Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Transient performance evaluation of an integrated heat pipe-thermal storage system

Transient performance tests of an integrated heat pipe-thermal storage system have been conducted. This system was developed as a part of an Organic Rankine Cycle-Solar Dynamic Power System receiver for future power systems. The integrated system consists of potassium heat pipe elements that incorporate thermal energy storage canisters within the vapor space and an organic fluid (toluene) heater tube used as the condenser region of the heat pipe. The transient performance tests determined the operating characteristics and power input limits of the integrated heat pipe-thermal storage unit under conditions corresponding to re-acquisition of the sun during emergence from eclipse conditions and to the initial start-up of the solar dynamic power system. The tests demonstrated that the heat pipe-thermal storage element is not limited under conditions corresponding to emergence from eclipse during normal orbital operations and the heat pipe will successfully start-up from the frozen condition with full input power at the onset. Details of the test procedures and results of the tests are presented in this paper.

Keddy, E.↗

Performance characteristics of a thermal energy storage module - A transient PCM/forced convection conjugate analysis

The performance of a thermal energy storage module is simulated numerically. The change of phase of the phase-change material (PCM) and the transient forced convective heat transfer for the transfer fluid with low Prandtl numbers are solved simultaneously as a conjugate problem. A parametric study and a system optimization are conducted. The numerical results show that module geometry is crucial to the design of a space-based thermal energy storage system.

Cao, Y.↗

Transient Thermal Model and Analysis of the Lunar Surface and Regolith for Cryogenic Fluid Storage

A transient thermal model of the lunar surface and regolith was developed along with analytical techniques which will be used to evaluate the storage of cryogenic fluids at equatorial and polar landing sites. The model can provide lunar surface and subsurface temperatures as a function of latitude and time throughout the lunar cycle and season. It also accounts for the presence of or lack of the undisturbed fluff layer on the lunar surface. The model was validated with Apollo 15 and Clementine data and shows good agreement with other analytical models.

Christie, Robert J.↗

Transient analysis of a thermal storage unit involving a phase change material

The transient response of a single cell of a typical phase change material type thermal capacitor has been modeled using numerical conductive heat transfer techniques. The cell consists of a base plate, an insulated top, and two vertical walls (fins) forming a two-dimensional cavity filled with a phase change material. Both explicit and implicit numerical formulations are outlined. A mixed explicit-implicit scheme which treats the fin implicity while treating the phase change material explicitly is discussed. A band algorithmic scheme is used to reduce computer storage requirements for the implicit approach while retaining a relatively fine grid. All formulations are presented in dimensionless form thereby enabling application to geometrically similar problems. Typical parametric results are graphically presented for the case of melting with constant heat input to the base of the cell.

Griggs, E. I.↗

A PCM/forced convection conjugate transient analysis of energy storage systems with annular and countercurrent flows

Latent heat energy storage systems with both annular and countercurrent flows are modeled numerically. The change of phase of the phase-change material (PCM) and the transient forced convective heat transfer for the transfer fluid are solved simultaneously as a conjugate problem. A parametric study and a system optimization are conducted. It is found that the energy storage system with the countercurrent flow is an efficient way to absorb heat energy in a short period for pulsed power load space applications.

Cao, Y.↗

Thermal buffering of receivers for parabolic dish solar thermal power plants

A parabolic dish solar thermal power plant comprises a field of parabolic dish power modules where each module is composed of a two-axis tracking parabolic dish concentrator which reflects sunlight (insolation) into the aperture of a cavity receiver at the focal point of the dish. The heat generated by the solar flux entering the receiver is removed by a heat transfer fluid. In the dish power module, this heat is used to drive a small heat engine/generator assembly which is directly connected to the cavity receiver at the focal point. A computer analysis is performed to assess the thermal buffering characteristics of receivers containing sensible and latent heat thermal energy storage. Parametric variations of the thermal inertia of the integrated receiver-buffer storage systems coupled with different fluid flow rate control strategies are carried out to delineate the effect of buffer storage, the transient response of the receiver-storage systems and corresponding fluid outlet temperature. It is concluded that addition of phase change buffer storage will substantially improve system operational characteristics during periods of rapidly fluctuating insolation due to cloud passage.

