Search NASA⌕ Search

SEARCH · Search NASA

Results for “time factors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Meta-analysis of the Alpha/Beta Ratio for Prostate Cancer in the Presence of an Overall Time Factor: Bad News, Good News, or No News?

Purpose: To present a novel method for meta-analysis of the fractionation sensitivity of tumors as applied to prostate cancer in the presence of an overall time factor. Methods and Materials: A systematic search for radiation dose-fractionation trials in prostate cancer was performed using PubMed and by manual search. Published trials comparing standard fractionated external beam radiation therapy with alternative fractionation were eligible. For each trial the {alpha}/{beta} ratio and its 95% confidence interval (CI) were extracted, and the data were synthesized with each study weighted by the inverse variance. An overall time factor was included in the analysis, and its influence on {alpha}/{beta} was investigated. Results: Five studies involving 1965 patients were included in the meta-analysis of {alpha}/{beta}. The synthesized {alpha}/{beta} assuming no effect of overall treatment time was -0.07 Gy (95% CI -0.73-0.59), which was increased to 0.47 Gy (95% CI -0.55-1.50) if a single highly weighted study was excluded. In a separate analysis, 2 studies based on 10,808 patients in total allowed extraction of a synthesized estimate of a time factor of 0.31 Gy/d (95% CI 0.20-0.42). The time factor increased the {alpha}/{beta} estimate to 0.58 Gy (95% CI -0.53-1.69)/1.93 Gy (95% CI -0.27-4.14) with/without the heavily weighted study. An analysis of the uncertainty of the {alpha}/{beta} estimate showed a loss of information when the hypofractionated arm was underdosed compared with the normo-fractionated arm. Conclusions: The current external beam fractionation studies are consistent with a very low {alpha}/{beta} ratio for prostate cancer, although the CIs include {alpha}/{beta} ratios up to 4.14 Gy in the presence of a time factor. Details of the dose fractionation in the 2 trial arms have critical influence on the information that can be extracted from a study. Studies with unfortunate designs will supply little or no information about {alpha}/{beta} regardless of the number of subjects enrolled.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endogenous timing factors in bird migration

Several species of warbler birds were observed in an effort to determine what initiates and terminates migration. Environmental and endogenous timing mechanisms were analyzed. The results indicate that endogenous stimuli are dominant factors for bird migration especially for long distances. It was concluded that environmental factors act as an assist mechanism.

Gwinner, E. G.↗

MEPHESTO: Modeling Energy-Performance in Heterogeneous SoCs and Their Trade-Offs

Integrated shared memory heterogeneous architectures are pervasive because they satisfy the diverse needs of mobile, autonomous, and edge computing platforms. Although specialized processing units (PUs) that share a unified system memory improve performance and energy efficiency by reducing data movement, they also increase contention for this memory since the PUs interact with each other. Prior work has investigated performance degradation due to memory contention, but few have studied the relationship of power and energy to memory contention. Moreover, a comprehensive solution that models memory contention for kernel placement on contemporary heterogeneous systems on chip (SoCs) in response to energy and performance has been largely unaddressed.This paper presents MEPHESTO, a novel and holistic approach for managing this balance. The authors characterize applications and PUs in terms of two memory contention factors - time factors and power factors - to achieve the desired trade-off between energy and performance for collocated kernel execution on heterogeneous systems. The authors believe that this investigation is the first to combine all of these factors and present a simple knob-based approach that expresses the target trade-off. The approach is evaluated on a diverse integrated shared memory heterogeneous system with a CPU, GPU, and programmable vision accelerator. By using an empirical model for memory contention that provides up to 92% accuracy, the kernel collocation approach can provide a near-optimal ordering and placement based on the user-defined, energy-performance trade-off parameter. Moreover, the dynamic programming-based heuristics provide up to 30% better energy or 20% performance benefits when compared with the greedy approaches commonly employed by previous studies.

