Results for “trace element detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation and Specifications for In-Line Uranium Separations Using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) Detection for Trace Elemental Analysis

Automated introduction platforms integrated with inductively coupled plasma optical emission spectroscopy (ICP-OES) systems are continuously being improved. Expanding on the introduction systems, a newly developed automated ion chromatography system was explored for performing rapid in-line separations coupled to ICP-OES for the detection of trace elements in uranium. Trace elements are separated from a uranium material and the analytes are directed into the ICP-OES for subsequent detection. Detection parameters such as exposure time frequency, wavelength selection, and settling times were explored to gain insight on optimal detection schemes for in-line trace elemental analysis. The methodology was applied in the analysis of a uranium oxide (U3O8) certified reference material, CRM-124. It was found here that the sensitivity and uncertainty of the technique are greatly affected by how the ICP-OES is employed to collect data. Overall it was determined that faster exposure replicates can provide greater peak resolution with higher fidelity measurements but are limited with respect to the total analysis time (i.e., limited in detection timely separations). In conclusion zeta scores, which combine accuracy and uncertainty of certified values and experimental values, were used to validate the ICP-OES modes of operation.

47 OTHER INSTRUMENTATION↗

Optimizing detector geometry for trace element mapping by X-ray fluorescence

Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Laser Induced Breakdown in Air in Conjunction with Atomic Absorption Spectroscopy for Detection of Trace Elements in Fennel Seeds

A robust approach of laser-induced breakdown spectroscopy (LIBS) in ambient air has been employed to investigate concentration of the trace elements in fennel seeds (saunf) via generation of plasma through the second harmonic of solid state Nd: YAG pulsed laser 532 nm. Spectral emissions of saunf plasma were acquired with resolution of 0.06 nm in spectral range of 200–720 nm. The experimental determination showed the existence of elements namely, Ca, Al, K, Fe, S, P, Mg, Mn, Sr, Na, and Zn in the sample. However, no toxic elements such as Pb, Cr etc. were perceived. The relative concentrations of detected elements were measured through the intensity of the strongest peak, intensities of every emission from every specie, and calibration free (CF)-LIBS. To indorse the experimental determinations of LIBS, a comparative study was carried out with the outcomes of atomic absorption spectroscopy (AAS). The results of LIBS and AAS were compared by the statistical treatment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Defect detection inside superconducting 1.3 GHz cavities by means of x-ray fluorescence spectroscopy

X-ray fluorescence probe for detection of foreign material inclusions on the inner surface of superconducting cavities has been developed and tested. The setup detects trace element content such as a few micrograms of impurities responsible for thermal breakdown phenomena limiting the cavity performance. The setup has been customized for the geometry of 1.3 GHz TESLA-type niobium cavities and focuses on the surface of equator area at around 103 mm from the centre axis of the cavities with around 20 mm detection spot. More precise localization of inclusions can be reconstructed by means of angular or lateral displacement of the cavity. Preliminary tests confirmed a very low detection limit for elements laying in the high efficiency spectrum zone (from 5 to 10 keV), and a high angular resolution allowing an accurate localization of defects within the equator surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alkali trace elements in Gale crater, Mars, with ChemCam: Calibration update and geological implications

The Chemistry Camera (ChemCam) instrument onboard Curiosity can detect minor and trace elements such as lithium, strontium, rubidium, and barium. Their abundances can provide some insights about Mars' magmatic history and sedimentary processes. We focus on developing new quantitative models for these elements by using a new laboratory database (more than 400 samples) that displays diverse compositions that are more relevant for Gale crater than the previous ChemCam database. These models are based on univariate calibration curves. For each element, the best model is selected depending on the results obtained by using the ChemCam calibration targets onboard Curiosity. New quantifications of Li, Sr, Rb, and Ba in Gale samples have been obtained for the first 1000 Martian days. Comparing these data in alkaline and magnesian rocks with the felsic and mafic clasts from the Martian meteorite NWA7533—from approximately the same geologic period—we observe a similar behavior: Sr, Rb, and Ba are more concentrated in soluble- and incompatible-element-rich mineral phases (Si, Al, and alkali-rich). Correlations between these trace elements and potassium in materials analyzed by ChemCam reveal a strong affinity with K-bearing phases such as feldspars, K-phyllosilicates, and potentially micas in igneous and sedimentary rocks. However, lithium is found in comparable abundances in alkali-rich and magnesium-rich Gale rocks. This very soluble element can be associated with both alkali and Mg-Fe phases such as pyroxene and feldspar. Here, these observations of Li, Sr, Rb, and Ba mineralogical associations highlight their substitution with potassium and their incompatibility in magmatic melts.

