Search NASA⌕ Search

SEARCH · Search NASA

Results for “transducer error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Error Correction: a Proposal for a Standard

Some of the errors in transducers such as instrument transformers can be corrected as part of the digital processing for the measurement. The transducer can be characterized on such a way that allows the TEDS of IEEE Std 1451 to transfer the information to the measurement system. A modification would allow the measurement system to perform a high-quality self-calibration whenever a transducer was replaced.

error correction.↗

Simultaneous moisture content and mass flow measurements in wood chip flows using coupled dielectric and impact sensors

An 8-electrode capacitance tomography (ECT) sensor was built and used to measure moisture content (MC) and mass flow of pine chip flows. The device was capable of directly measuring total water quantity in a sample but was sensitive to both dry matter and moisture, and therefore required a second measurement of mass flow to calculate MC. Two means of calculating the mass flow were used: the first being an impact sensor to measure total mass flow, and the second a volumetric approach based on measuring total area occupied by wood in images generated using the capacitance sensor’s tomographic mode. Tests were made on 109 groups of wood chips ranging in moisture content from 14% to 120% (dry basis) and wet weight of 280 to 1100 g. Sixty groups were randomly selected as a calibration set, and the remaining were used for validation of the sensor’s performance. For the combined capacitance/force transducer system, root mean square errors of prediction (RMSEP) for wet mass flow and moisture content were 13.42% and 16.61%, respectively. RMSEP using the combined volumetric mass flow/capacitance sensor for dry mass flow and moisture content were 22.89% and 24.16%, respectively. Either of the approaches was concluded to be feasible for prediction of moisture content in pine chip flows, but combining the impact and capacitance sensors was easier to implement. As a result, in situations where flows could not be impeded, however, the tomographic approach would likely be more useful.

09 BIOMASS FUELS↗

Controlling optical-cavity locking using reinforcement learning

Abstract This study applies an effective methodology based on Reinforcement Learning to a control system. Using the Pound–Drever–Hall locking scheme, we match the wavelength of a controlled laser to the length of a Fabry-Pérot cavity such that the cavity length is an exact integer multiple of the laser wavelength. Typically, long-term drift of the cavity length and laser wavelength exceeds the dynamic range of this control if only the laser’s piezoelectric transducer is actuated, so the same error signal also controls the temperature of the laser crystal. In this work, we instead implement this feedback control grounded on Q-Learning. Our system learns in real-time, eschewing reliance on historical data, and exhibits adaptability to system variations post-training. This adaptive quality ensures continuous updates to the learning agent. This innovative approach maintains lock for eight days on average.

47 OTHER INSTRUMENTATION↗

A high-precision miniaturized rotating coil transducer for magnetic measurements

A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.

06.20.fb/calibration↗

Picosecond magneto-optic thermometry measurements of nanoscale thermal transport in AlN thin films

The thermal conductivity Λ of wide bandgap semiconductor thin films, such as AlN, affects the performance of high-frequency devices, power devices, and optoelectronics. However, accurate measurements of Λ in thin films with sub-micrometer thicknesses and Λ > 100 W m -1 K -1 is challenging. Widely used pump/probe metrologies, such as time–domain thermoreflectance (TDTR) and frequency–domain thermoreflectance, lack the spatiotemporal resolution necessary to accurately quantify thermal properties of sub-micrometer thin films with high Λ. In this work, we use a combination of magneto-optic thermometry and TiN interfacial layers to significantly enhance the spatiotemporal resolution of pump/probe thermal transport measurements. We use our approach to measure Λ of 100, 400, and 1000 nm AlN thin films. We coat AlN thin films with a ferromagnetic thin-film transducer with the geometry of (1 nm-Pt/0.4 nm-Co) x3 /(2 nm-TiN). This PtCo/TiN transducer has a fast thermal response time of <50 ps, which allows us to differentiate between the thermal response of the transducer, AlN thin film, and substrate. For the 100, 400, and 1000 nm thick AlN films, we determine Λ to be 200 ± 80, 165 ± 35, and 300 ± 70 W m -1 K -1 , respectively. We conclude with an uncertainty analysis that quantifies the errors associated with pump/probe measurements of thermal conductivity, as a function of transducer type, thin-film thermal conductivity, and thin-film thickness. Time resolved magneto-optic Kerr effect experiments can measure films that are three to five times thinner than is possible with standard pump/probe metrologies, such as TDTR. This advance in metrology will enable better characterization of nanoscale heat transfer in high thermal conductivity material systems like wide bandgap semiconductor heterostructures and devices.

