Search NASA⌕ Search

SEARCH · Search NASA

Results for “toxicity values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Protecting Astronaut Health at First Entry into Vehicles Visiting the international Space Station: Insights from Whole-Module Offgas Testing

NASA has accumulated considerable experience in offgas testing of whole modules prior to their docking with the International Space Station (ISS). Since 1998, the Space Toxicology Office has performed offgas testing of the Lab module, both MPLM modules, US Airlock, Node 1, Node 2, Node 3, ATV1, HTV1, and three commercial vehicles. The goal of these tests is twofold: first, to protect the crew from adverse health effects of accumulated volatile pollutants when they first enter the module on orbit, and secondly, to determine the additional pollutant load that the ISS air revitalization systems must handle. In order to predict the amount of accumulated pollutants, the module is sealed for at least 1/5th the worst‐case time interval that could occur between the last clean air purge and final hatch closure on the ground and the crew's first entry on orbit. This time can range from a few days to a few months. Typically, triplicate samples are taken at pre‐planned times throughout the test. Samples are then analyzed by gas chromatography and mass spectrometry, and the rate of accumulation of pollutants is then extrapolated over time. The analytical values are indexed against 7‐day spacecraft maximum allowable concentrations (SMACs) to provide a prediction of the total toxicity value (T‐value) at the time of first entry. This T‐value and the toxicological effects of specific pollutants that contribute most to the overall toxicity are then used to guide first entry operations. Finally, results are compared to first entry samples collected on orbit to determine the predictive ability of the ground‐based offgas test.

Meyers, Valerie↗

Determination of 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and -furans at the part per trillion level in United States beef fat using high-resolution gas chromatography/high-resolution mass spectrometry

As part of the U.S. EPA Dioxin Reassessment Program, the 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and furans were measured at part per trillion (ppt) levels in beef fat collected from slaughter facilities in the United States. This is the first statistically designed national survey of these compounds in the U.S. beef supply. Analyte concentrations were determined by high-resolution gas chromatography/high-resolution mass spectrometry, using isotope dilution methodology. Method limits of detection on a whole weight basis were 0.05 ppt for TCDD and 0.10 ppt for TCDF, 0.50 ppt for the pentas (PeCDDs/PeCDFs)/hexas (HxCDDs/HxCDFs)/heptas (HpCDDs/HpCDFs), and 3.00 ppt for the octas (OCDD/OCDF). Method detection and quantitation limits were established on the basis of demonstrated performance criteria utilizing fortified samples rather than by conventional signal-to-noise or variability of response methods. The background subtraction procedures developed for this study minimized the likelihood of false positives and increased the confidence associated with reported values near the detection limits. Mean and median values for each of the 2,3,7,8-Cl-substituted dioxins and furans are reported, along with the supporting information required for their interpretation. The mean toxic equivalence values for the samples are 0.35 ppt (nondetects = 0) and 0.89 ppt (nondetects = 1/2 LOD).

Benzofurans/analysis↗

A method for defining down-wind evacuation areas for transportation accidents involving toxic propellant spills

Evacuation areas for accidental spills of toxic propellants along rail and highway shipping routes are defined to help local authorities reduce risks to people from excessive vapor concentrations. These criteria along with other emergency information are shown in propellant spill cards. The evacuation areas are based on current best estimates of propellant evaporation rates from various areas of spill puddles. These rates are used together with a continuous point-source, bi-normal model of plume dispersion. The rate at which the toxic plume disperses is based on a neutral atmospheric condition. This condition, which results in slow plume dispersion, represents the widest range of weather parameters which could occur during the day and nighttime periods. Evacuation areas are defined by the ground level boundaries of the plume within which the concentrations exceed the toxic Threshold Limit Value (TLV) or in some cases the Emergency Exposure Limit (EEL).

Siewert, R. D.↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

Concentration-time data in toxicity tests and resulting relationships

Periodic analyses for carbon monoxide and methane in the animal exposure chamber during pyrolysis of polyethylene at 800 C without forced air flow showed that the concentrations of these compounds increased with exposure time. These observations, and similar observations for polyurethane flexible foam, permitted the calculation of carbon monoxide toxicity in terms of a DP (Death Product Concentration) value, in addition to flammability in terms of HC (Hydro Carbon) value. Observed DP values exceeding the critical DP(CO) value of 47,200 ppm-min for carbon monoxide may indicate that lethal exposures were reached earlier but not immediately manifested because of the time delay involved in physiological processes. On the basis of this DP(CO) value, carbon monoxide could have been the sole toxicant in the case of polyethylene, polypropylene, polyoxymethylene, polystyrene, polycarbonate, ethylene propylene diene rubber, and wood.

