Search NASASearch

SEARCH · Search NASA

Results for “trapped ions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Integrated-photonics-based systems for polarization-gradient cooling of trapped ions

Trapped ions are a promising modality for quantum systems, with demonstrated utility as the basis for quantum processors and optical clocks. However, traditional trapped-ion systems are implemented using complex free-space optical configurations, whose large size and susceptibility to vibrations and drift inhibit scaling to large numbers of qubits. In recent years, integrated-photonics-based systems have been demonstrated as an avenue to address the challenge of scaling trapped-ion systems while maintaining high fidelities. While these previous demonstrations have implemented both Doppler and resolved-sideband cooling of trapped ions, these cooling techniques are fundamentally limited in efficiency. In contrast, polarization-gradient cooling can enable faster and more power-efficient cooling and, therefore, improved computational efficiencies in trapped-ion systems. While free-space implementations of polarization-gradient cooling have demonstrated advantages over other cooling mechanisms, polarization-gradient cooling has never previously been implemented using integrated photonics. In this paper, we design and experimentally demonstrate key polarization-diverse integrated-photonics devices and utilize them to implement a variety of integrated-photonics-based polarization-gradient-cooling systems, culminating in the first experimental demonstration of polarization-gradient cooling of a trapped ion by an integrated-photonics-based system. By demonstrating polarization-gradient cooling using an integrated-photonics-based system and, in general, opening up the field of polarization-diverse integrated-photonics-based devices and systems for trapped ions, this work facilitates new capabilities for integrated-photonics-based trapped-ion platforms.

atom optics

3D-printed micro ion trap technology for quantum information applications

Trapped-ion applications, such as in quantum information processing1, precision measurements, optical clocks and mass spectrometry, rely on specialized high-performance ion traps. The last three of these applications typically use traditional machining to customize macroscopic 3D Paul traps, whereas quantum information processing experiments usually rely on photolithographic techniques to miniaturize the traps and meet scalability requirements. Using photolithography, however, it is challenging to fabricate the complex 3D electrode structures required for optimal confinement. Here, in this work, we demonstrate a high-resolution 3D printing technology based on two-photon polymerization (2PP) that is capable of fabricating large arrays of high-performance miniaturized 3D traps. We show that 3D-printed ion traps combine the advantages, such as strong radial confinement, of traditionally machined 3D traps with on-chip miniaturization. We trap calcium ions in 3D-printed ion traps with radial trap frequencies ranging from 2 MHz to 24 MHz. The tight confinement eases ion cooling requirements and allows us to implement high-quality Rabi oscillations with Doppler cooling only. Also, we demonstrate a two-qubit gate with a Bell-state fidelity of 0.978 ± 0.012. With 3D printing technology, the design freedom is greatly expanded without sacrificing scalability and precision, so that ion trap geometries can be optimized for higher performance and better functionality.

quantum information

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Evaluation of the characteristics of a field emission cathode for use in a Mercury ion trap frequency standard

The performance is reported of a field emission array characterized for the purpose of replacing the filament in a trapped ion frequency standard. This dark electron emitter eliminates the need for the interference filter currently used in the trapped ion standard. While reducing the filament's unwanted light, this filter causes a significant reduction in the signal. The magnetic field associated with the filament is also eliminated, thus potentially improving the present stability of the trapped ion standard. The operation of the filament in the present system is described, as well as the associated concerns. The cathode considered for the filament's replacement is then described along with the experimental system. Experimental results, observations, and conclusions are presented.

Christman, J. M.

Exploring transport-enabled gates with integrated optical addressing to demonstrate high fidelity control of trapped ion qubits in a scalable quantum computer

In recent years, experiments involving micofabricated surface ion traps have grown in complexity, and as this complexity grows, a common design has emerged in the form of quantum charge-coupled device architecture. This architecture, already utilized on multiple systems, supports multiple zones on a device for areas such as memory or computation. The shutting process between these zones is a process often seen to be minimized. An additional component to scalable surface trapped-ion experiments includes some form of integrated photonics, as free space lasers have difficulty scaling to many ions. Here, we discuss recent results in utilizing the shuttling process with integrated photonics to perform a specific type of gate, as well as demonstrating state preparation. Furthermore, we show that these gates can be utilized as a type of optical modulator as the Doppler shift that occurs during shuttling will make the light seen by shuttled ions different than that seen by stationary ions. Furthermore, we show that the shuttling operation can be utilized as an optical modulator, where the Doppler shift changes the frequency from that of a stationary ion.

