Control Board Digital Interface Input Devices – Touchscreen, Trackpad, or Mouse?

The authors collaborated with a power utility to evaluate input devices for use in the human system interface (HSI) for a new digital Turbine Control System (TCS) at a nuclear power plant (NPP) undergoing a TCS upgrade. A standalone dynamic software simulation of the new digital TCS and a mobile kiosk were developed to conduct an input device study to evaluate operator preference and input device effectiveness. The TCS software presented the anticipated HSI for the TCS and mimicked (i.e., simulated) the turbine systems’ responses to operator commands. Twenty-four licensed operators from the two nuclear power units participated in the study. Three input devices were tested: a trackpad, mouse, and touchscreen. The subjective feedback from the survey indicates the operators preferred the touchscreen interface. The operators subjectively rated the touchscreen as the fastest and most comfortable input device given the range of tasks they performed during the study, but also noted a lack of accuracy for selecting small targets. The empirical data suggest the mouse input device provides the most consistent performance for screen navigation and manipulating on screen controls. The trackpad input device was both empirically and subjectively found to be the least effective and least desired input device.

control room modernization↗

Improvements in the electroless deposition of Ag nanowires in hot ethylene glycol for resistive touchscreen device

Highlights: • High quality Ag nanowires prepared by an improved electroless deposition process in hot ethylene glycol. • Increase in nanowire length due to the sonication of AgNO{sub 3}/EG solution and salt addition. • Resistive touchscreen device fabrication using Ag nanowire transparent conducting electrodes. - Abstract: We report several approaches to improve the quality of silver (Ag) nanowires synthesized by electroless deposition in hot ethylene glycol (polyol). Ultralong Ag nanowires with lengths up to 50 μm and about 60 nm in mean diameter were prepared using CuCl{sub 2} as stabilizer. Without CuCl{sub 2}, mostly large Ag particles were produced due to oxidative etching of multiply-twinned Ag seeds. Sonication of the AgNO{sub 3}/EG solution prior to injection resulted in longer and thinner nanowires. Without these pretreatments, low aspect ratio Ag nanowires mixed with nanoparticles were produced. The Ag nanowire transparent conducting electrode attained a low sheet resistance of 57.4 Ω/sq and high optical transmittance of 90%. A resistive touch screen device with a microcontroller was fabricated to prove the viability of Ag nanowire electrode for optoelectronic device applications. The Ag nanowire electrodes exhibited a resistive characteristic, which varied depending on the point of contact on the touch screen.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thermoluminescence and phototransferred thermoluminescence dosimetry on mobile phone protective touchscreen glass

Thermoluminescence and phototransferred thermoluminescence measurements of protective glass from smartphones are described. Samples of Gorilla Glass were examined from nine different manufacturers and 40 different phone models. Additionally, 12 glasses believed to be original equipment manufacturer replacements, as well as three glass samples from U.S. finishers, were also studied. Altogether, 99 different Gorilla Glass samples were examined. The radiation-induced thermoluminescence signal produced glow curve shapes specific to the Gorilla Glass generations and could be used to distinguish between them. A background thermoluminescence (and phototransferred thermoluminescence) signal was found in all unirradiated samples. Its intensity and shape were found to be dependent on the Gorilla Glass generation, phone manufacturer, and phone model. The background signal was demonstrated to be produced by ultraviolet light exposure; the shape of the background signal was able to be reproduced by the combined exposure to a broad-spectrum solar simulator and a 302 nm ultraviolet light source. The background signal intensity was found to vary with the location from which it was taken on the glass. It was also found to be dependent on the depth within the Gorilla Glass due to absorption of the ultraviolet light as it traversed the medium. Removal of the glasses’ surface layers was found to be an inadequate method for removing the background signal. In some samples, the background signal intensity was large enough to significantly contribute to the total thermoluminescence (and phototransferred thermoluminescence) signal; therefore, a matrix deconvolution method was introduced to separate the background signal and radiation-induced signal. This method was found to enable dose reconstruction using the radiation-induced signal alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improved Performance of Zinc Oxide Thin Film Transistor Pressure Sensors and a Demonstration of a Commercial Chip Compatibility with the New Force Sensing Technology

