Search NASA⌕ Search

SEARCH · Search NASA

Results for “time horizons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimal Consumption in a Brownian Model with Absorption and Finite Time Horizon

We construct {epsilon}-optimal strategies for the following control problem: Maximize E[{integral}{sub [0,{tau})}e{sup -{beta}s} dC{sub s}+e{sup -{beta}{tau}}X{sub {tau}}] , where X{sub t}=x+{mu}t+{sigma}W{sub t}-C{sub t}, {tau}{identical_to}inf{l_brace}t>0|X{sub t}=0{r_brace} Logical-And T, T>0 is a fixed finite time horizon, W{sub t} is standard Brownian motion, {mu}, {sigma} are constants, and C{sub t} describes accumulated consumption until time t. It is shown that {epsilon}-optimal strategies are given by barrier strategies with time-dependent barriers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mean-Variance Hedging on Uncertain Time Horizon in a Market with a Jump

In this work, we study the problem of mean-variance hedging with a random horizon T∧τ, where T is a deterministic constant and τ is a jump time of the underlying asset price process. We first formulate this problem as a stochastic control problem and relate it to a system of BSDEs with a jump. We then provide a verification theorem which gives the optimal strategy for the mean-variance hedging using the solution of the previous system of BSDEs. Finally, we prove that this system of BSDEs admits a solution via a decomposition approach coming from filtration enlargement theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of modeled time horizon on quantifying the need for long-duration storage

Long-Duration Energy Storage (LDES) has gained interest due to its key role in attaining a decarbonized, low-cost, and stable grid driven by variable renewable electricity (VRE). Currently, there is a wide range of LDES technologies being developed to provide electricity with 8+ hours of consecutive discharge. However, current capacity expansion models used in long-term planning processes rarely consider low cost LDES as a candidate technology. If they do, the storage balancing horizon (SBH) of the model usually only considers non-consecutive 1-day periods that do not capture the potential of LDES to shift energy across multiple days or even seasons. Addressing these limitations in existing models, this work explores the ways in which the optimal energy storage changes when increasing the number of consecutive days in the SBH and how these changes will impact planners who are determining the future roles of energy storage. Our analysis uses SWITCH, an open-source capacity expansion model with a high spatial resolution for the entire Western Electricity Coordinating Council (WECC) in a zero-carbon scenario in 2050. We find that the number of consecutive days in the SBH changes both the total selected power and energy capacity of LDES when storage energy and power capacity overnight costs are $\$$13 USD/kWh (or less) and $113 USD/kW, respectively. We also find that the amount of required energy in storage to drive a future VRE-driven WECC grid ranges from 2.5 TWh to 16.0 TWh depending on the length of the SBH. The optimal storage duration (energy to power ratio) we obtain ranges from 10 h to 620 h among all the scenarios. Furthermore, depending on the storage cost assumption, we observe different charge/discharge patterns when varying the length of the SBH. Given our results, we anticipate that as more LDES technologies become commercially available, it will be critical to increase the length of the SBH to fully capture the benefits of LDES assets in long-term planning processes of high VRE-driven grids.

42 ENGINEERING↗

Water Stress on U.S. Power Production at Decadal Time Horizons

Thermoelectric power production at risk, owing to current and projected water scarcity and rising stream temperatures, is assessed for the contiguous United States at decadal scales. Regional water scarcity is driven by climate variability and change, as well as by multi-sector water demand. While a planning horizon of zero to about thirty years is occasionally prescribed by stakeholders, the challenges to risk assessment at these scales include the difficulty in delineating decadal climate trends from intrinsic natural or multiple model variability. Current generation global climate or earth system models are not credible at the spatial resolutions of power plants, especially for surface water quantity and stream temperatures, which further exacerbates the assessment challenge. Population changes, which are difficult to project, cannot serve as adequate proxies for changes in the water demand across sectors. The hypothesis that robust assessments of power production at risk are possible, despite the uncertainties, has been examined as a proof of concept. An approach is presented for delineating water scarcity and temperature from climate models, observations and population storylines, as well as for assessing power production at risk by examining geospatial correlations of power plant locations within regions where the usable water supply for energy production happens to be scarcer and warmer. Our analyses showed that in the near term, more than 200 counties are likely to be exposed to water scarcity in the next three decades. Further, we noticed that stream gauges in more than five counties in the 2030s and ten counties in the 2040s showed a significant increase in water temperature, which exceeded the power plant effluent temperature threshold set by the EPA. Power plants in South Carolina, Louisiana, and Texas are likely to be vulnerable owing to climate driven water stresses. In all, our analysis suggests that under various combinations of plausible climate change and population growth scenarios, anywhere between 4.5 and 9 quads of delivered electricity (from existing plants) would be generated in counties that are at risk of water scarcity and/or unacceptably high stream temperatures.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Capacity Market Model Considering Flexible Resource Requirements

