Search NASA⌕ Search

SEARCH · Search NASA

Results for “transition duct”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Outflow Boundary Conditions for Turbine-Integrated Rotating Detonation Combustors

This study examines outflow boundary conditions (BCs) in computational fluid dynamics (CFD) simulations of a transition duct with and without guide vanes that converts supersonic flow exiting a rotating detonation combustor (RDC) to subsonic flow to drive a turbine. Since the flow exiting the transition duct has swirling shock waves with significant spatial and temporal variations in pressure, temperature, and Mach number, imposing proper BCs poses a challenge. To ensure all swirling shock waves exit the transition duct without creating non-physical reflected waves at its outlet, this study examined three outflow BCs: (1) the average pressure imposed at the duct’s outlet, (2) a nonreflecting BC (NRBC) with a specified average pressure imposed at the duct’s outlet, (3) the average pressure imposed at the outlet of an extension duct made up of a buffer layer and a sponge layer. This study is based on the three-dimensional, unsteady density-weighted-ensemble-averaged continuity, Navier–Stokes, and energy equations for a thermally perfect gas closed by the realizable k–ε model and “enhanced” wall functions. The results obtained show that imposing an average pressure at the transition duct’s outlet produces spurious waves that degrade the physical meaningfulness of the solution. When the NRBC was applied, swirling shock waves exited the duct’s outlet without creating spurious waves. However, its usage requires the gas to be thermally, as well as calorically, perfect, which this study shows could be a concern. By imposing the average pressure at the outlet of an extension duct, the gas does not need to be calorically perfect. The results obtained show the effects of the sponge layer’s length and coarsening ratio on damping nonuniformities in non-physical reflected waves to ensure the flow exiting the transition duct’s outlet can do so as if there are no boundaries present and has the desired average pressure—even though the BC is applied at the extension duct’s outlet.

gas turbines↗

RAFT: Reconfigurable Array of High-Efficiency Ducted Turbines for Hydrokinetic Energy Harvesting

Diversifying the energy harvesting portfolio is crucial to achieving the ambitious goal of transitioning to clean energy by 2030. Marine hydrokinetic energy has garnered renewed interest due to its high harvesting potential in the U.S., and the resource's reliability and predictability—remaining relatively constant on a daily basis and available 24/7. However, there are currently few commercial devices capable of harnessing the energy from flowing water. This project aims to bridge that gap by designing and evaluating a novel hydrokinetic turbine concept that can efficiently harvest energy from both rivers and tidal streams. The RAFT (Reconfigurable Array of High-Efficiency Ducted Turbines) concept introduces a duct surrounding the turbine rotor and creates an array of small 5-kW units. The duct serves two primary purposes: (1) it enhances hydrodynamic efficiency by accelerating flow to the rotor, and (2) it functions as a structural component, facilitating the formation of modular arrays that lower costs. This project focuses on demonstrating this concept and validating these benefits through simulations and scaled prototype testing. The project team includes 8 faculty members and over 20 students from 3 universities, organized into three core areas: hydrodynamics, electrical systems, and structural analysis, with additional teams dedicated to system integration, environmental assessment and risk management, and tech-to-market strategy. The team successfully demonstrated the increased hydrodynamic efficiency of a ducted turbine compared to an unducted version using high-fidelity simulations and prototype tests. Moreover, design optimization efforts led to surpassing the SHARKS program's goal of 60% reduction of the levelized cost of energy with a significant margin.

13 HYDRO ENERGY↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low fractional volume superconductivity in single crystals of Pr{sub 4}Ni{sub 3}O{sub 10} under pressure

Magnetotransport measurements of P⁢r4⁢N⁢i3⁢O10 single crystals performed under externally applied pressures up to 73 GPa in diamond anvil cells with either KBr or Nujol oil as pressure media yield signatures of superconductivity with a maximum onset temperature of approximately 31 K. True zero resistance was not observed, consistent with a nonpercolating superconducting volume fraction. Magnetization measurements provided corroborating evidence of superconductivity, with a pressure-dependent diamagnetic signal occurring below the onset temperature, and an estimate from the absolute value of the susceptibility suggests a superconducting volume fraction on the order of 10%. We observe sample to sample variations in the magnitude and pressure dependence of 𝑇𝑐 as well as a dependence on the configuration of electrical contacts on a given sample. Possible causes of this behavior may be significant inhomogeneities in the pressure and/or damage to the samples induced by the pressure media as well as inhomogeneities in the crystals themselves. The results imply that our as-grown P⁢r4⁢N⁢i3⁢O10 single crystals are not bulk superconductors but that there is a minority structure present within the crystals that is indeed superconductin

Chen, Xinglong↗