Comparison of frequency domain and time domain laser velocimeter signal processors

An experimental investigation was conducted in the 14- by 22-foot subsonic tunnel at NASA-Langley Research Center to measure the inflow into a scale model helicopter rotor in forward flight. These inflow measurements were acquired utilizing a two-component laser velocimeter, and the data were processed by a frequency-domain processor (FDP). As a subset of the experiment, a time-domain counter processor was utilized simultaneously with an FDP to make a comparison of the two processors possible. The results indicate that the FDP had a marked improvement in processing capability in conditions of low signal-to-noise ratios and had a reduction in the number of erroneous data points acquired. However, the FDP yielded a lower data rate in comparison to the counter when signal-to-noise ratios were high. Comparison of the data sets shows that the FDP consistantly measures velocities which are 0.7 percent higher than those measured by the counter processor.

Mace, W. D., Jr.↗

A cost-effective component modes analysis for Shuttle payloads using a combination of frequency domain and time domain approaches

A combination of the time and frequency domains which employs the latter only where the former is inefficient or uncertain is used in Space Shuttle payloads' component mode analyses. Attention is given to the time histories at the launch vehicle/spacecraft interface. The frequency domain allows interface acceleration to be determined without recourse to a new, merged system eigenvalue solution and subsequent 'system modal' responses. The approach has been employed in Galileo spacecraft loads analyses.

Trubert, M.↗

Spread Spectrum Time Domain Reflectometry and Steepest Descent Inversion to Measure Complex Impedance

In this paper, we present a method for estimating complex impedances using reflectometry and a modified steepest descent inversion algorithm. We simulate spread spectrum time domain reflectometry (SSTDR), which can measure complex impedances on energized systems for an experimental setup with resistive and capacitive loads. A parametric function, which includes both a misfit function and stabilizer function, is created. The misfit function is a least squares estimate of how close the model data matches observed data. The stabilizer function prevents the steepest descent algorithm from becoming unstable and diverging. Steepest descent iteratively identifies the model parameters that minimize the parametric function. We validate the algorithm by correctly identifying the model parameters (capacitance and resistance) associated with simulated SSTDR data, with added 3 dB white Gaussian noise. With the stabilizer function, the steepest descent algorithm estimates of the model parameters are bounded within a specified range. Furthermore, the errors for capacitance (220pF to 820pF) and resistance (50 Ω to 270 Ω) are < 10%, corresponding to a complex impedance magnitude |R +1/jωC| of 53 Ω to 510 Ω.

14 SOLAR ENERGY↗

Time domain reflectometry in time variant plasmas

The effects of time-dependent electron density fluctuations on a synthesized time domain reflectometry response of a one-dimensional cold plasma sheath are considered. Numerical solutions of the Helmholtz wave equation, which describes the electric field of a normally incident plane wave in a specified static electron density profile, are used. A study of the effects of Doppler shifts resulting from moving density fluctuations in the electron density profile of the sheath is included. Varying electron density levels corrupt time domain and distance measurements. Reducing or modulating the electron density levels of a given electron density profile affects the time domain response of a plasma and results in motion of the turning point, and the effective motion has a significant effect on measuring electron density locations.

Scherner, Michael J.↗

Identifying DQ-Domain Admittance Models of a 2.3-MVA Commercial Grid-Following Inverter Via Frequency-Domain and Time-Domain Data

Here, we present two methods to identify the admittance of a 2.3-MVA commercial grid-following inverter through frequency-domain data and time-domain data. In addition to the well-known harmonic injection method to obtain the admittance at frequency points followed by vector fitting, we adopt a step response-based method where the step response data of the converter are collected and their s-domain expressions are obtained. In turn, the s-domain admittance model of the converter is found. The two methods can be used for cross validation. Step responses and frequency-domain responses obtained from the two methods are compared. Results show that the time- domain data-based method leads to an admittance comparable with that from the frequency-domain measurement in the range less than 60 Hz. In addition, two insights are obtained from the frequency-domain admittance measurements. First, when the dq- frame is aligned to the point of common coupling (PCC) voltage, the per unit DQ-domain admittance directly reflects operating conditions. Second, existence of negative-sequence control can be detected via sequence-domain admittances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An in flight investigation of pitch rate flight control systems and application of frequency domain and time domain predictive criteria

