Design and analysis study of a spacecraft optical transceiver package

A detailed system level design of an Optical Transceiver Package (OPTRANSPAC) for a deep space vehicle whose mission is outer planet exploration is developed. In addition to the terminal design, this study provides estimates of the dynamic environments to be encountered by the transceiver throughout its mission life. Optical communication link analysis, optical thin lens design, electronic functional design and mechanical layout and packaging are employed in the terminal design. Results of the study describe an Optical Transceiver Package capable of communicating to an Earth Orbiting Relay Station at a distance of 10 Astronomical Units (AU) and data rates up to 100 KBPS. The transceiver is also capable of receiving 1 KBPS of command data from the Earth Relay. The physical dimensions of the terminal are contained within a 3.5' x 1.5' x 2.0' envelope and the transceiver weight and power are estimated at 52.2 Kg (115 pounds) and 57 watts, respectively.

Lambert, S. G.↗

Field distribution in a thin lens

Quasi-optical formulation gives an optical field distribution by computing only two terms. First term represents geometrical optics effect, and second term represents diffraction effect; thus, mathematical expression is simplified, and considerable computer time is saved.

Chi, C. H.↗

Optical Imaging for Machine Vision [Slides]

This slide deck is intended for proper specification and procurement of cameras and (thin) lenses for machine vision applications. This will include equations that allow one to calculate image size, field of view, depth of field, and length of extension tubes required to focus the image. This requires knowledge of the camera sensor, lens, distance to imaged object, and visual acuity.

42 ENGINEERING↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrathin, polarization-independent, achromatic metalens for focusing visible light

An optical device includes a titanium dioxide substrate layer on a quartz base of a substrate. The substrate is configured to focus light in visible wavelength spectrum of 400 nm to 700 nm. The substrate comprises a first zone and a second zone. In some embodiments, the first zone and the second zone are concentric circles. A plurality of resonators are disposed on the substrate, the plurality of resonators comprising a first plurality corresponding to the first zone and a second plurality corresponding to the second zone. Each resonator is comprised of a dielectric material with a defined thickness “t” in the range of 30 nm to 300 nm. Each resonator has a radius “r” in the range of 30 nm to 300 nm and a gap “g” between adjacent resonators in the range of 5 nm to 200 nm. The first plurality of resonators in the first zone have a first radius within a first radius range that is different from a second radius range of the second plurality of resonators in the second zone. The plurality of resonators form a metasurface that defines at least in part an ultra-thin achromatic lens of the optical device.

47 OTHER INSTRUMENTATION↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are thus a key element of many beamlines at X-ray facilities, used to either to focus a beam or image a sample. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam; aligning CRLs is thus typically treated as a time-consuming manual process. Many groups circumvent day-to-day realignment by using engineering controls (e.g. mounting optics) that sacrifice some of the beam’s focusing characteristics, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. Our approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder-Mead (SNM) simplex method. We demonstrate the efficacy of this method by numerical simulation and then extend this test to real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron X-ray beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

97 MATHEMATICS AND COMPUTING↗

Hybrid achromatic microlenses with high numerical apertures and focusing efficiencies across the visible

Abstract Compact visible wavelength achromats are essential for miniaturized and lightweight optics. However, fabrication of such achromats has proved to be exceptionally challenging. Here, using subsurface 3D printing inside mesoporous hosts we densely integrate aligned refractive and diffractive elements, forming thin high performance hybrid achromatic imaging micro-optics. Focusing efficiencies of 51–70% are achieved for 15μm thick, 90μm diameter, 0.3 numerical aperture microlenses. Chromatic focal length errors of less than 3% allow these microlenses to form high-quality images under broadband illumination (400–700 nm). Numerical apertures upwards of 0.47 are also achieved at the cost of some focusing efficiency, demonstrating the flexibility of this approach. Furthermore, larger area images are reconstructed from an array of hybrid achromatic microlenses, laying the groundwork for achromatic light-field imagers and displays. The presented approach precisely combines optical components within 3D space to achieve thin lens systems with high focusing efficiencies, high numerical apertures, and low chromatic focusing errors, providing a pathway towards achromatic micro-optical systems.

47 OTHER INSTRUMENTATION↗

Micro-Thin Lens Final Report CRADA No. TC-0331-92

The general objective of the CRADA was to develop ophthalmic optical elements that are so thin that they can be placed on the human eye in revolutionary new ways. More .specifically,the major accomplishment of this CRADA was to study the feasability of producing a prototype optical element in the form of a bifocal contact lens, for presbyopic vision correction.

