Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing jitter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Minimizing Timing Jitter’s Impact on Ground-Penetrating Radar Array Coupling Signals

This article presents a novel investigation into the effect of receiver timing jitter on the quality of imaging of ground-penetrating radar systems. We explicitly show the impact of timing jitter throughout an entire example processing pipeline. The process of coupling removal in systems whose receivers have a random Gaussian-distributed jitter with a high standard deviation leaves randomly distributed residue in the radar image. This residue, called jitter-induced coupling noise, extends even into the expected target domain which may cause false alarms. This residue approximately follows a sum of Gaussian and Gamma distributions based on the higher order derivatives of the coupling signal. Once migrated to create an image, the coupling residue is best described by a Weibull distribution. We show that simple filtering does not remove enough residue and propose two preventative design specifications called the linear slope and migrated probability specifications. Antenna and system designers should use these specifications to assess the true severity of coupling signals in a given jitter environment.

47 OTHER INSTRUMENTATION↗

Initial observations of the femtosecond timing jitter at the European XFEL

Intense, ultrashort, and high-repetition-rate X-ray pulses, combined with a femtosecond optical laser, allow pump-probe experiments with fast data acquisition and femtosecond time resolution. However, the relative timing of the X-ray pulses and the optical laser pulses can be controlled only to a level of the intrinsic error of the instrument which, without characterization, limits the time resolution of experiments. This limitation inevitably calls for a precise determination of the relative arrival time, which can be used after measurement for sorting and tagging the experimental data to a much finer resolution than it can be controlled to. The observed root-mean-square timing jitter between the X-ray and the optical laser at the SPB/SFX instrument at European XFEL was 308 fs. This first measurement of timing jitter at the European XFEL provides an important step in realizing ultrafast experiments at this novel X-ray source. Lastly, a method for determining the change in the complex refractive index of samples is also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond Compression Dynamics and Timing Jitter Suppression in a THz-driven Electron Bunch Compressor

Herein we present the first demonstration of THz driven bunch compression and timing stabilization of a relativistic electron beam. Quasi-single-cycle strong field THz radiation is used in a shorted parallel-plate structure to compress a few-fC beam with 2.5 MeV kinetic energy by a factor of 2.7, producing a 39 fs rms bunch length and a reduction in timing jitter by more than a factor of 2 to 31 fs rms. This THz driven technique offers a significant improvement to beam performance for applications like ultrafast electron diffraction, providing a critical step towards unprecedented timing resolution in ultrafast sciences, and other accelerator applications using femtosecond-scale electron beams.

43 PARTICLE ACCELERATORS↗

Compact, All-PM Fiber Integrated and Alignment-Free Ultrafast Yb:Fiber NALM Laser With Sub-Femtosecond Timing Jitter

We report a simple and compact design of a dispersion compensated mode-locked Yb:fiber oscillator based on a nonlinear amplifying loop mirror (NALM). The fully polarization maintaining (PM) fiber integrated laser features a chirped fiber Bragg grating (CFBG) for dispersion compensation and a fiber integrated compact non-reciprocal phase bias device, which is alignment-free. The main design parameters were determined by numerically simulating the pulse evolution in the oscillator and by analyzing their impact on the laser performance. Experimentally, we achieved an 88 fs compressed pulse duration with sub-fs timing jitter at 54 MHz repetition rate and 51 mW of output power with 5.5×10 -5 [20 Hz, 1 MHz] integrated relative intensity noise (RIN). Furthermore, we demonstrate tight phase-locking of the laser's carrier-envelope offset frequency ( fceo ) to a stable radio frequency (RF) reference and of one frequency comb tooth to a stable optical reference at 291 THz.

