Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient storage model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Transient Thermal Model and Analysis of the Lunar Surface and Regolith for Cryogenic Fluid Storage

A transient thermal model of the lunar surface and regolith was developed along with analytical techniques which will be used to evaluate the storage of cryogenic fluids at equatorial and polar landing sites. The model can provide lunar surface and subsurface temperatures as a function of latitude and time throughout the lunar cycle and season. It also accounts for the presence of or lack of the undisturbed fluff layer on the lunar surface. The model was validated with Apollo 15 and Clementine data and shows good agreement with other analytical models.

Christie, Robert J.↗

Transient Modeling of Large Scale Integrated Refrigeration and Storage Systems

Recently, next generation techniques and designs were demonstrated using Integrated Refrigeration and Storage (IRAS) for large scale storage of liquid hydrogen at NASA Kennedy Space Center (KSC) in Florida. Zero boil-off, densification, and in-situ liquefaction of hydrogen were achieved at various fill levels inside a custom-built 125,000 liter, horizontal-cylindrical IRAS tank, validating the applicability of the concept for large scale cryo-fluid storage architectures. This paper will discuss a number of transient physics models developed to predict the bulk behavior of large IRAS systems, and the comparison of those models to data gathered during the KSC test campaign. In an attempt to extent their usefulness to future IRAS designs, these models were agnostic with respect to stored fluid, tank size and geometry. Behavior during densification testing was examined at three fill levels, and ultimately the depressurization and bulk temperature trends of the KSC tests were predicted with good accuracy.

Swanger, Adam M.↗

Transient Modeling of Large Scale Integrated Refrigeration and Storage Systems

Recently, next generation techniques and designs were demonstrated using Integrated Refrigeration and Storage (IRAS) for large scale storage of liquid hydrogen at NASA Kennedy Space Center (KSC) in Florida. Zero boil-off, densification, and in-situ liquefaction of hydrogen were achieved at various fill levels inside a custom-built 125,000 liter, horizontal-cylindrical IRAS tank, validating the applicability of the concept for large scale cryo-fluid storage architectures. This paper will discuss a number of transient physics models developed to predict the bulk behavior of large IRAS systems, and the comparison of those models to data gathered during the KSC test campaign. In an attempt to extent their usefulness to future IRAS designs, these models were agnostic with respect to stored fluid, tank size and geometry. Behavior during densification testing was examined at three fill levels, and ultimately the depressurization and bulk temperature trends of the KSC tests were predicted with good accuracy.

Swanger, Adam M.↗

Modeling Demographic-Driven Vegetation Dynamics and Ecosystem Biogeochemical Cycling in NASA GISS’s Earth System Model (ModelE-BiomeE v.1.0)

We developed a demographic vegetation model, BiomeE, to improve the modeling of vegetation dynamics and ecosystem biogeochemical cycles in the NASA Goddard Institute of Space Studies' ModelE Earth system model. This model includes the processes of plant growth, mortality, reproduction, vegetation structural dynamics, and soil carbon and nitrogen storage and transformations. The model combines the plant physiological processes of ModelE's original vegetation model, Ent, with the plant demographic and ecosystem nitrogen processes that have been represented in the Geophysical Fluid Dynamics Laboratory's LM3-PPA. We used nine plant functional types to represent global natural vegetation functional diversity, including trees, shrubs, and grasses, and a new phenology model to simulate vegetation seasonal changes with temperature and precipitation fluctuations. Competition for light and soil resources is individual based, which makes the modeling of transient compositional dynamics and vegetation succession possible. Overall, the BiomeE model simulates, with fidelity comparable to other models, the dynamics of vegetation and soil biogeochemistry, including leaf area index, vegetation structure (e.g., height, tree density, size distribution, and crown organization), and ecosystem carbon and nitrogen storage and fluxes. This model allows ModelE to simulate transient and long-term biogeophysical and biogeochemical feedbacks between the climate system and land ecosystems. Furthermore, BiomeE also allows for the eco-evolutionary modeling of community assemblage in response to past and future climate changes with its individual-based competition and demographic processes.

Biogeochemical cycles↗

Measurement of material parameters that limit the open-circuit voltage in P-N-junction silicon solar cells

The greatest gains in solar energy conversion efficiency of p-n-junction silicon solar cells come from increasing the open-circuit voltage V sub OC; it is important to understand and characterize the material parameters that limit the V sub OC. Strong experimental evidence exists to support the assertion that either an anomalously large minority carrier charge storage or an anomalously small minority carrier lifetime in the quasi-neutral emitter region limits the open circuit voltage. A method is presented for measuring charge storage and effective lifetime. Static and transient measurements are analyzed using physical models of the solar cell characteristics. This analysis yields the emitter charge storage and life-time, which then can be related to the various physical mechanisms, such as energy band gap shrinkage, that have been proposed earlier as responsible for limiting V sub OC.