42 ENGINEERING

Recent developments and proposed schemes for trapped ion frequency standards

Ion traps are exciting candidates as future precision frequency sources. Recent developments demonstrate that mercury ion frequency standards are capable of a stability performance comparable to commercial cesium standards. There is, however, considerable room for improvement with regard to the signal to noise problem. The 40 GHz microwave frequency implies that a careful design should be implemented to ensure the elimination of the unwanted side bands in the microwave pump signal. A long life, high performance light source to be used in a trapped mercury ion microwave standard must be developed and the long term performance of a trapped mercury ion microwave standard must be investigated. While newly proposed two photon pumping schemes in conjuction with mercury ions promise exciting developments for both microwave and optical frequency standards, other ions that may be potential candidates should be evaluated for their usefulness.

Maleki, L.

A high-performance Hg(+) trapped ion frequency standard

A high-performance frequency standard based on (199)Hg(+) ions confined in a hybrid radio frequency (RF)/dc linear ion trap is demonstrated. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. A 160-mHz-wide atomic resonance line for the 40.5-GHz clock transition is used to steer the output of a 5-mHz crystal oscillator to obtain a stability of 2 x 10(exp -15) for 24,000-second averaging times. Measurements with a 37-mHz line width for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is better than 1 x 10(exp -15) at 10,000-second averaging times.

Prestage, J. D.

Ultra-stable Hg(+) trapped ion frequency standard

We report the development of a fieldable frequency standard based on Hg-199(+) ions confined in a hybrid r.f./dc linear ion trap. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the r.f. confining fields. A 160 mHz wide atomic resonance line for the 40.5 GHz clock transition is used to steer the output of a 5 MHz crystal oscillator to obtain a stability of 2 x 10 exp -15 for 24,000 s averaging times. For longer averaging intervals, measurements are limited by instabilities in available hydrogen maser frequency standards. Measurements with 37 mHz linewidth for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is at least as good as 1 x 10 exp -15.

Prestage, J. D.

Linear ion trap based atomic frequency standard

In order to develop a trapped ion-based fieldable frequency standard with stability 1 x 10 to the -13th/sq rt tau for averaging times tau greater than 10,000 s, a hybrid RF/DC linear ion trap was developed which permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. The authors have confined Hg-199(+) ions in this trap and have measured very high Q transitions with good SNRs. In preliminary measurements they obtained stabilities of 1.6 x 10 to the -13th/sq rt tau (tau between 50 and 800 s) with a 160-mHz wide atomic resonance linewidth and a signal-to-noise ratio of 40 for each measurement cycle. Atomic resonance lines as narrow as 30 mHz on the 40.5-GHz clock transition have been measured with no appreciable reduction in the ion signal. A stability of 7 x 10 to the -14th/sq rt tau is made possible by the signal-to-noise and line Q of this measured transition. Analysis of fundamental sources of frequency instability indicates that a long-term stability of 2 x 10 to the -16th is feasible for this device with existing technology for tau = 10 to the 6th s or more.

Prestage, John D.

Ultra-stable Hg(+) trapped ion frequency standard

A fieldable trapped ion frequency standard based on Hg-199(+) ions confined in a hybrid rf/dc linear ion trap is developed. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the rf confining fields. In preliminary measurements a stability of 2 to 3 x 10(exp -15) was obtained for 10000 second averaging times. These measurements were carried out with a 120 mHz wide atomic resonance line for the 40.5 GHz clock transition with a second order Doppler shift from the rf trapping field of 6 x 10(exp -13).

Prestage, John D.

Ion Traps and Packaging for Heterogenous Integration - Chimera

Microfabricated surface ion traps and silicon-based photonics are critical technologies for scaling quantum systems. Current ion trap architectures face scalability and integration challenges due to limitations in optical access, fabrication techniques, and material compatibility. State-of-the-art quantum computers and atomic clocks are investigating monolithic integration, which necessitates custom traps for each ion species and has not overcome the integration hurdles presented by merging these technologies. The Chimera (Ion Traps and Packaging for Heterogeneous Integration) project proposes a novel approach utilizing heterogeneous integration (HI) of ion traps and photonic circuits. This separation of components allows for flexibility in ion trap design and reduces fabrication compromises. The Chimera project specifically designed an ion trap to interface vertically with a separately fabricated waveguide chip and demonstrates the first steps to integrating them at the packaging level. The ion trap features a large area of removed silicon, allowing the photonics chip outputs closer to the ion trap, improving alignment and packaging processes. The alignment must be accurate to < 1 µm to ensure that the light from the waveguide can overlap with the trapping region. This fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. By combining separate chips, we demonstrate a new path for scaling trapped ion technology that is less reliant on monolithic integration. We successfully fabricated a trap with a large area of oxide removed, resulting in a region thinned to about 40 µm, a key milestone toward successful integration.