36 MATERIALS SCIENCE↗

Full circle mechanical dynamic characterization including experimental modal analysis and finite element analysis

During operation, it was observed that a specific mechanical system experienced undesirable vibration and it became necessary to understand and mitigate this phenomenon. This document investigates the tools, methodology, and results of the dynamic characterization of the system. The characterization makes use of the experimental modal analysis (EMA) methods of single input multiple output (SIMO) and single input single output (SISO). The validity of the theory of reciprocity is confirmed to minimize measurement error, cost, and time of repeat testing. Finite element analysis (FEA) is used in choosing transducer and modal impact locations to adequately characterize the system. Single degree of freedom (SDOF) and multiple degree of freedom (MDOF) curve fitting is used to fully characterize the system’s mode shapes and natural frequencies. The EMA characterization results are used to modify and validate the FEA model so that FEA can be used to model potential structural modifications to the system to mitigate the undesirable vibration. Structural modifications are chosen, implemented, and their effectiveness is quantified using EMA. Finally, a qualitative evaluation of the methodology of FEA validation by EMA and tuning of the model to match the experimental results is discussed.

42 ENGINEERING↗

Contoured PPM-EMAT Design for Ultrasonic Communication On Metallic Pipe Channels

Ultrasonic guided waves can be used as the carriers of information in ultrasonic communication for pipe or plate channels. Permanent Periodic Magnet (PPM) Electromagnetic Acoustic Transducer (EMAT) can potentially provide unique capabilities for a communication system as a non-contact transmitter and receiver, which can selectively generate different modes of shear-horizontal (SH) waves. The SH wave shows the potentials in achieving high bitrate without error in ultrasonic communication. However, when a steel pipe is used as the communication channel, especially one with a radius comparable to the size of the transducer, no guided wave signal can be excited or detected by existing PPM-EMAT's with flat coupling surface. In this paper, a 3D printed magnet holder is designed which can shape the magnet array. Also, the transmitter/receiver coils are made of flexible printed circuit which can fit over the curvature of the pipe channels. The contoured PPM-EMAT transmitter and receiver can conform to the surface of the steel pipe channel in order to generate and detect torsional waves. Experimental tests of signal transmission with PPM-EMAT on a 160cm-long stainless steel pipe determine the optimal frequency for communication to be 916KHz. Information transmission experimental results confirm the validity of contoured PPM-EMAT for communication with a bitrate of 5kbps.

Huang, Xin↗

Investigating YAP’s role in Human Mammary Epithelial Cell (HMEC) Immortalization and Cancer Stem Cell (CSC) Phenotype Acquisition during Early Breast Cancer Progression

The malignant aspect of tumorigenesis in breast cancer is initiated when human mammary epithelial cells (HMEC) first immortalize (gain the ability to proliferate indefinitely) and subsequently undergo oncogenic activation. Our laboratory has developed a two-step HMEC immortalization process that we believe accurately models early breast cancer progression. Normal finite pre-stasis HMEC must overcome two distinct senescence barriers to achieve full immortality: stasis (stress-associated senescence) and replicative senescence, respectively. HMEC bypass stasis, and become post-stasis, when errors in the retinoblastoma pathway are present. Replicative senescence, a product of continuously shortening telomeres producing telomere dysfunction, is overcome by the reactivation of telomerase. Our lab has called HMEC that acquire the error allowing telomerase expression conditionally immortal (CI); CI cells may still have low telomerase expression. Full immortality is achieved when sufficient telomerase expression exists to maintain short stable telomeres following a process we have called conversion. The transcriptional coactivator YAP, upregulated in several human cancers, is closely correlated with a variety of oncogenic effects including proliferation and induction of cancer stem cell (CSC) properties. Our preliminary data have shown that YAP-transduced post-stasis HMEC expressed properties of CI cells. Growth curves indicated that some cell lines achieved full immortality; however, these cells had acquired an additional error – amplified expression of c-Myc, an oncogene known to induce telomerase in post-stasis or CI cells. The absence of uniform immortalization in the YAP-transduced cells suggests that YAP causes post-stasis HMEC to become conditionally immortal. This is further supported given that YAP-transduced post-stasis HMEC have decreased levels of the lncRNA MORT and rapidly go through conversion when p53 function is abrogated, well-documented attributes of CI HMEC. Previous studies have also reported that YAP controls the differentiation of breast progenitor cells; as a result, it is likely that YAP plays a role in inducing CSC phenotypes. In this study, we attempt to gain a greater understanding of YAP’s role in HMEC immortalization and induction of CSC properties in early breast cancer progression. We measured gene expression levels and attempted to identify proteins indicative of a CSC phenotype in YAP-transduced post-stasis HMEC. Our initial results did not reveal an association between YAP and HMEC conditional immortality or induction of CSC attributes in the cultures examined. However, using a YAP construct that promotes nuclear localization (where YAP is most active) has led to a potentially promising YAP-derived cell line that we presume to be immortal. We go on to demonstrate that YAP may be acting via non-transcriptional oncogenic roles in our HMEC specimens. Thus, we recommend future studies into YAP and the HMEC immortalization process given that they are promising targets for breast cancer prevention therapies.

