Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Integrated Framework for Memory-Centric Analysis: From Trace Collection to Co-Design

The memory wall phenomenon—where advances in processor performance significantly outpace those in memory subsystems—poses a fundamental challenge for contemporary computing systems. In memory-bound applications, memory subsystem behavior dominates performance, yet existing analysis approaches present significant limitations: detailed microarchitectural simulators require days to weeks to simulate modest workloads; hardware performance counters provide only aggregate statistics that obscure temporal and spatial access patterns; and scaled simulation approaches face challenges in capturing certain behaviors that emerge at larger scales. These limitations reflect a processor-centric design philosophy increasingly misaligned with memory-bound workloads where detailed understanding of memory access patterns, cache hierarchy interactions, and contention is critical for effective optimization. This paper presents an integrated framework for memory-centric analysis that enables effective hardware-software co-design. We describe practical trace collection techniques, including hardware-assisted processor tracing with minimal overhead and portable software-based instrumentation with statistical sampling. We present multi-perspective analysis methods that examine memory behavior from temporal, sequential, spatial, and relational viewpoints, revealing distinct optimization opportunities invisible in aggregate metrics. We detail an architectural modeling framework that uses sampled traces with temporal interpolation and confidence-based filtering to evaluate cache and memory configurations. Evaluation on representative benchmarks demonstrates that this framework achieves practical accuracy (L2 cache errors of 2.64\%, confidence-filtered L3 errors of 9.92\%, bandwidth errors of 7.33\%) while providing substantial speedup (26.8×) over cycle-accurate simulation, enabling rapid design space exploration. We demonstrate how this integrated framework enables systematic identification of both hardware optimizations (memory controller tuning, bank partitioning, NUMA configuration) and software optimizations (data layout restructuring, prefetching strategies, memory-aware scheduling). Through this comprehensive treatment of the memory-centric analysis pipeline—from trace collection through architectural modeling to co-design application—we provide researchers and practitioners with practical techniques for addressing memory bottlenecks in contemporary computing systems.

Gajaria, Dhruv Mayur↗

Single particle trace element analysis of uranium oxide standards with laser-induced breakdown spectroscopy

Femtosecond Laser-Induced Breakdown Spectroscopy (LIBS) was used to analyze over 1000 individual particles of uranium oxide trace element standard CRM124. Intra-granular analysis showed elemental concentrations were consistent across different surface locations on each uranium grain. However, inter-granular comparison revealed large heterogeneity between different grains of the same sample. By comparing the distribution of elemental concentrations across the particle populations, we were able to correctly identify a manufacturing process involving wet chemistry, rather than a dry mixing of two powders to give an overall chemical average. In conclusion, this demonstrates the utility of LIBS as a large-scale single particle analysis tool for nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Reproducibility of Radiokrypton in Deep Desert Aquifers: Insights from a Decade of Research

Great technical advances have been achieved since the first atom-trap trace analysis (ATTA) -based radiokrypton application in Egypt, where 1 Myr old groundwater was discovered. Beyond advances in ATTA measurement capabilities, including reduction in sample size, analysis duration, and analytical uncertainty, major progress has been achieved over the past two decades in the sample collection and preparation techniques. These advances paved the expansion of ATTA-based noble gas applications to many other aquifers worldwide, illuminating the nature and flow pattern of deep groundwater systems. While the potential of this new analytical technique for old groundwater dating is well recognized, another important aspect yet to be examined is the reproducibility of radiokrypton in aquifers over time, i.e., how representative is a discrete groundwater sample, collected at a specific time and location, for the natural groundwater system? The likelihood of a negative answer is increased by flow-field disturbance in aquifers following massive groundwater abstraction. Here, in this work, we present repeated 81 Kr sampling and measurements in twenty-one sites over Israel, mostly of deep (up to 1 km) wells tapping confined aquifers in the arid to hyperarid Negev desert. The results demonstrate that radiokrypton measurements are indeed reproducible, even in cases where samples were collected as long as nine years apart and from highly productive (∼1 Mm 3 /yr order) pumping wells. Furthermore, many of the repeated measurements in this study (17 out of the 21 sites) were conducted with different ATTA Instruments in two different laboratories using slightly different sampling, preparation, and analysis techniques, yet with an overall good agreement. The consistency in the ATTA-based 81 Kr-dating results over time highlights the robustness of this state-of-the-art technique as a tool to unravel groundwater flow patterns and encourages further applications to many other yet-to-be-explored deep aquifers.

atom-trap trace analysis↗

In-situ observations of cyclic deformation in an extruded Mg-2Nd-1Y-0.1Zr-0.1Ca alloy

