Search NASA⌕ Search

SEARCH · Search NASA

Results for “time of flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Small High Endurance Aircraft Technology (sHEAT) - Application of Solid-State Hydrogen Storage to Extend Flight Time of sUAS

Savannah River National Laboratory (SRNL) proposed a study to The Department of Homeland Security (DHS) Science & Technology Directorate (S&T) to investigate the possibility of extending the flight time of small-scale Unmanned Aerial Vehicles (UAVs) using aluminum hydride (AlH 3 or alane) to power a hydrogen fuel cell. Alane is a solid-state hydrogen storage material with greater volumetric energy density than compressed hydrogen and much greater energy density than lithium batteries. UAVs typically use lithium-polymer and lithium-ion batteries for flight, but lithium batteries have not provided a substantial increase in flight time or range since their wide acceptance in the unmanned aircraft market. Several DHS agencies would benefit greatly from extended flight times and ranges for UAS platforms, so experimenting with new types of power sources could provide significant improvement in these important areas of research for DHS S&T.

08 HYDROGEN↗

Time-of-flight vs time-of-arrival in neutron spectroscopic measurements for high energy density plasmas

The neutron time-of-flight (nToF) diagnostic technique has a lengthy history in Inertial Confinement Fusion (ICF) and High Energy Density (HED) Science experiments. Its initial utility resulted from the simple relationship between the full width half maximum of the fusion peak signal in a distant detector and the burn averaged conditions of an ideal plasma producing the flux [Lehner and Pohl, Z. Phys. 207, 83–104 (1967)]. More recent precision measurements [Gatu-Johnson et al., Phys. Rev. E 94(8), 021202 (2016)] and theoretical studies [Munro, Nucl. Fusion 56, 035001 (2016)] have shown the spectrum to be more subtle and complicated, driving the desire for an absolute calibration of the spectrum to disambiguate plasma dynamics from the conditions producing thermonuclear reactions. In experiments where the neutron production history is not well measured, but the neutron signal is preceded by a concomitant flux of photons, the spectrum can be in situ calibrated using a set of collinear detectors to obtain a true “time-of-flight” measurement. This article presents the motivation and overview of this technique along with estimates of the experimental precision needed to make useful measurements in existing and future nToF systems such as the pulsed power Z-machine located in Albuquerque, NM, at Sandia National Laboratories.

Fusion experiments↗

Time-of-Flight energy measurements with BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighboring Beam Position Monitors (BPMs). This report presents estimations on implementation of such a procedure at PIP-II H- linac being constructed at Fermilab. In part, the case when the flight time between BPMs is larger than the period of BPM frequency is considered in detail. When the absolute BPM phase calibration is not available, the BPM phase information can be used to trace deviations of the beam energy from the desired value. Such “energy deviation” parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501↗

Time-of-Flight Energy Measurements With BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed at Fermilab. The case when the flight time between BPMs is longer than the period of BPM frequency is considered in more detail. When absolute BPM phase calibration is not available, the BPM phase information can be used to track deviations of the beam energy from the de-sired value. Such energy deviation parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander V. [Fermilab] (ORCID:00000001↗

Design of a multi-detector, single line-of-sight, time-of-flight system to measure time-resolved neutron energy spectra

In the dynamic environment of burning, thermonuclear deuterium–tritium plasmas, diagnosing the time-resolved neutron energy spectrum is of critical importance. Strategies exist for this diagnosis in magnetic confinement fusion plasmas, which presently have a lifetime of ~10 12 longer than inertial confinement fusion (ICF) plasmas. In this work, we present a novel concept for a simple, precise, and scale-able diagnostic to measure time-resolved neutron spectra in ICF plasmas. The concept leverages general tomographic reconstruction techniques adapted to time-of-flight parameter space, and then employs an updated Monte Carlo algorithm and National Ignition Facility-relevant constraints to reconstruct the time-evolving neutron energy spectrum. Reconstructed spectra of the primary 14.028 MeV n DT peak are in good agreement with the exact synthetic spectra. The technique is also used to reconstruct the time-evolving downscattered spectrum, although the present implementation shows significantly more error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A broadband wavelet implementation for rapid ultrasound pulse-echo time-of-flight measurements

A broadband wavelet approach to ultrasonic pulse-echo time-of-flight measurements is described. The broadband approach significantly reduces the time required for frequency-dependent pulse-echo measurements, enabling studies of dynamic systems ranging from biological systems to solid-state phase transitions. The described broadband approach is demonstrated in parallel with the more traditional frequency stepping approach to perform ultrasound time-of-flight measurements inside a large volume Paris-Edinburgh press in-situ at a synchrotron source. The broadband wavelet data acquisition process was found to be 1-2 orders of magnitude faster than the steppedfrequency approach, with no compromise in data quality or determined results.

47 OTHER INSTRUMENTATION↗

Neutron time-of-flight detectors (nTOF) used at Sandia’s Z-Machine

Neutron time-of-flight (nTOF) detectors have been used on Sandia National Laboratories’ Z-Machine for inertial confinement fusion and magnetized liner fusion experiments to infer physics parameters including the apparent fuel-ion temperature, neutron yield, the magnetic-radius product (BR), and the liner rho-r. Single-paddle, dual-paddle, and co-axial scintillation nTOF detectors are used in axial lines-of-sight (LOS) and LOS that are 12° from the midplane. Detector fabrication, characterization, and calibration are discussed.

Chandler, G. A. (ORCID:0000000219640927)↗

Heat-induced drift reduction of time of flight in fused quartz acoustic waveguides via annealing process

High temperature structural acoustic sensors play an important role in many applications. Fused quartz waveguide is a popular choice due to its resistance to harsh environments and its convenience of modification. However, time of flight between pulse and echo, which is widely used in these sensors, tends to encounter drifts in fast temperature changing process even after temperature returns to initial value. In this article, different annealing process are performed for a special modified fused quartz waveguide with a sensor node. Annealing treatment is found able to reduce the drift when the waveguide undergoes a sudden temperature spike to 1000 °C at 500 kHz operating acoustic frequency, and the best annealing condition could make the drift one magnitude smaller. A following temperature test up to 1000 °C shows consistent measurement readings.

Hileman, Zachary (ORCID:0000000226529274)↗

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

A magnetic particle time-of-flight (MagPTOF) diagnostic for measurements of shock and compression-bang time at the NIF [National Ignition Facility]

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using DHe-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase DHe-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock and compression-bang times in DHe-filled surrogate implosions at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The CLAS12 Forward Time-of-Flight system

The Forward Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system is positioned at distances in the range from 6.2 m to 7.2 m from the beam–target interaction point and spans laboratory polar angles from 5 deg → 45 deg and nearly the full azimuth. The system consists of 540 individual scintillation counters with double-ended readout that range in length from 17 cm to 426 cm of discrete widths of 6 cm, 15 cm, and 22 cm, and of discrete thicknesses of 5 cm and 6 cm. We see the effective counter time resolution for passing charged particles varies from 50 ps for the shortest counters at small angles to 200 ps for the longest counters at large angles. The detectors are part of the forward-angle particle identification system for CLAS12 during offline event reconstruction and are a component of the online data acquisition trigger to select final state event topologies with forward-going charged particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Central Time-of-Flight system

The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.

47 OTHER INSTRUMENTATION↗

Proof-of-concept of a neutron time-of-flight ellipsoidal detector

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

Jeet, J. (ORCID:0000000291091563)↗