The degree of attitude control provided by current integral-proportional pitch rate command-type control systems, while a prerequisite for flared landing, is insufficient for 'Level 1' performance. The pilot requires 'surrogate' feedback cues to precisely control flight path in the landing flare. Monotonic stick forces and pilot station vertical acceleration are important cues which can be provided by means of angle-of-attack and pitch rate feedback in order to achieve conventional short period and phugoid characteristics. Integral-proportional pitch rate flight control systems can be upgraded to Level 1 flared landing performance by means of lead/lag and washout prefilters in the command path. Strong pilot station vertical acceleration cues can provide Level 1 flared landing performance even in the absence of monotonic stick forces.

Berthe, C. J.↗

Nonlinear (time domain) and linearized (time and frequency domain) solutions to the compressible Euler equations in conservation law form

Two linearized solvers (time and frequency domain) based on a high resolution numerical scheme are presented. The basic approach is to linearize the flux vector by expressing it as a sum of a mean and a perturbation. This allows the governing equations to be maintained in conservation law form. A key difference between the time and frequency domain computations is that the frequency domain computations require only one grid block irrespective of the interblade phase angle for which the flow is being computed. As a result of this and due to the fact that the governing equations for this case are steady, frequency domain computations are substantially faster than the corresponding time domain computations. The linearized equations are used to compute flows in turbomachinery blade rows (cascades) arising due to blade vibrations. Numerical solutions are compared to linear theory (where available) and to numerical solutions of the nonlinear Euler equations.

Sreenivas, Kidambi↗

Comparison of frequency-domain and time-domain rotorcraft vibration control methods

Active control of rotor-induced vibration in rotorcraft has received significant attention recently. Two classes of techniques have been proposed. The more developed approach works with harmonic analysis of measured time histories and is called the frequency-domain approach. The more recent approach computes the control input directly using the measured time history data and is called the time-domain approach. The report summarizes the results of a theoretical investigation to compare the two approaches. Five specific areas were addressed: (1) techniques to derive models needed for control design (system identification methods), (2) robustness with respect to errors, (3) transient response, (4) susceptibility to noise, and (5) implementation difficulties. The system identification methods are more difficult for the time-domain models. The time-domain approach is more robust (e.g., has higher gain and phase margins) than the frequency-domain approach. It might thus be possible to avoid doing real-time system identification in the time-domain approach by storing models at a number of flight conditions. The most significant error source is the variation in open-loop vibrations caused by pilot inputs, maneuvers or gusts. The implementation requirements are similar except that the time-domain approach can be much simpler to implement if real-time system identification were not necessary.

Gupta, N. K.↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗

Frequency-domain vs time-domain SP{sub N} equations to simulate neutron noise

Inside the reactor core mechanical vibrations of fuel assemblies can produce high fluctuations around a steady-state configuration, known as neutron noise. This effect can cause the triggering of power reduction measures. Classically, diffusion theory has been used to simulate this behavior. However, this equation has some limitations if the materials of the reactor have strong variations. In this work, we use the diffusive time-dependent simplified spherical harmonics equations that improve the previous results without the necessity of using high computational requirements. In particular, two types of analyses with these equations (SP{sub 3}) are made: a frequency-domain and a time-domain. A numerical neutron noise benchmark tests the methodology and compare both formulations. First, numerical results show a good agreement between the amplitudes and phases of the SP3 equations computed with the frequency-domain and time-domain. Therefore, as the frequency-domain computation only requires to solve a linear system, it is a recommendable option for neutron noise computations. Second, one can conclude that for this type of nuclear systems, where the assemblies are not homogenized, the SP{sub 3} approximation results improve considerably the accuracy of the diffusion theory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced propeller noise prediction in the time domain

The time domain code ASSPIN gives acousticians a powerful technique of advanced propeller noise prediction. Except for nonlinear effects, the code uses exact solutions of the Ffowcs Williams-Hawkings equation with exact blade geometry and kinematics. By including nonaxial inflow, periodic loading noise, and adaptive time steps to accelerate computer execution, the development of this code becomes complete.

