Search NASA⌕ Search

SEARCH · Search NASA

Results for “trajectory measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Shell trajectory measurements from direct-drive implosion experiments

A technique to measure the shell trajectory in direct-drive inertial confinement fusion implosions is presented. The x-ray self emission of the target is measured with an x-ray framing camera. Optimized filtering limits the x-ray emission from the corona plasma, isolating a sharp intensity gradient very near the ablation surface. This enables one to measure the radius of the imploding shell with an accuracy better than 1 {mu}m and to determine a 200-ps average velocity to better than 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating Jupiter’s Gravity Field Using Juno Measurements, Trajectory Estimation Analysis, and a Flow Model Optimization

The upcoming Juno spacecraft measurements have the potential of improving our knowledge of Jupiter’s gravity field. The analysis of the Juno Doppler data will provide a very accurate reconstruction of spatial gravity variations, but these measurements will be very accurate only over a limited latitudinal range. In order to deduce the full gravity field of Jupiter, additional information needs to be incorporated into the analysis, especially regarding the Jovian flow structure and its depth, which can influence the measured gravity field. In this study we propose a new iterative method for the estimation of the Jupiter gravity field, using a simulated Juno trajectory, a trajectory estimation model, and an adjoint-based inverse model for the flow dynamics. We test this method both for zonal harmonics only and with a full gravity field including tesseral harmonics. The results show that this method can fit some of the gravitational harmonics better to the “measured” harmonics, mainly because of the added information from the dynamical model, which includes the flow structure. Thus, it is suggested that the method presented here has the potential of improving the accuracy of the expected gravity harmonics estimated from the Juno and Cassini radio science experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Kinematic analysis of in situ measurement during chemical mechanical planarization process

Chemical mechanical planarization (CMP) is the most widely used planarization technique in semiconductor manufacturing presently. With the aid of in situ measurement technology, CMP tools can achieve good performance and stable productivity. However, the in situ measurement has remained unexplored from a kinematic standpoint. The available related resources for the kinematic analysis are very limited due to the complexity and technical secret. In this paper, a comprehensive kinematic analysis of in situ measurement is provided, including the analysis model, the measurement trajectory, and the measurement time of each zone of wafer surface during the practical CMP process. In addition, a lot of numerical calculations are performed to study the influences of main parameters on the measurement trajectory and the measurement velocity variation of the probe during the measurement process. All the efforts are expected to improve the in situ measurement system and promote the advancement in CMP control system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measures of trajectory ensemble disparity in nonequilibrium statistical dynamics

Many interesting divergence measures between conjugate ensembles of nonequilibrium trajectories can be experimentally determined from the work distribution of the process. Herein, we review the statistical and physical significance of several of these measures, in particular the relative entropy (dissipation), Jeffreys divergence (hysteresis), Jensen-Shannon divergence (time-asymmetry), Chernoff divergence (work cumulant generating function), and Renyi divergence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Explicit simulation of the Brownian rotation of arbitrary shaped aerosol particles using quaternions

The shape of an aerosol particle strongly influences its mass and momentum transfer cross-sections, charging properties, and other physical properties. Here, we present an explicit time-stepping procedure to simulate the rotational Brownian motion of arbitrary shaped aerosol particles by solving Euler’s equation of rotation. A Langevin formulation of the rotation equations is used, wherein Brownian motion due to thermal collisions between a particle and background gas molecules is represented using a stochastic fluctuating torque and fluid resistance is included as a drag torque. To avoid singularities associated with describing the orientation of a shape with Euler angles, we employ a quaternion formulation that leads to first-order stochastic differential equations to describe the evolution of the angular position and angular velocity of a rigid body. We perform all the rotational dynamics calculations in the body-fixed frame of reference attached to the rotating shape whose basis vectors are the normalized eigenvectors of the inertia tensor of the particle. Numerical solutions to rotation under torque-free conditions, damped rotation without Brownian motion, and stochastic rotation for arbitrary shapes are presented and discussed. The presented method enables time-resolved simulation of Brownian rotation for direct comparison with experimentally measured trajectories or statistical measures. The second order accuracy of the used time-stepping procedure places a severe restriction on the timestep that can be used for obtaining accurate results. Animations of presented simulations are included for visualizing rotational motion at various gas pressures. To aid implementation, MATLAB ® codes are also provided. Extension to include translation Brownian motion is straightforward.