Alaul haque monil, Mohammad↗

A Practical Approach to a Closed Nuclear Fuel Cycle and Sustained Nuclear Energy - 12383

Recent systems analysis studies at Oak Ridge National Laboratory (ORNL) have shown that sufficient information is available from previous research and development (R and D), industrial experience, and current studies to make rational decisions on a practical approach to a closed nuclear fuel cycle in the United States. These studies show that a near-term decision is needed to recycle used nuclear fuel (UNF) in the United States, to encourage public recognition that a practical solution to disposal of nuclear energy wastes, primarily UNF, is achievable, and to ensure a focus on essential near-term actions and future R and D. Recognition of the importance of time factors is essential, including the multi-decade time period required to implement industrial-scale fuel recycle at the capacity needed, and the effects of radioactive decay on proliferation resistance, recycling complexity, radioactive emissions, and high-level-waste storage, disposal form development, and eventual emplacement in a geologic repository. Analysis of time factors led to identification of the benefits of processing older fuel and an 'optimum decay storage time'. Further benefits of focused R and D can ensure more complete recycling of UNF components and minimize wastes requiring disposal. Analysis of recycling costs and nonproliferation requirements, which are often cited as reasons for delaying a decision to recycle, shows that (1) the differences in costs of nuclear energy with open or closed fuel cycles are insignificant and (2) nonproliferation requirements can be met by a combination of 'safeguards-by-design' co-location of back-end fuel cycle facilities, and applied engineered safeguards and monitoring. The study shows why different methods of separating and recycling used fuel components do not have a significant effect on nonproliferation requirements and can be selected on other bases, such as process efficiency, maturity, and cost-effectiveness. Finally, the study concludes that continued storage of UNF without a decision to recycle is not a solution to the problem of nuclear waste disposal, but can be a deterrent to public confidence in nuclear energy. In summary, our studies have shown, in contrast to findings of the more prominent studies, that today we do have sufficient knowledge to make informed choices for the values and essential methods of UNF recycling, based on previous research, industrial experience, and current analyses. We have shown the significant importance of time factors, including the benefits of an optimum decay storage time on deploying effective nonproliferation safeguards, enabling reduced recycling complexity and environmental emissions, and optimizing waste management and disposal. Together with the multi-decade time required to implement industrial-scale UNF recycle at the capacity needed to match generation rate, our conclusion is that a near-term decision to recycle as many UNF components as possible is vitally needed. Further indecision and procrastination can lead to a loss of public confidence and favorable perception of nuclear energy. With no near-term decision, the path forward for UNF disposal will remain uncertain, with many diverse technologies being considered and no possible focus on a practical solution to the problem. However, a near-term decision to recycle UNF fuel and to take advantage of processing UNF and surface storing HLW, together with development and incorporation of more-complete recycling of UNF components, can provide the focus needed for a practical solution to the problem of nuclear waste disposal. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Landau electron in a rotating environment: A general factorization of time evolution

For the Landau problem with a rotating magnetic field and a confining potential in the (changing) direction of the field, we derive a general factorization of the time evolution operator that includes the adiabatic factorization as a special case. The confining potential is assumed to be of a general form and it can correspond to nonlinear Heisenberg equations of motion. The rotation operator associated with the solid angle Berry phase is used to transform the problem to a rotating reference frame. In the rotating reference frame, we derive a natural factorization of the time evolution operator by recognizing the crucial role played by a gauge transformation. The major complexity of the problem arises from the coupling between motion in the direction of the magnetic field and motion perpendicular to the field. In the factorization, this complexity is consolidated into a single operator which approaches the identity operator when the potential confines the particle sufficiently close to a rotating plane perpendicular to the magnetic field. The structure of this operator is clarified by deriving an expression for its generating Hamiltonian. The adiabatic limit and non-adiabatic effects follow as consequences of the general factorization which are clarified using the magnetic translation concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The joint space-time statistics of macroweather precipitation, space-time statistical factorization and macroweather models

Over the range of time scales from about 10 days to 30–100 years, in addition to the familiar weather and climate regimes, there is an intermediate “macroweather” regime characterized by negative temporal fluctuation exponents: implying that fluctuations tend to cancel each other out so that averages tend to converge. We show theoretically and numerically that macroweather precipitation can be modeled by a stochastic weather-climate model (the Climate Extended Fractionally Integrated Flux, model, CEFIF) first proposed for macroweather temperatures and we show numerically that a four parameter space-time CEFIF model can approximately reproduce eight or so empirical space-time exponents. In spite of this success, CEFIF is theoretically and numerically difficult to manage. We therefore propose a simplified stochastic model in which the temporal behavior is modeled as a fractional Gaussian noise but the spatial behaviour as a multifractal (climate) cascade: a spatial extension of the recently introduced ScaLIng Macroweather Model, SLIMM. Both the CEFIF and this spatial SLIMM model have a property often implicitly assumed by climatologists that climate statistics can be “homogenized” by normalizing them with the standard deviation of the anomalies. Physically, it means that the spatial macroweather variability corresponds to different climate zones that multiplicatively modulate the local, temporal statistics. This simplified macroweather model provides a framework for macroweather forecasting that exploits the system's long range memory and spatial correlations; for it, the forecasting problem has been solved. We test this factorization property and the model with the help of three centennial, global scale precipitation products that we analyze jointly in space and in time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modelling the Impact of Fractionation on Late Urinary Toxicity After Postprostatectomy Radiation Therapy