With increasing installations of renewable generation, such as wind and solar, electric power systems need significant amounts of flexible resources to provide fast responses to mitigate the additional variability and uncertainty in generation. Current market designs have been shown to be insufficient in their mechanisms to compensate flexible resources for their services. Ancillary service markets can cover some of these costs, but they are likely not enough to attract additional flexible resources into the system. Although some independent system operators have started to design markets for flexible resources, their focus is on the short-term operating time horizon. This time horizon has significant real-time price uncertainties for flexible resources and might provide insufficient motivation for them to participate in the market. The capacity market has traditionally been the incentive to invest in new generation resources. Therefore, if a system needs new flexible resources, it is necessary to introduce flexible resource requirements into the capacity market to directly attract more flexible resource investment. This paper proposes a simplified capacity market model including flexible resource requirements. Case studies are examined to validate the proposed method.

17 WIND ENERGY↗

Capacity Market Model Considering Flexible Resource Requirements: Preprint

With increasing installations of renewable generation, such as wind and solar, electric power systems need significant amounts of flexible resources to provide fast responses to mitigate the additional variability and uncertainty in generation. Current market designs have been shown to be insufficient in their mechanisms to compensate flexible resources for their services. Ancillary service markets can cover some of these costs, but they are likely not enough to attract additional flexible resources into the system. Although some independent system operators have started to design markets for flexible resources, their focus is on the short-term operating time horizon. This time horizon has significant real-time price uncertainties for flexible resources and might provide insufficient motivation for them to participate in the market. The capacity market has traditionally been the incentive to invest in new generation resources. Therefore, if a system needs new flexible resources, it is necessary to introduce flexible resource requirements into the capacity market to directly attract more flexible resource investment. This paper proposes a simplified capacity market model including flexible resource requirements. Case studies are examined to validate the proposed method.

17 WIND ENERGY↗

Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits

The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorized Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes included increasing the time horizon beyond 1,050 years (yr), and using the radionuclide concentrations provided by the DOE-PPPO as inputs into the codes. The deterministic peak doses were evaluated within time horizons of 70 yr (for the Landfill Worker and Trespasser), 1,050 yr, 10,000 yr and 100,000 yr (for the Resident Farmer [onsite], Resident Gardener, Recreational User, Outdoor Worker and Offsite Resident Farmer) at the request of the DOE-PPPO. The time horizons of 10,000 yr and 100,000 yr were used at the request of the DOE-PPPO for informational purposes only. The probabilistic peak of the mean dose assessment was performed for the Offsite Resident Farmer using Technetium-99 (Tc-99) and a time horizon of 1,050 yr. The results of the deterministic analyses indicate that among all receptors and time horizons evaluated, the highest projected dose, 2,700 mrem/yr, occurred for the Resident Farmer (onsite) at 12,773 yr. The exposure pathways contributing to the peak dose are ingestion of plants, external gamma, and ingestion of milk, meat and soil. However, this receptor is considered an implausible receptor. The only receptors considered plausible are the Landfill Worker, Recreational User, Outdoor Worker and the Offsite Resident Farmer. The maximum projected dose among the plausible receptors is 220 mrem/yr for the Outdoor Worker and it occurs at 19,045 yr. The exposure pathways contributing to the dose for this receptor are external gamma and soil ingestion. The results of the probabilistic peak of the mean dose analysis for the Offsite Resident Farmer indicate that the average (arithmetic mean) of the peak of the mean doses for this receptor is 0.98 mrem/yr and it occurs at 1,050 yr. This dose corresponds to Tc-99 within the time horizon of 1,050 yr.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resilience Metrics and Framework for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. We propose a three-tiered approach for the resilience framework. At the top level, we consider the time horizons on which resilience will be evaluated and executed. At the middle level, we consider the core functions of resilience, which span across the time horizons. At the lower level, we consider the process steps that correspond to implementing practices for resilience in each of the core functions. The framework considers three time horizons in order to enable organizations to assess and improve their system’s resilience throughout its lifecycle. We call these time horizons the planning, operational, and future stages. The planning stage uses organizational needs and current system evaluation to prepare for potential hazards. The operational stage seeks to execute responses to hazards as prudently and efficiently as possible to maintain system resilience. The future stage seeks to improve on current system resilience and feeds back into the planning stage to promote continuous improvement. While all three time horizons are important when considering a specific topic, the planning and evaluation phase (i.e., what is done in advance of the event) is critical in defining a system’s resilience characteristics and in outlining how a system responds to an event. This framework intentionally emphasizes the planning stage to highlight the overarching emphasis of this effort, not to imply that the other two time-related horizons (i.e., operational and change the future) are less important. The core functions in the framework are identify, prepare, detect, adapt, and recover. These five functions stem from a rigorous analysis of definitions used across the industry, and they represent the core capabilities that an organization must have to enable lifecycle resilience. Within each core function, process steps are described that help walk an organization through the information gathering, evaluation, decision-making, and implementation processes they will need to ensure their resilience goals are maintained throughout the system and the system lifecycle. Also highlighted in the figure is the concept that a resilience framework should be cyclical in nature. Because a system’s resilience is based on finite resources and time, it must continually evolve through this framework’s risk management and capital investment steps at an appropriate level of scope and pace.