47 OTHER INSTRUMENTATION↗

Development of a Small-Pixel Ir-TES for Optical Applications

We designed and fabricated a photon-number-resolving detector based on an iridium (Ir) transition-edge sensors (TES) with small timing jitter time for coherent optical communication. The current–voltage relationship of the small Ir-TES, with an effective area of 7 μm × 7 μm, was measured, and its electrothermal feedback operation was confirmed. This device had a transition temperature of 280 mK, which is higher than that of bulk Ir, because of the wide contact area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Pseudo-spark switch (PSS) characteristics under different operation conditions

The present paper concentrates on the characteristics of the pseudospark switch (PSS) designed in a previous work. The special characteristics of PSS make it a replacement for other high voltage switches such as thyratrons and ordinary high-pressure spark gaps. PSS is characterized by short rise time and small jitter time. The pseudo park chamber consists of two hollow cylindrical electrodes made of a stainless steel material (type 306L) separated by an insulator. The insulator used in our design is a glazed ceramic 70 mm in diameter and 3.5 mm in thickness. A PSS with an anode voltage of 29.2 kV, and a current of 3.6 kA and 11 ns rise time was achieved and used successfully at a repetition rate of about 2.2 kHz. A simple trigger circuit designed, built, and used effectively reaching more than 1.56 kV trigger pulse which is sufficient to ignite the argon gas inside the cathode to cause a breakdown. A non-inductive dummy load is designed to be a new technique to find the accurate value of the PSS inductance. A jitter time of ±10 ns pulses is observed to occur in a reliable manner for more than 6 h of continuous operation. In this research, the important parameters of this switch like rise time, peak current, and anode voltage were studied at various values of charging capacitance. The lifetime of this system is depending on the kind of the electrode material and on the type of insulation material in the main gap of the pseudospark switch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Longitudinal Beam Parameter Tolerances of NSLS-II

Similar to the transverse phase space, the beam parameters in the longitudinal phase space must also be monitored and controlled. In the longitudinal phase space the fundamental parameters are: bunch arrival time(or the corresponding RF phase), average momentum, bunch length, and momentum spread. These parameters are usually perturbed by the various noises in a real machine. The noises could excite longitudinal bunch motion, seen by the users as timing jitter, intensity and wavelength variation, and transverse position shift et al. The longitudinal oscillations also cause longitudinal emittance growth, therefore lengthen the bunch and increase the momentum spread, and eventually decrease the brightness. As a rule of thumb for the tolerances, either transverse or longitudinal, the perturbation caused by the noises should not result in a decrease of brightness by more than 10%. The users are concerned about the longitudinal beam parameters in several ways. First the timing jitter affects the timing-dependent experiments. Even though a photo-diode detection system is usually used to to determine the arrival time, the bandwidth is only about 1 kHz. The users from this category ask for a timing jitter tolerance to be 5% of the RMS bunch length over the frequency range from 500 Hz to 50 kHz. This corresponds to a phase error of Δφ = 1.6 mr or 0.1° for a 10 ps bunch with a 500 MHz rf system.

47 OTHER INSTRUMENTATION↗

A sub-5 ps jitter time-to-digital converter ASIC with back-gate delay tuning in 22 nm CMOS

We present the design of a Time-to-Digital Converter (TDC) ASIC together with performance characterization results at cryogenic temperature (6-8 K), and at room temperature using emulated Low-Gain Avalanche Detector (LGAD) signals. The TDC design uses a two-step architecture with a ring-oscillator based counter and a Vernier delay line fine TDC. The TDC is implemented in an FD-SOI process, and back-gate tuning is used not only to correct threshold variation due to cryogenic operation, but also as a novel way to tune TDC delay elements with very little overhead. Using this technique, we demonstrate a design with very low power (0.5 mW) and area (0.003 mm 2 ). We present test results using the Fermilab Constant Fraction Discriminator (FCFD) ASIC to produce discriminated signals from an internal charge injection mechanism that mimics the waveform and signal amplitude of minimum ionizing particles impinging on LGAD sensors. We characterize the time precision of the full system and verify that the TDC ASIC contributes a negligible amount to the total system time precision, fully consistent with the expected jitter contribution of less than 5 ps. In conclusion, the results presented here demonstrate the utility of our TDC for applications in physics and quantum communications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Optimization of NSLS-II Dynamic Aperture and Injection Transient (Facility Improvement Project)