Abstract A zinc oxide thin film transistor is developed and optimized that simultaneously functions as a transistor and a force sensor, thus allowing for scalable integration of sensors into arrays without the need for additional addressing elements. Through systematic material deposition, microscopy, and piezoelectric characterization, it is determined that an O 2 rich deposition condition improves the transistor performance and pressure sensing characteristics. With these optimizations, a sensitivity of 4 nA kPa −1 and a latency of below 1 ms are achieved, exceeding the criteria for successful commercialization of arrayed pressure sensors. The functionality of 16 × 16 pressure sensor arrays on thin bendable glass substrates for integrated low weight and flexible touchscreen displays is fabricated and demonstrated and read‐out electronics to interface with the arrays and to record their response in real‐time are developed. Finally, the application of these sensors for mobile displays via their operation with an existing commercial touch integrated circuit controller is demonstrated.

Vishniakou, Siarhei↗

Fabrication of nanoporous doped metal oxide coatings via selective infiltration of a block copolymer template: The case of Al-doped zinc oxide

Conductive nanoporous conformal coatings are important for various applications including touchscreens, displays, and electrochromic windows, though design of such coating with controlled porosity and composition remains challenging. We propose a sequential infiltration synthesis (SIS) method for the fabrication of nanoporous conductive aluminum-doped zinc oxide (AZO) films by infiltrating block copolymer (BCP) templates, specifically polystyrene-block-polyvinyl pyridine (PS-b-P4VP), with diethyl zinc and trimethyl aluminum precursors. Tunability of both porosity and electrical conductivity is achieved by precisely controlling the swelling behavior of the polymer templates and adjusting the number of SIS cycles. Further, our results reveal that porosity levels can reach up to 80 %, with resistivity as low as ~7.83 Ωcm. Using conductive atomic force microscopy (C-AFM) and Hall effect measurements, we show that lower concentrations of aluminum doping relative to zinc (around 1: 17) results in higher conductivity of the AZO films. Additionally, AZO is based on zinc oxide (ZnO) which is cost-efficient, abundant and less toxic than commonly used transparent conductive oxides such as indium tin oxide (ITO) and fluorine-doped tin oxide (FTO). Therefore, this novel approach opens new possibilities for creating highly porous, conformal, conductive AZO coatings with customizable porosity and composition, making them ideal candidates for diverse optoelectronic applications.

36 MATERIALS SCIENCE↗

Shape-Controlled Synthesis of Copper Nanocrystals for Plasmonic, Biomedical, and Electrocatalytic Applications

