Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Distributed Control of Inverter-Interfaced Microgrids Based on Consensus Algorithm with Improved Transient Performance

Conventional control solutions of the inverter-interfaced microgrids are usually designed based on models with fully decoupled subsystems. The negligence of the strong coupling due to power lines impedance leads to large transient line currents, which might trigger false protection. Besides, the droop-based control methods unnecessarily introduce system frequency and voltage deviations. To overcome these issues, a novel distributed control scheme is proposed for the inverter-interfaced microgrids in this study. The objective of the primary control is to regulate the bus voltages and frequency while suppressing the transient line currents. The objective of secondary control is to maintain fair load sharing. Both primary control and secondary control are distributed and subsystems or control agents only require measurements from local and neighboring subsystems. The detailed control problem formulation, control design and stability analysis are presented in the paper. Finally, the effectiveness of the proposed control solution is evaluated through extensive simulations based on both simplified and detailed models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Voltage Modeling and Testing of Transformer, Line Interface Devices, and Bulk System Components Under Electromagnetic Pulse, Geomagnetic Disturbance, and other Abnormal Transients

This project aims at quantitatively analyzing possible knowledge gaps related to the risk of Electromagnetic Pulse (EMP) impact on high-voltage, power transformers (transmission-class), that represent the most critical power grid assets. In relation to the electric infrastructure, some past studies indicate that the grid is overall fairly robust and resilient against most EMP threats. This assessment stems, in part, from estimates of the peak voltage that can be induced on a transmission power line for a nominal EMP fast-transient, compared with the typically very high basic insulation level that is featured by the high-voltage infrastructure. The project provides additional insight toward a more comprehensive risk evaluation of the grid EMP and Geomagnetic Disturbances (GMD) vulnerabilities. This work is aligned with the U.S. Dept. of Energy current research thrust in support of the development of a highly secure and resilient power infrastructure. Project milestones have been devised to address the fundamental technical issues in support of protection of large power transformer against EMP threats. More specifically, this project included parallel research tasks focused on the following topics: analysis of EMP-induced, fast-transient, current and voltages on a variety of power line configurations and EMP impact scenarios, detailed characterization of EMP damage potential due to the voltage surge, from the impact on the power line, to the transformer windings, GMD and EMP slow transients and impact from harmonics generation and reactive power flow on a complex grid layout, and identification of risk mitigation paths, with emphasis on GIC damage prevention for large power transformers, and on impact protection options from a grid stability perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

$\mathrm{T}$ransient $\mathrm{CHI}$ System Design Studies for $\mathrm{P}$ EGASUS -$\mathrm{III}$

We report transient coaxial helicity injection (transient CHI), first developed on the Helicity Injected Torus-II (HIT-II) and later on the National Spherical Torus Experiment (NSTX) for implementing solenoid-free plasma current startup capability in a spherical tokamak (ST), is now planned to be tested on the Pegasus-III ST using a novel double-biased configuration. Such a configuration is likely needed for transient CHI deployment in a reactor. The transient CHI system optimization will be studied on Pegasus-III to enable startup toroidal persisting currents at the limits permitted by the external poloidal field coils. A transient CHI discharge is generated by driving injector current along magnetic field lines that connect the inner and outer divertor plates on one end of the ST. Simulations using the Tokamak Simulation Code are used to assess the transient CHI toroidal current generation potential and electrode gap location on the Pegasus-III. While past transient CHI systems have used high-voltage, oil-filled capacitors for driving the injector current, for improved safety, Pegasus-III will use a high-current capacitor bank based on low-voltage electrolytic capacitors. The designed and fabricated system is capable of over 32 kA. The modular design features permit the system to be upgraded to higher currents, as needed, to meet the future needs of the Pegasus-III facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A universal procedure for evaluation and application of surge-protective devices

The source, nature, and frequency of occurrence of transients must be identified and a representative standard test wave chosen for proof testing. The performance of candidate suppressor devices then can be evaluated against the withstand goals set for the equipment. The various suppressors divide into two classes of generic behavior. The key to a universal procedure for evaluating both classes lies in representing transients as quasi-current sources of defined current impulse duration. The available surge current is established by the Thevenin equivalent transient voltage and source impedance. A load line drawn on the V-I characteristic graph of the suppressor quickly determines the clamping voltage and peak current. These values then can be compared to the requirement. The deposited energy and average power dissipation for multiple transients also can be calculated. The method is illustrated with a design example for motor vehicle alternator load dump suppression.

Source record↗

Energetic ions as remote probes of X type neutral lines in the geomagnetic tail

The study presents a summary of particle orbit signatures of a neutral line in the geomagnetic tail current sheet (CS) as a function of spatial position along the CS boundary layer, as well as within the CS. Six types of CS particle orbits are reviewed: transient B sub z, transient X line, quasi-trapped, trapped, noncrossing X line, and limiting (singular) cases. It is found that for single particle dynamics in a current sheet with neutral line, the phase space ridge is predicted to be found throughout the current sheet if it is not destroyed by collective behavior. An initially tailward flowing distribution causes asymmetries in distributions earthward vs tailward of the neutral line. It is suggested that the chaotic pitch angle scattering may be a dominant mechanism to produce nightside proton isotropy in the auroral zones.