In this study, the evolution of deformation mechanisms during cyclic loading in an extruded, solution-treated Mg–2Nd–1Y–0.1Zr–0.1Ca alloy was investigated using a combination of in-situ loading, scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and focused ion beam (FIB) nanofabrication. The initial microstructure exhibited a random crystallographic texture with no preferred grain orientation. Flat, rectangular dog-bone specimens were subjected to load-controlled, fully reversed fatigue for 50 cycles, during which the same region was sequentially mapped to track microstructural changes. After 10 cycles of loading deformation twins were observed. During tensile reloading detwinning or narrowing of those twinned regions occurred. After 20 cycles, detwinning ceased and residual twins remained in the material. SEM imaging revealed numerous surface slip traces after cyclic loading. EBSD-assisted slip trace analysis identified the activation of prismatic and pyramidal < c+a> slip systems during low-cycle fatigue. Site-specific scanning transmission electron microscopy (STEM) further revealed that deformation was also accommodated by basal < a> slip and the dissociation of < c+a> dislocations. Center-of-symmetry (COS) analysis confirmed that the dissociation of < c+a> dislocations resulted in the formation of I₁ intrinsic stacking faults after cyclic loading. These findings provide new insights into the complex interplay of dislocation mechanisms governing fatigue deformation in rare-earth-containing Mg alloys.

Cyclic deformation↗

Vacuum-ultraviolet light source for enhanced production of metastable krypton and xenon beams

Here, we demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.

Metastable noble gases↗

Performance analysis and data reduction for exascale scientific workflows

Chimbuko is the first in situ, scalable, workflow-level performance analysis tool for trace-level analysis and visualization of application performance. This tool was developed by the Co-design Center for Online Data Analysis and Reduction and funded by the U.S. Department of Energy’s Exascale Computing Project. We provide a detailed description of Chimbuko’s architecture and illustrate our online and offline visualization with multiple use cases. We also present results for the deployment and scalability of the tool as applied to a high-energy physics workflow running at large scale on the Frontier supercomputer.

97 MATHEMATICS AND COMPUTING↗

Nuclear forensic analysis on uranium ore concentrates: A multi-laboratory intercomparison study

A collaboration between the United States and Japan performed nuclear forensic analyses on a set of 7 uranium ore concentrate (UOC) samples with known origins to improve methodologies and best practices in the field. Overall, good agreement between the 4 participating laboratories was achieved for uranium assay, uranium isotope composition, strontium isotope composition, and trace element analysis. In conclusion, the combination of these four signatures is sufficient to distinguish the different origins among these studied UOCs.

and nuclear chemistry↗

High-Burnup BWR LOCA Burst Analysis Using High-Fidelity Multiphysics Simulations

The US nuclear industry is looking to improve on the operating economics of the current fleet of light-water reactors (LWRs). One way of achieving this is by operating fuel to higher burnup. In pressurized water reactors (PWRs), relaxing the current burnup limit will allow for cycle length extensions and power uprates; in boiling water reactors (BWRs) it may allow for improved fuel utilization and reduced feed assemblies, as well as more efficient power uprates and increased capacity factors that will support the Administration’s Executive Order to facilitate 5 GW of power uprates at existing nuclear facilities. However, one of the key limitations to operating fuel to higher burnup is the risk of fuel fragmentation, relocation, and dispersal (FFRD). Recognizing the high interest in extending burnup limits, the US Nuclear Regulatory Commission (NRC) has issued Draft Regulatory Guide DG-1434, which defines an approach that would be acceptable to the NRC for addressing FFRD risk. The approach defined will require better understanding of the phenomena leading to FFRD as well as best-estimate simulation methods to understand FFRD risk in high-burnup cores. The Nuclear Energy Advanced Modeling and Simulation program is supporting the FFRD industry challenge problem through development of state-of-the-art, high-fidelity modeling and simulation LWR analysis capabilities; namely, the BISON fuel performance code and the VERA core simulator software. These tools, along with the US NRC TRACE system analysis code, have been utilized for analysis of FFRD risk in both PWR and BWR cores in recent years. The work documented in this report addresses the lack of high-fidelity research for BWRs and builds on a previous activity where the framework has been applied to Cycles 16 through 18 of Limerick Unit 1, a BWR/4, with introduction of 8 high-burnup lead use assemblies (HBLUAs) that were representative of the 8 HBLUAs loaded into Limerick Unit 2 in 2021. VERA was used in this previous activity to model rod-by-rod depletion in these cycles, and its solution was used to initialize a TRACE simulation of a large-break loss-of-coolant accident (LBLOCA) at the end of Cycle 18. In the work documented in this report, the TRACE model was improved by refining the core mesh and utilizing a new feature that allows for capturing the full 3D VERA power distribution in the model. This allows for a more detailed solution for setting BISON boundary conditions. Furthermore, the solutions from VERA and TRACE were used to set up and perform BISON simulations of about 1,000 rods sampled from the core, including all burnup levels. Utilizing two cladding burst models, it was shown that no fuel rods were predicted to burst during the postulated LBLOCA transient. Additionally, a sensitivity study was performed by artificially increasing linear heat rate during the postulated LBLOCA to identify parameters that correlate with rod burst susceptibility. Burnup, fission gas release, and hoop strain were all found to be positively correlated with rod burst susceptibility. Small-break loss-of-coolant accident (SBLOCA) analyses were also performed; these analyses predicted cladding temperature increases that were bounded by the LBLOCA cladding temperatures for all small break sizes studied for this plant. However, future refinements to the plant response assumptions during the SBLOCA could impact the predicted cladding response. Finally, a benchmark study was performed between CTF and TRACE for LOCA conditions to better qualify CTF for BWR LOCA modeling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A realistic TRACE PWR LOCA model with application to high-burnup analysis