As a metal that can occur in nature in the elemental form, copper (Cu) has been used by humans since ca. 8000 BC. With most properties matching those of Ag and Au, Cu has played a more significant role in commercial applications owing to its much higher (the 25th among all elements) abundance in Earth’s crust and thus more affordable price. In addition to its common use as a conductor of heat and electricity, it is a constituent of various metal alloys for hardware, coins, strain gauges, and thermocouples. Bulk Cu is also widely utilized as a building material. When downsized to the nanoscale, Cu and Cu-based structures have found widespread use in applications ranging from electronics to optoelectronics, plasmonics, catalysis, sensing, and biomedicine. Besides Ag and Au, for example, Cu is another metal known for its localized surface plasmon resonance (LSPR) in the visible and near-infrared regions when prepared as nanocrystals. As a potential replacement for indium–tin oxide (ITO) films, polymer coatings containing Cu nanowires are strong candidates for the fabrication of transparent and flexible electrodes key to touchscreen display and related applications. The commercial catalysts for water–gas shift and gas detoxification reactions are also based on Cu nanoparticles. Most recently, Cu nanocrystals have attracted considerable interest for their superior selectivity toward hydrocarbons and multicarbon species during the electrochemical reduction of CO 2 . The success of all these applications critically depends on our ability to control the shape and surface structure of the nanocrystals. Relative to Ag and Au, it is more challenging to generate Cu-based nanocrystals using colloidal methods due to its lower reduction potential and greater vulnerability to oxidation. Here, in this account, we discuss recent progress in the colloidal synthesis of Cu nanocrystals with controlled shapes for plasmonic, biomedical, and catalytic applications. With glucose serving as a reducing agent, Cu nanocrystals bearing a twinned or single-crystal structure can be synthesized using an aqueous system with the assistance of hexadecylamine (HDA). In this synthetic protocol, HDA not only passivates the surface to protect the nanocrystals from oxidation but also manipulates the reduction kinetics of Cu(II) precursor through coordination and an increase of solution pH. Typical products include nanocubes and penta-twinned nanowires whose surfaces are dominated by {100} facets. When seeds produced either in situ or ex situ are introduced, Cu-based nanocrystals featuring a singly twinned, core–shell, or Janus structure can be readily synthesized. Aside from segmented structures, Cu-based alloys with various noble metals can be synthesized through coreduction or a galvanic replacement reaction with preformed Cu nanocrystals. By controlling the size and/or shape of Cu nanocrystals, their LSPR peaks can be tuned into the near-infrared region, making them promising candidates for optical imaging contrast enhancement and photothermal treatment. The inclusion of the 64 Cu isotope makes them immediately useful in positron emission tomography and thus image-guided therapy. The surface structure, elemental distribution, and valence state of Cu-based nanocrystals can all be tailored to augment their electrocatalytic performance. It is hoped that this Account will inspire more studies into the development of rational methods capable of producing Cu-based nanocrystals with diverse and well-controlled shapes, internal structures, and compositions for a broader range of applications.

36 MATERIALS SCIENCE↗

Crumpling of silver nanowires by endolysosomes strongly reduces toxicity

Fibrous particles interact with cells and organisms in complex ways that can lead to cellular dysfunction, cell death, inflammation, and disease. The development of conductive transparent networks (CTNs) composed of metallic silver nanowires (AgNWs) for flexible touchscreen displays raises new possibilities for the intimate contact between novel fibers and human skin. Here, we report that a material property, nanowire-bending stiffness that is a function of diameter, controls the cytotoxicity of AgNWs to nonimmune cells from humans, mice, and fish without deterioration of critical CTN performance parameters: electrical conductivity and optical transparency. Both 30- and 90-nm-diameter AgNWs are readily internalized by cells, but thinner NWs are mechanically crumpled by the forces imposed during or after endocytosis, while thicker nanowires puncture the enclosing membrane and release silver ions and lysosomal contents to the cytoplasm, thereby initiating oxidative stress. This finding extends the fiber pathology paradigm and will enable the manufacture of safer products incorporating AgNWs.

60 APPLIED LIFE SCIENCES↗

Chalcogenide Perovskite YScS 3 as a Potential p-Type Transparent Conducting Material

Transparent conducting materials (TCMs) have been widely used in optoelectronic applications such as touchscreens, flat panel displays and thin film solar cells. These applications of TCMs are currently dominated by n-type doped oxides. High-performance p-type TCMs are still lacking due to their low hole mobility or p-type doping bottleneck, which impedes efficient device design and novel applications such as transparent electronics. Here, based on first-principles calculations, we propose chalcogenide perovskite YScS 3 as a promising p-type TCM. According to our calculations, its optical absorption onset is above 3 eV, which allows transparency to visible light. Its hole conductivity effective mass is 0.48m 0 , which is among the smallest in p-type TCMs, suggesting enhanced hole mobility. It could be doped to p-type by group-II elements on cation sites, all of which yield shallow acceptors. Here, combining these properties, YScS 3 holds great promise to enhancing the performance of p-type TCMs toward their n-type counterparts.