Speiser, T. W.↗

Development of a Converter-Based Transmission Line Emulator with Three-Phase Short-Circuit Fault Emulation Capability

A transmission line emulator has been developed to flexibly represent interconnected ac lines under normal operating conditions in a voltage source converter (VSC)-based power system emulation platform. As the most serious short-circuit fault condition, the three-phase short-circuit fault emulation is essential for power system studies. Here, this paper proposes a model to realize a three-phase short-circuit fault emulation at different locations along a single transmission line or one of several parallel-connected transmission lines. At the same time, a combination method is proposed to eliminate the undesired transients caused by the current reference step changes while switching between the fault state and the normal state. Experiment results verify the developed transmission line three-phase short-circuit fault emulation capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Properties of the electrostatically driven helical plasma state

A novel plasma state has been found [Akçay et al ., Phys. Plasmas 24 , 052503 (2017)] in the presence of a uniform applied axial magnetic field in periodic cylindrical geometry. This state is driven by external electrostatic fields provided by helical electrodes with a ($m=1,n=1$) (helical) symmetry where $m$ and $n$ represent the poloidal and axial harmonics. The resulting plasma is a function of the cylinder radius $r < r_w$ and helical angle $u=mθ-nζ$, where θ is the poloidal angle, and $ζ=z/R$ is the normalized axial coordinate in the context of a periodic cylinder. In this reference, the strongly driven form of the state was found to have a strong axial mean current density, with a mean-field line safety factor $q_0(r)$ just above the pitch of the electrodes m/n=1 in the interior, where the plasma is nearly force-free. However, at the edge the current density has a component perpendicular to the magnetic field B. This perpendicular current density drives nearly Alfvénic helical plasma flows, a notable feature of these states. This state is being studied for its possible application in $DC$ electrical transformers. We present results on several issues of importance for these applications: the transient leading to the steady state; the twist and writhe of the field lines and their relation with the current density; the properties of the current density streamlines and length of the current density lines connected to the electrodes; the sensitivity to changes in the velocity boundary conditions; the effect of varying the radial resistivity profile; and the effects of a concentrated electrode potential

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Hybrid simulations of a tangential discontinuity-driven foreshock bubble formation in comparison with a hot flow anomaly formation

Hot flow anomalies (HFAs) and foreshock bubbles (FBs) are significant foreshock transients that can accelerate particles and disturb the magnetosphere-ionosphere system. Yet, their early formation mechanisms are still not fully understood. To investigate the formation of tangential discontinuity (TD)-driven FBs and HFAs, we use 2-D local hybrid simulations where a reflected or an injected warm foreshock ion beam can interact with a TD whose half-thickness is comparable to the ion inertial scale. We show that the foreshock ions perform a partial gyration within, or across, the TD. Bulk motion differences between partially-gyrating foreshock ions and fluid-electrons lead to the generation of currents. As the trigger, these foreshock-driven currents change the magnetic field topology around the TD and force the frozen-in solar wind plasma to redistribute along with the field lines, shaping the foreshock transient. This confirms a recently proposed kinetic formation model. The extent of the magnetic field direction change across the TD within the foreshock ion gyromotion determines the current profile and thus the type of foreshock transient that forms. For a thin TD, the foreshock ions generate a current that is much stronger on the upstream side than the downstream side, forming an FB with one upstream compressional boundary. For the same foreshock ion gyroradius and magnetic shear, a thick TD yields comparable foreshock-driven currents on the upstream and downstream sides, forming an HFA with two compressional boundaries. Our study suggests that the TD thickness is one of the factors that determine the formation of FBs and HFAs

Andrew Vu↗

Equatorial spacecraft-plasma interaction phenomenon observed with DE 2

Data from the retarding potential analyzer and ion drift meter on Dynamics Explorer 2 indicate that an unusual spacecraft-plasma interaction phenomemon occurs at times when the spacecraft velocity vector becomes nearly aligned with the local geomagnetic field lines. The primary signature of the interaction is a transient increase in the ion collection currents obtained with these instruments, up to approximately 15% in magnitude and typically a few tens of seconds duration. This signature is indicative of an increase in the net ion and electron currents to the satellite and is accompanied by a small positive increase in the spacecraft potential relative to the plasma. We present here a case study covering six of the strongest such events observed with DE 2 and discuss a possible physical mechanism. We suggest in particular that what might be called a collisional electron 'snowplow' effect may be occurring, and we derive a simple numerical model based on this scenario. Least squares fitting is employed to test the model and to derive new estimates of the ambient ion concentration at times when the measurements are being perturbed by the interaction.