17 WIND ENERGY↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of model improvements on 80 m wind speeds during the second Wind Forecast Improvement Project (WFIP2)

Abstract. During the second Wind Forecast Improvement Project (WFIP2; October 2015–March 2017, held in the Columbia River Gorge and Basin area of eastern Washington and Oregon states), several improvements to the parameterizations used in the High Resolution Rapid Refresh (HRRR – 3 km horizontal grid spacing) and the High Resolution Rapid Refresh Nest (HRRRNEST – 750 m horizontal grid spacing) numerical weather prediction (NWP) models were tested during four 6-week reforecast periods (one for each season). For these tests the models were run in control (CNT) and experimental (EXP) configurations, with the EXP configuration including all the improved parameterizations. The impacts of the experimental parameterizations on the forecast of 80 m wind speeds (wind turbine hub height) from the HRRR and HRRRNEST models are assessed, using observations collected by 19 sodars and three profiling lidars for comparison. Improvements due to the experimental physics (EXP vs. CNT runs) and those due to finer horizontal grid spacing (HRRRNEST vs. HRRR) and the combination of the two are compared, using standard bulk statistics such as mean absolute error (MAE) and mean bias error (bias). On average, the HRRR 80 m wind speed MAE is reduced by 3 %–4 % due to the experimental physics. The impact of the finer horizontal grid spacing in the CNT runs also shows a positive improvement of 5 % on MAE, which is particularly large at nighttime and during the morning transition. Lastly, the combined impact of the experimental physics and finer horizontal grid spacing produces larger improvements in the 80 m wind speed MAE, up to 7 %–8 %. The improvements are evaluated as a function of the model's initialization time, forecast horizon, time of the day, season of the year, site elevation, and meteorological phenomena. Causes of model weaknesses are identified. Finally, bias correction methods are applied to the 80 m wind speed model outputs to measure their impact on the improvements due to the removal of the systematic component of the errors.

17 WIND ENERGY↗

Evaluation of Horizon of Viability Optimization Engine for Sustained Power to Critical Infrastructure: Preprint

In the aftermath of increasingly frequent catastrophic events, a typical scenario is Critical Infrastructure (CI) units being supported by available backup sources with a weak power grid that can be intermittent or absent. Such a scenario is significantly challenging in the sense of reliable supply of power to CI units. In this article, an intelligent optimization scheme termed as Horizon of Viability (HoV) engine is developed to guarantee the viability of a sustained reliable supply of power to the CI units over a time-horizon. The proposed HoV engine generates a cost-optimal portfolio of the locally available generation sources and the loads over a time horizon using a mixed-integer convex programming problem. A Controller hardware-in-the-loop (CHIL) platform is developed to evaluate the control performance of the HoV engine. The experimental results corroborates the efficacy in maintaining the viability of the CI units after a grid interruption event. Further, the proposed HoV optimization scheme performs better compared to existing net-load management schemes in the literature.

disaster resiliency↗

Potential Adoption and Benefits of Co-Optimized Multimode Engines and Fuels for U.S. Light-Duty Vehicles

Exploring a diverse portfolio of technologies for decarbonization is crucial to understanding the potential impacts of different technological solutions and their associated environmental implications. Using high-octane, high-sensitivity biofuel blends in co-optimized multimode engines can increase engine efficiency and reduce vehicle emissions. Here, the multimode engine research focuses on the benefits of light-duty vehicle engines, which can operate in multiple modes depending on the vehicle's load. Low-temperature combustion can improve efficiency and reduce emissions (such as those from oxides of nitrogen and particulate matter) during low-load operation, while spark ignition performance is maintained in high-load operation. These advanced engines can be optimized to run on blends of biobased fuels. This analysis models scenarios for potential market adoption of co-optimized multimode vehicles fueled by three different bioblendstocks: ethanol, isopropanol, and isobutanol. An integrated modeling approach is used to forecast the energy and environmental impacts of the deployment of co-optimized multimode vehicles and fuels in the light-duty sector over the 2020-to-2050 time horizon. The multidisciplinary approach combines vehicle sales modeling, system dynamics modeling of the biorefining industry, and life cycle assessment to estimate the emissions and energy benefits. The models consider market forces such as consumer preferences for vehicle attributes, biofuel supply and demand dynamics subject to biorefinery capacity build-out and bioresource constraints, and forecasted changes to the U.S. bulk energy system over time. Market adoption of co-optimized vehicles is evaluated across a wide parameter space for incremental vehicle cost and engine efficiency improvement. This analysis reveals that the deployment of co-optimized multimode fuels and vehicles results in up to a 5% reduction in annual sector-wide life cycle greenhouse gas (GHG) emissions by 2050, relative to a business-as-usual scenario, but is also indicates environmental trade-offs, such as higher life cycle water-use. Emission benefits could potentially increase beyond 2050, as the new technologies penetrate the market and gain a foothold. Results also show that, under certain circumstances, vehicles with engines co-optimized for use with high-octane, high-sensitivity biofuel blends can be cost-competitive with conventional gasoline, while reducing GHG emissions. Our modeling results indicate that co-optimized multimode fuels and engines can be strategically leveraged in tandem with electrification to decarbonize the light-duty sector. Co-optimized vehicles could play a role in the early years of the time horizon, while electric vehicles (EVs) could become more competitive in the later years, highlighting the complementary benefits of these technologies for GHG reductions.