36 MATERIALS SCIENCE↗

Preshaping clear glass at low temperatures

Advances in available glass chemistries and glass processing methods have accompanied and enabled some of the biggest technology revolutions, from the development and mass production of light bulbs to low-loss fiber optics and durable smartphone touchscreens. An emerging generation of low-temperature processing technologies aims to continue this important trend and make a broader array of glass components mass producible. In the issue, Mader et al. (1) describe one such innovation in glass processing—the use of low-temperature injection molding to preshape silica particle–filled composites that can later be transformed into transparent fused silica glass objects. Traditionally, transparent glass objects are manufactured in high volume from molten or softened glass, which is floated, drawn, blown, cast, or blow-molded to a desired shape (see the figure, top). The glass composition and processing technique dictate the working temperature, which is usually quite high (near 1000°C) and often restricts the choice of compatible equipment or limits the choice of glass composition. Because geometry-specific capital investment is required for production, drastic or frequent component design changes or small batches may be cost prohibitive. Alternatively, transparent glass components can also be shaped at ambient temperature from solid glass by a series of subtractive processes, including cutting or multiple stages of grinding, followed by slower processing steps, such as polishing or etching. This approach is somewhat less amenable to mass production, and certain geometries containing tool-inaccessible regions cannot be fabricated in this way. Several emerging glass-shaping technologies aim to reduce the required manufacturing temperatures and still provide access to a broader range of glass compositions and component geometries (see the figure). These approaches use a three-step process. First, a desired shape is preformed at low temperature from a glass-forming, organic-inorganic composite. Next, the preform is dried, and organic materials used to bind particles are removed. Finally, the preform is heated (sintered) well below the glass-melting temperature to densify to transparent glass. Although the second and third steps do occur at increased temperatures, only standard, geometry-agnostic driers and furnaces are required. This strategy builds on the well-studied sol-gel approach to forming monolithic glass, where silica network–forming chemical solutions are poured into molds, slowly dried, and condensed into dense glass without melting (2). In a departure from the sol-gel process, these new technologies use solvents, cross-linkers, and polymers to formulate organic-inorganic composites tuned for compatibility with a particular shaping process, with formats ranging from photocurable liquids to shear-thickening pastes to solids. The composite inorganic loadings are also typically higher than those in the pure sol-gel approach, which drastically reduces shrinkage in comparison.

36 MATERIALS SCIENCE↗

MC-15 Users Manual

The current iteration of field -capable neutron multiplicity counters is the Multiplicity Counter 15 tube detector (MC-15) shown in Figure 1. This was a tri-lab effort between Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The MC-15 incorporates significant improvements over previous man-portable neutron multiplicity counters of the LANL NPOD and the Ortec Fission Meter™. These improvements include finer time resolution of 100 ns, more advanced on-board computing power for near-real-time onboard analysis, a sunlight readable color touchscreen for ease of use, a USB 2.0 interface for data transfer, and hot-swappable rechargeable batteries that provide 14 hours of run time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LANL Interactive Display (LID) - DC Vault Updates and FY24 proposals

The LANL Interactive Display (LID) is an interactive touchscreen with a custom-built application designed to provide a geographic-based, virtual tour of the Laboratory’s organizations, facilities, programs, products, and capabilities. The Display is mounted on a portable stand and displayed in the classified vault of the Forrestal Building in Washington, D.C. The October 2023 updates include the latest inputs, including the addition of Nuclear Security Enterprise (NSE) information. Other major upgrades are detailed below.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In Vitro Dermal Safety Assessment of Silver Nanowires after Acute Exposure: Tissue vs. Cell Models

Silver nanowires (AgNW) are attractive materials that are anticipated to be incorporated into numerous consumer products such as textiles, touchscreen display, and medical devices that could be in direct contact with skin. There are very few studies on the cellular toxicity of AgNW and no studies that have specifically evaluated the potential toxicity from dermal exposure. To address this question, we investigated the dermal toxicity after acute exposure of polymer-coated AgNW with two sizes using two models, human primary keratinocytes and human reconstructed epidermis. In keratinocytes, AgNW are rapidly and massively internalized inside cells leading to dose-dependent cytotoxicity that was not due to Ag + release. Analysing our data with different dose metrics, we propose that the number of NW is the most appropriate dose-metric for studies of AgNW toxicity. In reconstructed epidermis, the results of a standard in vitro skin irritation assay classified AgNW as non-irritant to skin and we found no evidence of penetration into the deeper layer of the epidermis. The findings show that healthy and intact epidermis provides an effective barrier for AgNW, although the study does not address potential transport through follicles or injured skin. The combined cell and tissue model approach used here is likely to provide an important methodology for assessing the risks for skin exposure to AgNW from consumer products.