Shah, Manav↗

Performance Evaluation of High-Temperature Ultrasonic Communication System

Ultrasonic communication is a technique that allows transmitting information through a solid material such as tubes or bars using high-frequency elastic waves. The communication channels often extend into a high-temperature range in the field of power, oil, or nuclear industry. When the temperature is taken into consideration, the ultrasonic wave propagation through the solid channel is complex and unpredictable. It is necessary to study the influence of temperature on the ultrasonic guided wave to improve ultrasonic communication. In this study, a temperature control system is assembled to adjust the temperature of a steel pipe channel ranging from room temperature to 150 degrees C. The temperature performance evaluation is conducted to estimate the signal-to-noise ratio (SNR) and bit error rate (BER) of transferring the ultrasonic signal. The work aims to develop a reliable ultrasonic communication system in a high-temperature environment. The system temperature can be maintained at 150 degrees C and the LiNbO3 transducers are used as transmitters and receivers. No power amplifier is used in the communication system. The high-temperature ultrasonic communication system (HT-UCS) is feasible at 150 degrees C and can achieve a bit rate of 10 kbps without any error.

HT-UCS↗

Thermoacoustic range verification in the presence of acoustic heterogeneity and soundspeed errors - Robustness relative to ultrasound image of underlying anatomy

Purpose: To demonstrate robustness of thermooacoustic range verification to acoustic heterogeneity and discrepancies between assumed and true propagation speed, i.e., soundspeed errors. Methods: A beam sweeper was used to deliver 250 ns pulses that deposited 0.26 Gy of 16 MeV protons and 2.3 Gy of 60 MeV helium ions into water and oil targets, respectively. Thermoacoustic signals were detected by a 96-channel ultrasound array with a 1-4 MHz sensitivity band (-6 dB), bandpass filtered and backprojected to create thermoacoustic images in the plane of the ultrasound array. The same soundspeed and transducer array were used to estimate range and generate the ultrasound images onto which Bragg peak locations were overlaid. An air-gap phantom that displaced the Bragg peak by 6.5 mm demonstrated accuracy. Robustness to soundspeed errors was demonstrated in a waterbath as the assumed propagation speed scanner setting was altered by +/- 5%. Tissue-mimicking gelatin and a bone sample were introduced to demonstrate robustness to acoustic heterogeneity relative to ultrasound images of the underlying morphology. Results: Single ion pulse measurements sufficed during the helium run, but signal averaging was required for protons. Moreover, range and entry point into the target were estimated from data collected by transducers placed at least 6 cm distal to the Bragg peak. When ultrasound images depicted the air-target interface where the beam enters, estimates of the entry point agreed with ultrasound images and range estimates agreed with Monte Carlo simulations to within 300 mu m, even when thermoacoustic emissions traveled through a strongly scattering bone sample. Estimated Bragg peak locations were translated 6.5 mm by the air-gap phantom and correctly identified scenarios when the beam stopped inside the bone. Conclusions: Soundspeed errors dilate and acoustic heterogeneities deform ultrasound images. When thermoacoustic receivers are co-located with the ultrasound imaging array, the same transformations shift thermoacoustic range estimates. Hence, thermoacoustic range verification is robust relative to ultrasound images of underlying anatomy. When the treatment target is visible in ultrasound, e.g., prostate, online thermoacoustic range estimates could verify that the treatment spot is inside the target.