Lindholm, F. A.↗

Analytical solutions to the problem of transient heat transfer in living tissue.

An analytical model of transient heat transfer in living biological tissue is considered. The model includes storage, generation, conduction, and convective transport of heat in the tissue. Solutions for rectangular and cylindrical coordinates are presented and discussed. Transient times for reaching the ?locally fully developed' temperature profile were found to be of the order of 5 to 25 min. These transients are dominated by a geometrical parameters and, to a lesser extent, by a parameter representing the ratio of heat supplied by blood flow to heat conducted in the tissue.

Shitzer, A.↗

A PCM/forced convection conjugate transient analysis of energy storage systems with annular and countercurrent flows

Latent heat energy storage systems with both annular and countercurrent flows are modeled numerically. The change of phase of the phase-change material (PCM) and the transient forced convective heat transfer for the transfer fluid are solved simultaneously as a conjugate problem. A parametric study and a system optimization are conducted. It is found that the energy storage system with the countercurrent flow is an efficient way to absorb heat energy in a short period for pulsed power load space applications.

Cao, Y.↗

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling↗

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit↗

Modeling a Transient Pressurization with Active Cooling Sizing Tool

As interest in the area of in-space zero boil-off cryogenic propellant storage develops, the need to visualize and quantify cryogen behavior during ventless tank self-pressurization and subsequent cool-down with active thermal control has become apparent. During the course of a mission, such as the launch ascent phase, there are periods that power to the active cooling system will be unavailable. In addition, because it is not feasible to install vacuum jackets on large propellant tanks, as is typically done for in-space cryogenic applications for science payloads, instances like the launch ascent heating phase are important to study. Numerous efforts have been made to characterize cryogenic tank pressurization during ventless cryogen storage without active cooling, but few tools exist to model this behavior in a user-friendly environment for general use, and none exist that quantify the marginal active cooling system size needed for power down periods to manage tank pressure response once active cooling is resumed. This paper describes the Transient pressurization with Active Cooling Tool (TACT), which is based on a ventless three-lump homogeneous thermodynamic self-pressurization model1 coupled with an active cooling system estimator. TACT has been designed to estimate the pressurization of a heated but unvented cryogenic tank, assuming an unavailable power period followed by a given cryocooler heat removal rate. By receiving input data on the tank material and geometry, propellant initial conditions, and passive and transient heating rates, a pressurization and recovery profile can be found, which establishes the time needed to return to a designated pressure. This provides the ability to understand the effect that launch ascent and unpowered mission segments have on the size of an active cooling system. A sample of the trends found show that an active cooling system sized for twice the steady state heating rate would results in a reasonable time for tank pressure recovery with ZBO of a liquid oxygen propellant tank.

Guzik, Monica C.↗

SINDA/FLUINT and Thermal Desktop Multi-Node Settled and Unsettled Propellant Tank Modeling of Zero Boil Off Test

Cryogenic propellant storage tank self-pressurization involves complex physical phenomena which are usually analytically modelled via complex multidimensional CFD codes. Unfortunately these codes, even when modelling axisymmetric domains, may takes weeks or longer to obtain transient pressure and temperature information for relatively short periods of time (several seconds to several hours). Propellant tank storage end-to-end mission simulations can last a duration of days to weeks to months. Multi-node modelling of propellant tanks is a viable alternative to traditional CFD modelling and presents the advantage of greatly reduced run times on the order of hours and days compared to the weeks or longer for CFD codes. A multi-node model represents the fluid within the storage tank, as well as the storage tank itself, as a fluid-thermal network. This type of setup is not necessarily geometrically based. This can be accomplished using a commercial generalized fluid-thermal network code, such as SINDA/FLUINT (SF). The advantage of using a fluid-thermal network code like SF lies in its extensive ability to model the external environment of the storage tank through the graphical user interface, Thermal Desktop (TD). The total heat load into the tank may be a function of heaters and a complex radiative environment as well. Thermal Desktop may be used to address the detailed radiative environment of the tank as well as building a geometrically accurate depiction of the storage tank itself.