Manvi, R.↗

Impedance of silver oxide-zinc cells

Over 100 sealed AgO-Zn cells were subjected to prolonged periods of storage over a range of temperatures and storage modes including open circuit, trickle charge, and float charge. Impedances of these cells were monitored throughout, and at the end of the storage period their transient voltage characteristics were observed at the onset of discharge. Results revealed that the impedances of these cells tended to increase with storage time; the magnitude of the impedance rise was dependent primarily on temperature and to a lesser degree on storage mode. Typical values for 50 A-hr cells were usually less than 100 mohm immediately after activation and from 1 to 30 ohm after 6-10 months of storage. Transient voltages of these cells droped sharply during the first msec of discharge and then rose to a stablized value during the following few seconds. The magnitude of the initial drop and the stabilized voltage values were found to be related to impedance but not in a linear manner. The magnitude and duration of the low transient voltages may be unacceptable in some applications of these cells. The impedance variations are attributed to changes occurring at the positive electrode.

Frank, H. A.↗

Tropopause Laminar Cirrus and Its Role in the Lower Stratosphere Total Water Budget

Laminar cirrus are thin, extensive, isolated layers of ice clouds frequently observed in the tropical tropopause layer. Widespread laminar cirrus significantly affects tropical tropopause layer total water and thermal budget. In this study, we extract laminar cirrus from the Cloud‐Aerosol Lidar with Orthogonal Polarization Level 1 attenuated total backscatter images for January 2009, in order to characterize statistical properties of laminar cirrus cloud length, base, thickness, optical depth, and layer partial ice water path. These characteristics are used to develop an algorithm identifying laminar cirrus automatically from the Cloud‐Aerosol Lidar with Orthogonal Polarization Level 2 layer product for 2008–2017. The nearly 10‐year records reveal that tropopause laminar cirrus occurrence (30–40% of total cirrus) is strongly anticorrelated with the tropopause temperatures in that colder tropopause in frequent (super)saturation during boreal winter favors in situ formation of clouds. Interannually, anomalously warmer troposphere temperature (ΔT), easterly shear of the quasi‐biennial oscillation, and stronger upwelling branch of the Brewer‐Dobson circulation enhance laminar cirrus formation via cooling of the tropopause. The tropopause laminar cirrus carries ~0.05 mg/m(exp 3) (~0.5 ppmv) of ice water content during boreal winter and <0.01 mg/m(exp 3) during summer, which is anticorrelated with the seasonal variations of water vapor (H2O) observed by the Microwave Lime Sounder, indicating a temperature‐regulated partition between vapor and ice. Interannually, in cirrus‐rich region 1 ppmv decrease in H2O corresponds to 0.2–0.3 ppmv increase in ice water content. Frequently situated in (super)saturated air, tropopause laminar cirrus are likely to survive multiple lifecycles of the sublimation‐deposition processes, and may contribute up to 10% to the total water budget in the lower stratosphere. Satellites constantly observe thin, isolated, extensive layer of cirrus around the tropopause. The so‐called “laminar” cirrus occurrence and their ice amount are strongly regulated by temperature, such that colder temperatures favor more frequent (super)saturation, which results in more frequent laminar cirrus with more ice amount and therefore less water vapor. In this study we analyze laminar cirrus and water vapor from the Cloud‐Aerosol Lidar with Orthogonal Polarization and Microwave Lime Sounder observations, and hypothesize that laminar cirrus could act as an important transient water storage and contribute to the total water budget in the lower stratosphere.

Tao Wang↗

Transient Modeling of Large Scale Integrated Refrigeration and Storage Systems

Recently, next generation techniques and designs were demonstrated using Integrated Refrigeration and Storage (IRAS) for large scale storage of liquid hydrogen at NASA Kennedy Space Center (KSC) in Florida. Zero boil-off, densification, and in-situ liquefaction of hydrogen were achieved at various fill levels inside a custom-built 125,000 liter, horizontal-cylindrical IRAS tank, validating the applicability of the concept for large scale cryo-fluid storage architectures. This paper will discuss a number of transient physics models developed to predict the bulk behavior of large IRAS systems, and the comparison of those models to data gathered during the KSC test campaign. In an attempt to extent their usefulness to future IRAS designs, these models were agnostic with respect to stored fluid, tank size and geometry. Behavior during densification testing was examined at three fill levels, and ultimately the depressurization and bulk temperature trends of the KSC tests were predicted with good accuracy.

