Search NASA⌕ Search

SEARCH · Search NASA

Results for “tracking detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Search for anomalons using plastic nuclear track detectors

A stack of CR39 track detectors containing Ag foils was exposed to 1.7 GeV/nucleon Fe-56 beam and the anomalous mean free path effect investigated. Neither the whole set of 7517 nor a subset of 2542 interacting fragments produced probably in the Ag target show an effect. By combining the data of this and an earlier experiment we can also exclude an effect for 3219 interacting fragments produced in delta Z=1 collisions.

Heinrich, W.↗

The Nagoya cosmic-ray muon spectrometer 3, part 2: Track detector

The twelve wide gap spark chambers were utilized as the track detectors of the Nagoya cosmic-ray muon spectrometer not only to obtain the precise locations of particles, but also to get some information about the correspondences between segments of trajectories. The area of each chamber is 150 x 70 sq cm and the width of a gap is 5 cm. The gas used is He at the atmospheric pressure. Each three pairs of them are placed on both sides of the deflection magnet. All images of sparks for each event are projected through the mirror system and recorded by two cameras stereoscopically. The mean detection efficiency of each chamber is 95 + or - 2% and the spacial resolution (jitter and drift) obtained from the prototype-experiment is 0.12 mm. Maximum detectable momentum of the spectrometer is estimated at about 10 TeV/c taking into account these characteristics together with the effects of the energy loss and multiple Coulomb scattering of muons in the iron magnet.

Shibata, S.↗

Incident angle dependence of proton response of CR-39 (TS-16) track detector

The proton response of the TS-16 type of CR-39 plastic nuclear track detector has been studied with accelerated and fast neutron induced protons in vacuum and in air. The diameters of etched tracks were measured as a function of etching time and the etch rate ratio and the etch induction layer were determined from the growth curve of the diameter using a variable etch rate ratio model. In the case of the accelerated protons in vacuum an anomalous incident angle dependence of the response is observed.

Radiation Monitoring/instrumentation↗

Charge, energy and LET spectra of high LET primary and secondary particles in CR-39 plastic nuclear track detectors of the P0006 experiment

We have measured the charge, energy and linear energy transfer (LET) spectra of about 800 high LET (LET(sub infinity) H2O greater than 50 keV/micron) particles in CR-39 plastic nuclear track detectors in the P0006 experiment of LDEF. Primary particles with residual range at the reference surface greater than about 2 microns and secondary particles produced in the detector material with total range greater than about 4 microns were measured. We have used a multi-etch technique and an internal calibration to identify and measure the energy of the particles at the reference surface. The LET spectrum was obtained from the charge and energy distribution of the particles.

Csige, I.↗

Automated scanning of plastic nuclear track detectors using the Minnesota star scanner

The problems found in an attempt to adapt an automated scanner of astronomical plates, the Minnesota Automated Dual Plate Scanner (APS), to locating and measuring the etch pits produced by ionizing particles in plastic nuclear track detectors (CR-39) are described. A visual study of these pits was made to determine the errors introduced in determining positions and shapes. Measurements made under a low power microscope were compared with those from the APS.

Fink, P. J.↗

A new method for internal calibration of nuclear track detectors

A new technique is proposed for an internal calibration of a two-layer detector assembly. Spatially coincident pairs of conical tracks on one surface and overetched tracks on the adjacent surface are selected for measurement. Both the etch rate ratio and the particle range can be obtained from the minor and major diameters of the elliptical track and the radii of the circular tracks for two etching steps. This technique was applied to CR-39 detectors exposed to fast neutrons and those flown on a high altitude balloon in order to evaluate the proton response. An improvement by using multi-step etching was also carried out. It was found that not only a single set of the etch rate ratio and the range but also the response curve could be estimated in an extended region by analyzing combined growth curves.

NASA Discipline Radiation Health↗

On particle track detectors

Aqueous sodium hydroxide is widely used to develop charged particle tracks in polycarbonate film, particularly Lexan. The chemical nature of the etching process for this system has been determined. A method employing ultra-violet absorbance was developed for monitoring the concentration of the etch products in solution. Using this method it was possible to study the formation of the etching solution saturated in etch products. It was found that the system super-saturates to a significant extent before precipitation occurs. It was also learned that the system approaches its equilibrium state rather slowly. It is felt that both these phenomena may be due to the presence of surfactant in the solution. In light of these findings, suggestions are given regarding the preparation and maintenance of the saturated etch solution. Two additional research projects, involving automated techniques for particle track analysis and particle identification using AgCl crystals, are briefly summarized.

