Search NASA⌕ Search

SEARCH · Search NASA

Results for “titration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Establishing In-House Titration Capabilities: Part I. Hydroxyl Group Titration through Acetic Anhydride Acetylation

This lessons learned document provides a detailed analysis of the hydroxy termination titration methods employed for determining hydroxyl group content in various chemical samples. The primary focus is on the evaluation of techniques such as ASTM E222 and their practical applications in laboratory settings. Through examination of method selection, sample preparation, and titration execution, key insights have been identified that enhance the accuracy and reliability of results. Notable findings include the advantages of using pressure bottle methods for improved heating uniformity and reduced solvent loss, as well as the challenges associated with endpoint detection in dark-colored solutions. Recommendations for alternative sampling and titration techniques are proposed to address these challenges. This document serves as a valuable resource for enhancing the effectiveness and efficiency of hydroxy termination titration methods in chemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Redox Titrations via Interdigitated Electrode Arrays: Application to the Mediated Electron Transfer Interrogation of Charge and Rate on Electrodeposited Polymers

Mediated electron transfer (MET) plays a crucial role in energy storage and conversion technologies such as redox targeting flow batteries (RTFBs), yet its experimental investigation often requires labor-intensive and low-throughput setups. To address this, we developed a microfabricated interdigitated electrode array (IDA) platform that enables automated, high-throughput electrochemical redox titration measurement to be performed to study the MET process. Our redox titration method enables simultaneous measurement of the charge capacity and rate of MET processes on a material or surface. Automated redox titration (ART) facilitates systematic investigation of the MET process across a broad parameter space, exemplified through the study of polypyrrole (PPy) and a pyrene-4,5,9,10-tetrone azo group-based polymer (PTAP), both redox-active polymers relevant to various energy storage applications. Using PPy as a model material, 500 redox titration measurements were conducted within 50 h, varying the electrode gap widths, polymer charging potentials, voltammetric scan rates, and electrolyte concentrations. Finite-element simulations confirmed the electrochemical responses and elucidated the kinetics of the MET reactions. Our automated methodology was further tested with PTAP, revealing a surprising charging potential dependence on the rate of MET. The automation, flexibility, and scalability of our redox titration platform pave the way not only for advanced studies of MET processes relevant to RTFBs, but also with implications in the understanding of next-generation energy storage materials, molecular electrocatalysis, and biosensing.

electrochemical analysis↗

Thermochemical measurements of FeCl 2 in LiCl via electromotive force, coulometric titration, and cyclic voltammetry

The thermochemical properties of FeCl 2 in the LiCl-FeCl 2 binary system were determined at 913 K using electromotive force (emf) cells containing pre-made and coulometrically titrated molten salt compositions. Coulometric titration to in-situ change the salt composition utilizes the multiple valences of Fe ions and the tendency of Fe 3+ ions to comproportionate with Fe metal, forming additional Fe 2+ . The emf results were used to define the compositions in which Henry’s law is applicable, up to approximately 2 mol% FeCl 2 . Thermochemical quantities were determined from emf using a Standard Lithium Chloride Electrode (SLiCE) which defines 0 V as the reduction of Li + in pure LiCl at all temperatures. Validation of emf measurements was performed by comparing the formal potential measured by using cyclic voltammetry (2.224 ± 0.013 V vs SLiCE) and emf measurements (2.236 ± 0.004 V). In conclusion, this work shows that coulometric titration of an electroactive species that undergoes comproportionation can be used to rapidly obtain granular emf data in molten salt systems.

Coulometric titration↗

LLNL Automized Surface Titration Model

The LLNL Automized Surface Titration Model (L-ASTM) is a community data-driven surface complexation modeling workflow for simulating potentiometric titration of mineral surfaces. The model accepts raw experimental potentiometric titration data formatted in a findable, accessible, interoperable, and reusable (FAIR) structure. The workflow was coded in Python and coupled to PHREEQC for surface complexation modeling and PEST for data fitting and parameter estimation.