47 OTHER INSTRUMENTATION↗

Measuring Transverse Displacements Using Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV): Development and Field Validation

Measurement of bridge displacements is important for ensuring the safe operation of railway bridges. Traditionally, contact sensors such as Linear Variable Displacement Transducers (LVDT) and accelerometers have been used to measure the displacement of the railway bridges. However, these sensors need significant effort in installation and maintenance. Therefore, railroad management agencies are interested in new means to measure bridge displacements. This research focuses on mounting Laser Doppler Vibrometer (LDV) on an Unmanned Aerial System (UAS) to enable contact-free transverse dynamic displacement of railroad bridges. Researchers conducted three field tests by flying the Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV) 1.5 m away from the ground and measured the displacement of a moving target at various distances. The accuracy of the UAS-LDV measurements was compared to the Linear Variable Differential Transducer (LVDT) measurements. The results of the three field tests showed that the proposed system could measure non-contact, reference-free dynamic displacement with an average peak and root mean square (RMS) error for the three experiments of 10% and 8% compared to LVDT, respectively. Such errors are acceptable for field measurements in railroads, as the interest prior to bridge monitoring implementation of a new approach is to demonstrate similar success for different flights, as reported in the three results. This study also identified barriers for industrial adoption of this technology and proposed operational development practices for both technical and cost-effective implementation.

42 ENGINEERING↗

Transmission of Images on High-Temperature Nuclear-Grade Metallic Pipe with Ultrasonic Elastic Waves

Transmission of information using elastic ultrasonic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall, with minimal modification of the existing hardware. Because bit rates on the order of kilobits per second are achievable, relatively large volumes of data, such as images, can be transmitted. A viable candidate for an ultrasonic communication channel is a stainless steel pipe of the chemical volume control system (CVCS) that penetrates through the reactor containment building wall through a sealed tunnel. To study ultrasonic communication under simulated nuclear facility conditions of high temperature, a test article was developed by installing heating tapes, temperature controllers, and thermal insulation on a laboratory CVCS-like stainless steel pipe. High temperature and radiation-resilient lithium niobate ultrasonic transducers were utilized for information transmission on the heated pipe. The amplitude shift keying (ASK) digital communication protocol was developed and implemented in a GNU Radio software-defined radio environment. A root-raised-cosine filter was introduced to suppress ultrasonic transducer ringing and thus reduce inter-symbol interference. This resulted in the enhancement of the data transmission bit rate compared to information encoding with square pulses. Demonstrations of communication at high temperature included transmission of a 90-KB image at the bit rate of 10 Kbps with a bit error rate of 10 -3 across a 6-ft-long straight pipe heated up to 230 degrees C. Additional preliminary studies were conducted to evaluate ultrasonic communication system resilience to environmental degradation and damage.

42 ENGINEERING↗

Pulse Shaping and Matched Filters for EMAT Communication System

Electromagnetic acoustic transducer (EMAT) is used as a noncontact sensor for acoustic communication in a stainless-steel plate channel. The acoustic wave multipath propagations within the channel cause intersymbol interference (ISI). ISI highly degrades the signal-to-noise ratio (SNR). The poor SNR will result in a low bitrate and a high bit error rate (BER). In this study, a test platform is designed to estimate the performance of the EMAT communication system. Two periodic-permanent-magnet (PPM) EMATs are designed to be used as a transmitter and a receiver. EMAT generates shear-horizontal (SH) wave propagating through the stainless-steel plate channel. We present methods to minimize the ISI effect and recover the message embedded in the received signals hampered by interference, reverberation and multipath effects. The root raised cosine (RRC) filters are introduced as a pulse-shaping filter for transmission and a matched filter for receiving messages. Amplitude Shift Keying (ASK) method is used for modulating the transmitted binary message. The pulse shaping and matched filters reduced the ISI caused by the undesirable multipath effect significantly to the extent that a 5-kbps bitrate can be achieved without any error (zero BER).