Benton, E. V.↗

Large Silver Halide Single Crystals as Charged Particle Track Detectors

The trajectory of the particle is made visible under a microscope by the accumulation of metallic silver at regions of the lattice damaged by the particle. This decoration of the particle track is accomplished by exposure of the crystal to light. The decoration of normally present lattice imperfections such as dislocations can be suppressed by the addition to the crystal of less than ten parts per million of a suitable polyvalent metal impurity. An account of some preliminary attempts to grow thin single crystals of AgCl is given also, and suggestions for a more refined technique are offered.

Kusmiss, J. H.↗

Cosmic ray positron research and silicon track detector development

The purpose was to conduct research on: (1) position sensing detector systems, particularly those based upon silicon detectors, for use in future balloon and satellite experiments; and (2) positrons, electrons, proton, anti-protons, and helium particles as measured by the NASA NMSU Balloon Magnet Facility.

Jones, W. Vernon↗

Frequency-Tracking-Error Detector

Frequency-tracking-error detector compares average period of output signal from band-pass tracking filter with average period of signal of frequency 100 f(sub 0) that controls center frequency f(sub 0) of tracking filter. Measures difference between f(sub 0) and frequency of one of periodic components in output of bearing sensor. Bearing sensor is accelerometer, strain gauge, or deflectometer mounted on bearing housing. Detector part of system of electronic equipment used to measure vibrations in bearings in rotating machinery.

Randall, Richard L.↗

Scintillator-fiber charged-particle track-imaging detector

A scintillator-fiber charged-particle track-imaging detector has been developed using a bundle of square cross-section plastic scintillator fiber optics, proximity focused onto an image intensified Charge Injection Device (CID) camera. Detector to beams of 15 MeV protons and relativistic Neon, Manganese, and Gold nuclei have been exposed and images of their tracks are obtained. This paper presents details of the detector technique, properties of the tracks obtained, and range measurements of 15 MeV protons stopping in the fiber bundle.

Binns, W. R.↗

Scintillator-fiber charged particle track-imaging detector

A scintillator-fiber charged-particle track-imaging detector was developed using a bundle of square cross section plastic scintillator fiber optics, proximity focused onto an image intensified charge injection device (CID) camera. The tracks of charged particle penetrating into the scintillator fiber bundle are projected onto the CID camera and the imaging information is read out in video format. The detector was exposed to beams of 15 MeV protons and relativistic Neon, Manganese, and Gold nuclei and images of their tracks were obtained. Details of the detector technique, properties of the tracks obtained, and preliminary range measurements of 15 MeV protons stopping in the fiber bundle are presented.

Binns, W. R.↗

Heavy ion measurement on LDEF

The Kiel Long Duration Exposure Facility (LDEF) experiment M0002, mounted on experiment tray E6, was designed to measure the heavy ion environment by means of CR-39 plastic solid state track detectors. The detector stack with a size of 40x34x4.5 cu cm was exposed in vacuum covered by thermal protection foils with a total thickness of approx. 14 mg/sq cm. After etching small samples of the detector foils tracks with Z greater than or = 6 could be easily detected on a background of small etch pits, which were probably produced by secondaries from proton interactions. The LDEF orientation with respect to the magnetic field lines within the South Atlantic Anomaly (SAA) is expected to be constant during the mission. Therefore, the azimuth angle distribution was measured on the detector foils for low energy stopping particles. All detected arrival directions are close to a plane perpendicular to the magnetic field line of -20 deg declination and -40 deg inclination at location 34 deg W and 27 deg S. Together with the steep energy spectrum, this spatial distribution close to the mirror plane in the SAA is an evidence that heavy ions were detected from a radiation belt population.

Beaujean, R.↗

SONTRAC: A solar neutron track chamber detector

The recent detection on the solar maximum mission (SMM) satellite of high energy neutrons emitted during large solar flares has provided renewed incentive to design a neutron detector which has the sensitivity, energy resolution, and time resolution to measure the neutron time and energy spectra with sufficient precision to improve our understanding of the basic flare processes. Over the past two decades a variety of neutron detectors has been flown to measure the atmospheric neutron intensity above 10 MeV and to search for solar neutrons. The SONTRAC (Solar Neutron Track Chamber) detector, a new type of neutron detector which utilizes n-p scattering and has a sensitivity 1-3 orders of magnitude greater than previous instruments in the 20-200 MeV range is described. The energy resolution is 1% for neutron kinetic energy, T sub n 50 MeV. When used with a coded aperture mask at 50 m (as would be possible on the space station) an angular resolution of approx. 4 arc sec could be achieved, thereby locating the sites of high energy nuclear interactions with an angular precision comparable to the existing x-ray experiments on SMM. The scintillation chamber is investigated as a track chamber for high energy physics, either by using arrays of scintillating optical fibers or by optical imaging of particle trajectories in a block of scintillator.

Frye, G. M., Jr.↗