Solchan, Han↗

Community Based Data of Potentiometric Titration of Iron Oxides: Ferrihydrite (HFO), Goethite, Hematite, Magnetite

This data release includes experimental data of potentiometric titration for iron oxides. The data in the provided .csv files is not our own experimental data but have been compiled from the multiple literature sources. The master database is L-SCIE (LLNL Surface Complexation/Ion Exchange) database, and the provided .csv files are extracted data from L-SCIE. The .csv files were obtained by using the Lawrence Livermore National Laboratory Surface Complexation Database Converter (SCDC) code written in the R programming language (free licensing available at https://ipo.llnl.gov/technologies/software/llnl-surface-complexation-database-converter-scdc).The released data was used for developing a comprehensive community data-driven surface complexation modeling (SCM) framework for simulating potentiometric titration of mineral surfaces. Compiled community data for ferrihydrite, goethite, hematite, and magnetite are fit to produce representative protolysis constants that can reproduce potentiometric titration data collected from multiple literature sources.

54 ENVIRONMENTAL SCIENCES↗

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Calorimetry, activity, and micro-FTIR analysis of CO chemisorption, titration, and oxidation on supported Pt

The value of in situ analysis on CO chemisorption, titration and oxidation over supported Pt catalysts using calorimetry, catalytic and micro-FTIR methods is illustrated using silica- and titania-supported samples. Isothermal CO-O and O2-CO titrations have not been widely used on metal surfaces and may be complicated if some oxide supports are reduced by CO titrant. However, they can illuminate the kinetics of CO oxidation on metal/oxide catalysts since during such titrations all O and CO coverages are scanned as a function of time. There are clear advantages in following the rates of the catalyzed CO oxidation via calorimetry and gc-ms simultaneously. At lower temperatures the evidence they provide is complementary. CO oxidation and its catalysis of CO oxidation have been extensively studied with hysteresis and oscillations apparent, and the present results suggest the benefits of a combined approach. Silica support porosity may be important in defining activity-temperature hysteresis. FTIR microspectroscopy reveals the chemical heterogeneity of the catalytic surfaces used; it is interesting that the evidence with regard to the dominant CO surface species and their reactivities with regard to surface oxygen for present oxide-supported Pt are different from those seen on graphite-supported Pt.

Sermon, Paul A.↗

Titrating Controlled Defects into Si-LTA Zeolite Crystals Using Multiple Organic Structure-Directing Agents

Controlling defects in zeolites is crucial for tuning their adsorption and catalytic properties. In this work, we have performed an integrated zeolite synthesis, spectroscopy, and density functional theory study to test the limit of F– as a charge-balancing agent that mitigates defects in siliceous zeolites. We focused on the synthesis of siliceous zeolite LTA at 150 °C with 1,2-dimethyl-3-(4-methylbenzyl) imidazolium as the primary organic structure-directing agent (OSDA) and tetramethyl ammonium (TMA) as the secondary OSDA. By varying the amount of TMA in the synthesis gel, positive charges were titrated into the resulting as-made Si-LTA. Surprisingly, we found that greater TMA concentration does not induce more F– to enter into the zeolite. 29Si solid-state MAS NMR, Raman spectroscopy, and density functional theory suggest that this system has surpassed its capacity for F– to balance OSDA charge, and additional positive charge is balanced by Si–O– framework defects. The number of defects in the as-made Si-LTA can be precisely titrated by the amount of TMA in the zeolite structures. For the Si-LTA synthesized without TMA, framework defects formed in the early stage of crystal growth were found to heal during later crystallization, leading to defect-free Si-LTA. However, for the Si-LTA synthesized with TMA, the defects formed in early stages do not heal. A DFT thermodynamic analysis explains that crowding of Si-LTA pores by TMA impedes defect healing; this prediction is corroborated by synthesis experiments at an elevated temperature (170 °C). These results indicate that F– can have a limited capacity to balance OSDA charge in zeolite synthesis, opening up a third route to zeolite synthesis intermediate between the fluoride and hydroxide routes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isopotential Electron Titration: Hydrogen Adsorbate-Metal Charge Transfer