58 GEOSCIENCES↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative chemical and structural analyses of two uranium dioxide fuel pellets

Here, a comparative investigation of the trace element, U and Pb isotopic compositions, and structural attributes of two uranium dioxide fuel pellets was conducted for nuclear forensic applications. One fuel pellet consists of natural UO 2 (0.71% 235 U), while the other contains enriched UO 2 (3.98% 235 U). Numerous impurities, including transition metals, lanthanides, and main group elements were detected in both fuel pellets with total trace element contents that vary between 9.77 and 11.37 μg/g. The relative abundances of the transition metal impurities in the natural UO 2 fuel pellet are linked to the source U ore and provide important insights into its provenance. X-ray fluorescence spectroscopy was utilized to investigate and compare the macro-(cm)-scale distribution of impurities within each of the fuel pellets. In addition, structural properties of the fuel pellets were examined using powder X-ray diffraction (PXRD) and Raman and infrared spectroscopy. Differences in the intensity of the T2 g U-O stretching vibrational mode were observed in the Raman spectra of the fuel pellets. Lastly, Pb isotope ratios were investigated to potentially differentiate between the natural and enriched UO 2 samples and are linked to the process history of these materials.

36 MATERIALS SCIENCE↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Trace Element Analyses of Micron-Size Particles and Statistical Determination of Minimum Detection Limits

Savannah River National Laboratory (SRNL) has developed expertise in producing homogeneous, ca. 1 m-diameter spherical particles of mixed-element components, wherein dopants can be varied from a trace constituent (ppm) to wt.% concentrations. The samples used for this work are nickel-doped cerium oxide microspheres produced by SRNL. They were initially selected as analogs for plutonium-doped uranium oxide particles and analyzed as part of a larger study to evaluate whether electron probe microanalyzers (EPMA) can be used to characterize nuclear materials as an alternative or complementary method to mass spectrometers. The five samples used in this study contained nominal compositions of 0, 0.004, 0.04, 0.4 and 4 wt.% Ni. They were analyzed by both an Agilent 7900 Q-ICP-MS at SRNL and the JEOL JXA8530F Plus EPMA at the University of Minnesota. In addition to EPMA results (calibrated with high-precision Q-ICP-MS analyses) suggesting that the EPMA could address outstanding nuclear material characterization needs, these samples 1) showcase the ability of the EPMA to quantify not just trace concentrations, but trace concentrations in microparticles (1 m diameter, Fig. 1), and 2) offer a unique opportunity to evaluate the methodology for assessing the minimum detection limits of EPMA analyses.

McSwiggen, Peter [JEOL USA, 11 Dearborn Road, Peab↗

Abstract for CRADA between NETL and GlycoSurf, Inc.

The National Energy Technology Laboratory (NETL) and GlycoSurf, Inc. (Participant) will collaborate in the development of novel luminescent sensing materials for rare earth elements using chemically modified surfactants. Rare earth elements are economically critical metals that are used in many technologies relevant to both energy and national defense. Slow and expensive characterization methods for rare earth element analysis are a major pain point for domestic production of these metals; the development of low-cost optical sensing materials and platforms can significantly reduce the time and financial costs associated with rare earth element prospecting and process monitoring. NETL has extensive experience developing inexpensive and compact optical sensors for critical metals such as rare earths. GlycoSurf, Inc. has commercialized high performance surfactants for the selective extraction of rare earth elements in complex environments such as acid mine drainage. By modifying these surfactants with fluorescent functional groups, trace concentrations of rare earths may be detected through a process called “photosensitization,” where the sensing material induces element-specific emission bands that enable different rare earth elements to be detected and distinguished. This project will enable the development of sensing materials capable of selectively detecting trace quantities of valuable rare earths in challenging conditions, including high ionic strength, highly acidic matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging trace element distributions in single organelles and subcellular features

The distributions of chemical elements within cells are of prime importance in a wide range of basic and applied biochemical research. An example is the role of the subcellular Zn distribution in Zn homeostasis in insulin producing pancreatic beta cells and the development of type 2 diabetes mellitus. We combined transmission electron microscopy with micro- and nano-synchrotron X-ray fluorescence to image unequivocally for the first time, to the best of our knowledge, the natural elemental distributions, including those of trace elements, in single organelles and other subcellular features. Detected elements include Cl, K, Ca, Co, Ni, Cu, Zn and Cd (which some cells were supplemented with). Cell samples were prepared by a technique that minimally affects the natural elemental concentrations and distributions, and without using fluorescent indicators.We find it could likely be applied to all cell types and provide new biochemical insights at the single organelle level not available from organelle population level studies.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced Characterization of Wastewaters with a Focus on the Environment & Economics (Final Technical Progress Report)

This project, funded by the U.S. Department of Energy under award DE-FE0032457 and conducted at the University of Illinois at Urbana-Champaign, focused on advancing the characterization of coal combustion residual (CCR) effluents. The primary objectives were to develop analytical methods for detecting major cations, anions, trace metals, and rare earth elements (REEs) in CCR wastewater, assess environmental impacts, and explore opportunities for resource recovery. The project advanced the development of a "One-Shot" analysis system designed to simultaneously analyze multiple analytes in CCR effluents.

