EXPERIMENTAL INVESTIGATION OF EFFECTS OF COMBUSTION-CHAMBER LENGTH AND INLET TOTAL TEMPERATURE, TOTAL PRESSURE, AND VELOCITY ON AFTERBURNER PERFORMANCE
Afterburner combustion efficiency - effects of chamber length, temperature, pressure and velocity
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Afterburner combustion efficiency - effects of chamber length, temperature, pressure and velocity
Explore the source record for details and available documents.
Wall and total temperature variations effects on transition Reynolds number in hypersonic He tunnel, noting sound mode dominance
High temperature, high altitude total temperature sensor development - thermocouple device
The dependency of Mach number on the Prandtl-Meyer function was numerically determined by iterating the Prandtl-Meyer function and applying the Muller method to converge on the Mach number for flows in cryogenic parahydrogen and nitrogen at various total pressures and total temperatures. The results are compared with the ideal diatomic gas values and are presented in tabular form.
The authors address the thermal analysis of a water cooled supersonic total temperature probe tested in a Mach 2 flow, up to 1366 K total temperature. The goal of this experiment was the determination of high-temperature supersonic jet mean flow temperatures. An 8.99 cm exit diameter water cooled nozzle was used in the tests. It was designed for exit Mach 2 at 1366 K exit total temperature. Data along the jet centerline were obtained for total temperatures of 755 K, 1089 K, and 1366 K. The data from the total temperature probe were affected by the water coolant. The probe was tested through a range of temperatures between 755 K and 1366 K with and without the cooling system turned on. The results were used to develop a relationship between the indicated thermocouple bead temperature and the freestream total temperature. The analysis and calculated temperatures are presented.
Water-cooled supersonic total-pressure, static-pressure, and total-temperature probes developed to study high-temperature jet plumes. Total-temperature probe tested up to 2,000 degrees F incorporates annular cooling system up to thermocouple lead. Lead extends into test chamber to sense temperature of supersonic external flow. Design novel and significant. Applicable in development of jet engines and in research on fast flows of hot gases.
This paper reports on temperature and humidity measurements from a series of ice-crystal icing tunnel experiments conducted in June 2018 at the Propulsion Systems Laboratory at the NASA Glenn Research Center. The tests were fundamental in nature and were aimed at investigating the icing processes on a two-dimensional NACA0012 airfoil subjected to artificially generated icing clouds. Prior to the tests on the airfoil, a suite of instruments, including total temperature and humidity probes, were used to characterize the thermodynamic flow and icing cloud conditions of the facility. Two different total temperature probes were used in these tests which included a custom designed rearward facing probe and a commercial self-heating total temperature probe. The rearward facing probe, the main total temperature probe, was designed to reduce and mitigate the contaminating effects of icing and ingestion of ice crystals and water droplets at the probe's inlet. The probe also serves as an air-sample inlet for a light absorption based humidity measurement. The paper includes a section which discusses total temperature and humidity measurement considerations, and another section which provides an analysis of the main probe's performance characteristics. A computational fluid dynamic model of the flow around the probe was also conducted to gain insight into the trajectory of the flow entering the probe inlet. The experiments included a series of tests in which the relative humidity of the facility flow was swept through with increasingly larger values. The data showed that the rearward facing probe can reasonably capture the flow's total temperature and humidity under mild to moderate icing conditions but produces anomalous results under more intense icing conditions. The experimental data was also compared to an in-house developed thermodynamic model which takes into account the interaction of the main flow with the icing cloud. Comparison to the thermodynamic model showed that the rearward facing probe measured the predicted trends.
Engine Icing Performance loss: rollback, surge, flameout, and even internal engine damagePartial melting and refreeze of ice inside engine core (Mason et al., 2006). Ingestion of ice crystals and aggregates, mixed-phase droplets, or supercooled liquid dropletsNeed to better understand the conditions and properties that lead to engine icing.Simulation and analysis (physical and computational, and modeling)Test facilities (PSL, NRC, ...). Thermal and computational models and analysisProbesMultiple probes (aerothermal probes and ice cloud characterization probes and techniques). Total temperatureTraditional total temperature probes (vented forward facing)Heated total temperature probes (Goodyear). Rearward facing (developmental). Total temperature relevance. Thermal interaction between the icing cloud and air flow impinging particles contribute to kinetic heating effect (Gent et al., 2000). Measurement considerations Temperature sensor accuracy. Incomplete recovery of total temperature. Thermal surfaces (sources and sinks). Flow effects (viscous losses). Debris contamination, including icing and ice ingestion.
The ability to accurately set repeatable total temperature conditions is critical for collecting quality icing condition data, particularly near freezing conditions. As part of efforts to continually improve data quality in the NASA Glenn Icing Research Tunnel (IRT), new facility instrumentation and new calibration hardware for total temperature measurement were installed and new operational techniques were developed and implemented. This paper focuses on the improvements made in the calibration of total temperature in the IRT.