Purpose: To fit urinary toxicity data of patients treated with postprostatectomy radiation therapy with the linear quadratic (LQ) model with/without introducing a time factor. Methods and Materials: Between 1993 and 2010, 1176 patients were treated with conventional fractionation (1.8 Gy per fraction, median 70.2 Gy, n=929) or hypofractionation (2.35-2.90 Gy per fraction, n=247). Data referred to 2004-2010 (when all schemes were in use, n=563; conventional fractionation: 316; hypofractionation: 247) were fitted as a logit function of biological equivalent dose (BED), according to the LQ model with/without including a time factor γ (fixing α/β = 5 Gy). The 3-year risks of severe urethral stenosis, incontinence, and hematuria were considered as endpoints. Best-fit parameters were derived, and the resulting BEDs were taken in multivariable backward logistic models, including relevant clinical variables, considering the whole population. Results: The 3-year incidences of severe stenosis, incontinence, and hematuria were, respectively, 6.6%, 4.8%, and 3.3% in the group treated in 2004-2010. The best-fitted α/β values were 0.81 Gy and 0.74 Gy for incontinence and hematuria, respectively, with the classic LQ formula. When fixing α/β = 5 Gy, best-fit values for γ were, respectively, 0.66 Gy/d and 0.85 Gy/d. Sensitivity analyses showed reasonable values for γ (0.6-1.0 Gy/d), with comparable goodness of fit for α/β values between 3.5 and 6.5 Gy. Likelihood ratio tests showed that the fits with/without including γ were equivalent. The resulting multivariable backward logistic models in the whole population included BED, pT4, and use of antihypertensives (area under the curve [AUC] = 0.72) for incontinence and BED, pT4, and year of surgery (AUC = 0.80) for hematuria. Stenosis data could not be fitted: a 4-variable model including only clinical factors (acute urinary toxicity, pT4, year of surgery, and use of antihypertensives) was suggested (AUC = 0.73). Conclusions: The unexpected impact of moderate hypofractionation on severe incontinence and hematuria after postprostatectomy radiation therapy may be explained by a bladder α/β value <1 Gy or, radiobiologically more plausible, by introducing a time factor likely to represent a previously hypothesized consequential component of late effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Thin Lens Model for Charged-Particle RF Accelerating Gaps

Presented is a thin-lens model for an RF accelerating gap that considers general axial fields without energy dependence or other a priori assumptions. Both the cosine and sine transit time factors (i.e., Fourier transforms) are required plus two additional functions; the Hilbert transforms the transit-time factors. The combination yields a complex-valued Hamiltonian rotating in the complex plane with synchronous phase. Using Hamiltonians the phase and energy gains are computed independently in the pre-gap and post-gap regions then aligned using the asymptotic values of wave number. Derivations of these results are outlined, examples are shown, and simulations with the model are presented.

43 PARTICLE ACCELERATORS↗

Application configuration selection for energy-efficient execution on multicore systems

Balanced performance and energy consumption are incorporated in the design of modern computer systems. Several runtime factors, such as concurrency levels, thread mapping strategies, and dynamic voltage and frequency scaling (DVFS) should be considered in order to achieve optimal energy efficiency fora workload. Selecting appropriate run-time factors, however, is one of the most challenging tasks because the run-time factors are architecture-specific and workload-specific. And while most existing works concentrate on either static analysis of the workload or run-time prediction results, we present a hybrid two-step method that utilizes concurrency levels and DVFS settings to achieve the energy efficiency configuration for a worldoad. The experimental results based on a Xeon E5620 server with NPB and PARSEC benchmark suites show that the model is able to predict the energy efficient configuration accurately. On average, an additional 10% EDP (Energy Delay Product) saving is obtained by using run-time DVFS for the entire system. An off-line optimal solution is used to compare with the proposed scheme. Finally, the experimental results show that the average extra EDP saved by the optimal solution is within 5% on selective parallel benchmarks.