Roy, Mrittika↗

Time history prediction of direct-drive implosions on the Omega facility

We present in this article direct-drive experiments that were carried out on the Omega facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. Two different pulse shapes were tested in order to vary the implosion stability of the same target whose parameters, dimensions and composition, remained the same. The direct-drive configuration on the Omega facility allows the accurate time-resolved measurement of the scattered light. We show that, provided the laser coupling is well controlled, the implosion time history, assessed by the “bang-time” and the shell trajectory measurements, can be predicted. This conclusion is independent on the pulse shape. In contrast, we show that the pulse shape affects the implosion stability, assessed by comparing the target performances between prediction and measurement. For the 1-ns square pulse, the measured neutron number is about 80% of the prediction. For the 2-step 2-ns pulse, we test here that this ratio falls to about 20%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hohlraum Designs for High Velocity Implosions on NIF

In this paper, we compare experimental shock and capsule trajectories to design calculations using the radiation-hydrodynamics code HYDRA. The measured trajectories from surrogate ignition targets are consistent with reducing the x-ray flux on the capsule by about 85%. A new method of extracting the radiation temperature as seen by the capsule from x-ray intensity and image data shows that about half of the apparent 15% flux deficit in the data with respect to the simulations can be explained by HYDRA overestimating the x-ray flux on the capsule. The National Ignition Campaign (NIC) point-design target is designed to reach a peak fuel-layer velocity of 370 km/s by ablating 90% of its plastic (CH) ablator. The 192-beam National Ignition Facility laser drives a gold hohlraum to a radiation temperature (T{sub RAD}) of 300 eV with a 20 ns-long, 420 TW, 1.3 MJ laser pulse. The hohlraum x-rays couple to the CH ablator in order to apply the required pressure to the outside of the capsule. In this paper, we compare experimental measurements of the hohlraum T{sub RAD} and the implosion trajectory with design calculations using the code hydra. The measured radial positions of the leading shock wave and the unablated shell are consistent with simulations in which the x-ray flux on the capsule is artificially reduced by 85%. We describe a new method of inferring the T{sub RAD} seen by the capsule from time-dependent x-ray intensity data and static x-ray images. This analysis shows that hydra overestimates the x-ray flux incident on the capsule by {approx}8%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model Predictive Control-Based Trajectory Shaper for Safe and Efficient Adaptive Cruise Control

Recent studies show that commercially-available adaptive cruise control (ACC) systems are string-unstable, indicating that ACC-driven vehicles amplify speed fluctuations from downstream traffic and induce stop-and-go waves. Moreover, it is challenging to revise the original control algorithm of an ACC system to achieve string stability due to its internal complexity and powertrain uncertainties. To achieve desired control performance given a string-unstable ACC system and circumvent revising the original control algorithm, this study proposes a model predictive control-based trajectory shaper (MPC-TS), which only modifies the sensor-measured trajectory information (i.e., position and speed) of the preceding vehicle. The proposed MPC-TS leverages the input shaping technique to generate reference trajectory to improve string stability, while incorporating tracking errors and vehicle acceleration/deceleration magnitude in the MPC cost function and constraining fluctuations of vehicle speed and spacing to ensure desired car-following performance. Numerical experiments validate the control performance of ACC with the proposed MPC-TS in terms of string stability, safety, traffic efficiency, and comfort.

Zhou, Anye↗

TH-EF-BRA-06: A Novel Retrospective 3D K-Space Sorting 4D-MRI Technique Using a Radial K-Space Acquisition MRI Sequence