42 ENGINEERING

Theory of the thermionic current beyond the traditional space charge limit enabled by trapped ions in the virtual cathode

We show that trapped ions in virtual cathode potential wells can raise the transmitted current of emitted electrons into a plasma much closer to the full emission than is predicted by cathode sheath theories without trapped ions. The transmitted current is controlled by the well barrier voltage, which must adjust to balance the creation of low-energy ions within the well, and their loss. Our model considers the case of a plasma-facing cathode where trapped ions are created passively via charge-exchange collisions and lost passively via thermal leakage over the well. We quantify these rates and estimate the current in terms of system parameters for thermionic emission into a plasma with several cathode geometries. A general prediction is that the current as a function of emitted flux does not saturate at the traditional space charge limit (the onset of a well) but can reach far higher values until the trapped ion balance breaks down, causing instability. The maximum stable current depends on parameters but in principle can be arbitrarily high if active techniques are used to manipulate the trapped ion balance. We conclude that major improvements in plasma technologies with hot cathodes might be achieved by optimizing the current enhancement enabled by trapped ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Design and fabrication of ion traps for low RF power dissipation

Large surface-electrode ion traps with multiple trapping regions and junctions are a natural approach to scaling trapped ion quantum computers, supporting the connectivity and ion counts necessary for complex quantum algorithms. However, a major hurdle in this scaling is on-chip power dissipation from the applied RF voltage, which increases at a rate between linear and cubic relative to trap size, depending on whether the losses are dielectric or Ohmic. Here, we present two versions of a trap with features designed to reduce both types of RF power dissipation. The first variant contains a raised RF electrode that increases the electrode–ground distance to reduce capacitance. Different DC voltage sources are demonstrated on this trap to show that technical noise before the filter remains the dominant source of voltage noise and therefore motional heating. The second variant additionally includes a method for removing dielectric from beneath the RF electrode to further reduce dielectric losses. These traps were demonstrated at room temperature with 40 Ca + ions. In conclusion, the similar heating rates and heating rate axial frequency dependencies between 2.4 and 3.0 MHz illustrate that this dielectric modification is not detrimental to trap performance.

Sterk, J. D. [Sandia National Laboratories (SNL-NM

Extended linear ion trap frequency standard apparatus

A linear ion trap for frequency standard applications is provided with a plurality of trapping rods equally spaced and applied quadruple rf voltages for radial confinement of atomic ions and biased level pins at each end for axial confinement of the ions. The trapping rods are divided into two linear ion trap regions by a gap in each rod in a common radial plane to provide dc discontinuity, thus dc isolating one region from the other. A first region for ion-loading and preparation fluorescence is biased with a dc voltage to transport ions into a second region for resonance frequency comparison with a local oscillator derived frequency while the second region is held at zero voltage. The dc bias voltage of the regions is reversed for transporting the ions back into the first region for fluorescence measurement. The dual mode cycle is repeated continuously for comparison and feedback control of the local oscillator derived frequency. Only the second region requires magnetic shielding for the resonance function which is sensitive to any ambient magnetic fields.

Prestage, John D.

Studying Open Quantum Systems Relevant to Chemistry on a Trapped-Ion Quantum Simulator (Final Technical Report)