Sakowski, Barbara↗

SINDA/FLUINT and Thermal Desktop Multi-Node Settled and Unsettled Propellant Tank Modeling of Zero Boil Off Test

Cryogenic propellant storage tank self-pressurization involves complex physical phenomena which are usually analytically modelled via complex multidimensional CFD (Computational Fluid Dynamics) codes. Unfortunately these codes, even when modelling axisymmetric domains, may take weeks or longer to obtain transient pressure and temperature information for relatively short periods of time (several seconds to several hours). Propellant tank storage end-to-end mission simulations can last a duration of days to weeks to months. Multi-node modelling of propellant tanks is a viable alternative to traditional CFD modelling and presents the advantage of greatly reduced run times on the order of hours and days compared to the weeks or longer for CFD codes. A multi-node model represents the fluid within the storage tank, as well as the storage tank itself, as a fluid-thermal network. This type of setup is not necessarily geometrically based. This can be accomplished using a commercial generalized fluid-thermal network code, such as SINDA/FLUINT (SF). The advantage of using a fluid-thermal network code like SF lies in its extensive ability to model the external environment of the storage tank through the graphical user interface, Thermal Desktop (TD). The total heat load into the tank may be a function of heaters and a complex radiative environment as well. Thermal Desktop may be used to address the detailed radiative environment of the tank as well as building a geometrically accurate depiction of the storage tank itself.

Thermal Desktop↗

Mars Propellant Liquefaction and Storage Performance Modeling using Thermal Desktop with an Integrated Cryocooler Model

NASAs current Mars architectures are assuming the production and storage of 23 tons of liquid oxygen on the surface of Mars over a duration of 500+ days. In order to do this in a mass efficient manner, an energy efficient refrigeration system will be required. Based on previous analysis NASA has decided to do all liquefaction in the propulsion vehicle storage tanks. In order to allow for transient Martian environmental effects, a propellant liquefaction and storage system for a Mars Ascent Vehicle (MAV) was modeled using Thermal Desktop. The model consisted of a propellant tank containing a broad area cooling loop heat exchanger integrated with a reverse turbo Brayton cryocooler. Cryocooler sizing and performance modeling was conducted using MAV diurnal heat loads and radiator rejection temperatures predicted from a previous thermal model of the MAV. A system was also sized and modeled using an alternative heat rejection system that relies on a forced convection heat exchanger. Cryocooler mass, input power, and heat rejection for both systems were estimated and compared against sizing based on non-transient sizing estimates.

fluid modeling↗

Mars Propellant Liquefaction Modeling in Thermal Desktop

NASAs current Mars architectures are assuming the production and storage of 23 tons of liquid oxygen on the surface of Mars over a duration of 500+ days. In order to do this in a mass efficient manner, an energy efficient refrigeration system will be required. Based on previous analysis NASA has decided to do all liquefaction in the propulsion vehicle storage tanks. In order to allow for transient Martian environmental effects, a propellant liquefaction and storage system for a Mars Ascent Vehicle (MAV) was modeled using Thermal Desktop. The model consisted of a propellant tank containing a broad area cooling loop heat exchanger integrated with a reverse turbo Brayton cryocooler. Cryocooler sizing and performance modeling was conducted using MAV diurnal heat loads and radiator rejection temperatures predicted from a previous thermal model of the MAV. A system was also sized and modeled using an alternative heat rejection system that relies on a forced convection heat exchanger. Cryocooler mass, input power, and heat rejection for both systems were estimated and compared against sizing based on non-transient sizing estimates.

Cryogenics↗

Modelled land use and land cover change emissions – a spatio-temporal comparison of different approaches

