Search NASA⌕ Search

SEARCH · Search NASA

Results for “transmission line measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Plasma-free hydrogenation of oxygen-terminated polycrystalline diamond as determined by circular transmission line measurements (CTLM)

Here, we developed a process to fully hydrogen-terminate diamond by annealing in forming gas. The surface was characterized using circular transmission line measurements (CTLMs) to evaluate the onset and degree of hydrogen termination. No hydrogenation occurred at temperatures at or below 500 °C. Hydrogenation occurs after annealing for 5 min at temperatures between 600 and 1000 °C, with complete hydrogenation achieved at 1000 °C, which showed the same sheet resistance as diamond terminated in a hydrogen plasma. Annealing at temperatures lower than 1000 °C resulted in only partial hydrogenation but can be compensated by increasing the anneal time. At temperatures exceeding 1100 °C, the sheet resistance suddenly and drastically increases, indicating instability of a hydrogen-terminated diamond surface at elevated temperatures under forming gas. The activation energy was determined to be 1.20eV. SEM inspection showed that annealing in hydrogen produced significantly reduced surface roughness compared to diamond surfaces hydrogenated in a H 2 plasma.

36 MATERIALS SCIENCE↗

Characterization of Mn 5 Ge 3 Contacts on a Shallow Ge/SiGe Heterostructure

Mn 5 Ge 3 is a ferromagnetic phase of the Mn-Ge system that is a potential contact material for efficient spin injection and detection. Here, we investigate the creation of Mn 5 Ge 3 -based contacts on a Ge/SiGe quantum well heterostructure via solid-state synthesis. X-ray diffraction spectra fitting indicates the formation of Mn 5 Ge 3 -based contacts on bulk Ge and Ge/SiGe. High-resolution scanning transmission electron microscopy imaging and energy dispersive X-ray spectroscopy verify the correct Mn 5 Ge 3 -based phase formation. Schottky diode measurements, transmission line measurements, and Hall measurements reveal that Mn 5 Ge 3 -based contacts serve as good p-type contacts for Ge/SiGe quantum well heterostructures due to having a low Schottky barrier height of 0.10 eV (extracted from a Mn 5 Ge 3 /n-Ge analogue) and a contact resistance in the order of 1 kΩ. Furthermore, we show that these electrical characteristics have a gate-voltage dependence, thereby providing tunability.

36 MATERIALS SCIENCE↗

Development of a colinear Second-Harmonic Orthogonal Polarization (SHOP) interferometer for electron areal density measurements in Magnetically Insulated Transmission Lines (MITLs)

Experimental measurements of low density plasmas forming in Magnetically Insulated Transmission Line (MITL) regions are desired to improve our understanding of current loss and power flow. Therefore, a new optical interferometer diagnostic was commissioned via this LDRD project. To measure the expected 10 13 - 10 17 cm -3 electron densities inside the 0.5 - 6 mm Anode-Cathode (A-K) gaps, a colinear SHOP interferometer diagnostic was constructed. The diagnostic was initially fielded on the University of New Mexico (UNM) Helicon-Cathode (HelCat) plasma device which provided a highly repeatable and well understood plasma source for which the colinear SHOP interferometer’s functionality could be verified and measured. Utilizing the highly repeatable plasma source and shot averaging, the interferometer was able to achieve an areal density sensitivity of 1×10 14 cm -2 . This work at UNM lead to a Review of Scientific Instruments (RSI) publication [20], DOI:10.1063/5.0101687. After the diagnostic’s capability was proven at UNM, the colinear SHOP interferometer was commissioned for use on the Sandia National Laboratories (SNL) Mykonos accelerator. Here, it provided the first temporal areal density measurements of plasma formation in a parallel plate MITL. The diagnostic was able to achieve a single shot (no multi-shot averaging like at UNM) areal density sensitivity of 1×10 15 cm -2 along a ~ 2mm probing path length, which provided adequate capability to conduct fundamental physics research of MITL plasma formation. CHICAGO and ALEGRA simulations support the diagnostics experimental findings. More experimental and computational work will continue, likely leading to another publication(s). The smaller scale Mykonos accelerator work has also provided justification that the colinear SHOP interferometer is a capable diagnostic for measuring plasma areal densities in the inner MITL and convolute regions of larger TW-class accelerators like SNL’s Z machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Approaching the Practical Conductivity Limits of Aerosol Jet Printed Silver