Purpose: Current retrospective 4D-MRI provides superior tumor-to-tissue contrast and accurate respiratory motion information for radiotherapy motion management. The developed 4D-MRI techniques based on 2D-MRI image sorting require a high frame-rate of the MR sequences. However, several MRI sequences provide excellent image quality but have low frame-rate. This study aims at developing a novel retrospective 3D k-space sorting 4D-MRI technique using radial k-space acquisition MRI sequences to improve 4D-MRI image quality and temporal-resolution for imaging irregular organ/tumor respiratory motion. Methods: The method is based on a RF-spoiled, steady-state, gradient-recalled sequence with minimal echo time. A 3D radial k-space data acquisition trajectory was used for sampling the datasets. Each radial spoke readout data line starts from the 3D center of Field-of-View. Respiratory signal can be extracted from the k-space center data point of each spoke. The spoke data was sorted based on its self-synchronized respiratory signal using phase sorting. Subsequently, 3D reconstruction was conducted to generate the time-resolved 4D-MRI images. As a feasibility study, this technique was implemented on a digital human phantom XCAT. The respiratory motion was controlled by an irregular motion profile. To validate using k-space center data as a respiratory surrogate, we compared it with the XCAT input controlling breathing profile. Tumor motion trajectories measured on reconstructed 4D-MRI were compared to the average input trajectory. The mean absolute amplitude difference (D) was calculated. Results: The signal extracted from k-space center data matches well with the input controlling respiratory profile of XCAT. The relative amplitude error was 8.6% and the relative phase error was 3.5%. XCAT 4D-MRI demonstrated a clear motion pattern with little serrated artifacts. D of tumor trajectories was 0.21mm, 0.23mm and 0.23mm in SI, AP and ML directions, respectively. Conclusion: A novel retrospective 3D k-space sorting 4D-MRI technique has been developed and evaluated on human digital phantom. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

Measurement-based Coherency Identification and Aggregation for Power Systems

In power system model reduction, a high reduction ratio is often desired to handle much more complex power systems. The bottleneck of traditional methods lies in: Coherency identification methods are conservative. Some coherency generators are not detected when system topology or operating points change, because coherency identification depends on system topology or operating points. There are some solitary generators in external systems. These generators do not belong to any coherency group. However, sometimes these solitary generators have little impact on tie-line power flow, and it might be possible to ignore their dynamics in model reduction. But because they do not belong to any coherency group, existing reduction methods cannot handle them well. In order to overcome the first problem, a measurement-based online coherency identification method is presented in this paper. By analyzing post-fault trajectories measured by Phasor Measurement Units (PMUs), coherency generators are identified through principal component analysis. The method can track time-varying system topology and operating points. In order to address the second problem, this paper introduces sensitivity analysis into traditional reduction methods. The sensitivity of tie-line power flow against injected active power of external system generators is derived. Those generators having loose connection with tie-line power are identified through the sensitivity analysis, and their dynamics are ignored by replacing them with negative impedances. We test if the sensitivity, based on static power flow, provides good guidance to reduce the dynamic model. Case studies show that the proposed method can handle well these solitary generators and the reduction ratio can be enhanced through this method. Future work will include generalization of the sensitivity method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WE-G-17A-05: Real-Time Catheter Localization Using An Active MR Tracker for Interstitial Brachytherapy

Purpose: To develop a novel active MR-tracking system which can provide accurate and rapid localization of brachytherapy catheters, and assess its reliability and spatial accuracy in comparison to standard catheter digitization using MR images. Methods: An active MR tracker for brachytherapy was constructed by adding three printed-circuit micro-coils to the shaft of a commercial metallic stylet. A gel phantom with an embedded framework was built, into which fifteen 14-Gauge catheters were placed, following either with parallel or crossed paths. The tracker was inserted sequentially into each catheter, with MR-tracking running continuously. Tracking was also performed during the tracker's removal from each catheter. Catheter trajectories measured from the insertion and the removal procedures using the same micro-coil were compared, as well as trajectories obtained using different micro-coils. A 3D high-resolution MR image dataset of the phantom was acquired and imported into a treatment planning system (TPS) for catheter digitization. A comparison between MR-tracked positions and positions digitized from MR images by TPS was performed. Results: The MR tracking shows good consistency for varying catheter paths and for all micro-coils (mean difference ∼1.1 mm). The average distance between the MR-tracking trajectory and catheter digitization from the MR images was 1.1 mm. Ambiguity in catheter assignment from images due to crossed paths was resolved by active tracking. When tracking was interleaved with imaging, real-time images were continuously acquired at the instantaneous tip positions and displayed on an external workstation. Conclusion: The active MR tracker may be used to provide an independent measurement of catheter location in the MR environment, potentially eliminating the need for subsequent CT. It may also be used to control realtime imaging of catheter placement. This will enable MR-based brachytherapy planning of interstitial implants without ionizing radiation, with the potential to enable dosimetric guidance of catheter placement. We gratefully acknowledge support from the American Heart Association SDG 10SDG2610139, NIH 1R21CA158987-01A1, U41-RR019703, and R21 CA 167800, as well as a BWH Department of Radiation Oncology post-doctoral fellowship support. Li Pan and Wesley Gilson are employees of Siemens Corporation, Corporate Technology. Ravi Seethamraju is an employee of Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Optics reconstruction in the SCL section of the FNAL Linac

The Side-Coupled Linac (SCL) section of the FNAL linac accelerates the beam from 116 MeV to 401.5 MeV, operating at 22-24 mA beam current. Transverse focusing is performed by 32 quadrupoles, and the beam orbit is guided by 19 dipole correctors and measured by 29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings of an upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code TraceWin. A comparison between TraceWin simulations and the beam envelope measured by the 12 wire scanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance and exit of the SCL section will be reported.