Quantifying the net carbon flux from land use and land cover changes (fLULCC) is critical for understanding the global carbon cycle and, hence, to support climate change mitigation. However, large-scale fLULCC is not directly measurable and has to be inferred from models instead, such as semi-empirical bookkeeping models and process-based dynamic global vegetation models (DGVMs). By definition, fLULCC estimates are not directly comparable between these two different model types. As an important example, DGVM-based fLULCC in the annual global carbon budgets is estimated under transient environmental forcing and includes the so-called loss of additional sink capacity (LASC). The LASC results from the impact of environmental changes on land carbon storage potential of managed land compared to potential vegetation and accumulates over time, which is not captured in bookkeeping models. The fLULCC from transient DGVM simulations, thus, strongly depends on the timing of land use and land cover changes mainly because LASC accumulation is cut off at the end of the simulated period. To estimate the LASC, the fLULCC from pre-industrial DGVM simulations, which is independent of changing environmental conditions, can be used. Additionally, DGVMs using constant present-day environmental forcing enable an approximation of bookkeeping estimates. Here, we analyse these three DGVM-derived fLULCC estimations (under transient, pre-industrial, and present-day forcing) for 12 models within 18 regions and quantify their differences as well as climate- and CO2-induced components and compare them to bookkeeping estimates. Averaged across the models, we find a global fLULCC (under transient conditions) of 2.0±0.6 PgC/yr for 2009–2018, of which ∼40 % are attributable to the LASC (0.8±0.3 PgC/yr). From 1850 onward, the fLULCC accumulated to 189±56 PgC with 40±15 PgC from the LASC. Around 1960, the accumulating nature of the LASC causes global transient fLULCC estimates to exceed estimates under present-day conditions, despite generally increased carbon stocks in the latter. Regional hotspots of high cumulative and annual LASC values are found in the USA, China, Brazil, equatorial Africa, and Southeast Asia, mainly due to deforestation for cropland. Distinct negative LASC estimates in Europe (early reforestation) and from 2000 onward in the Ukraine (recultivation of post-Soviet abandoned agricultural land), indicate that fLULCC estimates in these regions are lower in transient DGVM compared to bookkeeping approaches. Our study unravels the strong dependence of fLULCC estimates on the time a certain land use and land cover change event happened to occur and on the chosen time period for the forcing of environmental conditions in the underlying simulations. We argue for an approach that provides an accounting of the fLULCC that is more robust against these choices, for example by estimating a mean DGVM ensemble fLULCC and LASC for a defined reference period and homogeneous environmental changes (CO2 only).

land use and land cover change↗

Computer aided nonlinear electrical networks analysis

Techniques used in simulating an electrical circuit with nonlinear elements for use in computer-aided circuit analysis programs are described. Elements of the circuit include capacitors, resistors, inductors, transistors, diodes, and voltage and current sources (constant or time varying). Simulation features are discussed for dc, ac, and/or transient circuit analysis. Calculations are based on the model approach of formulating the circuit equations. A particular solution of transient analysis for nonlinear storage elements is described.

Slapnicar, P.↗

Analysis of Oxygen Liquefaction with Transient Flow Rates for ISRU Systems

Human occupation of lunar and Martian surfaces requires in-situ resource utilization (ISRU) to create a sustainable environment with the limited resources available in space. Fuel and oxidizer generation is essential for developing a refueling capability for spacecraft, significantly reducing the propellant mass required for landing. Liquefaction systems are a key step in producing and storing cryogenic liquids such as oxygen, hydrogen, and methane. All those fluids are critical to propulsion, life support, and other spacecraft systems. NASA has previously confirmed the presence of water on the Moon and an electrolysis process can be used to separate the oxygen from the hydrogen molecules. Oxygen has also been found within lunar regolith and can be separated through ISRU processes. The extracted oxygen gas can then be liquefied inside a storage tank with tube-on-tank heat exchangers for future use as an oxidizer for propellants. While steady state liquefaction performance is easy to model, power limitations and cyclical environments caused by the change in Sun exposure between day and night periods potentially call for transient operations. The following analysis was performed using the Thermal Desktop software to investigate how various transient gaseous oxygen (GOX) flow rates impact the production and storage of liquid oxygen (LOX) in a 1-g liquefaction system. Variations of sinusoidal and exponential step functions were selected to model potential GOX flow rates that could be experienced by ISRU systems on lunar or Martian surfaces. This early computational analysis provides some insight on how transient operations impact oxygen liquefaction systems and helps illustrate operational questions to explore experimentally throughout the design process.

Cryogenic Fluid Management↗

Ice Growth Model for Polar Water Capture Systems

In-situ resource utilization (ISRU) is essential to NASA’s goal of sustainable and cost-effective missions to the Moon and beyond. Water has become a particular source of interest since its discovery in the permanently shadowed regions (PSRs) of the Moon. This water exists as ice bound within the regolith, so one mode of capture is heating to sublimation temperatures and capturing at very low pressure. It then can be stored in ice form and transported out of the PSR and to a sunlit ridge, where processes such as electrolysis can be performed[2]. An understanding of frost growth dynamics under rarefied conditions is necessary for successful water capture and storage due to transient thermal properties of frost. A Diffusion-Limited Aggregation (DLA) approach was taken to analytically model bulk thermal conductivity changes of the growing frost layer under varying wall temperatures and frost layer porosities. The model utilizes well-known correlations for effective thermal conductivity and records the values as the frost layer thickness increases. This thermal conductivity can be applied to a known temperature change and be used to evaluate heat flux through the combined frost layer and tank wall for either a flat plate or cylindrical geometry. An experiment is described that will evaluate this model using one-dimensional frost growth on a horizontal, flat plate under low-pressure. The ice growth will be measured using a millimeter-scale photogrammetry camera system and a load cell measured transient mass growth.

In situ Resource Utilization↗