Search NASA⌕ Search

SEARCH · Search NASA

Results for “traveling wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design workflow of a symmetric traveling wave antenna for fast ion production on DD tokamaks

Initial computational plasma physics scoping and a finite element method antenna modeling design workflow for a symmetric center-fed high-field side high harmonic fast wave traveling wave array (TWA) antenna are reported here. The TWA is designed to generate a test population of fast deuterium ions in an existing D–D tokamak by heating neutral beam deuterium ions, accelerating them from 80 keV to several hundred keV. The resulting fast particles are tailored to mimic key reactor energetic particle parameters with regards to exciting Alfven eigenmode instabilities, allowing for a D–D tokamak like DIII-D or ASDEX-U to replicate reactor-relevant conditions experimentally. Initial scenario scoping for high single-pass absorption as well as good preferential fast ion damping relative to electron damping was completed using the ray-tracing/Fokker–Planck codes GENRAY and CQL3D. Python RF network analysis packages were used to create a custom TWA optimization tool to inform a COMSOL flat antenna design, and Petra-M was used to study cold plasma effects. The TWA produced by this workflow has several novel features when compared to previous TWA studies, including symmetric center feeding, and passive end straps for image current cancellation for reduced impurity production. We show here that the antenna design workflow can readily produce TWA antennas optimized for reflection coefficient, image current cancellation, and launched power spectrum shape; and that a population of fast ions can be generated in the correct region of parameter space, warranting future more detailed studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IoT-Enabled Traveling Wave Microgrid Protection

Traveling Wave Protection based on the Internet of Things (TWP-IoT) is developed to enable ultra-resilient microgrids. TWP-IoT adopts a directional traveling wave approach that utilizes the voltage and current modal components obtained from Discrete Hilbert Transform to identify the fault features via ultra-lightweight IoT hardware. Furthermore, the main contributions of this work include (1) a novel TWP-IoT for microgrid and distribution networks that can achieve the time-of-arrival fault detection and localization with composite wave impedance and conductance using Discrete Hilbert Transform, (2) a cost-effective smart IoT prototype with functionalities outperforming commercial relays, and (3) a real-time hardware-in-the-loop prototype based on RTDS that verifies the robustness and efficacy of TWP-IoT subject to a diverse set of working conditions. TWP-IoT is found to have excellent performance under a wide spectrum of internal and external fault conditions across a myriad of microgrid locations, which is unattainable by today’s TWP products.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progress and challenges in traveling-wave (TW) SRF cavity

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

43 PARTICLE ACCELERATORS↗

Development of a Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, to advancing TW technologies necessary more for future accelerator-scale one, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell,. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Development efforts toward a TW 7-cell has been in progress. Here we report the recent activities and progresses of those.

Furuta, F.↗

Development of a half-meter scale Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, the RF design process of 0.5~1 meter scale TW cavity was begun at Fermilab for advancing TW technologies necessary more for future accelerator-scale one. Considering the physical dimensions of existing SRF facilities (for fabrication, processing, and cryogenic testing) and the lessons learned from the 3-cell, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Here we report a preliminary RF design, development plans, and activities.

43 PARTICLE ACCELERATORS↗

Mock-up Waveguide Loop Development toward a half-meter scale Traveling-Wave (TW) SRF cavity

Traveling-Wave (TW) technology can push the accelera-tor field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The success of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium encouraged to advance TW technologies necessary more for future accelerator-scale one. Fermilab has proposed a preliminary RF design of a half-meter scale TW cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell. It consists of a 7-cell structure and a power feed-back waveguide (WG) loop with new TW excitation and control schemes such as, double directional coupler and two WG tuners. Mock-up waveguide loop development was launched under Fermilab LDRD program to demon-strate those new RF schemes at a room temperature. Fab-rication drawings of a mock-up loop were completed. Here details and plans of the development are reported.

Furuta, F. [Fermilab] (ORCID:0009000072218576)↗

Mock-Up Waveguide Loop Development toward a Half-Meter Scale Traveling-Wave SRF Cavity

Mock-up waveguide loop development toward a half-meter scale traveling-wave SRF cavity ABSTRACT = Traveling-Wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The success of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium encouraged to advance TW technologies necessary more for future accelerator-scale one. Fermilab has proposed a preliminary RF design of a half-meter scale TW cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new TW excitation and control schemes such as, double directional coupler and two WG tuners. Mock-up waveguide loop development was launched under Fermilab LDRD program to demonstrate those new RF schemes at a room temperature. Fabrication drawings of a mock-up loop were completed. More details and plans of the development will be presented.