Cragin, B. L.↗

Equatorial Spacecraft-Plasma Interaction Phenomenon Observed With DE 2

Data from the retarding potential analyzer and ion drift meter on Dynamics Explorer 2 indicate that an unusual spacecraft-plasma interaction phenomenon occurs at times when the spacecraft velocity vector becomes nearly aligned with the local geomagnetic field lines. The primary signature of the interaction is a transient increase in the ion collection currents obtained with these instruments, up to approximately 15% in magnitude and typically a few tens of seconds duration. This signature is indicative of an increase in the net ion and electron currents to the satellite and is accompanied by a small positive increase in the spacecraft potential relative to the plasma. We present here a case study covering six of the strongest such events observed with DE 2 and discuss a possible physical mechanism. We suggest in particular that what might be called a collisional electron snowplow effect may be occurring, and we derive a simple numerical model based on this scenario. Least squares fitting is employed to test the model and to derive new estimates of the ambient ion concentration at times when the measurements are being perturbed by the interaction.

Cragin, B. L.↗

Three-phase short-circuit fault implementation in converter based transmission line emulator

A hardware test-bed (HTB) has been developed to realize power system emulation by mimicking the system components with universal three-phase voltage source converters (VSCs). The VSC-based transmission line emulator has also been successfully developed to flexibly represent interconnected ac lines under normal operating conditions. As the most serious short-circuit fault condition, the three-phase short-circuit fault emulation is essential for power system studies. This paper proposes a model to realize the three-phase short-circuit fault emulation within the emulated transmission line. At the same time, a combination method is proposed to eliminate the undesired transients caused by the current reference step changes while switching between the fault state and normal state.

Zhang, Shuoting↗

Analysis of Liquids Using the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER)

We developed a sensor called the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER) probe, which uses an atmospheric pressure glow discharge below the surface of liquids to excite species in the liquid. Through emission spectroscopy of molten salts, liquid metals, and heavy water, we demonstrated the SPIDER probe’s high resolution, accuracy, and versatility. We successfully identified trace concentrations of transition and rare-earth metals in molten salts and detected the isotopic shift of the H β → D β emission line. Our analysis revealed unconventional spectral alkali line shapes, indicating two competing excitation modes: film explosion and droplet vaporization. The film explosion mode, characterized by dense plasma, exhibited self-reversal and broadband continuum emission, while the droplet vaporization mode, associated with diffusive plasma, produced narrow-line emissions. Furthermore, by analyzing circuit transients alongside individual plasma events, we observed that film explosions generate higher currents, likely due to a shorter plasma length as the current preferentially flows through the thin liquid layer. Altogether, our results highlight the SPIDER probe’s efficacy and flexibility, making it well-suited for online material quantification of liquids in extreme environments.

AES↗

LabHEART: an interactive computer model of rabbit ventricular myocyte ion channels and Ca transport

An interactive computer program, LabHEART, was developed to simulate the action potential (AP), ionic currents, and Ca handling mechanisms in a rabbit ventricular myocyte. User-oriented, its design allows switching between voltage and current clamp and easy on-line manipulation of key parameters to change the original formulation. The model reproduces normal rabbit ventricular myocyte currents, Ca transients, and APs. We also changed parameters to simulate data from heart failure (HF) myocytes, including reduced transient outward (I(to)) and inward rectifying K currents (I(K1)), enhanced Na/Ca exchange expression, and reduced sarcoplasmic reticulum Ca-ATPase function, but unaltered Ca current density. These changes caused reduced Ca transient amplitude and increased AP duration (especially at lower frequency) as observed experimentally. The model shows that the increased Na/Ca exchange current (I(NaCa)) in HF lowers the intracellular [Ca] threshold for a triggered AP from 800 to 540 nM. Similarly, the decrease in I(K1) reduces the threshold to 600 nM. Changes in I(to) have no effect. Combining enhanced Na/Ca exchange with reduced I(K1) (as in HF) lowers the threshold to trigger an AP to 380 nM. These changes reproduce experimental results in HF, where the contributions of different factors are not readily distinguishable. We conclude that the triggered APs that contribute to nonreentrant ventricular tachycardia in HF are due approximately equally (and nearly additively) to alterations in I(NaCa) and I(K1). A free copy of this software can be obtained at http://www.meddean.luc.edu/lumen/DeptWebs/physio/bers.html.

NASA Discipline Cardiopulmonary↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The ac power line protection for an IEEE 587 Class B environment

The 587B series of protectors are unique, low clamping voltage transient suppressors to protect ac-powered equipment from the 6000V peak open-circuit voltage and 3000A short circuit current as defined in IEEE standard 587 for Category B transients. The devices, which incorporate multiple-stage solid-state protector components, were specifically designed to operate under multiple exposures to maximum threat levels in this severe environment. The output voltage peaks are limited to 350V under maximum threat conditions for a 120V ac power line, thus providing adequate protection to vulnerable electronic equipment. The principle of operation and test performance data is discussed.

Roehr, W. D.↗