97 MATHEMATICS AND COMPUTING↗

Surface Finishing and Coating Parameters Impact on Additively Manufactured Binder-Jetted Steel–Bronze Composites

In this paper, electroless nickel plating is explored for the protection of binder-jetting-based additively manufactured (AM) composite materials. Electroless nickel plating was attempted on binder-jetted composites composed of stainless steel and bronze, resulting in differences in the physicochemical properties. We investigated the impact of surface finishing, plating solution chemistry, and plating parameters to attain a wide range of surface morphologies and roughness levels. We employed the Keyence microscope to quantitatively evaluate dramatically different surface properties before and after the coating of AM composites. Scanning electron microscopy revealed a wide range of microstructural properties in relation to each combination of surface finishing and coating parameters. We studied chempolishing, plasma cleaning, and organic cleaning as the surface preparation methods prior to coating. We found that surface preparation dictated the surface roughness. Taguchi statistical analysis was performed to investigate the relative strength of experimental factors and interconnectedness among process parameters to attain optimum coating qualities. The quantitative impacts of phosphorous level, temperature, surface preparation, and time factor on the roughness of the nickel-plated surface were 17.95%, 8.2%, 50.02%, and 13.21%, respectively. On the other hand, the quantitative impacts of phosphorous level, temperature, surface preparation, and time factor on the thickness of nickel plating were 35.12%, 41.40%, 3.87%, and 18.24%, respectively. The optimum combination of the factors’ level projected the lowest roughness of Ra at 7.76 µm. The optimum combination of the factors’ level projected the maximum achievable thickness of ~149 µm. This paper provides insights into coating process for overcoming the sensitivity of AM composites in hazardous application spaces via robust coating.

36 MATERIALS SCIENCE↗

Development and Validation of Resistance-Capacitance Model (RCM) for Phase Change Material (PCM) Embedded in 3D Periodic Structures

The low thermal conductivity of Phase Change Materials (PCM) can be improved with extended surfaces such as additively manufactured 3D periodic lattice structures. Three different aluminum alloy-based lattices (base sizes 10, 20, and 40 mm) with average porosity of 0.95 filled with paraffin wax, with a nominal phase change temperature of 55°C, were experimentally investigated. In this work, a computationally efficient 2D Resistance Capacitance-based model (RCM) was developed for predicting the thermal characteristics of these geometries. Non-uniform porosity in the PCM-metal domain was estimated using image processing and served as model input. The solver does not solve for higher-order physics as in CFD but still can provide a good prediction of thermal resistance and energy storage at a very low computational cost. The simulation-to-real-time factor for this geometry is of the order of 10-4, while CFD simulations typically have a real-time factor greater than 1. The model was validated against the experimental data for melting under three different heat fluxes (6250 W/m2, 12500 W/m2, and 18750 W/m2). The mean deviation of the predicted average PCM temperature was between 1.34 K-2.81 K for different cases. The maximum average temperature deviation of 5.45 K was observed for the 20 mm geometry at the highest heat flux test condition. The effects of natural convection were neglected in the model, but the predicted PCM temperature and energy storage still showed good agreement with the experimental data.

25 ENERGY STORAGE↗

Optimization of the pyrolysis process of empty fruit bunch (EFB) in a fixed-bed reactor through a central composite design (CCD)

The production of crude palm oil from the processing of palm fresh fruit bunches in the palm oil mills in Malaysia hs resulted in a huge quantity of empty fruit bunch (EFB) accumulated. The EFB was used as a feedstock in the pyrolysis process using a fixed-bed reactor in the present study. The optimization of process parameters such as pyrolysis temperature (factor A), biomass particle size (factor B) and holding time (factor C) were investigated through Central Composite Design (CCD) using Stat-Ease Design Expert software version 7 with bio-oil yield considered as the response. Twenty experimental runs were conducted. The results were completely analyzed by Analysis of Variance (ANOVA). The model was statistically significant. All factors studied were significant with p-values < 0.05. The pyrolysis temperature (factor A) was considered as the most significant parameter because its F-value of 116.29 was the highest. The value of R{sup 2} was 0.9564 which indicated that the selected factors and its levels showed high correlation to the production of bio-oil from EFB pyrolysis process. A quadratic model equation was developed and employed to predict the highest theoretical bio-oil yield. The maximum bio-oil yield of 46.2 % was achieved at pyrolysis temperature of 442.15 °C using the EFB particle size of 866 μm which corresponded to the EFB particle size in the range of 710–1000 μm and holding time of 483 seconds.

