World Example

Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. Here, we argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for randomized, packet-based power management of conditionally-controlled loads and bi-directional distributed energy storage systems

The present disclosure provides a distributed and anonymous approach to demand response of an electricity system. The approach conceptualizes energy consumption and production of distributed-energy resources (DERs) via discrete energy packets that are coordinated by a cyber computing entity that grants or denies energy packet requests from the DERs. The approach leverages a condition of a DER, which is particularly useful for (1) thermostatically-controlled loads, (2) non-thermostatic conditionally-controlled loads, and (3) bi-directional distributed energy storage systems. In a first aspect of the present approach, each DER independently requests the authority to switch on for a fixed amount of time (i.e., packet duration). The coordinator determines whether to grant or deny each request based electric grid and/or energy or power market conditions. In a second aspect, bi-directional DERs, such as distributed-energy storage systems (DESSs) are further able to request to supply energy to the grid.

Frolik, Jeff↗

Peak Reduction in a Residential Community Through Bayesian Optimization of Transactive Control Signals

Daily residential power consumption in aggregate tends to have a large peak that places stress on the distribution system and induces high operational costs. This work shows that coordinated transactive control of noncritical loads within a residential community or microgrid can help to alleviate peak-time stress on the distribution system by flattening the aggregate load curve. Treating the load forecaster as a high-fidelity, expensive black-box function, a new algorithm utilizing Bayesian optimization (BO) is proposed to achieve the best solution under uncertainty with minimal computing effort. The proposed BO algorithm manipulates the shape of the load based on transactive signals sent to each home. The thermostatically controlled loads (TCLs) act out of self-interest in response to the given price while maintaining comfort, and the optimizer exploits the thermal energy retention of the homes for the benefit of the community. Simulations confirm consistent neighborhood-level peak power reduction and energy cost savings.

Schomer, Ian↗