3D reconstructed epidermis model↗

What the Flicker is going on here? Temporal Light Modulation in Automotive Lighting

Temporal light modulation (TLM), colloquially known as “flicker,” is once again an issue in almost all lighting applications, due to widespread adoption of LED and OLED sources and their driving electronics. A subset of LED/OLED lighting systems delivers problematic TLM, often in specific types of residential, commercial, outdoor, and vehicular lighting. Dashboard displays, touchscreens, marker lights, taillights, daytime running lights, interior lighting, etc. frequently use PWM circuits to achieve different luminances for different times of day and user visual adaptation levels. The resulting TLM waveforms and viewing conditions can result in distraction and disorientation, nausea, cognitive effects, and serious health consequences in some populations, occurring with or without the driver, passenger, or pedestrian consciously “seeing” the flicker. There are three visual responses to TLM: direct flicker, the stroboscopic effect, and phantom array effect (also called the “beads effect”). Metrics for the first two have limitations in both calculation and application. The phantom array effect has no established visibility measure at all, and this is the effect most associated with vehicular flicker because of the widespread use of PWM. Conventional wisdom from the recent past, especially concerning acceptable driver frequency ranges, needs to be reconsidered and replaced with improved guidelines to protect health and comfort. Four principal TLM waveform characteristics affect TLM visibility: frequency, modulation depth, duty cycle, and waveshape. This paper proposes much higher frequency operation if PWM control cannot be avoided; but it may be possible to modify the four principal waveform characteristics together in order to achieve reduced TLM visibility and improved health and comfort.

flicker, TLM, temporal light modulation, automotiv↗

PenDoc Assistant v2.00

The purpose of this software is: - control and acquire data files from an Advion CMS single-quad mass spectrometer - targeted compound analysis - sample classification List of features: - use of experimental profiles for easy data acquisition - external touchscreen for easy experiment control - simple Yes/No answer if the signal of a targeted analyte is above a predefined limit - build database and classify sample using multiple spectral comparison/similarity methods Specific application: sample classification using an Advion CMS single quadrupole mass spectrometer connected to an Open Port Sampling Interface (OPSI).

Kertesz, Vilmos↗

A New Cryogenic Control System for the Vertical Test Area at Jefferson Lab

The Vertical Test Area at Jefferson Lab, consisting of eight vertical dewars, recently received a major upgrade by replacing the original (1995) cryogenic control system. A new, state-of-the-art, distributed control system (DC S) based on Programmable Logic Controllers (PLCs) was installed and commissioned. The new system increases facility throughput, reliability and cryogenic efficiency, while improving safety. The system employs a touchscreen graphical user interface and a highly redundant architecture on an Ethernet backbone.

Davis, K.↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

Workload Response to Soft Controls Presented on Two Interfaces - 382

Most operational Nuclear Power Plants (NPP) in the United States are primarily outfitted with physical (analog) Instruments and Controls (I and C). However, as parts wear out in legacy plants, these I and Cs are being replaced by digital interfaces. Furthermore, new plants are being proposed and built domestically and throughout the world that are composed primarily of soft controls in the main control room. To that end, it is important to understand if and how various types of interfaces affect performance. The present effort sought to compare a desktop and touchscreen interface. The Instantaneous Self-Assessment, the NASA-Task Load Index, and electrocardiography were used to assess workload response while performing three main control room task types on each interface. Results have implications for interface selection and assessment of new NPP main control room designs. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