Search NASASearch

SEARCH · Search NASA

Results for “transfer function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Topography restoration in white-light interferometry using an instrument transfer function evaluated with binary pseudo-random arrays

Accurate knowledge of the instrument transfer function (ITF) is vital for topography measurements using white-light interferometry (WLI). To this end, we derive a complete set of analytical expressions for the power spectral density (PSD) of a discretely sampled binary pseudo-random array (BPRA) as a theoretical benchmark. We then determine the ITF by comparing this theoretical PSD with the measured PSD of the BPRA. For the Zygo ZeGage Pro HR with a objective, the determined ITF closely matches the nominal modulation transfer function (MTF). Accordingly, we integrate the nominal MTF into Fourier-domain restoration filters and apply them to practical WLI topography data, yielding restored topographies that show improved agreement with atomic force microscopy measurements. Overall, our integrated BPRA-based ITF measurement and filtering methodology offers a robust yet practical means of characterizing WLI performance and enhancing the accuracy of surface measurements.

Hirose, Shigenobu [Japan Agency for Marine Earth S

Measuring Magnets Transfer Functions in the NSRL Transport Line

The beamline at the NASA Space Radiation Laboratory (NSRL) is equipped with a range of magnets, including dipole magnets, dipole corrector magnets, quadrupole magnets, sextupole magnets, and octupole magnets. The magnet transfer function defines the relationship between the power supply currents and the corresponding magnet strengths. This note presents the measurements of the transfer functions for the dipole correctors and quadrupole magnet in the NSRL beamline.

43 PARTICLE ACCELERATORS

Fast baryonic field painting for Sunyaev-Zel’dovich analyses: Transfer function vs hybrid effective field theory

Here, we present two approaches for “painting” baryonic properties relevant to the Sunyaev-Zel’dovich (SZ) effect—optical depth and Compton-y—onto three-dimensional N-body simulations, using the MillenniumTNG suite as a benchmark. The goal of these methods is to produce fast and accurate reconstruction methods to aid future analyses of baryonic feedback using the SZ effect. The first approach employs a Gaussian process emulator to model the SZ quantities via a transfer function, while the second utilizes hybrid effective field theory (HEFT) to reproduce these quantities within the simulation. Our analysis involves comparing both methods to the true MillenniumTNG optical depth and Compton-y fields using several metrics, including the cross-correlation coefficient, power spectrum, and power spectrum error. Additionally, we assess how well the reconstructed fields correlate with dark matter haloes across various mass thresholds. The results indicate that the transfer function method yields more accurate reconstructions for fields with initially high correlations (r ≈ 1), such as between the optical depth and dark matter fields. Conversely, the HEFT-based approach proves more effective in enhancing correlations for fields with weaker initial correlations (r ∼ 0.5), such as between the Compton-y and dark matter fields. Lastly, we discuss extensions of our methods to improve the reconstruction performance at the field level.

Liu, R. Henry [University of California, Berkeley,

Cross-functional transferability in foundation machine learning interatomic potentials

The rapid development of foundation potentials (FPs) in machine learning interatomic potentials demonstrates the possibility for generalizable learning of the universal potential energy surface. The accuracy of FPs can be further improved by bridging the model from lower-fidelity datasets to high-fidelity ones. In this work, we analyze the challenge of this transfer learning (TL) problem within the CHGNet framework. We show that significant energy scale shifts and poor correlations between GGA and r 2 SCAN hinder cross-functional transferability. By benchmarking different TL approaches on the MP-r 2 SCAN dataset, we demonstrate the importance of elemental energy referencing in the TL of FPs. By comparing the scaling law with and without the pre-training on a low-fidelity dataset, we show that significant data efficiency can still be achieved through TL, even with a target dataset of sub-million structures. We highlight the importance of proper TL and multi-fidelity learning in creating next-generation FPs on high-fidelity data.

Huang, Xu [University of California, Berkeley, CA

Beam Signal Recovery Using Wiener Deconvolution

This project explores the use of Wiener deconvolution to recover an original signal that has been distorted by a known transfer function and by noise. A simulated Gaussian pulse was used as the test signal, and a transfer function was applied in the frequency domain to model system distortion. Controlled noise was then introduced to approximate real-world signal degradation. A Wiener filter was implemented to reverse the effects of the transfer function while minimizing the influence of noise. The recovered signal was compared to the original pulse to evaluate the effectiveness of the filter. Results demonstrate that Wiener deconvolution offers a stable and effective approach to signal recovery, balancing complete transfer function inversion and noise suppression.