Furuta, Fumio [Fermilab]↗

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)↗

Progress and Challenges in Traveling-Wave SRF cavity development at Fermilab

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

Furuta, F.↗

Progress and Challenges in Traveling-Wave SRF cavity development at Fermilab

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

Furuta, F.↗

Kinetic Inductance Traveling Wave Amplifier Designs for Practical Microwave Readout Applications

Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

Physics↗

Travelling wave‐based fault detection and location in a real low‐voltage DC microgrid

Abstract This paper discusses a device‐level implementation of a travelling wave (TW) protection device (PD) designed for a real low‐voltage DC microgrid. The TWPD fault detection and location algorithm is executed on a commercial digital signal processor (DSP) board, involving signal sampling at 1 MHz via the DSP board's analog‐to‐digital converter (ADC). The analogue input card measures positive pole, negative pole and pole‐to‐pole voltages at the TWPD location. Upon a successful fault detection using a second‐order high‐pass filter, the voltage data is normalised and multi‐resolution analysis (MRA) is performed on a 128‐sample buffer around the TW arrival time. MRA employs the discrete wavelet transform (DWT) to capture high‐frequency voltage patterns, and then the Parseval's energy theorem quantifies these TW characteristics by computing the energy of reconstructed wavelet coefficients. These energy values per decomposed frequency band are the basis for training a random forest classifier that predicts fault location and type. The TWPD is fully implemented and connected to a real DC microgrid in Albuquerque, NM, USA, for validation, and results are shown for field tests verifying the performance under faults.

Paruthiyil, Sajay Krishnan [Department of Electric↗

Development of Superconducting RF Cavity in Traveling-Wave Regime at Fermilab

Niobium Superconducting RF (SRF) cavities have a theoretical peak magnetic field which limits the accelerating field to 50-60 MV/m. Presently, all SRF cavities operate in a Standing Wave (SW) resonance field in which particles experience an accelerating force alternating from zero to peak. In contrast, a resonance field in Traveling Wave (TW) mode propagates along with a structure, so particles in such field can experience a constant acceleration force and could have higher energy gain than that of SW mode. This phenomenon is defined by the cavity’s transit time factor, T. A TW structure proposed in an early study achieves T ~0.9, suggesting an increase in acceleration per structure by more than 20% compared to a SW structure (T ~0.7). The early stages of developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. It demonstrated the TW resonance excitation at room temperature in the “as-fabricated” 3-cell structure. Here we report recent progresses and the first cryogenic testing of the 3-cell TW cavity in 2 K liquid helium at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Josephson Traveling Wave Parametric Amplifiers to Enable Future Neutrino Mass Measurements

Technologies for “quantum sensing" have the promise of dramatically improved sensitivity in some experiments that explore nuclear physics at the boundaries of our current knowledge. In particular, the Josephson Traveling Wave Parametric Amplifier (JTWPA) could enable future experiments such as Project 8 that use Cyclotron Radiation Emission Spectroscopy (CRES) to measure the absolute neutrino mass scale in tritium beta decays. CRES consists of detecting a signal of approximately one femtowatt of power radiated by electrons trapped in a 1-T magnetic field. The frequency of that radiation, around 27 GHz for a tritium endpoint electron, is inversely proportional to the electron energy. One of the significant challenges of a CRES experiment is the detection of minimal signal power levels. State-of-the-art transistor-based technologies will not likely achieve sufficient signal-to-noise ratio (SNR) in a competitive neutrino mass experiment. However, emerging quantum technologies have been demonstrated to operate at the fundamental lower limits of noise permitted by the laws of quantum mechanics. Of those technologies, JTWPAs appear to satisfy future performance needs with speed gain, bandwidth, and very low noise. We propose to bring together a group of neutrino physicists, experts in the needs of future neutrino mass measurements, with leaders in the field of quantum information science and JTWPA technology to develop JTWPAs appropriate for neutrino mass measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating Ion Accumulation and Storage in Traveling Wave Based Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) technology has demonstrated high resolving power ion mobility separation and flexibility to integrate complex ion manipulations into a single experimental platform. To enable IMS separations, trapping/accumulating ions inside SLIM (or in-SLIM) prior to injection of a packet for separations provides ease of operation and reduces the need for dedicated ion traps external to SLIM. To fully characterize the ion accumulation process, we have evaluated the effect of TW amplitudes, ion collection times, and storage times on the “in-SLIM” accumulation process. The study utilized a SLIM module comprising 5 distinct tracks, each with a specific ion accumulation configuration. The effect of the TW conditions on the accumulation process was investigated for a 3-peptide mixture: kemptide, angiotensin II, and neurotensin at a TW speed of 106 m/s. The effect of ion accumulation time/collection time and storage time was investigated, in addition to TW amplitude. Overall, the signal of the analyte ions increased when the ion collection time increased from 49 to 163 ms but decreased when the ion collection time increased further to 652 ms due to the space charge effects. Ion losses were observed at high TW amplitudes (e.g., 15 V p–p and 20 V p–p ). In addition, under space charge conditions (e.g., collection times of 163 and 652 ms), the signal of the analyte ions decreased with an increase in storage times for all TW amplitudes applied to the trapping region. For ion accumulation, the data indicate that gentler TW conditions must be utilized to minimize ion losses and fragments to benefit from the “in-SLIM” accumulation process. Finally, wider SLIM tracks provided better performance than those with narrower tracks.

59 BASIC BIOLOGICAL SCIENCES↗