01 COAL, LIGNITE, AND PEAT↗

Low-cost, portable optical sensors for critical mineral prospecting and process monitoring

A combination of projected demand increases for economically critical minerals and a monopolistic global marketplace for these minerals has caused concern over supply chain vulnerabilities, which would impact energy, national defense, and advanced technology production. Domestic production of critical minerals is hindered by expensive and non-portable methods for analyzing metal concentration, which is vital both for resource prospecting and process monitoring. Here, a suite of luminescent materials along with portable instrumentation is presented for fluorescence-based detection of trace concentrations of critical minerals (cobalt, rare earth elements, and aluminum) as well as common gangue metals that are removed during processing (iron and aluminum). A metal-organic framework comprised of zinc, adenine, and trimesic acid immobilized on a fiber optic tip is capable of sensing part-per-billion concentrations of terbium, europium, dysprosium, and samarium through a sensitization approach, in which individual elements produce characteristic emission bands enabling multiple rare earths to be simultaneously detected and distinguished. A deep-UV light emitting diode is used as the excitation source, while a portable spectrometer is used to detect the emitted light. A similar optical set-up is coupled with two different carbon dot materials, which can detect low part-per-million concentrations of cobalt and iron in acidic environments. Metal-organic framework thin films comprised of copper and 2-aminoterephthalic acid are used in tandem with a portable optical set-up to further detect aluminum, with successful deployment in real fly ash leachates. Taken together, these technologies provide an inexpensive and sensitive path towards characterizing economically critical metals.

characterization and extraction of rare earth elem↗

Ambient vapor sampling and selective cluster formation for the trace detection of tributyl phosphate via atmospheric flow tube mass spectrometry

In addition to serving as an f-element ligand and rare-earth method complexing agent, tributyl phosphate (TBP) is a compound containing core functional groups that mimic those routinely found in degradation products from industrial processes. Because detection of trace quantities of TBP can provide insight into the routes of contamination and degradation in the environment, there is a need to develop methods capable of detecting trace quantities of TBP. Vapor detection at atmospheric pressure is one approach that is both sensitive and rapid. We present here the use of atmospheric flow tube mass spectrometry (AFT-MS) for the ambient vapor sampling of TBP from headspace of ppb-level solutions in methanol. Gas phase clustering reactions were to enhance detection levels via the addition of small quantities of the dopants diethylamine (DEA), triethylamine (TEA), and pinacolyl methylphosphonate (PMP) in the vapor stream. Detection of the TBP vapor emanating from these solutions demonstrated a linear range for the protonated TBP species of 1-1000 ppb from solution. The clusters of TBP with DEA, TEA, and PMP each yielded linear ranges of 1-250 ppb for TBP in solution. Despite smaller linear ranges, the addition of these dopant species added a layer of analytical selectivity and reduced variability in signals from quality control samples. These data were obtained using an AFT source coupled to a linear ion trap mass spectrometer, which demonstrates the applicability of trapping systems to the AFT ionization technique while monitoring positive ions.

Ambient vapor sampling, Dielectric barrier dischar↗

Elemental analysis of different varieties of rice samples using XRF technique

Rice is most consumed staple food in the world providing over 21% of the calorie intake of world’s population having high yielding capacity. Elements detected in rice are Al, As, Br, Cd, Cl, Co, Cs, Cu, Fe, Hg, K, Mg, Mn, Mo, Rb, Se and Zn by using Instrumental Neutron Activation with k0 standardization (R. Jayasekera etal,2004). Some of these trace elements are C, H, O, N, S, Ca, P, K, Na, Cl, Mn, Ti, Mg, Cu, Fe, Ni, Si and Zn are essential for growth of human physique The deficiency or excess of these elements in food is known to cause a variety of malnutrition or health disorders in the world. Every year, various varieties of rice are launched by Punjab Agriculture University, Ludhiana. The main purpose of which is to increases the yield to attain the maximum profit. But this leads to changing the elemental concentration in them, which may affect the human health according to variation in the nutrition values. The main objective is to study the presence of elemental concentration in various varieties of rice using EDXRF technique.

60 APPLIED LIFE SCIENCES↗