The extent of charge transfer between an adsorbate and thermocatalytic surface plays a key role in determining catalytic activity, but direct and quantitative measures have remained elusive. Here, we report the method of isopotential electron titration (IET), an approach that directly measures charge transfer between adsorbates and catalytic surfaces. Charge transfer between Pt and adsorbed hydrogen adatoms was investigated using a catalytic condenser, where the Pt surface was separated from a p-type silicon layer by a hafnia dielectric film. By forcing the Pt and Si layers into isopotential conditions, charge transfer between the adsorbate and Pt surface was titrated through an external circuit. Hydrogen atoms donated electrons to Pt upon adsorption, which was quantitatively reversed upon desorption. Across a temperature range of 125–200 °C (surface hydrogen fractional coverages of 80–100%), the charge transferred to Pt by an adsorbed hydrogen atom was measured to be 0.19 ± 0.01% |e|/H. Bader charge analysis of the extent of charge transfer was in agreement with experimental measurements, with a calculated net donation of 0.4% |e|/H. The ability to experimentally quantify surface charge transfer provides an electronic-based approach to characterize catalytic surfaces, the adsorbed moieties residing on them, and the chemical reactions they accelerate.

Adsorption↗

Bioavailable iron titrations reveal oceanic Synechococcus ecotypes optimized for different iron availabilities

Abstract The trace metal iron (Fe) controls the diversity and activity of phytoplankton across the surface oceans, a paradigm established through decades of in situ and mesocosm experimental studies. Despite widespread Fe-limitation within high-nutrient, low chlorophyll (HNLC) waters, significant contributions of the cyanobacterium Synechococcus to the phytoplankton stock can be found. Correlations among differing strains of Synechococcus across different Fe-regimes have suggested the existence of Fe-adapted ecotypes. However, experimental evidence of high- versus low-Fe adapted strains of Synechococcus is lacking, and so we investigated the transcriptional responses of microbial communities inhabiting the HNLC, sub-Antarctic region of the Southern Ocean during the Spring of 2018. Analysis of metatranscriptomes generated from on-deck incubation experiments reflecting a gradient of Fe-availabilities reveal transcriptomic signatures indicative of co-occurring Synechococcus ecotypes adapted to differing Fe-regimes. Functional analyses comparing low-Fe and high-Fe conditions point to various Fe-acquisition mechanisms that may allow persistence of low-Fe adapted Synechococcus under Fe-limitation. Comparison of in situ surface conditions to the Fe-titrations indicate ecological relevance of these mechanisms as well as persistence of both putative ecotypes within this region. This Fe-titration approach, combined with transcriptomics, highlights the short-term responses of the in situ phytoplankton community to Fe-availability that are often overlooked by examining genomic content or bulk physiological responses alone. These findings expand our knowledge about how phytoplankton in HNLC Southern Ocean waters adapt and respond to changing Fe supply.

Gilbert, Naomi E. (ORCID:0000000256915547)↗

Galvanostatic Intermittent Titration Technique Reinvented: Part II. Experiments

Following a critical review of the galvanostatic intermittent titration technique in Part I, here we experimentally demonstrate how to extract chemical diffusivity with a modified method. We prepare dense bulk samples that ensure diffusion-limitation. We utilize the scaling with $\sqrt{{t}_{\mathrm{relax}}+\tau }-\sqrt{{t}_{\mathrm{relax}}}$ (trelax: relaxation time; τ: pulse duration), avoiding problems with composition-dependent overpotentials. The equilibrium Nernst voltage is measured separately using small porous particles. This separation between the diffusion measurement and the titration procedure is critical for performing each measurement in a reliable setting. We report the chemical diffusion coefficients of LixNi1/3Mn1/3Co1/3O2 and their activation energy. We extract ionic conductivity and compare it with total conductivity to confirm ion-limitation in chemical diffusion. The measurements suggest that the time scale for diffusion in typical Li-ion battery particles could be much shorter than that of the intercalation/deintercalation processes at the particle surface (Biot number less than 0.1).