Swanger, Adam M.↗

Transient Modeling of Large Scale Integrated Refrigeration and Storage Systems

Recently, next generation techniques and designs were demonstrated using Integrated Refrigeration and Storage (IRAS) for large scale storage of liquid hydrogen at NASA Kennedy Space Center (KSC) in Florida. Zero boil-off, densification, and in-situ liquefaction of hydrogen were achieved at various fill levels inside a custom-built 125,000 liter, horizontal-cylindrical IRAS tank, validating the applicability of the concept for large scale cryo-fluid storage architectures. This paper will discuss a number of transient physics models developed to predict the bulk behavior of large IRAS systems, and the comparison of those models to data gathered during the KSC test campaign. In an attempt to extent their usefulness to future IRAS designs, these models were agnostic with respect to stored fluid, tank size and geometry. Behavior during densification testing was examined at three fill levels, and ultimately the depressurization and bulk temperature trends of the KSC tests were predicted with good accuracy.

Swanger, Adam M.↗

Space Vehicle Power System Comprised of Battery/Capacitor Combinations

Recent improvements in energy densities of batteries open the possibility of using electric rather that hydraulic actuators in space vehicle systems. However, the systems usually require short-duration, high-power pulses. This power profile requires the battery system to be sized to meet the power requirements rather than stored energy requirements, often resulting in a large and inefficient energy storage system. Similar transient power applications have used a combination of two or more disparate energy storage technologies. For instance, placing a capacitor and a battery side-by-side combines the high energy density of a battery with the high power performance of a capacitor and thus can create a lighter and more compact system. A parametric study was performed to identify favorable scenarios for using capacitors. System designs were then carried out using equivalent circuit models developed for five commercial electrochemical capacitor products. Capacitors were sized to satisfy peak power levels and consequently "leveled" the power requirement of the battery, which can then be sized to meet system energy requirements. Simulation results clearly differentiate the performance offered by available capacitor products for the space vehicle applications.

Camarotte, C.↗

Supraglacial River Forcing of Subglacial Water Storage and Diurnal Ice Sheet Motion

Surface melting impacts ice sheet sliding by supplying water to the bed, but subglacial processes driving ice accelerations are complex. We examine linkages between surface runoff, transient subglacial water storage, and short-term ice motion from 168 consecutive hourly measurements of meltwater discharge (moulin input) and GPS-derived ice surface motion for Rio Behar, a ∼60 sq. km moulin-terminating supraglacial river catchment on the southwest Greenland Ice Sheet. Short-term accelerations in ice speed correlate strongly with lag-corrected measures of supraglacial river discharge (r = 0.9, τ = 0.7, p < 0.01). Though our 7 days record cannot address seasonal-scale forcing, diurnal ice accelerations align with normalized differenced supraglacial and proglacial discharge, a proxy for subglacial storage change, better than GPS-derived ice surface uplift. These observations counter theoretical steady state basal sliding laws and suggest that moulin and proglacially induced fluctuations in subglacial water storage, rather than absolute subglacial water storage, drive short-term ice accelerations.

Glacial↗

Ice Growth Model for Polar Water Capture Systems

In-situ resource utilization (ISRU) is essential to NASA’s goal of sustainable and cost-effective missions to the Moon and beyond. Water has become a particular source of interest since its discovery in the permanently shadowed regions (PSRs) of the Moon. This water exists as ice bound within the regolith, so one mode of capture is heating to sublimation temperatures and capturing at very low pressure. It then can be stored in ice form and transported out of the PSR and to a sunlit ridge, where processes such as electrolysis can be performed[2]. An understanding of frost growth dynamics under rarefied conditions is necessary for successful water capture and storage due to transient thermal properties of frost. A Diffusion-Limited Aggregation (DLA) approach was taken to analytically model bulk thermal conductivity changes of the growing frost layer under varying wall temperatures and frost layer porosities. The model utilizes well-known correlations for effective thermal conductivity and records the values as the frost layer thickness increases. This thermal conductivity can be applied to a known temperature change and be used to evaluate heat flux through the combined frost layer and tank wall for either a flat plate or cylindrical geometry. An experiment is described that will evaluate this model using one-dimensional frost growth on a horizontal, flat plate under low-pressure. The ice growth will be measured using a millimeter-scale photogrammetry camera system and a load cell measured transient mass growth.

In situ Resource Utilization↗