Previous efforts to directly write conductive metals have been narrowly focused on nanoparticle ink suspensions that require aggressive sintering (>200°C) and result in low-density, small-grained agglomerates with electrical conductivities <25% of bulk metal. Here, we demonstrate aerosol jet printing of a reactive ink solution and characterize high-density (93%) printed silver traces having near-bulk conductivity and grain sizes greater than the electron mean free path, while only requiring low temperature (80°C) treatment. We have developed a predictive electronic transport model which correlates the microstructure to the measured conductivity and identifies a strategy to approach the practical conductivity limit for printed metals. Our analysis of how grain boundaries and tortuosity contribute to electrical resistivity provides insight into the basic materials science that governs how an ink formulator or process developer might approach improving the conductivity. Transmission line measurements validate that electrical properties are preserved up to 20GHz, which demonstrates the utility of this technique for printed RF components. Finally, this work reveals a new method of producing robust printed electronics that retain the advantages of rapid prototyping and three-dimensional fabrication while achieving the performance necessary for success within the aerospace and communications industries.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Self‐Assembled Monolayer Templating for Engineered Nanopinholes in Passivated Contact Solar Cells

We present a novel self-assembled monolayer (SAM)-based technique to make nanopinhole-enabled passivated contacts on silicon solar cells by tuning the SAM coverage area and etch selectivity. We deposit trimethyl-silyl Si(CH 3 ) 3 groups using hexamethyldisilazane (HMDS) as the precursor over passivating dielectric layers and their stacks (SiO 2 , SiN x , SiO 2 /SiN x ) and interrupt the HMDS attachment chemistry shortly before a full monolayer is formed on its surface. Subsequent etching in dilute HF produces pinholes through the dielectric layers due to the higher etch resistance of the SAM to HF etching. The pinhole areal density (10 4 –10 8 /cm 2 ) and size (10–1000 nm) can be tuned both by duration of HMDS attachment and HF etch time. Pinholes were characterized by atomic force microscopy, tetramethylammonium hydroxide (TMAH) selective etch, and Ag decoration by electroless plating. Polysilicon (poly-Si) passivated contacts enabled by pinholes were formed by subsequent deposition of doped amorphous silicon (a-Si:H) followed by thermal crystallization and dopant drive-in. At optimal areal pinhole density ≈10 7 /cm 2 , contacts exhibit both passivation and carrier transport via pinholes as evidenced by electron beam induced current, transmission line measurements, and carrier lifetime measurements. Solar cells based with these pinhole contacts show V oc = 723 mV and FF = 80.3%. The remaining SAM layer does not affect device performance.

14 SOLAR ENERGY↗

p-type conductivity and damage recovery in implanted GaN annealed by rapid gyrotron microwave annealing

We demonstrate p-type activation of GaN doped by Mg ion implantation, and in situ during metalorganic chemical vapor deposition through sequential short-duration gyrotron microwave heating cycles at temperatures of 1200–1350 °C. GaN is implanted with 1019 cm−3 Mg ions, capped with AlN, and annealed under 3 MPa N2 overpressure in 5 s heating cycles for less than 60 s total using a high-power gyrotron microwave heating source. Through I–V characterization, photoluminescence spectroscopy, and Raman spectroscopy, we study the evolution of electrical properties, optically active point defects, and material strain in response to implantation and annealing. For Mg-implanted samples, increasing annealing temperature is characterized by an increase in the PL substitutional Mg-related peak (UVL) relative to the shallow-donor vacancy-related peak (GL2). Through comparison of implanted and in situ doped samples, it is demonstrated that the origin of compensating VN lies primarily in implantation rather than degradation from the annealing process. Transmission line measurements and diode I–V measurements show a sheet resistance of 1083 kΩ/□ and a hole concentration of 1.23 × 1015 cm−3, respectively, in the Mg-implanted material annealed at 1350 °C. We conclude that temperature-cycled gyrotron annealing at 1350 °C decreases implant-induced compensating point defects and activates Mg to obtain selective p-type conduction.