25 ENERGY STORAGE↗

Destructive Analysis of TRISO Particles: Crush/Burn/Leach Followed by Davies-Gray Titration and IDMS

The accurate accounting of nuclear materials is a cornerstone of international nuclear safeguards. One emerging challenge in this domain is the fabrication of TRIstructural ISOtropic (TRISO) particle fuels. Although these innovative fuel forms are critical for advanced reactor applications, their robust refractory ceramics and coating compositions present significant obstacles to destructive analysis (DA) methods. Ensuring full and quantitative recovery from these particles is essential for accurate mass accountancy. The current study was initiated to address these challenges, first by validating a previously established destructive method developed by Oak Ridge National Laboratory (ORNL) for the quantitative recovery of uranium from TRISO particles and then following that process with uranium content determination through isotope dilution mass spectrometry (IDMS) and Davies-Gray titration. This study expands on the scope of a digestive method that was developed under the Advanced Gas Reactor Fuel Development and Qualification program and is currently implemented in both the Coated Particle Fuel Development Laboratory and Irradiated Fuels Examination Laboratory at ORNL. The success of the previous Advanced Gas Reactor work relied on developing a DA method to evaluate the fabrication process and reactor experiments. The methodology described in this report was designed to rigorously investigate the efficacy of the crush/burn/leach sample preparation of TRISO particles; it aims to quantify uranium recovery while also assessing the effects of TRISO constituents (e.g., silicon and zirconium) on analytical precision and accuracy. By comparing the results from the titration method and IDMS, we sought to determine whether existing analytical procedures accepted by the International Atomic Energy Agency (IAEA) could be effectively translated to TRISO fuel forms. The team employed an approach that involved processing replicate TRISO samples, optimizing the milling (i.e., crushing) step and performing serial leaches. The elemental composition of the analytical samples was examined to prepare for interference studies in the second year of this project. The integration of gamma spectrometry to verify residual uranium activity further strengthened the validation. Statistical methods were applied to the collected data to evaluate the uncertainties arising from sampling, sample preparation and uranium quantification. These uncertainties were then compared to the IAEA’s international target values (ITVs). Additional data collected in upcoming project work will strengthen the uncertainty estimates. Ultimately, it is hoped that this project will contribute materially to the body of work related to characterization of TRISO based fuels for the purpose of material accountancy and its applications to international safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of atmospheric OH by titration of near-IR fluorescent dyes

Recent research has shown that certain polymethine dyes can be detected at ultratrace levels (greater than or equal to 6x10(exp -14) M) in solution by fluorimetry. These detection limits are possible because of the inherent sensitivity of fluorescence techniques, because the dyes fluoresce in the near infrared region where background interference is negligible, and because powerful infrared diode lasers are now available to improve the signal to noise ratio. Other work has shown that the hydroxyl radical destroys the ability of polymethine dyes to fluoresce. These observations form the basis for a new hydroxyl radical detector that is essentially a fluorometric titrator. Theoretically, the detector should show an acceptable sensitivity and response time. Assuming that the atmospheric HO concentration is about 10(exp -11) moles m(exp -3) (i.e. 10(exp 6) molecules cm(exp -3)), then 10 L of air 'titrated' with 20 mL of 10(exp -11) M dye solution (an easily detected concentration) should result in a drop in the fluorescent signal of 50 percent - a readily detectable change. At a flow rate of 3 L min(exp -1) the sampling time would be 3 minutes. The biggest potential problem is selectivity: other oxidants may also cause the fluorescence signal to be lost. The chemistry of polymethine dyes has not been studied in detail and so no quantitative data are available. However, a survey of the literature suggests that in general HO should react up to six orders of magnitude faster than HO2 and other radicals such as RO2 and RO. It should also react much more rapidly than H2O2 and O3. Thus it may be possible to discriminate kinetically against potential interfering substances. It was shown in the laboratory that 10(exp -4) M H2O2 has little effect on the absorption spectrum of the dye IR125 over a period of hours but that the band at 780 nm is slowly lost in water over a period of days even under argon in the dark. By contrast, DMSO solutions of IR125 are stable.