The Facility Improvement Project (FIP) “Methods of online optimization of NSLS-II storage ring concurrent with user operations” proposed and approved in 2018 is now complete. The first goal is the online optimization of nonlinear beam dynamics to increase the beam lifetime and injection efficiency. We have developed a model-independent optimization technique using advanced algorithms. Using this technique, we increased the NSLS-II dynamic aperture by 20% and reduced the amplitude-dependent tune shift by a factor of two. We applied sextupole optimization to the new high-chromaticity lattice, which has been developed to improve the beam stability and to increase the single-bunch beam intensity. We were able to double the injection efficiency and exceed 90%. The second goal of this project is to provide the top-off injection with minimized perturbations of the beamline user operations. To achieve the transparent injection, we optimize the matching of four storage ring injection kickers reducing the perturbation of the stored beam orbit. The first application of the online optimization resulted in a reduction of the amplitude of residual beam oscillation by a factor of six, from 1300 μm down to 200 μm. Further improvement was limited by the timing jitter of the trigger boards. Then, we replaced all trigger boards with a new design and reduced the timing jitter by a factor of five, from 5 ns down to 1 ns. This upgrade resulted in the injection transient reduction from 200 μm to 120 μm. To optimize the full set of kicker parameters, including the trigger timing, amplitude, and pulse width, we upgraded all kicker power supplies with the capability of tunable waveform width. As a result, we have reduced the injection transient to the limit of 60 μm.

43 PARTICLE ACCELERATORS↗

Jitter-correction for IR/UV-XUV pump-probe experiments at the FLASH free-electron laser

In pump-probe experiments employing a free-electron laser (FEL) in combination with a synchronized optical femtosecond laser, the arrival-time jitter between the FEL pulse and the optical laser pulse often severely limits the temporal resolution that can be achieved. Here, we present a pump-probe experiment on the UV-induced dissociation of 2,6-difluoroiodobenzene C 6 H 3 F 2 I) molecules performed at the FLASH FEL that takes advantage of recent upgrades of the FLASH timing and synchronization system to obtain high-quality data that are not limited by the FEL arrival-time jitter. Here, we discuss in detail the necessary data analysis steps and describe the origin of the time-dependent effects in the yields and kinetic energies of the fragment ions that we observe in the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulations of time-of-flight PET with double-ended readout: calibration, coincidence resolving times and statistical lower bounds

Here, this paper demonstrates through Monte Carlo simulations that a practical positron emission tomograph with (1) deep scintillators for efficient detection, (2) double-ended readout for depth-of-interaction information, (3) fixed-level analog triggering, and (4) accurate calibration and timing data corrections can achieve a coincidence resolving time (CRT) that is not far above the statistical lower bound. One Monte Carlo algorithm simulates a calibration procedure that uses data from a positron point source. Annihilation events with an interaction near the entrance surface of one scintillator are selected, and data from the two photodetectors on the other scintillator provide depth-dependent timing corrections. Another Monte Carlo algorithm simulates normal operation using these corrections and determines the CRT. A third Monte Carlo algorithm determines the CRT statistical lower bound by generating a series of random interaction depths, and for each interaction a set of random photoelectron times for each of the two photodetectors. The most likely interaction times are determined by shifting the depth-dependent probability density function to maximize the joint likelihood for all the photoelectron times in each set. Example calculations are tabulated for different numbers of photoelectrons and photodetector time jitters for three 3 × 3 × 30 mm 3 scintillators: Lu 2 SiO 5 :Ce,Ca (LSO), LaBr 3 :Ce, and a hypothetical ultra-fast scintillator. To isolate the factors that depend on the scintillator length and the ability to estimate the DOI, CRT values are tabulated for perfect scintillator-photodetectors. For LSO with 4000 photoelectrons and single photoelectron time jitter of the photodetector J = 0.2 ns (FWHM), the CRT value using the statistically weighted average of corrected trigger times is 0.098 ns FWHM and the statistical lower bound is 0.091 ns FWHM. For LaBr 3 :Ce with 8000 photoelectrons and J = 0.2 ns FWHM, the CRT values are 0.070 and 0.063 ns FWHM, respectively. For the ultra-fast scintillator with 1 ns decay time, 4000 photoelectrons, and J = 0.2 ns FWHM, the CRT values are 0.021 and 0.017 ns FWHM, respectively. Lastly, the examples also show that calibration and correction for depth-dependent variations in pulse height and in annihilation and optical photon transit times are necessary to achieve these CRT values.