Huang, Xin↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Measuring thermal profiles in high explosives using neural networks

We present a new method for calculating the temperature profile of high explosive (HE) material using a Convolutional Neural Network (CNN). To train/test the CNN, we have developed a hybrid experiment/simulation method for collecting acoustic and temperature data. We experimentally heat cylindrical containers of HE material until detonation/deflagration, where we continuously measure the acoustic bursts through the HE using multiple acoustic transducers lined around the exterior container circumference. However, measuring the temperature profile in the HE in an experiment would require inserting a large number of thermal probes, which would disrupt the heating process. Thus, we use two thermal probes, one at the HE center and one at the wall. We then use numerical simulation of the heating process to calculate the temperature distribution and correct the simulated temperatures based on the experimental center and wall temperatures. We calculate temperature errors on the order of 15 °C, which is ∼12% of the range of temperatures in the experiment. We also investigate how the algorithm’s accuracy is affected by the number of acoustic receivers used to collect each measurement and the resolution of the temperature prediction. This work provides a means of assessing the safety status of HE material, which cannot be achieved using existing temperature measurement methods. In addition, it has implications for a range of other applications where internal temperature profile measurements would provide critical information. These applications include detecting chemical reactions, observing thermodynamic processes such as combustion, monitoring metal or plastic casting, determining the energy density in thermal storage capsules, and identifying abnormal battery operations.

97 MATHEMATICS AND COMPUTING↗

Quantum computer-enabled receivers for optical communication

Abstract Optical communication is the standard for high-bandwidth information transfer in today’s digital age. The increasing demand for bandwidth has led to the maturation of coherent transceivers that use phase- and amplitude-modulated optical signals to encode more bits of information per transmitted pulse. Such encoding schemes achieve higher information density, but also require more complicated receivers to discriminate the signaling states. In fact, achieving the ultimate limit of optical communication capacity, especially in the low light regime, requires coherent joint detection of multiple pulses. Despite their superiority, such joint detection receivers are not in widespread use because of the difficulty of constructing them in the optical domain. In this work we describe how optomechanical transduction of phase information from coherent optical pulses to superconducting qubit states followed by the execution of trained short-depth variational quantum circuits can perform joint detection of communication codewords with error probabilities that surpass all classical, individual pulse detection receivers. Importantly, we utilize a model of optomechanical transduction that captures non-idealities such as thermal noise and loss in order to understand the transduction performance necessary to achieve a quantum advantage with such a scheme. We also execute the trained variational circuits on an IBM-Q device with the modeled transduced states as input to demonstrate that a quantum advantage is possible even with current levels of quantum computing hardware noise.

97 MATHEMATICS AND COMPUTING↗

Magnetostrictive Ultrasonic Waveguide Transducer for In-Pile Thermometry

Real-time and reliable temperature measurement on nuclear fuels is crucial for the safe operation of existing pressurized-water reactors and future advanced nuclear reactors. Magnetostrictive materials deform when subjected to a magnetic field or exhibit magnetization variation when stressed. Here, based on these properties, this study prototyped an ultrasonic thermometer (UT) consisting of a magnetostrictive waveguide, a dc coil providing appropriate magnetic biasing, and an ac coil generating an acoustic impulse and detecting the resulting acoustic echoes. By tracking the time of flight between the excitation pulse and the echoes, the UT can potentially detect nuclear fuel cladding temperature from a long distance. In this study, magnetostrictive iron–gallium alloys, or Galfenol, were selected as the waveguide due to their large magnetostriction, superior temperature survivability, excellent radiation resilience, and high mechanical robustness. A multiphysics finite-element model considering electrical, magnetic, and mechanical dynamics in the magnetostrictive UT was then developed. The model exhibited an error of 0.24% in time-of-flight simulation and, therefore, enabled computer-aided design and guided signal processing. Between room temperature and 120 °C, the new Galfenol-based UT exhibits a linear sensitivity of 162.8×10 ₋6 °C ₋1 , which is 51.7% higher than a previous magnetostrictive UT based on iron–cobalt–vanadium alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report for Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively. Preliminary communication system development was performed using paintbrush PZT transducers capable of continuous operation at temperatures up to 80°C. Next, high-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150°C. Final phase of project development involved investigating strategies for deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