Hilado, C. J.↗

Effect of species on relative toxicity of pyrolysis products

One of the principal factors in animal toxicity studies is the choice of animal species. A limited study of the relative toxicity of the pyrolysis products from cotton and wool indicated that values of concentrations and doses required to produce death in 50% of the test animals obtained with Swiss albino mice were approximately one-half the values obtained with Sprague-Dawley rats. The toxicity of cotton relative to that of wool was the same using Swiss albino mice or Sprague-Dawley rats. Rankings of relative toxicity appear to be more sensitive to differences in apparatus and procedure than to interspecies differences.

Hilado, C. J.↗

Apparent lethal concentrations of pyrolysis products of some polymeric materials

Thirty-nine samples of polymeric materials were evaluated to determine the apparent lethal concentrations of their pyrolysis products. The materials were compared on the basis of the apparent lethal concentration for 50 percent of the test animals. Relative toxicity rankings based o apparent lethal concentration values can differ significantly depending on whether they are based on weight of sample charged or weight of sample pyrolyzed. The ranking of polyphenylene sulfide is particularly sensitive to this difference.

Hilado, C. J.↗

Thermochemical and flammability properties of some thermoplastic and thermoset polymers - A review

The thermochemical and flammability properties of thermoplastic and thermoset polymers are discussed. The results of a thermogravimetric analysis of the polymers conducted on a DuPont 950 thermogravimetric analyzer using both nitrogen and air atmospheres are presented. Experimental data on smoke evolution are given, and the methodology for assessing the relative toxicity of the pyrolysis effluents is described. The values obtained from the flammability tests are compared with the stoichiometric char yield, and it is shown that the ignition tendency of the polymers is a linear function of the resin char yield

Kourtides, D. A.↗

On-Orbit Manufacturing From Orbital Factories to In Situ Resource Utilization

This webinar will review commercial prospects for manufacturing in orbit. Doing business in space is rapidly becoming more reliable, affordable and accessible. From 2010 to 2015 launch prices went down by a factor of 10 or more, to about $5,000kg while investments into Space 2.0 companies and technologies are closing in on $2.5 Billion (New Space Global). With three commercial suppliers (SpaceX, Orbital ATK and Sierra Nevada Corp) to Earths orbits, mission frequency is improving dramatically. Moreover, private space companies (SpaceX Reusable Dragon Lab; Bigelows B330) are also scouting the opportunities of renting or selling modules as platforms for orbital free-flying facilities; modules that can be used for automated fabrication to manned experiments.Topics addressed in the webinar include: 1. Case studies of unique competitive advantages that can be gained from microgravity and space vacuum: wafer reprocessing, fiber optics, crystal growth;2. Prospective solar power orbital data centers;3. Reuse and recycling of orbital debris as a possible feedstock for robotic 3D fabrication potentially in the vacuum as well as inside facilities;4. The story behind the original WakeShield wafer fabrication facility and its relevance to todays activities;5. Energy needs for on-orbit manufacturing6. Environmental value proposition of on-orbit manufacturing for products with toxic byproducts or excessively large green house gases footprints;7. Longer term scenario of flexible, connected, automated, intelligent and sustainable orbital factories of the future.Opening up a less-appreciated aspect of NewSpace, this webinar will be of high interest to CTOs, Directors and Managers from product development to RD, Innovation Strategy leaders, and investors, across many different industrial verticals (materials, electronics, pharmaceuticals, advanced sustainable manufacturing, bioengineering, etc.)and anyone trying to understand what value space can have for their business in the near and far future.

Cozmuta, Ioana↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗

Toxicity of pyrolysis products: Influence of experimental conditions - The MSTL/UT and NASA/JSC Procedures

Ten sample materials of various polymeric composition were evaluated for toxicity of pyrolysis products utilizing two significantly different experimental methods, the MSTL/UT and NASA/JSC Procedures. A comparison of the LD(50) values obtained by the two methods for these ten samples did not yield a significant correlation. However, when the samples were ranked in order of increasing toxicity by each method independently, a comparison of their rank order toxicity improved the correlation. Because of interlaboratory variations in pyrolysis/combustion test procedures, it is suggested a series of standard materials be adopted to facilitate interlaboratory comparisons of data on pyrolysis toxicity.

Lawrence, W. H.↗

Effect of circadian rhythm on CNS oxygen toxicity.

The circadian rhythm in susceptibility to oxygen toxicity seizures was investigated by using six groups of 20 male Sprague-Dawley rats (101-196 gm.). The animals were given standard chow, exposed to standard diurnal conditions of light (0700-1900 hr) and dark (1900-0700 hr), and fasted for 15-16 hr prior to exposure to hyperbaric oxygen. The animals were placed in a previously oxygen flushed chamber and raised to 60 psi (gauge) oxygen at a rate of 3 psi/min. Time of exposure started with attainment of 60 psi. End point was first convulsion. The animals' weights were equally distributed within the groups, and the groups were defined by hour of exposure. Time of exposure in minutes prior to seizure was significantly longer in those exposed at 0700-0800 hr and 1000-1100 hr than in four other groups. There was no relationship between animals' weights and time of exposure to seizures. All R values were negative, and the highest R value was -035. These data suggest a definite circadian rhythm in susceptibility to oxygen toxicity seizures.