Carneiro, Jean-Paul [Fermilab]↗

Optics Reconstruction in the SCL Section of the FNAL Linac

The Side-CoupledLinac (SCL) section oftheFNAL linac acceleratesthe beamfrom 117 MeV to 401.5 MeV, operatingat 22-24mA beam current. Transverse focusing is performedby32 quadrupoles, and the beam orbit is guidedby19dipolecorrectors andmeasuredby29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings o fan upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code Trace Win. A comparison between Trace Win simulations and the beam envelope measured bythe12wirescanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance of the transition section will be reported

Carneiro, Jean-Paul [Fermilab]↗

Comparison of measured and computed radial trajectories of plasma focus devices UMDPF1 and UMDPF0

In published literature, there has been scant data on radial trajectory of the plasma focus and no comparison of computed with measured radial trajectory. This paper provides the first such comparative study. We compute the trajectories of the inward-moving radial shock and magnetic piston of UMDPF1 plasma focus and compare these with measured data taken from a streak photograph. The comparison shows agreement with the measured radial trajectory in terms of average speeds and general shape of trajectory. This paper also presents the measured trajectory of the radially compressing piston in another machine, the UMDPF0 plasma focus, confirming that the computed radial trajectory also shows similar general agreement. Features of divergence between the computed and measured trajectories, towards the end of the radial compression, are discussed. From the measured radial trajectories, an inference is made that the neutron yield mechanism could not be thermonuclear. A second inference is made regarding the speeds of axial post-pinch shocks, which are recently considered as a useful tool for damage testing of fusion-related wall materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WE-G-BRD-02: Characterizing Information Loss in a Sparse-Sampling-Based Dynamic MRI Sequence (k-T BLAST) for Lung Motion Monitoring

Purpose: Rapid MRI is an attractive, non-ionizing tool for soft-tissue-based monitoring of respiratory motion in thoracic and abdominal radiotherapy. One big challenge is to achieve high temporal resolution while maintaining adequate spatial resolution. K-t BLAST, sparse-sampling and reconstruction sequence based on a-priori information represents a potential solution. In this work, we investigated how much “true” motion information is lost as a-priori information is progressively added for faster imaging. Methods: Lung tumor motions in superior-inferior direction obtained from ten individuals were replayed into an in-house, MRI-compatible, programmable motion platform (50Hz refresh and 100microns precision). Six water-filled 1.5ml tubes were placed on it as fiducial markers. Dynamic marker motion within a coronal slice (FOV: 32×32cm{sup 2}, resolution: 0.67×0.67mm{sup 2}, slice-thickness: 5mm) was collected on 3.0T body scanner (Ingenia, Philips). Balanced-FFE (TE/TR: 1.3ms/2.5ms, flip-angle: 40degrees) was used in conjunction with k-t BLAST. Each motion was repeated four times as four k-t acceleration factors 1, 2, 5, and 16 (corresponding frame rates were 2.5, 4.7, 9.8, and 19.1Hz, respectively) were compared. For each image set, one average motion trajectory was computed from six marker displacements. Root mean square error (RMS) was used as a metric of spatial accuracy where measured trajectories were compared to original data. Results: Tumor motion was approximately 10mm. The mean(standard deviation) of respiratory rates over ten patients was 0.28(0.06)Hz. Cumulative distributions of tumor motion frequency spectra (0–25Hz) obtained from the patients showed that 90% of motion fell on 3.88Hz or less. Therefore, the frame rate must be a double or higher for accurate monitoring. The RMS errors over patients for k-t factors of 1, 2, 5, and 16 were.10(.04),.17(.04), .21(.06) and.26(.06)mm, respectively. Conclusions: K-t factor of 5 or higher can cover the high frequency component of tumor respiratory motion, while the estimated error of spatial accuracy was approximately.2mm.

60 APPLIED LIFE SCIENCES↗