This project advances the trapped-ion quantum simulator as a versatile platform for studying open quantum system phenomena. We aim to contribute to the emerging quantum simulation toolkits and enable simulation of nanoscale energy processes. Trapped-ion platforms offer unique capabilities: their vibrational motion can be precisely manipulated, measured, and coherently coupled to auxiliary qubits. The vibrational mode can function both as a highly sensitive quantum sensor and a programmable environment bath. Using this platform, we achieved three major outcomes. First, we demonstrated using the vibrational mode as an ultrasensitive probe for testing fundamental physics, including possible nonlinear quantum mechanics effects. Second, we established that these modes can act as controllable baths in which tunable noise and loss can enhance or modify energy-transfer dynamics, providing the experimental preparation toward studying mechanisms relevant to chemical reactions and light-harvesting systems. Third, by introducing controllable nonlinear gain and loss, we showed theoretically how simulations using trapped ions can model vibrationally-assisted energy transport in a non‐Hermitian quantum system comprising a chromophore dimer weakly coupled to a vibrational mode. Exploring the non‐Hermitian dynamics of the whole system including vibrations, we found that energy transfer accompanied by absorption of phonons from a vibrational mode can be significantly enhanced near an exceptional point. This theoretical work on simulation of energy transfer processes in driven non‐Hermitian quantum systems revealed an interesting novel path to study open quantum systems dynamics under conditions of gain and loss. We then further explored the benefits of controllable gain and loss with an experimental realization of quantum analogs of nonlinear oscillators, namely, the van der Pol oscillator. Here we observed mutual synchronization mediated by collective dissipation between two oscillators. In parallel, we explored related quantum networking protocols using the same trapped-ion platform, developing fast, high-fidelity schemes for distributing entanglement. Together, these achievements show that trapped-ion vibrational modes provide a highly programmable and high-fidelity platform for investigating complex dissipative quantum behavior, while enabling new approaches to remote quantum sensing, energy science, and nonlinear quantum dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

The streaming-trapped ion interface in the equatorial inner magnetosphere

Spacecraft measurements of core ions on L=4-7 field-lines typically show trapped ion distributions near the magnetic equator, and frequently indicate field-aligned ion streams at higher latitudes. The nature of the transition between them may indicate both the microphysics of hot-cold plasma interactions and overall consequences for core plasma evolution. We have undertaken a statistical analysis and characterization of this interface and its relation to the equatorial region of the inner magnetosphere. In this analysis, we have characterized such features as the equatorial ion flux anisotropy, the penetration of field-aligned ionospheric streams into the equatorial region, the scale of the transition into trapped ion populations, and the transition latitude. We found that most transition latitudes occur within 13 deg of the equator. The typical values of equatorial ion anisotropies are consistent with bi-Maxwellian temperature ratios of T(sub perpendicular)/T(sub parallel) in the range of 3-5. The latitudinal scales for the edges of the trapped ion populations display a rather strong peak in the 2-3 deg range. We also found that there is a trend for the penetration ratio, the anisotropy half width, and the transition scale length to decrease with a higher equatorial ion anisotropy. We may interpret these features in terms of Liouville mapping of equatorially trapped ions and the reflection of the incoming ionospheric ion streams from the equatorial potential peaks associated with such trapped ions.

Lin, J.

Real-Time Quantitative Analysis of H2, He, O2, and Ar by Quadrupole Ion Trap Mass Spectrometry

The use of a quadrupole ion trap mass spectrometer for quantitative analysis of hydrogen and helium as well as other permanent gases is demonstrated. The customized instrument utilizes the mass selective instability mode of mass analysis as with commercial instruments; however, this instrument operates at a greater RF trapping frequency and without a buffer gas. With these differences, a useable mass range from 2 to over 50 Da is achieved, as required by NASA for monitoring the Space Shuttle during a launch countdown. The performance of the ion trap is evaluated using part-per-million concentrations of hydrogen, helium, oxygen and argon mixed into a nitrogen gas stream. Relative accuracy and precision when quantitating the four analytes were better than the NASA-required minimum of 10% error and 5% deviation, respectively. Limits of detection were below the NASA requirement of 25-ppm hydrogen and 100-ppm helium; those for oxygen and argon were slightly higher than the requirement. The instrument provided adequate performance at fast data recording rates, demonstrating the utility of an ion trap mass spectrometer as a real-time quantitative monitoring device for permanent gas analysis.

Ottens, Andrew K.

Four-Sector Cylindrical Radio-Frequency Ion Trap

Proposed linear radio-frequency ion trap consists of closed metal cylinder partitioned into four equal cylindrical-sector electrodes and two circular end electrodes. Features include relatively large ion-storage capacity and shielding against external fields. Used in frequency-standard laboratories to confine 199Hg+ ions electrodynamically in isolation from external environment. Similar to device described in "Linear Ion Trap for Atomic Clock" (NPO-17758).

Melbourne, Ruthann K.