Betterton, Eric A.↗

Protein sequences and redox titrations indicate that the electron acceptors in reaction centers from heliobacteria are similar to Photosystem I

Photosynthetic reaction centers isolated from Heliobacillus mobilis exhibit a single major protein on SDS-PAGE of 47 000 Mr. Attempts to sequence the reaction center polypeptide indicated that the N-terminus is blocked. After enzymatic and chemical cleavage, four peptide fragments were sequenced from the Heliobacillus mobilis apoprotein. Only one of these sequences showed significant specific similarity to any of the protein and deduced protein sequences in the GenBank data base. This fragment is identical with 56% of the residues, including both cysteines, found in highly conserved region that is proposed to bind iron-sulfur center Fx in the Photosystem I reaction center peptide that is the psaB gene product. The similarity to the psaA gene product in this region is 48%. Redox titrations of laser-flash-induced photobleaching with millisecond decay kinetics on isolated reaction centers from Heliobacterium gestii indicate a midpoint potential of -414 mV with n = 2 titration behavior. In membranes, the behavior is intermediate between n = 1 and n = 2, and the apparent midpoint potential is -444 mV. This is compared to the behavior in Photosystem I, where the intermediate electron acceptor A1, thought to be a phylloquinone molecule, has been proposed to undergo a double reduction at low redox potentials in the presence of viologen redox mediators. These results strongly suggest that the acceptor side electron transfer system in reaction centers from heliobacteria is indeed analogous to that found in Photosystem I. The sequence similarities indicate that the divergence of the heliobacteria from the Photosystem I line occurred before the gene duplication and subsequent divergence that lead to the heterodimeric protein core of the Photosystem I reaction center.

NASA Discipline Number 52-30↗

A Clustering-based biased Monte Carlo Approach to Protein Titration Curve Prediction

We develop and implement a novel approach to computing the ensemble averages in systems characterized by pair-wise interactions between the entities. Methods involving full enumeration of the configuration space result in exponential complexity. Sampling methods such as Markov Chain Monte Carlo (MCMC) algorithms have been proposed to tackle the exponential complexity of these problems. In certain scenarios where significant energetic coupling exists between the entities, the accuracy of the such algorithms can be diminished. We propose a strategy to improve the accuracy of the MCMC runs by taking advantage of the cluster structure in the interaction energy matrix. We propose two different schemes for performing the biased MCMC runs on the partitioned systems and show that they are valid MCMC schemes. We then apply these algorithms to the problem of computing the protonation fractions and hence the titration curves of titratable protein residues that constitute a given protein. We leverage both synthesized and real-world systems and show the improved performance of our biased MCMC methods when compared to the regular MCMC method.

Visweswara Sathanur, Arun↗

Evaluation of acidity of hierarchical zeolites using a potentiometric titration method

The method of potentiometric titration and corresponding determination of pK a of acid sites by the Gran method was applied for hierarchical zeolite materials. For hierarchical Al-, Ga- and B-silicate zeolites of MOR, BEA, MFI and MTW structural types with the morphology of aggregated nanosheets, nanorods or close to spherical nanoparticles, the distribution of acid sites by strength was determined. Furthermore, the dependence of the acidity spectrum (strength of acid sites) on the type of zeolite structure and the nature of an isomorphously substituted cation, on the one hand, and on the morphology of zeolite nanocrystals, on the other hand, was demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NWAL Validation Report for U Assay by Potentiometric Titration (Modified Davies and Gray Technique) and U and PU Assay by Isotope Dilution Mass Spectrometry

SRNL Sensing & Metrology, previously Analytical Laboratory, is a member of the IAEA Network of Analytical Laboratories for Nuclear Material Measurement that is qualified to provide Uranium and Plutonium isotopic analysis of nuclear materials by Thermal Ionization Mass Spectrometry. As part of the membership, SRNL participated in the 2019 Nuclear Material Round Robin to maintain the qualification to provide isotopic analysis. SRNL also participated with the additional intent to qualify Uranium Assay by Potentiometric Titration (Davies and Gray method) and Uranium and Plutonium Isotope Dilution by Thermal Ionization Mass Spectrometry as part of the International Atomic Energy Agency’s Network of Analytical Laboratories. The proficiency test exercise was conducted by the Office of Safeguards Analytical Services, Department of Safeguards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