Meyers, V. (ORCID:0000000176731553)↗

Investigation of Ga 2 O 3 as a new transparent conductive oxide for photovoltaics applications

This small innovation project intended to leverage recent activity and advances in ultrawide-bandgap oxide power electronics toward the investigation of Ga 2 O 3 as a transparent conductive oxide (TCO) for use in photovoltaics (PV). Ga 2 O 3 ’s theoretical advantage over incumbent TCOs is its very large bandgap of 4.8 eV, ensuring optical transparency of photons with λ ≥ 260 nm, effectively the full terrestrial solar spectrum. At the time of proposal writing, literature on Ga 2 O 3 as a TCO/optical material was relatively sparse — what little existed was focused on for UV sensors and/or emitters, with none related to PV. As such, this project was intended to help determine the potential of Ga 2 O 3 as a PV-oriented TCO by investigating its deposition using tools common to the PV and electronics industries — atomic layer deposition (ALD) and RF sputtering (RS), both of which are already used in PV manufacturing — and its resultant optical and electronic properties. Final project goals were to test its application to Si and III-V solar cells. Controllable film thickness and excellent uniformity was established for both methods deposition methods, with ALD providing higher precision for thinner films and RS more effective for growing thicker films. The as-deposited films were found to be amorphous in nature. Spectroscopic ellipsometry (SE) confirmed bandgaps of at least 4.8 eV and non-parasitic absorption across both AM0 and AM1.5G spectra; a refractive index approaching the expected value of 1.8 was also observed, with some degree of tunability based on process parameters. Using this initial optical data, a transfer matrix model, which interfaces with in-house EQE and LIV models, was developed to simulate Ga 2 O 3 optical effects on various solar cells, included potential in antireflection coatings (ARCs). Despite promising optical properties, the resultant resistivity / conductivity metrics did not meet expectations, regardless of deposition process. Although thick RS-deposited films, using both undoped and 1 at% Ge (n-type) doped sintered targets — demonstrated high net carrier concentrations (via C-V), and low specific resistance Ohmic contacts were demonstrated, transmission line measurements (TLM) showed very high resistivity. Further analysis indicated high vertical film conductivity, but very low lateral conductivity. Deeper characterization revealed a relatively high density of nano/microcrystalline inclusions that were ostensibly the source of the vertical conductivity, with the amorphous matrix serving as an effective insulator (likely due to high concentrations of electronic trap states). Despite extensive work to increase film polycrystallinity — demonstrated via high temperature annealing — sufficient lateral conductivity for TCO use was not achieved. The final phase of the project shifted focus toward investigation of ALD-deposited Ga 2 O 3 ’s potential as a passivant and/or passivating contact for both Si and III-V solar cells, with expectation of performance similar to Al 2 O 3 . However, initial rounds of testing using our baseline ALD process yielded minimal (but not quite zero) passivation of both GaInP and Si surfaces. Dielectric passivation is well-known to be highly process sensitive; given the unoptimized nature of the process used, this work was deemed inconclusive. The final outlook with respect to feasibility of Ga 2 O 3 as a PV-oriented TCO is, ultimately, still uncertain. The work performed in this project confirmed the optical properties and deposition methods, but the achieved electrical properties do not meet technological needs; literature reports in recent years are somewhat inconsistent and potentially untrustworthy, but generally appear to be in line with our results. At the very least it is clear that, should Ga 2 O 3 still be under consideration for PV TCO and/or selective contact applications, a significant amount of optimization and study is still needed.