The isentropic expansions of parahydrogen at various total pressures and total temperatures were numerically determined by iterating Mach number and by using a modified interval halving method. The calculated isentropic values and related properties are presented in tabulated form.
The prediction of the cooled aerodynamic performance, for both stators and turbines, at actual primary to coolant inlet total temperature ratios from the results obtained at a reduced total temperature ratio is described. Theoretical and available experimental results were compared for convection film and transpiration cooled stator vanes and for a film cooled, single stage core turbine. For these tests the total temperature ratio varied from near 1.0 to about 2.7. The agreement between the theoretical and the experimental results was, in general, reasonable.
An experimental study has been conducted of the influence of wall to total temperature ratio on the heat transfer to the leeside of a 040A space shuttle configuration. The heat transfer tests were made at a Mach number of 10 and a Reynolds number of one million per foot for angles of attack from 0 deg to 30 deg. Range of wall to total temperature ratio was from 0.16 to 0.43. Where the heat transfer was relatively high and the laminar boundary layer attached, the local heat transfer decreased by about 20 percent as the wall to total temperature ratio was increased from the minimum to the maximum test value. On regions of separated flow and vortex reattachment, very low heating rates were measured at some conditions and indicate significant changes are occurring in the leeside flow field. No single trend of heat transfer variation with wall to total temperature ratio could be observed.
An experimental temperature probe package containing a fluidic oscillator temperature probe and a shielded thermocouple temperature probe was tested during several X-15 flights. The X-15 flights provided greatly varying test conditions, including a wide range of rapidly changing total temperatures and Mach numbers which extended from subsonic to hypersonic speeds. Within restricted ranges of free-stream Mach number, free-stream unit weight flow, and local stagnation pressure, both probes yielded ramp outputs of temperature parallel to ramp inputs of free-stream total temperature. Within these ranges both probes were used to determine total temperature in the Mach 6 temperature environment. Because ambient temperature was known, both probes were used to estimate velocity and Mach number.
Improved probe designed to be mounted at wingtip of airplane and used for measuring total temperature of air when airplane flies at high angles of attack. Four fins and swivel mount enable probe to align itself aerodynamically with local flow of air. Thus, stagnated-flow condition needed for accurate measurement of total temperature achieved.
The heat transfer characteristics of a three-wire hot-wire probe operated with a constant temperature anemometer were investigated in the subsonic compressible flow regime. The sensitivity coefficients, with respect to velocity, density and total temperature, were measured and the results were used to calculate the velocity, density, and total temperature fluctuations in the test section of the Langley 0.3-m Transonic Cryogenic Tunnel (TCT). These results were extended to give estimates for fluctuations due to vorticity, sound, and entropy. In addition, attempts were made to determine the major source of disturbances in the 0.3-m TCT.
The design and test results of two types of total temperature probes that were used for hypersonic boundary-layer measurements are presented. The intent of each design was to minimize the total error and to maintain minimal size for measurements in boundary layers 1.0 in. thick and less. A single platinum-20-percent-rhodium shield was used in both designs to minimize radiation heat transfer losses during exposure to the high-temperature test stream. The shield of the smaller design was flattened at the flow entrance to an interior height of 0.02 in., compared with 0.03 in. for the larger design. The resulting vent-to-inlet area ratios were 60 and 50 percent. A stainless steel structural support sleeve that was used in the larger design was excluded from the smaller design, which resulted in an outer diameter of 0.059 in., to allow closer placement of the probes to each other and to the wall. These small design changes to improve resolution did not affect probe performance. Tests were conducted at boundary-layer-edge Mach numbers of 5.0 and 6.2. The nominal free-stream total temperatures were 2600 degrees and 3200 degrees R. The probes demonstrated extremely good reliability. The best performance in terms of recovery factor occurred when the wire-based Nusselt number was at least 0.04. Recommendations for future probe designs are included.
This paper describes a detailed experimental study of Mach number centerline characteristics of unheated and heated freejets. The jet characteristics were obtained at a range of jet Mach numbers from 0.1 to 0.9 and jet total temperatures up to 900 K. Previously published results showed that the jet total temperature significantly affects the nozzle-exit, boundary-layer characteristics. The results of this study indicate that a strong correlation exists between nozzle-exit, boundary-layer conditions and freejet development. It is clear from this investigation that experimental data on freejet development cannot be meaningfully compared from one facility to another without specific knowledge of nozzle-exit, boundary-layer conditions. It was concluded that direct effect of the jet operating conditions (elevated flow temperature) on freejet development is much less important than the indirect effect due to changed nozzle-exit, boundary-layer characteristics.