42 ENGINEERING↗

A unified non-equilibrium phase change model for injection flow modeling

The homogenous relaxation model (HRM) is one of the most widely used models to describe the liquid- gas phase transition. However, in its original formulation, it is unable to handle multispecies vapor-liquid equilibrium (VLE), which limits its applicability to single-component fluids. In this work, a unified non-equilibrium phase change model that considers the VLE of multicomponent mixtures is proposed building upon the HRM's structure. A time factor is introduced to mimic the effect of different phase change timescales due to different mechanisms, e.g., cavitation, flash-boiling, and evaporation. Here to assess the model's performance, computational fluid dynamics simulations of the internal and near-nozzle injection flow of the Engine Combustion Network's Spray G injector were performed using the nine-component PACE-20 fuel with both the unified model and the original HRM. The predicted fuel density in the near-nozzle region matched well with X-ray tomography measurements. The simulation results indicated that, whereas the HRM failed to capture the vaporization due to convective mixing between the fuel and ambient gas, the unified model performed well in predicting the mixing-driven vaporization and the corresponding evaporative cooling. Further comparisons using the nine-component fuel formula and a single-component fuel surrogate demonstrated the unified model's ability to predict preferential vaporization, which affects the predictions of local mixture composition and rate of vaporization. Finally, it is shown that the unified model is capable of representing multiple phase change mechanisms, and the relaxation time factor plays an important role in determining the degree of phase change due to the different mechanisms.

33 ADVANCED PROPULSION SYSTEMS↗

GPU Accelerated Sparse Cholesky Factorization

The solution of sparse symmetric positive definite linear systems is an important computational kernel in large-scale scientific and engineering modeling and simulation. We will solve the linear systems using a direct method, in which a Cholesky factorization of the coefficient matrix is performed using a right-looking approach and the resulting triangular factors are used to compute the solution. Sparse Cholesky factorization is compute intensive. In this work we investigate techniques for reducing the factorization time in sparse Cholesky factorization by offloading some of the dense matrix operations on a GPU. We will describe the techniques we have considered. We achieved up to 4x speedup compared to the CPU-only version.

Karsavuran, M Ozan↗

The design of a simulated in-line side-coupled 6 MV linear accelerator waveguide

Purpose: The design of a 3D in-line side-coupled 6 MV linac waveguide for medical use is given, and the effect of the side-coupling and port irises on the radio frequency (RF), beam dynamics, and dosimetric solutions is examined. This work was motivated by our research on a linac-MR hybrid system, where accurate electron trajectory information for a clinical medical waveguide in the presence of an external magnetic field was needed. Methods: For this work, the design of the linac waveguide was generated using the finite element method. The design outlined here incorporates the necessary geometric changes needed to incorporate a full-end accelerating cavity with a single-coupling iris, a waveguide-cavity coupling port iris that allows power transfer into the waveguide from the magnetron, as well as a method to control the RF field magnitude within the first half accelerating cavity into which the electrons from the gun are injected. Results: With the full waveguide designed to resonate at 2998.5{+-}0.1 MHz, a full 3D RF field solution was obtained. The accuracy of the 3D RF field solution was estimated through a comparison of important linac parameters (Q factor, shunt impedance, transit time factor, and resonant frequency) calculated for one accelerating cavity with the benchmarked program SUPERFISH. It was found that the maximum difference between the 3D solution and SUPERFISH was less than 0.03%. The eigenvalue solver, which determines the resonant frequencies of the 3D side-coupled waveguide simulation, was shown to be highly accurate through a comparison with lumped circuit theory. Two different waveguide geometries were examined, one incorporating a 0.5 mm first side cavity shift and another with a 1.5 mm first side cavity shift. The asymmetrically placed side-coupling irises and the port iris for both models were shown to introduce asymmetries in the RF field large enough to cause a peak shift and skewing (center of gravity minus peak shift) of an initially cylindrically uniform electron beam accelerating within the waveguide. The shifting and skewing of the electron beam were found to be greatest due to the effects of the side-coupling irises on the RF field. A further Monte Carlo study showed that this effect translated into a 1% asymmetry in a 40x40 cm{sup 2} field dose profile. Conclusions: A full 3D design for an in-line side-coupled 6 MV linear accelerator that emulates a common commercial waveguide has been given. The effect of the side coupling on the dose distribution has been shown to create a slight asymmetry, but overall does not affect the clinical applicability of the linac. The 3D in-line side-coupled linac model further provides a tool for the investigation of linac performance within an external magnetic field, which exists in an integrated linac-MR system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