14 SOLAR ENERGY↗

Noncontact Monitoring of Overhead Transmission Lines Using Space Potential Phasor Measurements

Power system reliability requirements necessitate the development of measurement systems to monitor the operational state of critical transmission lines. Here in this article, a novel noncontact method for monitoring overhead transmission lines is proposed. The method is based on measuring the amplitude and relative phase of the transmission line's space potential at two or more strategically located points in space along with the use of passive phase shifters to enhance the sensitivity of the measurements. Applications of voltage unbalance and conductor sag measurements are demonstrated along with the results of conductor sag measurements on an operating 230-kV transmission line. It is shown that using enhanced relative phase measurements can significantly improve the sensitivity of the measurements.

47 OTHER INSTRUMENTATION↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Series tee splitter for impedance measurements

A series tee splitter comprises a primary electromagnetic transmission line and a secondary electromagnetic transmission line that is placed in a series path with the primary electromagnetic transmission line, wherein a load is attached to the end of the secondary electromagnetic transmission line and a network analyzer is connected to opposite ends of the primary electromagnetic transmission line to measure a load impedance. This configuration increases the high impedance measurement limit of the network analyzer normally seen for reflection measurements. The series tee splitter can be electrically small to provide broadband impedance information.

Halligan, Matthew↗

Degradation of Monocrystalline Silicon Photovoltaic Modules From a 10-Year-Old Rooftop System in Florida

A system of 180 monocrystalline aluminum back-surface field modules were installed in Cocoa, Florida, for 10 years. In total, 156 modules are characterized and compared to 3 controls. Power degradation rates vary between – 0.14% to – 3.22% per year, with median and average rates of –0.92% and –1.05% per year, respectively. The losses are primarily resistive with minor optical and recombination loss contributions. Electroluminescence imaging shows a characteristic pattern, which is shown to be resistive in nature when compared to photoluminescence. Resistive losses are due to corrosion of the rear contact Ag/solder interface and, to a much lesser degree, gridline Ag oxidation. Moisture ingress through the backsheet is likely responsible for mediating corrosion. Optical losses are due mostly to a combination of antireflection coating degradation, minor encapsulant browning, and delamination. Minor front contact corrosion may contribute to recombination. Furthermore, this study expands upon previous work on this vintage of the module by examining a large sample set, comprehensive characterization including techniques not previously used on these modules, and a comparison between two other systems of different climates.

14 SOLAR ENERGY↗

A Hybrid DC Fault Primary Protection Algorithm for Multi-Terminal HVdc Systems

Protection against dc faults is one of the main technical hurdles faced when operating converter-based HVdc systems. Protection becomes even more challenging for multi-terminal dc (MTdc) systems with more than two terminals/converter stations. In this paper, a hybrid primary fault detection algorithm for MTdc systems is proposed to detect a broad range of failures. Sensor measurements, i.e., line currents and dc reactor voltages measured at local terminals, are first processed by a top-level context clustering algorithm. For each cluster, the best fault detector is selected among a detector pool according to a rule resulting from a learning algorithm. The detector pool consists of several existing detection algorithms, each performing differently across fault scenarios. The proposed hybrid primary detection algorithm: i) offers superior performance compared to an individual detector through a data-driven approach; ii) detects all major fault types including pole-to-pole (P2P), pole-to-ground (P2G), and external dc faults; iii) identifies faults with various fault locations and impedances; iv) is more robust to noisy sensor measurements compared to existing methods; v) does not require exhaustive simulation and sampling for training the model. Performance and effectiveness of the proposed algorithm are evaluated and verified based on time-domain simulations in the PSCAD/EMTDC software environment. The results confirm satisfactory operation, accuracy, and detection speed of the proposed algorithm under various fault scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Bayesian inferences of electrical current delivered to shocked transmission lines

Small radius Bdot measurements of electrical current delivered by pulsed power devices are routinely compromised by electrode/convolute plasmas endemic to multiterawatt transmission lines. Inferences of delivered current unaffected by these issues have recently been obtained by numerically optimizing consistency between model predictions and local experimental velocimetry data, but these are only unique for shockless velocity profiles. In the paper we describe a more general Bayesian method capable of inferring current despite the presence of shocks. Additionally, we describe uncertainty estimates and use of the technique on experimental data. This technique is the first to provide uncertainty estimates on the full current trace delivered to an inertial confinement fusion target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