Campbell, Savanna [El Camino Coll.]

Wiener Filter Deconvolution for Analog Signals

This project explores the use of Wiener deconvolution to recover an original signal that has been distorted by a known transfer function and by noise. A simulated Gaussian pulse was used as the test signal, and a transfer function was applied in the frequency domain to model the system distortion. Controlled noise was then introduced to approximate real-world signal degradation. A Wiener filter was implemented to reverse the effects of the transfer function while minimizing the influence of noise. The recovered signal was compared with the original pulse to evaluate the effectiveness of the filter. The results demonstrate that Wiener deconvolution offers a stable and effective approach to signal recovery, balancing complete transfer function inversion and noise suppression.

Campbell, Savanna [Fermilab]

Second-order wave excitation forces in WEC-Sim/MOST: Implementation, experimental validation, and code-to-code comparison

Accurate prediction of second-order hydrodynamic loads is essential for floating bodies, including floating offshore wind turbines, wave energy converters, and hybrid wind–wave platforms. These nonlinear effects, arising from both sum- and difference-frequency forcing, are critical for capturing key response characteristics but remain challenging to model efficiently. In this work, we extend the open-source Wave Energy Converter Simulator / MATLAB for Offshore Simulation Tool by implementing second-order wave excitation forces, supporting both the full Quadratic Transfer Function formulation and the Newman approximation. The full Quadratic Transfer Function method is used for all code-to-code comparisons and experimental validation, while the Newman approximation is provided as a computationally lighter alternative. To benchmark the new capability, we perform a code-to-code comparison with OpenFAST and OrcaFlex. We then validate the enhanced model using wave-tank measurements of a 1:96 scale DeepCwind semi-submersible, showing that second-order effects are required to reproduce platform motions. The implementation employs a computationally efficient pre-computation strategy for second-order wave excitation forces, reducing simulation cost while maintaining engineering accuracy. Overall, this work advances the tool as an open-source and versatile tool for modelling floating offshore renewable-energy systems requiring second-order hydrodynamic fidelity.

17 WIND ENERGY

Quantifying System Strength From Grid-Forming Resources Using Frequency Scan Approach: Preprint

Current industry practices for quantifying the system strength contribution from grid-forming (GFM) resources to ensure stability of power systems dominated by inverter-based resources (IBRs) are primarily based on iterative electromagnetic transient (EMT) time-domain simulation studies. While feasible, these approaches are resource-intensive, lack scalability and intuition, and might not evaluate the system strength contribution over the entire frequency range of interest. This paper introduces a novel, frequency-domain approach to quantify system strength support provided by a GFM resource using frequency scans. The proposed method uses transfer functions from the grid voltage magnitude (V) and phase (?), respectively, to the reactive (Q) and active power (P) output of a GFM resource for quantifying its contribution to system strength. These transfer functions provide a direct measure of the ability of a GFM resource to behave as a stiff voltage source behind a reactance over a specified frequency range, enabling robust quantification of its system strength contribution. The key innovation of this work is the development of a frequency domain system strength metric called the dynamic short-circuit ratio (dSCR) that is suitable for IBR-dominated power systems and is directly related with the familiar short circuit ratio (SCR) metric. The new metric, dSCR, enables the assessment of system strength contributions from both synchronous machines and converter-based GFM resources using a unified benchmark, which is not possible with the traditional SCR metric. The paper also demonstrates how impedance scans could identify if an unstable condition observed during weak grid conditions is a result of the lack active or reactive power support or both. By leveraging the proposed frequency-domain dSCR metric for quantifying system strength contribution from GFM IBRs, the paper demonstrates targeted mitigation strategies for weak grid instabilities without resorting to repeated, time-consuming time-domain simulations. The result is a scalable and efficient approach to remediate stability challenges in power systems with high shares of IBRs and accelerating the integration of GFM technologies for system strength support in power systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Investigating Oscillations in Bulb Turbine Plant During Islanded black start Operation

This paper investigates the frequency oscillatory behavior displayed by the bulb turbine-based run-of-river (ROR) hydropower system under islanded operation. These oscillations prevent higher loading of these generators (under islanded conditions) and hence reduce the black start capability of these generators. To investigate the problem, first, a transfer function model of the bulb-turbine system, sensitive to the effects of head variation, blade angle, and other non-linearities pertaining to turbine characteristics is derived. Next, by analyzing this transfer function model and through simulations, it is determined that system inertia along with other parameters could be responsible for these oscillations. Also, through simulations it is shown that the same ROR system’s behavior is different under islanded mode compared to grid-connected mode.