Farassat, F.↗

Frequency and Time Domain Modeling of Acoustic Liner Boundary Conditions

As part of a research program directed at the acoustics of advanced subsonic propulsion systems undertaken at NASA Langley, Duke University was funded to develop a boundary condition model for bulk-reacting nacelle liners. The overall objective of the Langley program was to understand and predict noise from advanced subsonic transport engines and to develop related noise control technology. The overall technical areas included: fan and propeller source noise, acoustics of ducts and duct liners, interior noise, subjective acoustics, and systems noise prediction. The Duke effort was directed toward duct liner acoustics for the development of analytical methods to characterize liner behavior in both frequency domain and time domain. A review of duct acoustics and liner technology can be found in Reference [1]. At that time, NASA Langley was investigating the propulsion concept of an advanced ducted fan, with a large diameter housed inside a relatively short duct. Fan diameters in excess of ten feet were proposed. The lengths of both the inlet and exhaust portions of the duct were to be short, probably less than half the fan diameter. The nacelle itself would be relatively thin-walled for reasons of aerodynamic efficiency. The blade-passage frequency was expected to be less than I kHz, and very likely in the 200 to 300 Hz range. Because of the design constraints of a short duct, a thin nacelle, and long acoustic wavelengths, the application of effective liner technology would be especially challenging. One of the needs of the NASA Langley program was the capability to accurately and efficiently predict the behavior of the acoustic liner. The traditional point impedance method was not an adequate model for proposed liner designs. The method was too restrictive to represent bulk reacting liners and to allow for the characterization of many possible innovative liner concepts. In the research effort at Duke, an alternative method, initially developed to handle bulk reacting layers as described in Reference [2], was extended to apply to a broad range of liner types. This method included the effect of local gradients along the liner surface, and was particularly appropriate for situations with flow over the liner and grazing incidence acoustic fields. In order to utilize time domain computational methods to solve for the propfan acoustic field, corresponding liner boundary conditions were developed for time domain solutions rather than frequency domain solutions.

Bliss, Donald B.↗

Continuous liquid level measurements with time domain reflectometry

A time domain reflectometer is considered as a closed loop, one-dimensional radar system. Applying the principle of time domain reflectometry to the detection of cryogenic liquid levels, measurements on the order of + or - 0. 3% of total liquid level probe length are possible. The time domain reflectometer liquid level measurement is independent of liquid density variations and is simple to calibrate and operate. Construction of the liquid level sensing probe is described.

Cruz, J. E.↗

Uncovering extreme nonlinear dynamics in solids through time-domain field analysis

Time-domain analysis of harmonic fields with sub-cycle resolution is now experimentally viable due to the emergence of sensitive, on-chip techniques for petahertz-scale optical-field sampling. We demonstrate how such a time-domain, field-resolved analysis uncovers the extreme nonlinear electron dynamics responsible for high-harmonic generation within solids. Time-dependent density functional theory was used to simulate harmonic generation from a solid-state band-gap system driven by near- to mid-infrared waveforms. Particular attention was paid to regimes where both intraband and interband emission mechanisms play a critical role in shaping the nonlinear response. We show that a time-domain analysis of the harmonic radiation fields identifies the interplay between intra- and interband dynamical processes underlying the nonlinear light generation. With further analysis, we show that changes to the dominant emission regime can occur after only slight changes to the peak driving intensity and central driving wavelength. Furthermore, time-domain analysis of harmonic fields also reveals, for the first time, the possibility of rapid changes in the dominant emission mechanism within the temporal window of the driving pulse envelope. Finally, we examine the experimental viability of performing time-domain analysis of harmonic fields with sub-cycle resolution using realistic parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

Methodology for Time-Domain Estimation of Storm Time Geoelectric Fields Using the 3-D Magnetotelluric Response Tensors

Geoelectric fields at the Earth's surface caused by magnetic storms constitute a hazard to the operation of electric power grids and related infrastructure. The ability to estimate these geoelectric fields in close to real time and provide local predictions would better equip the industry to mitigate negative impacts on their operations. Here we report progress toward this goal: development of robust algorithms that convolve a magnetic storm time series with a frequency domain impedance for a realistic three-dimensional (3-D) Earth, to estimate the local, storm time geoelectric field. Both frequency domain and time domain approaches are presented and validated against storm time geoelectric field data measured in Japan. The methods are then compared in the context of a real-time application.

Kelbert, Anna↗