60 APPLIED LIFE SCIENCES↗

Monte Carlo calculations of PET coincidence timing: single and double-ended readout

We present Monte Carlo computational methods for estimating the coincidence resolving time (CRT) of scintillator detector pairs in positron emission tomography (PET) and present results for Lu 2 SiO 5 : Ce (LSO), LaBr 3 : Ce, and a hypothetical ultra-fast scintillator with a 1 ns decay time. The calculations were applied to both single-ended and double-ended photodetector readout with constant-fraction triggering. They explicitly include (1) the intrinsic scintillator properties (luminosity, rise time, decay time, and index of refraction), (2) the exponentially distributed depths of interaction, (3) the optical photon transport efficiency, delay, and time dispersion, (4) the photodetector properties (fill factor, quantum efficiency, transit time jitter, and single electron response), and (5) the determination of the constant fraction trigger level that minimizes the CRT. The calculations for single-ended readout include the delayed photons from the opposite reflective surface. The calculations for double-ended readout include (1) the simple average of the two photodetector trigger times, (2) more accurate estimators of the annihilation photon entrance time using the pulse height ratio to estimate the depth of interaction and correct for annihilation photon, optical photon, and trigger delays, and (3) the statistical lower bound for interactions at the center of the crystal. For time-of-flight (TOF) PET we combine stopping power and TOF information in a figure of merit equal to the sensitivity gain relative to whole-body non-TOF PET using LSO. For LSO crystals 3 mm × 3 mm × 30 mm, a decay time of 37 ns, a total photoelectron count of 4000, and a photodetector with 0.2 ns full-width at half-maximum (fwhm) timing jitter, single-ended readout has a CRT of 0.16 ns fwhm and double-ended readout has a CRT of 0.111 ns fwhm. For LaBr 3 : Ce crystals 3 mm × 3 mm × 30 mm, a rise time of 0.2 ns, a decay time of 18 ns, and a total of 7600 photoelectrons the CRT numbers are 0.14 ns and 0.072 ns fwhm, respectively. For a hypothetical ultra-fast scintillator 3 mm × 3 mm × 30 mm, a decay time of 1 ns, and a total of 4000 photoelectrons, the CRT numbers are 0.070 and 0.020 ns fwhm, respectively. Over a range of examples, values for double-ended readout are about 10% larger than the statistical lower bound.

Monte Carlo↗

Lasing dynamics of diode-pumped Yb – Er laser with a passive Q switch exposed to high-power external light

The temporal dynamics of diode-side-pumped Yb – Er laser, with a passive Co{sup 2+} : MgAl{sub 2}O{sub 4} Q switch illuminated by a light beam (total fluence of 0.15 – 0.16 J cm{sup −2}) from a semiconductor pulsed module, is investigated. It is shown that, using this external illumination, one can change the lasing onset delay and the time jitter ΔT{sub gi}. The dependence of ΔT{sub gi} on the interval between the instant of switching the illumination module on and the lasing peak position t{sub i} has a minimum at |t{sub i}| ≈ 10 μs. The decrease in ΔT{sub gi} with a change in |t{sub i}| from 90 to 10 μs indicates that instant of lasing peak occurrence for the Yb – Er laser is partially controlled by the pulse from the highly stable semiconductor module. If |t{sub i}| < 10 μs, the enhanced luminescence fluence in the cavity of Yb – Er laser exceeds 0.16 J cm{sup −2}; the light beam from the module does not affect much the lasing process in the ytterbium – erbium laser; and, as a consequence, the time jitter recovers the initial value. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