This paper presents a TRACE model of a postulated large-break loss-of-coolant accident (LBLOCA) event in a four-loop pressurized water reactor (PWR). The input files have been made publicly available and serve as a starting point for researchers to improve upon or apply to their purposes. The model, based on a legacy PWR model, contains numerous improvements and modifications consistent with US Nuclear Regulatory Commission LBLOCA analysis guidelines. The model is applied to analyze high-burnup (>62 GWD/MTU) fuel behavior during LBLOCA, improving on previous work to provide realistic thermal hydraulic predictions for future fuel performance analyses and experiments related to fission fragment, relocation, and dispersal (FFRD). Sensitivity studies are presented to quantify the impact of the vessel-modeling approach, core radial discretization, and other phenomena. In conclusion, the model is intended for research purposes and contains sufficient plant geometric, operational, and safety system details to represent the main physical phenomena pertaining to LBLOCA.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep desert aquifers as an archive for Mid- to Late Pleistocene hydroclimate: An example from the southeastern Mediterranean

Many efforts have been made to illuminate the nature of past hydroclimates in semi-arid and arid regions, where current and future shifts in water availability have enormous consequences on human subsistence. Deep desert aquifers, where groundwater is stored for prolonged periods, might serve as a direct record of major paleo-recharge events. To date, groundwater-based paleoclimate reconstructions have mainly focused on a relatively narrow timescale (up to ∼40 kyr), limited by the relatively short half-life of the widely used radiocarbon (5.73 kyr). Here we demonstrate the usage of deep regional aquifers in the arid southeastern Mediterranean as a hydroclimate archive for earlier Mid-to-Late Pleistocene epochs. State-of-the-art dating tools, primarily the 81 Kr radioisotope (t 1/2 = 229 kyr), were combined with other atmosphere-derived tracers to illuminate the impact of four distinguishable wetter episodes over the past 400 kyr, with differences in climatic conditions and paleo-recharge locations. Variations in stable water isotope composition suggest moisture transport from more proximal (Mediterranean) and distal (Atlantic) sources to different parts of the region at distinct times. Large variability in the computed noble gas-based recharge temperature (NGT), ranging ~15–30 °C, cannot be explained by climate variations solely, and points to different recharge pathways, including geothermal heating in the deep unsaturated zone and recharge from high-elevation (colder) regions. The obtained groundwater record complements and enhances the interpretation of other terrestrial archives in the arid region, including a contribution of valuable information regarding the moisture source origin as reflected in the deuterium-excess values, which is unattainable from the common practice analysis of calcitic cave deposits. We conclude that similar applications in other deep (hundred-m-order) regional groundwater systems (e.g., the Sahara desert aquifers) can significantly advance our understanding of long-term (up to 1 Myr) paleo-hydroclimate in arid regions, including places where no terrestrial remnants, such as cave, lake, and spring sediments, are available.

Atom Trap Trace Analysis↗

High-gradient magnetic filtration of UO 2 colloids from aqueous suspensions

Environmental samples often contain innocuous components that make trace actinide analysis difficult and expensive. Therefore, it is expedient to separate these materials from actinide particles. One characteristic of many actinides is that they are paramagnetic. High-gradient magnetic filtration (HGMF) is a non-destructive technique that selectively captures magnetic constituents from a matrix containing non-magnetic species. Here, in this work, a novel HGMF device made of a permanent magnet array was used to effectively separate UO 2 particles from undesirable soil species. Up to 88% of the UO 2 particles present in suspensions were effectively captured by HGMF, resulting in their enrichment and a substantial reduction in the concentrations of other constituents.

Actinide separations↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