59 BASIC BIOLOGICAL SCIENCES↗

Micro-Ball-Lens Optical Switch Driven by SMA Actuator

The figure is a simplified cross section of a microscopic optical switch that was partially developed at the time of reporting the information for this article. In a fully developed version, light would be coupled from an input optical fiber to one of two side-by-side output optical fibers. The optical connection between the input and the selected output fiber would be made via a microscopic ball lens. Switching of the optical connection from one output fiber to another would be effected by using a pair of thin-film shape-memory-alloy (SMA) actuators to toggle the lens between two resting switch positions. There are many optical switches some made of macroscopic parts by conventional fabrication techniques and some that are microfabricated and, hence, belong to the class of microelectromechanical systems (MEMS). Conventionally fabricated optical switches tend to be expensive. MEMS switches can be mass-produced at relatively low cost, but their attractiveness has been diminished by the fact that, heretofore, MEMS switches have usually been found to exhibit high insertion losses. The present switch is intended to serve as a prototype of low-loss MEMS switches. In addition, this is the first reported SMA-based optical switch. The optical fibers would be held in V grooves in a silicon frame. The lens would have a diameter of 1 m; it would be held by, and positioned between, the SMA actuators, which would be made of thin films of TiNi alloy. Although the SMA actuators are depicted here as having simple shapes for the sake of clarity of illustration, the real actuators would have complex, partly net-like shapes. With the exception of the lens and the optical fibers, the SMA actuators and other components of the switch would be made by microfabrication techniques. The components would be assembled into a sandwich structure to complete the fabrication of the switch. To effect switching, an electric current would be passed through one of the SMA actuators to heat it above its transition temperature, thereby causing it to deform to a different "remembered" shape. The two SMA actuators would be stiff enough that once switching had taken place and the electrical current was turned off, the lens would remain latched in the most recently selected position. In a test, the partially developed switch exhibited an insertion loss of only -1.9 dB and a switching contrast of 70 dB. One the basis of prior research on SMA actuators and assuming a lens displacement of 125 m between extreme positions, it has been estimated that the fully developed switch would be capable of operating at a frequency as high as 10 Hz.

Yang, Eui-Hyeok↗

Method of adiabatic modes in research of smoothly irregular integrated optical waveguides: zero approximation

We consider the application of the method of adiabatic waveguide modes for calculating the propagation of electromagnetic radiation in three-dimensional (3D) irregular integrated optical waveguides. The method of adiabatic modes takes into account a three-dimensional distribution of quasi-waveguide modes and explicit ('inclined') tangential boundary conditions. The possibilities of the method are demonstrated on the example of numerical research of two major elements of integrated optics: a waveguide of 'horn' type and a thin-film generalised waveguide Luneburg lens by the methods of adiabatic modes and comparative waveguides. (integral optical waveguides)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase-space analysis and experimental results for secondary focusing at X-ray beamlines

Micro-focusing optical devices at synchrotron beamlines usually have a limited acceptance, but more flux can be intercepted if such optics are used to focus secondary sources created by the primary optics. Flux throughput can be maximized by placing the secondary focusing optics close to or exactly at the secondary source position. However, standard methods of beamline optics analysis, such as the lens equation or matching the mirror surface to an ellipse, work poorly when the source-to-optics distance is very short. In this paper the general characteristics of the focusing of beams with Gaussian profiles by a 'thin lens' are analysed under the paraxial approximation in phase space, concluding that the focusing of a beam with a short source-to-optics distance is distinct from imaging the source; slope errors are successfully included in all the formulas so that they can be used to calculate beamline focusing with good accuracy. A method is also introduced to use the thin-lens result to analyse the micro-focusing produced by an elliptically bent trapezoid-shaped Kirkpatrick-Baez mirror. The results of this analysis are in good agreement with ray-tracing simulations and are confirmed by the experimental results of the secondary focusing at the 18-ID Bio-CAT beamline (at the APS). The result of secondary focusing carried out at 18-ID using a single-bounce capillary can also be explained using this phase-space analysis. A discussion of the secondary focusing results is presented at the end of this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced photothermal lens using a photonic crystal surface

A photonic crystal (PC)-enhanced photothermal lens (PTL) is demonstrated for the detection of optically thin light absorption materials. The PC-enhanced PTL system is based on a pump-probe scheme consisting of a PC surface, pump laser beam, and probe laser beam. Heated by the pump beam, light absorption materials on the PC surface generate the PTL and cause a substantial change to the guided-mode resonance supported by the PC structure. The change of the PC resonance is detected using the probe laser beam by measuring its reflectivity from the PC surface. When applied to analyze dye molecules deposited on the PC substrate, the developed system is capable of enhancing the PTL signal by 10-fold and reducing the lowest distinguishable concentration by 8-fold, in comparison to measuring without utilizing the PC resonance. The PC-enhanced PTL was also used to detect gold nanoparticles on the PC surface and exhibited a 20-fold improvement of the lowest distinguishable concentration. The PC-enhanced PTL technology offers a potential tool to obtain the absorption signatures of thin films in a broad spectral range with high sensitivity and inexpensive instrumentation. As a result, this technology will enable a broad range of applications of photothermal spectroscopy in chemical analysis and biomolecule sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical data processing study

An onboard coherent optical data processing system was designed to handle large information content of imagery at high speeds, reduce redundancy in picture transmission, and detect specific image features. Theoretically derived Fourier transform characteristics for simple but representative two dimensional images served as a basis for predicting expected features of actual target images. Fourier transformation and spatial filtering of coherent optical images was accomplished theoretically and in the laboratory. The effect of various parameters such as optical aperature, incidence angles, the transparency assumption, the thin lens approximation on resolution, and performance of the system are predicted and tested.