13 HYDRO ENERGY

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko

Super-resolution imaging reveals resistance to mass transfer in functionalized stationary phases

Chemical separations are costly in terms of energy, time, and money. Separation methods are optimized with inefficient trial-and-error approaches that lack insight into the molecular dynamics that lead to the success or failure of a separation and, hence, ways to improve the process. We perform super-resolution imaging of fluorescent analytes in five different commercial liquid chromatography materials. Unexpectedly, we observe that chemical functionalization can block more than 50% of the material’s porous interior, rendering it inaccessible to small-molecule analytes. Only in situ imaging unveils the inaccessibility when compared to the industry-accepted ex situ characterization methods. Selectively removing some of the functionalization with solvent restores pore access without substantially altering the single-molecule kinetics that underlie the separation and agree with bulk chromatography measurements. Our molecular results determine that commercial “fully porous” stationary phases are over-functionalized and provide an alternative avenue to characterize and direct separation material design from the bottom-up.

Science & Technology - Other Topics

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval

Characterization of Impedance and Stability for Doubly-Fed Induction Generator Based on Voltage-Modulated Direct Power Control

Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. Here, this article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the αβ -frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

42 ENGINEERING

Tabletop Testing for EV Charging Ecosystem PKI (Project T34PKI Final Report)

To test the communications and cybersecurity functionality, Electric Vehicle and charging station vendors have had to ship their products to in-person testing events. This is cumbersome, expensive, inefficient, and an impediment to rapid time-to-deployment. In this project Sandia used COTS hardware and Open-Source Software to develop and demonstrate a more agile, productive approach: testing low-voltage controllers independently from high-voltage power delivery sub-systems. This approach allows communications controllers to be transported easily (e.g. shipped at low cost, checked as airline baggage); set up on a table-top (“bench testing”); and use ordinary 120 VAC outlets to conduct agile testing. Table-top platforms become end nodes that can connect to laboratory and cloud-based servers to test communications and cybersecurity, specifically Public Key Infrastructure (PKI) functionality and interoperability, separately from EV battery charging (power/energy transfer) functionality.

33 ADVANCED PROPULSION SYSTEMS

Validation and moisture content sensitivity analysis of cross-laminated timber wall assemblies in EnergyPlus

Cross-laminated timber buildings are becoming more common in North America, with many numerical studies showing potential energy savings. However, no studies have validated any EnergyPlus heat transfer algorithms or quantified their accuracy in simulating CLT in building envelopes. This study empirically validates the heat flux predictions for each of EnergyPlus's heat transfer algorithms (Conduction Transfer Functions (CTF), Effective Moisture Penetration Depth (EMPD), Conduction Finite Difference (CondFD), and Heat and Moisture Transfer (HAMT)) for two different CLT ply thicknesses with both summer and winter boundary conditions measured in controlled lab experiments. It also evaluates the model sensitivity of heat flux and heating and cooling loads to moisture content. The 1D validation shows that the HAMT model is the most accurate among all algorithms. All EnergyPlus's heat flux predictions are accurate independent of CLT plate thickness for summer conditions. However, the three constant property algorithms (CTF, EMPD, and CondFD) underpredict heat flux throughout the whole day during winter conditions. The 1D sensitivity analysis indicates that elevated moisture content can increase peak heat fluxes through the material by up to 20 %. Finally, the whole building model sensitivity analysis shows increased heating load and slight cooling load variation due to increased moisture content when using constant property models. The analysis shows significantly lower peak thermal demand (7 % lower heating and 6 % lower cooling) and monthly thermal load (8 % less cooling and 6 % less heating) predictions when using HAMT vs a constant property model.

42 ENGINEERING