Hof, D. G.↗

Health hazards of ultrafine metal and metal oxide powders

Study reveals that suggested threshold limit values are from two to fifty times lower than current recommended threshold limit values. Proposed safe limits of exposure to the ultrafine dusts are based on known toxic potential of various materials as determined in particle size ranges.

Boylen, G. W., Jr.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

Association of particulate air pollution and acute mortality: involvement of ultrafine particles?

Recent epidemiological studies show an association between particulate air pollution and acute mortality and morbidity down to ambient particle concentrations below 100 micrograms/m3. Whether this association also implies a causality between acute health effects and particle exposure at these low levels is unclear at this time; no mechanism is known that would explain such dramatic effects of low ambient particle concentrations. Based on results of our past and most recent inhalation studies with ultrafine particles in rats, we propose that such particles, that is, particles below approximately 50 nm in diameter, may contribute to the observed increased mortality and morbidity In the past we demonstrated that inhalation of highly insoluble particles of low intrinsic toxicity, such as TiO2, results in significantly increased pulmonary inflammatory responses when their size is in the ultrafine particle range, approximately 20 nm in diameter. However, these effects were not of an acute nature and occurred only after prolonged inhalation exposure of the aggregated ultrafine particles at concentrations in the milligrams per cubic meter range. In contrast, in the course of our most recent studies with thermodegradation products of polytetrafluoroethylene (PTFE) we found that freshly generated PTFE fumes containing singlet ultrafine particles (median diameter 26 nm) were highly toxic to rats at inhaled concentrations of 0.7-1.0 x 10(6) particles/cm3, resulting in acute hemorrhagic pulmonary inflammation and death after 10-30 min of exposure. We also found that work performance of the rats in a running wheel was severely affected by PTFE fume exposure. These results confirm reports from other laboratories of the highly toxic nature of PTFE fumes, which cannot be attributed to gas-phase components of these fumes such as HF, carbonylfluoride, or perfluoroisobutylene, or to reactive radicals. The calculated mass concentration of the inhaled ultrafine PTFE particles in our studies was less than 60 micrograms/m3, a very low value to cause mortality in healthy rats. Aging of the fumes with concomitant aggregation of the ultrafine particles significantly decreases their toxicity. Since ultrafine particles are always present in the urban atmosphere, we suggest that they play a role in causing acute lung injury in sensitive parts of the population.

NASA Discipline Environmental Health↗

Toxicology

Oxygen toxicity is examined, including the effects of oxygen partial pressure variations on toxicity and oxygen effects on ozone and nitrogen dioxide toxicity. Toxicity of fuels and oxidizers, such as hydrazines, are reported. Carbon monoxide, spacecraft threshold limit values, emergency exposure limits, spacecraft contaminants, and water quality standards for space missions are briefly summarized.

Macewen, J. W.↗

Development of an advanced rocket propellant handler's suit

Most launch vehicles and satellites in the US inventory rely upon the use of hypergolic rocket propellants, many of which are toxic to humans. These fuels and oxidizers, such as hydrazine and nitrogen tetroxide have threshold limit values as low as 0.01 PPM. It is essential to provide space workers handling these agents whole body protection as they are universally hazardous not only to the respiratory system, but the skin as well. This paper describes a new method for powering a whole body protective garment to assure the safety of ground servicing crews. A new technology has been developed through the small business innovative research program at the Kennedy Space Center. Currently, liquid air is used in the environmental control unit (ECU) that powers the propellant handlers suit (PHE). However, liquid air exhibits problems with attitude dependence, oxygen enrichment, and difficulty with reliable quantity measurement. The new technology employs the storage of the supply air as a supercritical gas. This method of air storage overcomes all of three problems above while maintaining high density storage at relatively low vessel pressures (<7000 kPa or approximately 1000 psi). A one hour prototype ECU was developed and tested to prove the feasibility of this concept. This was upgraded by the design of a larger supercritical dewar capable of holding 7 Kg of air, a supply which provides a 2 hour duration to the PHE. A third version is being developed to test the feasibility of replacing existing air cooling methodology with a liquid cooled garment for relief of heat stress in this warm Florida environment. Testing of the first one hour prototype yielded data comparable to the liquid air powered predecessor, but enjoyed advantages of attitude independence and oxygen level stability. Thermal data revealed heat stress relief at least as good as liquid air supplied units. The application of supercritical air technology to this whole body protective ensemble marked an advancement in the state-of-the-art in personal protective equipment. Not only was long duration environmental control provided, but it was done without a high pressure vessel. The unit met human performance needs for attitude independence, oxygen stability and relief of heat stress. This supercritical air (and oxygen) technology is suggested for microgravity applications in life support such as the Extravehicular Mobility Unit. c 2001. Elsevier Science Ltd. All rights reserved.

Hazardous Substances↗