Pinson, L. J.↗

Focusing of intense laser beam by a thin axially magnetized plasma lens

Focusing of intense laser beams by a thin magnetized plasma slab is investigated. A thin plasma slab is used as an optical element. The focal length is the distance between the plasma lens and the laser beam focus point. The external magnetic field is applied along the direction of the laser field propagation. The nonlinear current density induced in the plasma lens is derived up to the third order of perturbation and the evolution of the spot size for a Gaussian beam profile is determined by making use of the variational principle approach method. It is shown that the axially magnetic field decreases the minimum spot size and increases the focal length significantly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Micro-optics for imaging.

This project investigates the fundamental imaging capability of an optic with a physical thickness substantially less than 1 mm. The analysis assumes that post-processing can overcome certain restrictions such as detector pixel size and image degradation due to aberrations. A first order optical analysis quickly reveals the limitations of even an ideal thin lens to provide sufficient image resolution and provides the justification for pursuing an annular design. Some straightforward examples clearly show the potential of this approach. The tradeoffs associated with annular designs, specifically field of view limitations and reduced mid-level spatial frequencies, are discussed and their impact on the imaging performance evaluated using several imaging examples. Additionally, issues such as detector acceptance angle and the need to balance aberrations with resolution are included in the analysis. With these restrictions, the final results present an excellent approximation of the expected performance of the lens designs presented.

42 ENGINEERING↗

Surface characterization and testing II; Proceedings of the Meeting, San Diego, CA, Aug. 10, 11, 1989

Various papers on surface characterization and testing are presented. Individual topics addressed include: simple Hartmann test data interpretation, optimum configuration of the Offner null corrector, system for phase-shifting interferometry in the presence of vibration, fringe variation and visibility in speckle-shearing interferometry, functional integral representation of rough surfaces, calibration of surface heights in an interferometric optical profiler, image formation in common path differential profilometers, SEM of optical surfaces, measuring surface profiles with scanning tunneling microscopes, surface profile measurements of curved parts, high-resolution optical profiler, scanning heterodyne interferometer with immunity from microphonics, real-time crystal axis measurements of semiconductor materials, radial metrology with a panoramic annular lens, surface analysis for the characterization of defects in thin-film processes, Spacelab Optical Viewport glass assembly optical test program for the Starlab mission, scanning differential intensity and phase system for optical metrology.

Greivenkamp, John E.↗

Higher-order harmonic generation and strong field ionization with Bessel–Gauss beams in a thin jet geometry

A promising alternative to Gaussian beams for use in strong field science is Bessel–Gauss (BG or Bessel-like) laser beams, as they are easily produced with readily available optics and provide more flexibility of the spot size and working distances. Here we use BG beams produced with a lens-axicon optical system for higher-order harmonic generation (HHG) in a thin gas jet. The finite size of the interaction region allows for scans of the HHG yield along the propagation axis. Further, by measuring the ionization yield in unison with the extreme ultraviolet (XUV), we are able to distinguish regions of maximum ionization from regions of optimum XUV generation. This distinction is of great importance for BG fields, as the generation of BG beams with axicons often leads to oscillations of the on-axis intensity, which can be exploited for extended phase-matching conditions. We observed such oscillations in the ionization and XUV flux along the propagation axis for the first time. As is the case for Gaussian modes, the harmonic yield is not maximum at the point of highest ionization. Finally, despite Bessel beams having a hole in the center in the far field, the XUV beam is well collimated, making BG modes a great alternative when spatial filtering of the fundamental is desired.

Davino, Michael↗

Preliminary Investigation of an Active PLZT Lens

The design, analysis and preliminary testing of a prototype Adjustable Focus Optical Correction Lens (AFOCL) is described. The AFOCL is an active optical component composed of solid state lead lanthanum-modified zirconate titanate (PLZT) ferroelectric ceramic with patterned indium tin oxide (ITO) transparent surface electrodes that modulate the refractive index of the PLZT to function as an electro-optic lens. The AFOCL was developed to perform optical re-alignment and wavefront correction to enhance the performance of Ultra-Lightweight Structures and Space Observatories (ULSSO). The AFOCL has potential application as an active optical component within a larger optical system. As such, information from a wavefront sensor would be processed to provide input to the AFOCL to drive the sensed wavefront to the desired shape and location. While offering variable and rapid focussing capability (controlled wavefront manipulation) similar to liquid crystal based spatial light modulators (SLM), the AFOCL offers some potential advantages because it is a solid-state, stationary, low-mass, rugged, and thin optical element that can produce wavefront quality comparable to the solid refractive lens it replaces. The AFOCL acts as a positive or negative lens by producing a parabolic phase-shift in the PLZT material through the application of a controlled voltage potential across the ITO electrodes. To demonstrate the technology, a 4 mm diameter lens was fabricated to produce 5-waves of optical power operating at 2.051 micrometer wavelength. Optical metrology was performed on the device to measure focal length, optical quality, and efficiency for a variety of test configurations. The data was analyzed and compared to theoretical data available from computer-based models of the AFOCL.

Lightsey, W. D.↗