Oke, Doris↗

Use of Physics to Improve Solar Forecast: Physics-Informed Persistence Models for Simultaneously Forecasting GHI, DNI, and DHI

Observation-based statistical models have been widely used in forecasting solar energy; however, existing models often lack a clear relation to physics and are limited largely to global horizontal irradiance (GHI) forecasts over relatively short time horizons (< 1 hour). Incorporating physics into observation-based models, increasing forecast time horizons and developing a model system for forecasting not only GHI but also direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) remain challenging, especially under cloudy conditions because of complex cloud-radiation interactions. This work attempts to address these challenges by developing a hierarchy of four new physics-informed persistence models that can be used to simultaneously forecast GHI, DNI and DHI. The decade-long measurements (1998 to 2014) at the U.S. Department of Energy's Atmospheric Radiation Measurement (ARM)'s Southern Great Plains (SGP) Central Facility site are used to evaluate the performance of the new models. Overall, the results show that the new physics-informed forecast models generally outperform the simple and smart persistence models, and improve the forecast accuracy at lead times from 1.25 hours up to 6 hours. Further analysis reveals that the forecast error is highly related to the error and temporal variability of the assumed cloud predictor. The best model for forecasting different radiative components can be explained by the relationship between solar irradiances and cloud properties.

54 ENVIRONMENTAL SCIENCES↗

Portfolio Optimization in a Semi-Markov Modulated Market

We address a portfolio optimization problem in a semi-Markov modulated market. We study both the terminal expected utility optimization on finite time horizon and the risk-sensitive portfolio optimization on finite and infinite time horizon. We obtain optimal portfolios in relevant cases. A numerical procedure is also developed to compute the optimal expected terminal utility for finite horizon problem.

97 MATHEMATICS AND COMPUTING↗

Construction of Discrete Time Shadow Price

In the paper expected utility from consumption over finite time horizon for discrete time markets with bid and ask prices and strictly concave utility function is considered. The notion of weak shadow price, i.e. an illiquid price, depending on the portfolio, under which the model without bid and ask price is equivalent to the model with bid and ask price is introduced. Existence and the form of weak shadow price is shown. Using weak shadow price usual (called in the paper strong) shadow price is then constructed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Agent-based modeling for multimodal transportation of CO 2 for carbon capture, utilization, and storage: CCUS-agent

Here, to understand the system-level interactions between the entities in Carbon Capture, Utilization, and Storage (CCUS), an agent-based foundational modeling tool, CCUS-Agent, is developed for a large-scale study of transportation flows and infrastructure in the United States. Key features of the tool include (i) modular design, (ii) multiple transportation modes, (iii) capabilities for extension, and (iv) testing against various system components and networks of small and large sizes. Five matching algorithms for CO 2 supply agents (e.g., powerplants and industrial facilities) and demand agents (e.g., storage and utilization sites) are explored: Most Profitable First Year (MPFY), Most Profitable All Years (MPAY), Shortest Total Distance First Year (SDFY), Shortest Total Distance All Years (SDAY), and Shortest distance to long-haul transport All Years (ACAY). Before matching, the supply agent, demand agent, and route must be available, and the connection must be profitable. A profitable connection means the supply agent portion of revenue from the 45Q tax credit must cover the supply agent costs and all transportation costs, while the demand agent revenue portion must cover all demand agent costs. A case study employing over 5500 supply and demand agents and multimodal CCUS transportation infrastructure in the contiguous United States is conducted. The results suggest that it is possible to capture over 9 billion tonnes (GT) of CO 2 from 2025 to 2043, which will increase significantly to 22 GT if the capture costs are reduced by 40 %. The MPFY and SDFY algorithms capture more CO 2 earlier in the time horizon, while the MPAY and SDAY algorithms capture more later in the time horizon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